Kerala Water Authority-KWA has published Rmc- Carwss To Polpully Panchayath -Repair Works Of Various Pipelines For The Year 2021-22. Submission Date for this Tender is 04-05-2021. Pipe Laying Tenders in Polpully Kerala. Bidders can get complete Tender details and download the document.
Work Name:AMC- CARWSS TO POLPULLY-REPAIR WORKS OF VARIOUS PIPE LINE FOR THE YEAR 2021-2022 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Leak rectification work in PVC (Class 2 to 6) pipe line including detecting and locating leak, earth work excavation in all kinds of soil for for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipe line with out causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe in to the trenches,placing in position aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or or any available joint and testing the pipe line by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards,lighting,watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers including the cost of pipe and PVC specials; PVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing. | BI01010001010000000000000515BI0100001112 | ||
2 | 2 | 32mm | BI01010001010000000000000515BI0100001113 | 1 | Leak |
3 | 3 | 40mm | BI01010001010000000000000515BI0100001114 | 1 | Leak |
4 | 4 | 50mm | BI01010001010000000000000515BI0100001115 | 3 | Leak |
5 | 5 | 63mm | BI01010001010000000000000515BI0100001116 | 14 | Leak |
6 | 6 | 75mm | BI01010001010000000000000515BI0100001117 | 8 | Leak |
7 | 7 | 90mm | BI01010001010000000000000515BI0100001118 | 10 | Leak |
8 | 8 | Leak rectification work in PVC (Class 2 to 6) pipe line including detecting and locating leak, earth work excavation in all kinds of soil for for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipe line with out causing any damages to the balance portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe, cutting and lowering new pipe in to the trenches,placing in position aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or repairable joint and testing the pipe line by operating the valves concerned, and rectifying the defects if noticed and refilling the trenches in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site without causing any damages to the existing utilities, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards,lighting, ribbon fencing, watching, traffic control etc.complete as per the direction of Departmental officers, including the cost of pipe & specials but excluding the cost of CIR Joints; PVC Pipes and specials shall be of good quality and conforming to relevant standards: Socket & CIR Jointing. | BI01010001010000000000000515BI0100001119 | ||
9 | 9 | 90mm | BI01010001010000000000000515BI0100001120 | 2 | Leak |
10 | 10 | 110mm | BI01010001010000000000000515BI0100001121 | 2 | Leak |
11 | 11 | 140mm | BI01010001010000000000000515BI0100001122 | 2 | Leak |
12 | 12 | 160mm | BI01010001010000000000000515BI0100001123 | 2 | Leak |
13 | 13 | 200mm | BI01010001010000000000000515BI0100001124 | 2 | Leak |
14 | 14 | 250mm | BI01010001010000000000000515BI0100001125 | 2 | Leak |
15 | 15 | Leak rectification work in PVC (Class 2 to 6) pipe line including detecting and locating leak, earth work excavation in all kinds of soil for for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipe line with out causing any damages to the balance portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe, cutting and lowering new pipe in to the trenches,placing in position aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or repairable joint and testing the pipe line by operating the valves concerned, and rectifying the defects if noticed and refilling the trenches in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site without causing any damage to the existing utilities, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, ribbon fencing, lighting,watching, traffic control etc.complete as per the direction of Departmental officers, including the cost of pipe & specials but excluding the cost of CIR Joints; PVC Pipes and specials shall be of good quality and conforming to relevant standards: CIR Jointing. | BI01010001010000000000000515BI0100001126 | ||
16 | 16 | 110mm | BI01010001010000000000000515BI0100001127 | 2 | Leak |
17 | 17 | 140mm | BI01010001010000000000000515BI0100001128 | 2 | Leak |
18 | 18 | 160mm | BI01010001010000000000000515BI0100001129 | 2 | Leak |
19 | 19 | 200mm | BI01010001010000000000000515BI0100001130 | 2 | Leak |
20 | 20 | 250mm | BI01010001010000000000000515BI0100001131 | 2 | Leak |
21 | 21 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: | BI01010001010000000000000515BI0100001132 | 5 | sqm |
22 | 22 | Rectification of leakages of GI Pipes by replacing lengths up to 1.0m including earth work excavation in all kindss of soil for exposing leak portion of the pipe including tar / concrete cutting, by cutting, removing and stacking the damaged portion from the existing line without causing any damages to the remaining portion and specials and conveying and replacing with GI Pipes of suitable size and jointing by thraded coupler and union of suitable size including threading, alignment, laying and jointing to make a water tight joint, testing the line to the required pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges hire and conveyance of tools, plant and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, including the cost of specials but excluding cost of pipe and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001133 | ||
23 | 23 | 32mm,40,50mm | BI01010001010000000000000515BI0100001134 | 12 | Leak |
24 | 24 | 65mm | BI01010001010000000000000515BI0100001135 | 6 | Leak |
25 | 25 | 80mm | BI01010001010000000000000515BI0100001136 | 2 | Leak |
26 | 26 | 100mm | BI01010001010000000000000515BI0100001137 | 2 | Leak |
27 | 27 | 125mm | BI01010001010000000000000515BI0100001138 | 1 | Leak |
28 | 28 | 150mm | BI01010001010000000000000515BI0100001139 | 3 | Leak |
29 | 29 | Rectification of leakages of GI Pipes in exposed portions by replacing lengths up to 1.0m by cutting, removing and stacking the damaged portion from the existing line without causing any damages to the remaining portion and specials and conveying and replacing with GI Pipes of suitable size and jointing by thraded coupler and union of suitable size including threading, alignement, laying and jointing to make a water tight joint, testing the line to the required pressure, rectifying any defects noticed, without causing any damages to any other utilities, including the charges hire and conveyance of tools, plant and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, necessary scaffolding including the cost of specials but excluding cost of pipe and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001140 | ||
30 | 30 | 50mm | BI01010001010000000000000515BI0100001141 | 2 | Leak |
31 | 31 | 65mm | BI01010001010000000000000515BI0100001142 | 2 | Leak |
32 | 32 | 80mm | BI01010001010000000000000515BI0100001143 | 2 | Leak |
33 | 33 | 100mm | BI01010001010000000000000515BI0100001144 | 1 | Leak |
34 | 34 | 125mm | BI01010001010000000000000515BI0100001145 | 1 | Leak |
35 | 35 | 150mm | BI01010001010000000000000515BI0100001146 | 1 | Leak |
36 | 36 | Rectification of leakages of GI Pipes in exposed portions by replacing lengths up to 1.0m by cutting, removing and stacking the damaged portion from the existing line without causing any damages to the remaining portion and specials and conveying and replacing with GI Pipes of suitable size and jointing by three run welding to make a water tight joint, painting the welded portion, testing the line to the required pressure, rectifying any defects noticed, without causing any damages to any other utilities, including the charges hire and conveyance of tools, plant and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, necessary scaffolding including the cost of specials but excluding cost of pipe and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001147 | ||
37 | 37 | 50mm | BI01010001010000000000000515BI0100001148 | 1 | Leak |
38 | 38 | 65mm | BI01010001010000000000000515BI0100001149 | 2 | Leak |
39 | 39 | 80mm | BI01010001010000000000000515BI0100001150 | 2 | Leak |
40 | 40 | 100mm | BI01010001010000000000000515BI0100001151 | 2 | Leak |
41 | 41 | 125mm | BI01010001010000000000000515BI0100001152 | 1 | Leak |
42 | 42 | 150mm | BI01010001010000000000000515BI0100001153 | 2 | Leak |
43 | 43 | Repairing leakage/breakage of AC pipe line by cutting and dismantling the damaged pipe portion (up to 1.5 m) including charges for earth work excavation in all kinds of soil including tar / concrete cutting for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new AC pipe to the required length, rejointing the pipeline using CID Joints , testing the pipe line by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers excluding the cost of pipe and CID Joints. | BI01010001010000000000000515BI0100001154 | ||
44 | 44 | 80mm | BI01010001010000000000000515BI0100001155 | 30 | Leak |
45 | 45 | 100mm | BI01010001010000000000000515BI0100001156 | 20 | Leak |
46 | 46 | 125mm | BI01010001010000000000000515BI0100001157 | 10 | Leak |
47 | 47 | 150mm | BI01010001010000000000000515BI0100001158 | 10 | Leak |
48 | 48 | 200mm | BI01010001010000000000000515BI0100001159 | 2 | Leak |
49 | 49 | 225mm | BI01010001010000000000000515BI0100001160 | 1 | Leak |
50 | 50 | 250mm | BI01010001010000000000000515BI0100001161 | 1 | Leak |
51 | 51 | 300mm | BI01010001010000000000000515BI0100001162 | 1 | Leak |
52 | 52 | Rectification of leakages in CI Pipe of all kinds by replacing a length up to 1.5m including earth work excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting and removing and stacking the damaged portion from the existing line without causing any damages to the line and specials and conveying and replacing with the CI pipe and conveying and jointing with CID joint / suitable mechanical joint of suitable size or any other available size suitable joints after cleaning the ends, grinding if necessary, centering the pipe inserting the joints tightening to make a water tight joint charging and testing to the required pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges of conveyance and hire for tools and plant, bailing out water, lighting, watching, ribbon fencing,providing caution boards, traffic diversion but excluding cost of materials and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001163 | ||
53 | 53 | 80mm | BI01010001010000000000000515BI0100001164 | 1 | Leak |
54 | 54 | 200mm | BI01010001010000000000000515BI0100001165 | 1 | Leak |
55 | 55 | Rectification of minor joint leakages in CI Pipe including earth work excavation in all kinds of soil for exposing leaking joint including tar cutting / concrete cutting, without causing any damages to the line and specials, cleaning the joints including raking out the damaged lead wool, conveying and inserting hemp and lead wool and caulking after cleaning the ends, charging and testing to the required pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges of conveyance and hire for tools and plant, bailing out water, lighting, watching, ribbon fencing, providing caution boards, traffic diversion, including cost of materials and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001166 | ||
56 | 56 | 80mm | BI01010001010000000000000515BI0100001167 | 1 | Leak |
57 | 57 | 200mm | BI01010001010000000000000515BI0100001168 | 1 | Leak |
58 | 58 | 250mm | BI01010001010000000000000515BI0100001169 | 1 | Leak |
59 | 59 | 300mm | BI01010001010000000000000515BI0100001170 | 1 | Leak |
60 | 60 | Rectification of joint leakages in DI Pipe (cutting, removing and laying back a length of 1.0m from one side of the joint) including earth work excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, by cutting and removing a portion of pipe from the damaged joint without causing any damages to the remaining portion of the line and specials and replacing the pipe with mechanical and tyton joint after cleaning the ends, centering the pipe, providing the joints, testing the line to the required test pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges of hire and conveyance of tools, plants and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion but excluding cost of mechanical joint and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001171 | ||
61 | 61 | 150mm | BI01010001010000000000000515BI0100001172 | 1 | Leak |
62 | 62 | 200mm | BI01010001010000000000000515BI0100001173 | 1 | Leak |
63 | 63 | 250mm | BI01010001010000000000000515BI0100001174 | 1 | Leak |
64 | 64 | 300mm | BI01010001010000000000000515BI0100001175 | 1 | Leak |
65 | 65 | Repairing the leak of valve by removing the damaged gland packing, providing new gland packing, bailig out water, operating the valve et complete. -Repairing leak 80/100mm sluice valve/GM valve | BI01010001010000000000000515BI0100001176 | 2 | No |
66 | 66 | Repairing the leak of valve by removing the damaged gland packing, providing new gland packing, bailig out water, operating the valve et complete. 125/150mm GM Valve/Sluice valve | BI01010001010000000000000515BI0100001177 | 2 | No |
67 | 67 | Repairing the leak of valve by removing the damaged gland packing, providing new gland packing, bailig out water, operating the valve et complete. 200/225mm GM Valve/Sluice valve | BI01010001010000000000000515BI0100001178 | 2 | No |
68 | 68 | Repairing the leak of valve by removing the damaged gland packing, providing new gland packing, bailig out water, operating the valve et complete. 250/300mm GM Valve/Sluice valve | BI01010001010000000000000515BI0100001179 | 2 | No |
69 | 69 | REPAIRING AIR VALVES-REPLACING BALL Repairing the leak of Air valve by removing the damaged ball , providing new ball, bailig out water, operating the valve et complete. | BI01010001010000000000000515BI0100001180 | 12 | No |
70 | 70 | Plugging 15/20mm G I pipe after desmantling using G I plug including cost of plug etc complete | BI01010001010000000000000515BI0100001181 | 2 | No |
71 | 71 | Disconnecting water connection from service mains along earthern road without causing any damage to the existing line including charges of earth work excavation in all kinds of soil for exposing connection point including tar cutting / conrete cutting if any, making the disconnection point water tight charging and testing to the required pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other existing utilities, including the charges of hire for tools and plant, conveyance of tools and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion but excluding cost of materials and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001182 | 23 | Disconnection |
72 | 72 | Supplying and fixing 15 / 20 mm PVC public tap after dismantling the damaged tap including all cost of materials, labour charges, hire for tools and as per the direction of the department officers etc complete. | BI01010001010000000000000515BI0100001183 | 20 | Nos |
73 | 73 | Rectifying the leakages in boring point of public tap connection including earth work excavation in all kinds of soil for exposing the boring point including concrete / tar cutting, dismantling the damaged saddle piece,cutting and removing damaged portion of pipe line,fixing new saddle piece,laying 20/25 mm PVC 10Kg/cm2 pipe in place of damaged portion of pipe and connecting with existing pipe line,testing the line to the required test pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges of hire and conveyance of tools, plants and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, including cost of pipe and saddle piece and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001184 | 9 | Leak |
74 | 74 | Rectifying the leakages in vertical pipe of public tap connection including earth work excavation in all kinds of soil for exposing the pipeline including concrete / tar cutting,cutting and removing damaged portion of pipe, fixing new 20/25 mm GI pipe and specials in place of damaged portion of pipe and connecting with existing pipe line,testing the line to the required pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges of hire and conveyance of tools, plants and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, including cost of pipe and specials and as per the direction of departmental officers etc. complete. | BI01010001010000000000000515BI0100001185 | 10 | Leak |
75 | 75 | Washing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns, disposing the the slurry / waste materilas away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the exististing strucutre and installations, charges including the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete. | BI01010001010000000000000515BI0100001186 | 5000 | sqm |
76 | 76 | Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road | BI01010001010000000000000515BI0100001187 | 10 | sqm |
77 | 77 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | BI01010001010000000000000515BI0100001188 | 1.5 | cum |
78 | 78 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) | BI01010001010000000000000515BI0100001189 | 1 | cum |
79 | 79 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil | BI01010001010000000000000515BI0100001190 | 5 | cum |
80 | 80 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001191 | 1000 | sqm |
81 | 81 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | BI01010001010000000000000515BI0100001192 | 100 | sqm |
82 | 82 | Providing protection tubes for valves witrh DI/AC/PVC pipe bit excluding cost of pipe but including conveyance of pipes,earthwork excavation and refilling etc.complete | BI01010001010000000000000515BI0100001193 | 1 | No |
83 | 83 | Supply of Fitter for various works | BI01010001010000000000000515BI0100001194 | 12 | No |
84 | 84 | Supply of Man mazdoor for various works | BI01010001010000000000000515BI0100001195 | 10 | No |
85 | 85 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore | BI01010001010000000000000515BI0100001196 | 3 | No |
86 | 86 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore | BI01010001010000000000000515BI0100001197 | 3 | No |
87 | 87 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) | BI01010001010000000000000515BI0100001198 | ||
88 | 88 | 25mm | BI01010001010000000000000515BI0100001199 | 1 | No |
89 | 89 | 32mm | BI01010001010000000000000515BI0100001200 | 1 | No |
90 | 90 | 40mm | BI01010001010000000000000515BI0100001201 | 1 | No |
91 | 91 | 50mm | BI01010001010000000000000515BI0100001202 | 4 | No |
92 | 92 | 80mm | BI01010001010000000000000515BI0100001203 | 1 | No |
93 | 93 | 20mm | BI01010001010000000000000515BI0100001204 | 1 | Nos |
94 | 94 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore | BI01010001010000000000000515BI0100001205 | 1 | No |
95 | 95 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore | BI01010001010000000000000515BI0100001206 | 1 | No |
96 | 96 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameter | BI01010001010000000000000515BI0100001207 | 1 | Nos |
97 | 97 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):125 mm diameter | BI01010001010000000000000515BI0100001208 | 1 | Nos |
98 | 98 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):150 mm diameter | BI01010001010000000000000515BI0100001209 | 1 | Nos |
99 | 99 | Supply of Lead Wool | BI01010001010000000000000515BI0100001210 | 2 | kg |
100 | 100 | Providing and fixing G.I. Union in G.I pipe including cutting and threading the pipe and making long screws etc. complete ( New work) | BI01010001010000000000000515BI0100001211 | ||
101 | 101 | 15mm | BI01010001010000000000000515BI0100001212 | 2 | No |
102 | 102 | 20mm | BI01010001010000000000000515BI0100001213 | 2 | No |
103 | 103 | 25mm | BI01010001010000000000000515BI0100001214 | 1 | No |
104 | 104 | 32mm | BI01010001010000000000000515BI0100001215 | 1 | No |
105 | 105 | 40mm | BI01010001010000000000000515BI0100001216 | 1 | No |
106 | 106 | 50mm | BI01010001010000000000000515BI0100001217 | 2 | No |
107 | 107 | 65mm | BI01010001010000000000000515BI0100001218 | 1 | No |
108 | 108 | 80mm | BI01010001010000000000000515BI0100001219 | 1 | No |
109 | 109 | Providing and fixing G.I Union in existing G.I pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required | BI01010001010000000000000515BI0100001220 | ||
110 | 110 | 15mm | BI01010001010000000000000515BI0100001221 | 1 | No |
111 | 111 | 20mm | BI01010001010000000000000515BI0100001222 | 1 | No |
112 | 112 | 25mm | BI01010001010000000000000515BI0100001223 | 1 | No |
113 | 113 | 32mm | BI01010001010000000000000515BI0100001224 | 1 | No |
114 | 114 | 40mm | BI01010001010000000000000515BI0100001225 | 1 | No |
115 | 115 | 50mm | BI01010001010000000000000515BI0100001226 | 1 | No |
116 | 116 | 65mm | BI01010001010000000000000515BI0100001227 | 1 | No |
117 | 117 | 80mm | BI01010001010000000000000515BI0100001228 | 1 | No |
118 | 118 | Supply of GI Threaded Coupling, 100mm. | BI01010001010000000000000515BI0100001229 | 2 | No |
119 | 119 | Supply of GI Threaded Coupling, 80mm. | BI01010001010000000000000515BI0100001230 | 2 | No |
120 | 120 | Supply of GI Threaded Coupling, 65mm. | BI01010001010000000000000515BI0100001231 | 2 | No |
121 | 121 | Supply of GI Threaded Coupling, 50mm. | BI01010001010000000000000515BI0100001232 | 2 | No |
122 | 122 | Supply of GI Threaded Coupling, 40mm. | BI01010001010000000000000515BI0100001233 | 2 | No |
123 | 123 | supplying and fixing 15mm GI coupling | BI01010001010000000000000515BI0100001234 | 2 | No |
124 | 124 | Supply of GI Socket, 20mm. | BI01010001010000000000000515BI0100001235 | 1 | No |
125 | 125 | supplying and fixing 32mm Gi coupling | BI01010001010000000000000515BI0100001236 | 1 | No |
126 | 126 | Supplying and fixing 15mm GI elbow | BI01010001010000000000000515BI0100001237 | 5 | No |
127 | 127 | supplying and fixing 20mm GI elbow | BI01010001010000000000000515BI0100001238 | 3 | No |
128 | 128 | Supplying and fixing 40mm GI Elbow | BI01010001010000000000000515BI0100001239 | 2 | No |
129 | 129 | Supplying and fixing 50mm GI Elbow | BI01010001010000000000000515BI0100001240 | 2 | No |
130 | 130 | Supplying and fixing 15mm GI Bend | BI01010001010000000000000515BI0100001241 | 2 | No |
131 | 131 | Supplying and fixing 20mm GI Bend | BI01010001010000000000000515BI0100001242 | 2 | No |
132 | 132 | Supplying and fixing 40mm GI bend | BI01010001010000000000000515BI0100001243 | 2 | No |
133 | 133 | supplying and fixing 50mm GI bend | BI01010001010000000000000515BI0100001244 | 2 | No |
134 | 134 | Supplying and fixing 65mm GI Bend | BI01010001010000000000000515BI0100001245 | 2 | No |
135 | 135 | Supplying and fixing 80mm GI bend | BI01010001010000000000000515BI0100001246 | 2 | No |
136 | 136 | Supplying and fixing 20/15mm GI Reducer | BI01010001010000000000000515BI0100001247 | 5 | No |
137 | 137 | Supplying and fixing 32*20/15 mm diaGI reducer | BI01010001010000000000000515BI0100001248 | 1 | No |
138 | 138 | Supplying and fixing 40/32mm GI Reducer | BI01010001010000000000000515BI0100001249 | 2 | No |
139 | 139 | Supplying and fixing 50*40/32/25/20 mm dia GI Reducer | BI01010001010000000000000515BI0100001250 | 2 | No |
140 | 140 | Supplying and fixing 65*50/40/32/25/20 mm dia GI reducer | BI01010001010000000000000515BI0100001251 | 2 | No |
141 | 141 | Supplying and fixing 80*65/50 mm dia GI Reducer | BI01010001010000000000000515BI0100001252 | 2 | No |
142 | 142 | Supplying and fixing 65X50mm GI Bush | BI01010001010000000000000515BI0100001253 | 2 | No |
143 | 143 | Supplying and fixing 15*15*15mm GI Tee | BI01010001010000000000000515BI0100001254 | 3 | No |
144 | 144 | Supplying and fixing 20*20*20 mmTEE | BI01010001010000000000000515BI0100001255 | 3 | No |
145 | 145 | Supplying and fixing 40*40*40mmTEE | BI01010001010000000000000515BI0100001256 | 2 | No |
146 | 146 | Supplying and fixing 50*50*50mmTEE | BI01010001010000000000000515BI0100001257 | 2 | No |
147 | 147 | Supplying and fixing 65*65*65mm GI Tee | BI01010001010000000000000515BI0100001258 | 2 | No |
148 | 148 | Supplying and fixing 15mm GI Plug | BI01010001010000000000000515BI0100001259 | 15 | No |
149 | 149 | Supplying and fixing 20mm GI Plug | BI01010001010000000000000515BI0100001260 | 3 | No |
150 | 150 | Supplying and fixing 32mm GI Plug | BI01010001010000000000000515BI0100001261 | 2 | No |
151 | 151 | Supplying and fixing 40mm GI Plug | BI01010001010000000000000515BI0100001262 | 2 | No |
152 | 152 | Supplying and fixing 50mm GI plug | BI01010001010000000000000515BI0100001263 | 1 | No |
153 | 153 | Supply of PVC Tap | BI01010001010000000000000515BI0100001264 | 5 | No |
154 | 154 | Supplying and fixing 15/20mm Brass Tap | BI01010001010000000000000515BI0100001265 | 3 | No |
155 | 155 | SUPPLYING AND FIXING 32mm MS SADDLES/CLAMPS INCLUDING WASHER,NUT BOLT ETC | BI01010001010000000000000515BI0100001266 | 1 | No |
156 | 156 | SUPPLYING AND FIXING 40mm MS SADDLES/CLAMPS INCLUDING WASHER,NUT BOLT ETC | BI01010001010000000000000515BI0100001267 | 3 | No |
157 | 157 | Supplying 50mm MS Saddle | BI01010001010000000000000515BI0100001268 | 2 | No |
158 | 158 | Supplying 65mm MS Saddle | BI01010001010000000000000515BI0100001269 | 2 | No |
159 | 159 | Supplying 80mm MS Saddle | BI01010001010000000000000515BI0100001270 | 2 | No |
160 | 160 | Supplying and fixing 100mm MS Saddle/Clamp including washer nut bolt etc complete | BI01010001010000000000000515BI0100001271 | 2 | No |
161 | 161 | Supplying and fixing 125mm MS Saddle/Clamp including washer nut bolt etc complete | BI01010001010000000000000515BI0100001272 | 3 | No |
162 | 162 | Supplying and fixing 150mm MS Saddle/Clamp including washer nut bolt etc complete | BI01010001010000000000000515BI0100001273 | 2 | No |
163 | 163 | Supplying 200mm MS Saddle | BI01010001010000000000000515BI0100001274 | 1 | No |
164 | 164 | Supplying 225mm MS Saddle | BI01010001010000000000000515BI0100001275 | 2 | No |
165 | 165 | Supplying and fixing 250mm MS Saddle/Clamp including washer nut bolt etc complete | BI01010001010000000000000515BI0100001276 | 1 | No |
166 | 166 | Supplying 300mm MS Saddle | BI01010001010000000000000515BI0100001277 | 1 | No |
167 | 167 | Supplying and fixing 50mm MS Flanges including nut, bolt, washer | BI01010001010000000000000515BI0100001278 | 2 | No |
168 | 168 | Supplying and fixing 65mm dia MS Flange | BI01010001010000000000000515BI0100001279 | 2 | No |
169 | 169 | Supply and fixing 80 mm MS flange | BI01010001010000000000000515BI0100001280 | 2 | No |
170 | 170 | Supplying and fixing 100mm dia MS Flange | BI01010001010000000000000515BI0100001281 | 2 | No |
171 | 171 | Supplying and fixing 125mm dia MS Flange | BI01010001010000000000000515BI0100001282 | 2 | No |
172 | 172 | Supplying and fixing 150mm dia MS Flange | BI01010001010000000000000515BI0100001283 | 2 | No |
173 | 173 | Supplying and fixing 80mm CID Joint including all accessories | BI01010001010000000000000515BI0100001284 | 5 | No |
174 | 174 | Supplying and fixing 100mm CID joint with all accessories | BI01010001010000000000000515BI0100001285 | 4 | No |
175 | 175 | Supplying and fixing 125mm CID Joint including all accessories | BI01010001010000000000000515BI0100001286 | 3 | No |
176 | 176 | Supplying and fixing 150mm CID Joint including all accessories | BI01010001010000000000000515BI0100001287 | 2 | No |
177 | 177 | Supplying and fixing 200mm CID joint with all accessories | BI01010001010000000000000515BI0100001288 | 2 | No |
178 | 178 | Supplying and fixing 225mm CID Joint including all accessories | BI01010001010000000000000515BI0100001289 | 1 | No |
179 | 179 | Supplying and fixing 250mm CID joint with all accessories | BI01010001010000000000000515BI0100001290 | 1 | No |
180 | 180 | Supplying and fixing 300mm CID joint with all accessories | BI01010001010000000000000515BI0100001291 | 6 | No |
181 | 181 | Supply of Rubber Gasket 80 mm dia | BI01010001010000000000000515BI0100001292 | 2 | No |
182 | 182 | Supply of Rubber Gasket 100 mm dia | BI01010001010000000000000515BI0100001293 | 2 | No |
183 | 183 | Supply of Rubber Gasket 125 mm dia | BI01010001010000000000000515BI0100001294 | 2 | No |
184 | 184 | Supply of Rubber Gasket 150 mm dia | BI01010001010000000000000515BI0100001295 | 2 | No |
185 | 185 | Supply of Rubber Gasket 200 mm dia | BI01010001010000000000000515BI0100001296 | 2 | No |
186 | 186 | Supply of Rubber Gasket 250 mm dia | BI01010001010000000000000515BI0100001297 | 2 | No |
187 | 187 | Supply of Rubber Gasket 300 mm dia | BI01010001010000000000000515BI0100001298 | 2 | No |
188 | 188 | Bolt and Nuts of all type of joints | BI01010001010000000000000515BI0100001299 | 1 | kg |
189 | 189 | Supplying and fixing 20mm air valve | BI01010001010000000000000515BI0100001300 | 1 | No |
190 | 190 | Supply of Cost of PVC Saddle piece( Average rate of 200/160/140/110/90/75/63/50mm) | BI01010001010000000000000515BI0100001301 | 1 | No |
191 | 191 | Supplying 20mm GI pipe medium | BI01010001010000000000000515BI0100001302 | 6 | metre |
192 | 192 | Supplying 25mm GI pipe medium | BI01010001010000000000000515BI0100001303 | 6 | metre |
193 | 193 | Supplying 32mm GI pipe medium | BI01010001010000000000000515BI0100001304 | 6 | metre |
194 | 194 | Supplying 40mm GI pipe medium | BI01010001010000000000000515BI0100001305 | 6 | metre |
195 | 195 | Supply of 50mm GI pipe (medium) | BI01010001010000000000000515BI0100001306 | 6 | metre |
196 | 196 | Supplying of 15 mm GI pipe(medium class) | BI01010001010000000000000515BI0100001307 | 6 | metre |