Electrification Work On Shekho Ki Dhani Hanumanji Temple To Mandiya By Pass Main Road Of Mcp Pali . , municipal council pali-Rajasthan

Department Of Local Bodies has published Electrification Work On Shekho Ki Dhani Hanumanji Temple To Mandiya By Pass Main Road Of Mcp Pali . . Submission Date for this Tender is 27-04-2021. Electrification Work Tenders in municipal council pali Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

27717069
Electrification Work On Shekho Ki Dhani Hanumanji Temple To Mandiya By Pass Main Road Of Mcp Pali .
Open Tender
Indian
Rajasthan
municipal council pali
27-04-2021

Tender Details

Electrification Work On Shekho Ki Dhani Hanumanji Temple To Mandiya By Pass Main Road Of Mcp Pali .

Key Value

Document Fees
INR 500 /-
EMD
INR 29660.0 /-
Tender Value
INR 14.83 Lakhs /-

BOQ Items

Name of Work: Electrification work on shekho ki dhani hanumanji temple to mandiya by pass main road of mcp pali.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Unarmoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. BI01010001010000000000000515BI0100001113
2 1.1 4x10.0 Sq.mm BI01010001010000000000000515BI0100001114 2000 Mtr
3 2 Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. BI01010001010000000000000515BI0100001115
4 2.1 8 mtr BI01010001010000000000000515BI0100001116 55 Nos.
5 3 P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. BI01010001010000000000000515BI0100001117
6 3.1 Single pole MCB (6 A to 32 A rating) BI01010001010000000000000515BI0100001118 110 Nos.
7 4 Supply, Erection and Fixing of hot dipped galvanised Overhang (60 X 3.25 mm) with cap (250 x 137.9 x 4.05 mm) over the existing poles BI01010001010000000000000515BI0100001119
8 4.1 Single arm overhang BI01010001010000000000000515BI0100001120 50 Nos.
9 4.2 Double arm overhang BI01010001010000000000000515BI0100001121 5 Nos.
10 5 Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. BI01010001010000000000000515BI0100001122 5 Nos.
11 6 Supplying and drawing of 2 x 2.5 sq.mm FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. BI01010001010000000000000515BI0100001123 600 Mtr
12 7 S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 8 SWG G.I. Wire BI01010001010000000000000515BI0100001124 2000 Mtr
13 8 MAIN CUBICAL PANEL / STREET LIGHT CONTROL PANEL\nP/F testing & commissioning of kiosk type weather proof out door main cubical panel size 750 mm X 1250 mm X 500 mm (app.) made out of 14 gauge MS sheet front and back both side openable duly hinged door with locking arrangement by providing both side held draft and all required hard wares. The cubical should be dust and vermin proof followed by coat of zimpholite primer and finally two coats of enamal gray paint. The cubical should be mounted with hard ware on angle iron frame size 50 X 50 X 6 mm and 1500 legs duly painted framed be grouted 750 mm below ground level with cement concrete 1:3:6 in 1000 X 500 X 600 mm and providing brick masonary along angle iron frame above G.L. They shall be in two section comprising as follows: \n (i) Providing & Fixing 415 V ,TP combination double break HRC switch fuse unit .100 Amp. rating for incoming supply with HRC fuse 100 Amp rating and of BCH/L&T/EE/ Siemens/ ABB make. \n (ii) Providing fixing timer switch TSQ 100 series 240 Volts, and full running service standred mounting with base of L & T or equivalent make including the cost of contactor 63 amp. 50 Hz. 440/400 volt. \n (iii) P/F open busbars 25mmX3mm of required length duly covered by heat shrinkable sleeves with busbar supporters \n (iv) Provision for residual current operated 63 Amp. 1 Pole ELCB of 30MA to 300 MA sensitively as required including making connections etc.(EE/Load stop make) \n (v) P/F 2 Nos. 415 Volts TPN combination double break switch fuse unit,63 Amp. Rating with HRC fuses (EE/mds/ SCHNEIDER bch/Siemens )for outgoing cable and making connection etc. also to have a provision for two nos. above switchs. \n (vi) P/F of 3 nos. RYB phase indicator resitance type complete with lamp \n P/F of HT danger plate of size 200 X 150 mm made of aluminium sheet 20 gauge. \n (vii) P/F cable glands double compression type and Al. lugs duly crimped for incoming cable and out going Cables. \n (viii) Providing 2 Nos. earth terminals including lugs and H/W duly inter connected with 8 SWG copper wire . \n (ix)Inter connection of main busbar to each out going switch and cable terminal shall be with 4 sqmm PVC copper conductor duly crimped with AL lugs. \n (x) Cable termination shall be fixed at backside of the panel with H/W and spring washers \n (xi) Light control switch with photo senser complete unit as required BI01010001010000000000000515BI0100001125 1 Nos.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail