Repair/Maintenance Of External Electrification , Transformer And Dg Set At Tech Area Hansa Under Ge ( I ) ( Cg ) Goa, HANSA SOUTH GOA-Goa

Military Engineer Services-MES has published Repair/Maintenance Of External Electrification , Transformer And Dg Set At Tech Area Hansa Under Ge ( I ) ( Cg ) Goa. Submission Date for this Tender is 31-05-2021. Coats and Jackets Tenders in HANSA SOUTH GOA Goa. Bidders can get complete Tender details and download the document.




Tender Notice

27742585
Corrigendum : Repair/Maintenance Of External Electrification , Transformer And Dg Set At Tech Area Hansa Under Ge ( I ) ( Cg ) Goa
Open Tender
Indian
Goa
HANSA SOUTH GOA
31-05-2021

Tender Details

Repair/Maintenance Of External Electrification , Transformer And Dg Set At Tech Area Hansa Under Ge ( I ) ( Cg ) Goa , Part I- ( Repair/Maintenance Of Ext Electrification , Transformer ) Servicing And Repairing/ Carrying Out Maintenance Of 11Kv/440V Transformer Including The Following Works For 100 Kva Capacity As Follows Complete All As Specified & Directed : - ( A ) Disconnecting The Transformer From Platform , Electrical Connection From Ht & Lt Side , Earthing Side , Lifting With The Help Of Crane Transporting To Trade Work Shop And Unloading All As Specified . ( B ) Dismantling The Transformer , Drain Out Trransformer Oil , Lift The Cover , Coil Assembly & Keep Up The Assembly In Open Upto The Preparation . Scratching The Body With Wire Brush For Any Carbon Deposite And Oily Substance From The Transformer . ( C ) Cleaning The Core Iron Sheet Laminations Assembly By Oil Complete , Removing Carbon Sediments , Dust In The Coil And Core Gently Without Making Any Damage To Coil And Core . ( D ) Re-Assembling All Dismantled Parts Including Provision Of New Gasket , Nut , Bolts , Refilling With Transformer Oil . ( E ) Lifting The Transformer From Trade Workshop , Transporting Back To Site . Unloading On The Platform Connecting The Transormer With Foundation , Electrical Connection To Ht , Lt And Earthing Side , Testing And Commissioning For Satisfactory Performance . Note: ( I ) Transformer Oil Filteration And Topup Of New Oil Will Be Measured Seperately . ( Ii ) All Petty Parts Including Nut , Bolts , Gasket And Minor Weldings /Patch Work Are Deemed To Be Included In The Rate Quoted . ( Iii ) The Rate For Lifting By Crane , Transporting , Unloading Are Deemed To Be Included In The Unit Rate Quoted . ( Iv ) All Major Parts E . G . Bushes , Silica Gel , Breather Unit , Lug If Any Replaced And Rewinding Of Ht & Lt Coil Are Not Included In The Unit Rate Mentioned . Same Will Be Priced And Measured Seperately Under Relevant Items Of Schedule Complete All As Specified & Directed . , Supply Only Ht Bushing Insulator , Brass Metal Studs Nut & Washers Suitable For Ht Bush Side Of Transformer Up To 100 Kva . Complete All As Specified & Directed . , All As Per Item No 2 Above But For 500 Kva Capacity Of Transformer Complete All As Specified & Directed , Supply Only Lt Bushing Insulator , Brass Metal Studs Nut & Washers Suitable For Lt 415 Volt Bush Side Of Transformer For 100 Kva Capacity Of Transformer Complete All As Specified & Directed . , All As Per Item No 4 Above But For 500 Kva Capacity Of Transformer Complete All As Specified & Directed . , Supply Only New Ehv Grade Insulating Transformer Oil Complete With Minimum Bdv 60 Kv Complete All As Specified And As Directed . , Filteration Of Existing Transformer Oil With High Pressure Vaccum Filteration Plant To Improve Dielectric Strength Of Insulating Oil Including Testing For Bdv Of The Filteration Oil Not To Be Less Than Bdv 60Kv All As Specified And Directed . Note :- ( A ) Rates Includes The Requirement Of Tools/Plants At Site Where Transformer Oil To Be Filtered . ( B ) Transformer Shall Be Kept In Off Position During Filteration . ( C ) Temperature Of Oil Should Be Kept Below 75 C During Filteration Complete All As Specified & Directed . , Supply Only In Existing Breather Silca Jel Of Superior Quality For Transformer Breather Complete All As Specified And Directed By Engr-In-Charge . , Supply Only In Breather Unit Of Transperant Pvc Material Including Its Replacement For Transformer Of Capacity Up To 500 Kva Complete All As Specified & Directed . , M & L Fixing Of Aluminium Lugs On Lt Cable To Connecting On Lt Side Bushing By Removing Old Lugs Fixed On Lt Bushing Complete For 16 To 35 Sqmm 4 Core Cable Complete All As Specified & Directed , M & L Fixing Of Aluminium Lugs On Lt Cable To Connecting On Lt Side Bushing By Removing Old Lugs Fixed On Lt Bushing Complete For 50 To 400 Sqmm 3 . 5 Core Cable Complete All As Specified & Directed . , M & L Fault Finding For Transformer 11Kv/440V And Capacity Upto 500Kva Incl Dismantling Lt And Ht Cable Connection , Checking The Transformer Winding For Open Circuit , Short Circuit Or Internal Short Circuit Lt/Ht Bushing Failure Etc All As Directed And Specified By Engr-In-Charge . Note:-I ) Inspection And Fault Location Shall Be Carried Through Authorised Agencies . Ii ) Equipment Required For Fault Finding Shall Be Provided By The Contractor Complete All As Specified & Directed . , M&L Disc Type Porcelain Vitreous , Brown Or White Insulator To Suit 11 Kv Ht Working Pressure Of Size 145 Mm Height , 255 Mm Dia , Including . One Galvanised Mild Steel Spindle , Two Galvanised Iron Washer And One Gi Nut Complete Including Dismantling Existing Old Insulator From Position Complete All As Specified & Directed . , M&L Pin Type Porcelain Vitreous , Brown Of White Insulator To Suit 11 Kv Ht Of Working Pressure Of Size 150Mm Height , 150Mm Dia , Including One Galvanised Mild Steel Spindle , Two Galvanished Iron Washer And One Gi Nut Complete Including Dismantling Existing Old Insulator From Position Complete All As Specified & Directed . , M&L Post Insulator Suitable For 11 Kv Ht Working Pressure Including All Connected Accessories Including Dismantling Existing Old Insulator From Position Complete All As Specified & Directed . , Taking Down 11 Kv Air Break Gang Operated Switches Vertical / Horizontal Mounted Including Insulators And Operating Mechanism For Insulators And Operating Mechanism For Repair/Replacement Of Broken/Worn Out Components And Insulators Etc . Complete All As Directed . , Material & Labour For Outdoor Type Gang Operated Air Break Switch Triple Pole , Mechanically Operated , Mounted On Insulator And Steel Frame , With Operting Mechanism Worked From Ground Level With Gi Pipe Medium Grade , For Current Rating Upto 200 Amps Suitable For Vertical Mounting Fixed Type Complte With 15 Nos Ht Insulators Suitable For Ht 11 Kv Complete All As Specified And Directed . , Servicing And Repair/Maintenance Of Apfc Panel Board Heavy Duty Various Capacity Auto / Manual Operation Of Various Location In Tech Area , Coast Guard Including Repairs/Replacement Of Fuses , Fuse Link , Control Fuses Auto Manual Selector Switch , Current Transformers , Mccb And Checking / Replacing Of Defective Control Wiring If Any Replacement Of Defective Cable Lugs , Patch Works , Welding , Replacement Of Defective Door Hinges And Testing And Commissioning Complete For Outdoor/Indoor Type Upto180 Kvar With Auto 1:2:4:5 Kvar With 5 Kvar Fixed Capacitor Complete All As Specified & Directed . , S & F In Replacement Of Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 50 To 95 Sqmm Complete All As Specified & Directed . , S & F In Replacement Ht 11 Kv End Termination Joint Kit Outdoor Heat Shrinkable Type For 50 To 95 Sqmm 3 Core Xlpe Cable 11000 Volts Complete All As Specified & Directed , S & F In Replacement Ht 11 Kv End Termination Joint Kit Outdoor Heat Shrinkable Type For 120 To 185 Sqmm 3 Core Xlpe Cable 11000 Volts Complete All As Specified & Directed , M &L Graded Coarse Aggregate ( Broken Stone Or Boulders ) Of Size 40 Mm In Substation Yard For Laying Complete All As Specified & Directed , M & L Preparation Of Old Painted External Surfaces Of Ht 2 Pole Structures Consisting Of Cross Arms , God Assy With Pipe , Do Fuse Assy , Clamps Etc . , Of Any Description And Applying One Coat Of Aluminium Paint By Mannualy Complete All As Specified & DirectedNote :- This Rate Inclusive Of Painting All Minor Items Such As Clamps , Brackets , Nuts , Bolts And Washers Which Is Not Particularly Mentioned In The Structures & Each Job Will Be Measured And Paid . , Dis

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-05-2021
2 15-May-2021 Corrigendum No 1 Date 22-05-2021
3 24-May-2021 Corrigendum No 2 Date 31-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 16700.0 /-
Tender Value
INR 8.33 Lakhs /-