Military Engineer Services-MES has published Repair Maint Of Cooling Applicance Like Water Coolers Deep Freezer Refrigerators Air Conditioners Etc And Other Allied Works In 4033 Fd Hosp 108 Er 33 Cesr 7033 Eme Bn 12 Para 5033 Asc 136 We And 620 Jadc Etc Under Age Em Of Ge Sukna. Submission Date for this Tender is 13-05-2021. Air Conditioner Tenders in Sukna West Bengal. Bidders can get complete Tender details and download the document.
Name of Work : REPAIR / MAINT OF COOLING APPLICANCE LIKE WATER COOLERS, DEEP FREEZER, REFRIGERATORS, AIR CONDITIONERS, ETC AND OTHER ALLIED WORKS IN 4033 FD HOSP, 108 ER, 33 CESR, 7033 EME BN, 12 PARA, 5033 ASC, 136 WE AND 620 JADC ETC UNDER AGE E/M OF GE SUKNA | |||||
---|---|---|---|---|---|
Sl. No. | TEXT # | Item Code / Make | Quantity | Units | |
1 | 1 | Transportation of unserviceable appliances of following type from MES store to outside workshop for carrying out the following phase of work :-\n(i) Dismantling of cooling appliances, opening up complete unit for strip inspection, segregation of serviceable and unserviceable spares and components like compressor, blower motor, evaporator, condensing coil etc. and other spare parts all as directed including carrying out servicing in case of serviceable components.\n(ii) Replacement of unserviceable components like compressor, blower motor, condensing coil etc. by repaired / new / reconditioned components as per existing to ensure smooth and efficient functioning of cooling appliance complete all as specified and as directed.\nNote:- (a) Repair to components, new component or reconditioned components shall be measured and paid separately under respective item.\n(b) Replacement of all unserviceable spare parts like, relays, capacitors, bushes, clamps etc. shall be measured and paid separately under respective item as supply only.\n(c) Carrying out fresh lubrication using grease / oil after cleaning and washing of old lubricating substance is deemed to be included in the item.\n(d) Carrying out one coat of spray painting to cooling appliances by 1st quality synthetic enamel paint as per existing colour code over existing painted surface including touching up of red oxide primer on the rusted surface after necessary preparation shall be measured and paid separately under respective item.\n(e) Assembling the complete unit by repaire / new components / spare and existing serviceable components including transportation to MES store and testing to ensure smooth and efficient functioning of appliances to the entire satisfaction of Engr-in-Charge is included in the item.\n(f) Charging of refrigerants to compressor of cooling appliance shall be measured and paid separately under respective item.\n | |||
2 | 1.1 | Window type Air conditioner of any capacity and make complete all as specified and directed.\n\n | 20 | Each Job | |
3 | 1.2 | Split type Air Conditioner of any capacity and make complete all as specified and directed.\n\n | 17 | Each Job | |
4 | 1.3 | Tower type Air Conditioner of any capacity and make complete all as specified and directed.\n\n | 6 | Each Job | |
5 | 1.4 | Water cooler of any capacity and make complete all as specified and directed.\n\n | 18 | Each Job | |
6 | 1.5 | Refrigerator of any capacity and make complete all as specified and directed.\n\n | 13 | Each Job | |
7 | 1.6 | Deep Freezer of any capacity and make complete all as specified and directed.\n\n | 7 | Each Job | |
8 | 2 | Carrying out repairs to blower motor of 1.5 / 2.0 TR Window Type Air Conditioner including rewinding with super enameled copper wire of appropriate gauge & replacement of bearing bushes, mounting bushes, heat varnishing and painting with one coat of synthetic enamel paint complete all as specified and directed.\nNote:- Repaired Blower motor shall be installed in against item No. 1.00 above\nMake of paint:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)\n | 15 | Each Job | |
9 | 3 | S&F blower motor as per existing, suitable for 1.5 / 2.0 TR Window type Air conditioner of any make including taking out old blower motor complete all as specified and directed.\n | 5 | Each | |
10 | 4 | S&F fan blade of blower motor as per existing, suitable for 1.5 / 2.0 TR Window type Air conditioner of any make including taking out old fan blade complete all as specified and directed.\n | 7 | Each | |
11 | 5 | S&F runner blade of blower motor as per existing, suitable for 1.5 / 2.0 TR Window type Air conditioner of any make including taking out runnder blade complete all as specified and directed.\n | 8 | Each | |
12 | 6 | S&F blower motor as per existing, suitable for outdoor unit of 1.5 / 2.0 TR Split type Air conditioner of any make including taking out old blower motor complete all as specified and directed.\n | 14 | Each | |
13 | 7 | S&F (AC/DC) blower motor as per existing, suitable for indoor unit of 1.5 / 2.0 TR Split type Air conditioner of any make including taking out old blower motor complete all as specified and directed.\n | 7 | Each | |
14 | 8 | S&F fan blade of blower motor as per existing, suitable for 1.5 / 2.0 TR Split type Air conditioner of any make including taking out old fan blade complete all as specified and directed.\n | 15 | Each | |
15 | 9 | S&F blower motor as per existing for outdoor unit of 3.5 / 4.0 TR Tower type Air conditioner of any make including taking out old blower motor complete all as specified and directed.\n | 4 | Each | |
16 | 10 | S&F (AC/DC) blower motor as per existing for indoor unit of 3.5 / 4.0 TR Tower type Air conditioner of any make including taking out old blower motor complete all as specified and directed.\n | 4 | Each | |
17 | 11 | S&F fan blade of blower motor as per existing, suitable for 3.5 / 4.0 TR Tower type Air conditioner of any make including taking out old fan blade complete all as specified and as directed.\n | 4 | Each | |
18 | 12 | S&F blower motor as per existing, suitable for 40 / 80 Litres capacity Water Cooler of any make including taking out old complete all as specified and directed.\n | 10 | Each | |
19 | 13 | S&F fan blade of blower motor as per existing suitable for 40 / 80 Litres capacity Water Cooler of any make including taking out old fan blade complete all as specified and directed.\n | 10 | Each | |
20 | 14 | S&F blower motor as per existing, suitable for 60 / 120 Litres capacity Water Cooler of any make including taking out complete all as specified and directed. \n | 8 | Each | |
21 | 15 | S&F fan blade of blower motor as per existing suitable for 120 / 120 Litres capacity Water Cooler of any make including taking out old fan blade complete all as specified and directed.\n | 10 | Each | |
22 | 16 | S&F blower motor as per existing, suitable for 150 / 150 Litres capacity Water Cooler of any make including taking out old blower motor complete all as specified and directed.\n | 10 | Each | |
23 | 17 | S&F fan blade of blower motor as per existing suitable for 150 / 150 Litres capacity Water Cooler of any make including taking out old fan blade from complete all as specified and directed.\n | 10 | Each | |
24 | 18 | S&F blower motor as per existing, suitable for 40 Litres capacity Water Cooler of any including taking out old blower motor complete all as specified and directed.\n | 4 | Each | |
25 | 19 | S&F fan blade of blower motor as per existing, suitable for 40 Litres capacity Water Cooler of any make including taking out old fan blade complete all as specified and directed.\n | 4 | Each | |
26 | 20 | S&F blower motor as per existing make, suitable for 300 / 500 Litres capacity Deep Freezer of any make including taking out old blower motor complete all as specified and directed.\n | 4 | Each | |
27 | 21 | S&F fan blade of blower motor as per existing, suitable for 300 / 500 Litres capacity deep freezer of any make including taking out old fan blade complete all as specified and directed.\n | 4 | Each | |
28 | 22 | S&F compressor as per existing, suitable for 00 TR capacity window type Air conditioner of any make including taking out old compressor complete all as specified and directed.\n | 4 | Each | |
29 | 23 | S&F rotary type compressor as per existing, suitable for 1.5 / 2 TR window type Air conditioner of any make including gas charge & taking out old compressor complete all as specified and directed. \nMake : As per existing make of AC available at site.\n | 4 | Each | |
30 | 24 | S&F reciprocating type compressor as per existing, suitable for 1.5 / 2 TR window type Air conditioner of any make including gas charge & taking out old compressor complete all as specified and directed. \nMake : As per existing make of AC available at site.\n | 4 | Each | |
31 | 25 | S&F rotary type compressor as per existing, suitable for 1.5 TR split type Air conditioner of any make including gas charge & taking out old compressor from outdoor unit of split AC complete all as specified and directed. \nMake : As per existing make of AC available at site.\n | 13 | Each Job | |
32 | 26 | S&F rotary type compressor as per existing, suitable for 2 TR split type Air conditioner of any make including gas charge & taking out old compressor from outdoor unit of split AC complete all as specified and directed. \nMake : As per existing make of AC available at site.\n | 12 | Each Job | |
33 | 27 | S&F squirrel / reciprocating type compressor as per existing, suitable for 3.5 / 4 TR tower type Air conditioner of any make including gas charge & taking out old compressor from outdoor unit of split AC complete all as specified and directed. \nMake : As per existing make of AC available at site.\n | 3 | Each Job | |
34 | 28 | Carrying out cleaning and repair to evaporator / cooling coil of Window type Air conditioner of any capacity and make, making complete unit leak proof by soldering / brazing and straightening of fins complete all as specified and directed.\nNote :- Work shall be incorporated against Sl item No. 1.00 above\n | 20 | Each Job | |
35 | 29 | Carrying out cleaning and repair to condensing unit of Window type Air conditioner of any capacity & make complete all as specified and directed.\nNote:- work shall be incorporated against Sl item No. 1.00 above\n | 12 | Each Job | |
36 | 30 | Supply only swin lever assembly with motor for suitable for window type Air conditioner of any capacity & make complete all as specified and directed.\n | 4 | Each Job | |
37 | 31 | Carrying out repairs to worn out body of Window type Air conditioner of any capacity and make by replacing worn out portion & providing new CRCA sheet, MS angle or strip of appropriate gauge as per existing and fabricating to shape as required including necessary welding, filling of putty, grinding to make the jointed surface even and priming the same with one coat of red oxide primer complete all as specified and as directed.\nMake of Primer :- Jotun India Pvt Ltd / Asian / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd\n | 22 | Per Kg | |
38 | 32 | M&L preparation of old painted surfaces of outer shell cover of Window type Air conditioner of any capacity & make and including applying one coat of synthetic enamel paint & touching up rusted portion only with one coat of red oxide primer complete all as specified and directed.\nMake of Paint:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)\n | 12 | Each Job | |
39 | 33 | S&F factory made shell cover made out of MS sheet of appropriate gauge and GI wire mesh at rear side all as per existing, suitable for 1.5 / 2.0 TR Window type Air conditioner of any make including taking down complete all as specified and directed.\n | 7 | Each | |
40 | 34 | S&F front grill made out of moulded Bakelite / PVC all as per existing, suitable for 1.5 / 2.0 TR Window type Air conditioner of any make including making the unit air tight using PVC sponge 25 thick at all side between wall and shell cover & taking down complete all as specified and directed.\n | 5 | Each | |
41 | 35 | S&F beading at all side of window type air conditioner of any capacity and make, beading made out of 6-10 mm thick & 10-15 cm wide waterproof plywood / wooden plank, duly varnished or painted as per existing including 50 mm long brass screws, brass cup washer and wooden plugs (12 Nos Minimum) & taking down complete all as specified and directed. \n(Average requirement of ply wood /board /plank 0.30 sqm per Window type Air conditioner).\n | 5 | Each | |
42 | 36 | M&L for charging of R-22 Refrigerant gas to 1.5 TR / 2.0 TR Window type Air conditioner after detecting and rectifying leak, flushing with liquid nitrogen, dehydrating and evacuating the system including replacement of drier and capillary tube complete all as specified and directed.\n(To be incorporated against item ser No. 1.00 or at site as per complaints given by the dept.) \n | 50 | Each Job | |
43 | 37 | S&F in repairs 80-100 Mfd starting capacitor suitable for 1.5 TR Window / Split type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.) \n | 30 | Each | |
44 | 38 | S&F in repairs 100-120 Mfd starting capacitor suitable for 2.0 TR Window / Split type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\nMake:-SARADA / Folcon / Universal \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 35 | Each | |
45 | 39 | S&F in repairs 36 Mfd running capacitor suitable for 1.5 / 2.0 TR Window / Split type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\nMake:-SARADA / Folcon / Universal \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 30 | Each | |
46 | 40 | S&F in repairs 40 Mfd running capacitor suitable for 1.5 / 2.0 TR Window / Split type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\nMake:-SARADA / Folcon / Universal \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 25 | Each | |
47 | 41 | S&F in repairs 60 Mfd running capacitor suitable for 1.5 / 2.0 TR Window type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\nMake:-SARADA / Folcon / Universal \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 20 | Each | |
48 | 42 | S&F in repairs 60+5 Mfd dual type running capacitor suitable for 1.5 / 2.0 TR Window / split type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\nMake:-SARADA / Folcon / Universal \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 20 | Each | |
49 | 43 | S&F in repairs 2.5 Mfd capacitor suitable for blower motor of 1.5 / 2.0 TR Window / split type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\nMake:-SARADA / Folcon / Universal \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 20 | Each | |
50 | 44 | S&F in repairs 4.0 Mfd capacitor suitable for blower motor of 2.0 TR Window / split type Air conditioner, 230/440 Volts, 50 Hz, complete all as specified and directed.\nMake:-SARADA / Folcon / Universal \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 20 | Each | |
51 | 45 | S&F in repairs thermostat as per existing suitable for 1.5 / 2.0 TR Window / Split type Air conditioner complete all as specified and as directed. \nMake : Renutral / Annapurna \n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.).\n | 30 | Each | |
52 | 46 | S&F in repairs compressor relay, type 1022 or 1622, suitable for 1.5 / 2.0 TR window / Split type Air conditioner complete all as specified and directed.\nMake:- Renutrol / Annapurna\n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.)\n | 30 | Each | |
53 | 47 | S&F in repairs washable filter, synthetic coil type suitable for Window type Air conditioner of any capacity and make complete all as specified and as directed.\n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.). \n | 30 | Each | |
54 | 48 | S&F in repairs selector switch assembly with knob, suitable for Window type Air conditioner of any make and capacity complete all as specified and directed.\n(To be incorporated against ser item No. 1.00 or at site as per complaints given by the dept.). \n | 13 | Each | |
55 | 49 | Carrying out cleaning and repairs to outdoor unit of Split type Air conditioner of any capacity and make, repair to evaporator / cooling coil, condensing unit, making complete unit leak proof by soldering / brazing and straightening of fins complete all as specified and directed.\n(work shall be incorporated against ser item No. 2.00 above).\n | 90 | Each Job | |
56 | 50 | Supply only swing lever assembly with motor suitable for indoor unit of Split type Air conditioner of any capacity & make complete all as specified and directed.\n | 8 | Each | |
57 | 51 | S&F 1/2'' copper refrigerant pipe, heavy duty including providing fresh thermal insulation cover duly dressed & taking down complete all as specified and directed.\n(Necessary brazing for jointing of pipe is deemed to be included in the item.).\n | 110 | RM | |
58 | 52 | All as per Sl item No. 1.43 above but 1/4" pipe.\n\n | 110 | RM | |
59 | 53 | All as per Sl item No. 1.43 above but 3/8" pipe.\n\n | 110 | RM | |
60 | 54 | All as per Sl item No. 1.43 above but 5/8" pipe.\n\n | 110 | RM | |
61 | 55 | S&F brass connector suitable for 1/2" copper refrigerant pipe complete all as specified and directed.\n | 20 | Each | |
62 | 56 | S&F brass connector suitable for 1/4" copper refrigerant pipe complete all as specified and directed.\n | 20 | Each | |
63 | 57 | S&F brass connector suitable for 3/8" copper refrigerant pipe complete all as specified and directed.\n | 20 | Each | |
64 | 58 | S&F brass connector suitable for 5/8" copper refrigerant pipe complete all as specified and directed.\n | 20 | Each | |
65 | 59 | S&F in repairs thermal insulation as per existing for outer refrigerant pipe of any size including dressing and fixing complete all as specified and directed.\n | 213 | RM | |
66 | 60 | Supply only remote control sensor (power and control) circuit board assembly with remote control hand set as per existing, suitable for Split type Air conditioner of any capacity & make complete all as specified and as directed.\n | 6 | Each | |
67 | 61 | S&F indoor unit as per existing suitable for 1.5 TR split type Air conditioner of any make complete all as specified and as directed.\n | 6 | Each | |
68 | 62 | S&F indoor unit as per existing suitable for 2 TR split type Air conditioner of any make complete all as specified and as directed.\n | 6 | Each | |
69 | 63 | M&L preparation of old painted surfaces of outer shell cover of split type Air conditioner of any capacity & make and including applying one coat of synthetic enamel paint & touching up rusted portion only with one coat of red oxide primer complete all as specified and directed.\nMake of Paint:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)\n | 13 | Each Job | |
70 | 64 | M&L for charging of R-22 Refrigerant gas to 1.5 / 2.0 TR split type Air conditioner after detecting and rectifying leak, flushing with liquid nitrogen, dehydrating and evacuating the system including replacement of drier and capillary tube complete all as specified and directed.\n(To be incorporated against item ser No. 2.00 or at site as per complaints given by the dept.) \n | 40 | Each Job | |
71 | 65 | M&L for charging of R-22 Refrigerant gas to 3.5 / 4.0 TR tower type Air conditioner after detecting and rectifying leak, flushing with liquid nitrogen, dehydrating and evacuating the system including replacement of drier and capillary tube complete all as specified and directed.\n(To be incorporated against item ser No. 3.00 or at site as per complaints given by the dept.) \n | 8 | Each Job | |
72 | 66 | S&F GI bracket 0.05 x 600 mm size for outdoor unit of AC with 08 nos of Fastner / tower bolt and nut with cup washers (300 mm size) including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directeed.\n | 25 | Each | |
73 | 67 | Carrying out cleaning and repair to evaporator / cooling coil / condensing unit of Water cooler of any capacity and make, making complete unit leak proof by soldering / brazing and straightening of fins complete all as specified and as directed.\n(work shall be incorporated against ser item No. 4.00 above).\n | 30 | Each Job | |
74 | 68 | Carrying out repairs to worn out body of Water cooler of any capacity and make by replacing worn out portion & providing new CRCA sheet, MS angle or strip of appropriate gauge as per existing and fabricating to shape as required including necessary welding, filling of putty, grinding to make the jointed surface even and priming the same with one coat of red oxide primer complete all as specified and as directed.\nMake of Primer :- Jotun India Pvt Ltd / Asian / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd\n | 25 | Per kg | |
75 | 69 | M&L preparation of old painted external surfaces of water cooler of any capacity & make and including applying one coat of synthetic enamel paint & touching up rusted portion only with one coat of red oxide primer complete all as specified and directed.\nMake of Paint:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)\n | 7 | Each Job | |
76 | 70 | M&L for charging of R-12 / R-134 Refrigerant gas to water cooler compressor of any capacity & make after detecting and rectifying leak in condensor pipe etc., flushing the system with liquid nitrogen, dehydrating and evacuating the system including replacement of drier and capillary tube complete all as specified and directed.\nNote :- Water cooler’s installed at site but requires changing of gas with serviceable compressor as and when ordered by Engineer-in-Charge.\n | 28 | Each Job | |
77 | 71 | S&F in repairs self closing bib tap, brass chromium plated as per existing, suitable for Water cooler of any capacity & make complete all as specified and directed.\n( To be incorporated against ser item No. 3.00 above or at site complete all as specified and as directed.\n | 11 | Each | |
78 | 72 | S&F in repairs float valve assembly with steel connector and PVC adaptor suitable for water cooler of any capacity & make complete all as specified and directed. \n\n | 11 | Each | |
79 | 73 | S&F in repairs thermostat as per existing suitable for water cooler of any capacity and make complete all as specified and as directed. \nMake : Renutral / Annapurna \n(To be incorporated against ser item No. 3.00 or at site as per complaints given by the dept.)\n | 11 | Each | |
80 | 74 | S&F in repairs compressor relay, type 412L or 412Y, suitable for water cooler of any capacity and make complete all as specified and directed.\nMake:- Renutrol / Annapurna\n(To be incorporated against ser item No. 3.00 or at site as per complaints given by the dept.). \n | 11 | Each | |
81 | 75 | S&F in repairs over load protector, type 412L or 412Y suitable for Water cooler of any capacity and make complete all as specified and directed.\nMake:- Renutrol / Annapurna\nNote:-To be incorporated against ser item No. 3.00 or at site as per complaints given by the dept.\n | 10 | Each | |
82 | 76 | S&F in repairs stainless steel outlet tray as per existing suitable for Water cooler of any capacity & make complete all as specified and as directed.\n | 15 | Each | |
83 | 77 | S&F in repairs 25 mm dia PVC inlet flexible pipe suitable for Water cooler of any capacity & make complete all as specified and directed.\n | 47 | RM | |
84 | 78 | S&F in repairs 32 mm dia PVC outet flexible pipe suitable for Water cooler of any capacity & make complete all as specified and directed.\n | 45 | RM | |
85 | 79 | S&F reciprocating type compressor as per existing, suitable for 40 / 80 Litres Water cooler of any make including gas charge & taking out old compressor complete all as specified and directed. \nMake : As per existing make of water cooler available at site.\n | 3 | Each Job | |
86 | 80 | S&F reciprocating type compressor as per existing, suitable for 60 / 120 Litres Water cooler of any make including gas charge & taking out old compressor complete all as specified and directed. \nMake : As per existing make of water cooler available at site.\n | 6 | Each Job | |
87 | 81 | S&F reciprocating type compressor as per existing, suitable for 150 / 150 Litres Water cooler of any make including gas charge & taking out old compressor complete all as specified and directed. \nMake : As per existing make of water cooler available at site.\n | 4 | Each Job | |
88 | 82 | S&F reciprocating type compressor as per existing, suitable for 1/8 HP for 165/180 Litres Refrigerator of any make including gas charge & taking out old compressor complete all as specified and directed. \n\n | 6 | Each Job | |
89 | 83 | S&F reciprocating type compressor as per existing, suitable for 1/6 HP for 200/310 Litres Refrigerator of any make including gas charge & taking out old compressor complete all as specified and directed. \n\n | 5 | Each Job | |
90 | 84 | S&F reciprocating type compressor as per existing, suitable for 1/6 HP for 310/440 Litres Refrigerator of any make including gas charge & taking out old compressor complete all as specified and directed. \n\n | 5 | Each Job | |
91 | 85 | Replacement of Compressor for Deep Freezer.\n | 4 | Each Job | |
92 | 86 | S&F reciprocating type compressor as per existing, suitable for 300 Litres deep freezer of any make including gas charge & taking out old compressor complete all as specified and directed. \n\n | 5 | Each Job | |
93 | 87 | S&F reciprocating type compressor as per existing, suitable for 500 Litres deep freezer of any make including gas charge & taking out old compressor complete all as specified and directed. \n\n | 5 | Each Job | |
94 | 88 | S&F in repairs thermostat as per existing suitable for Refrigerator / Deep Freezer of any capacity and make complete all as specified and as directed. \nMake : Renutral / Annapurna \n(To be incorporated against ser item No. 6.00 or at site as per complaints given by the dept.)\n | 7 | Each Job | |
95 | 89 | S&F in repairs relay for compressor, suitable for Refrigerator / Deep Freezer of any capacity and make complete all as specified and directed.\nMake:- Renutrol / Annapurna\n(To be incorporated against ser item No. 6.00 or at site as per complaints given by the dept.) complete all as specified and as directed. \n | 6 | Each | |
96 | 90 | S&F in repairs relay for compressor, suitable for Frost free Refrigerator / Deep Freezer of any capacity and make complete all as specified and directed.\nMake:- Renutrol / Annapurna\n(To be incorporated against ser item No. 6.00 or at site as per complaints given by the dept.) complete all as specified and as directed. \n | 5 | Each | |
97 | 91 | S&F in repairs over load protector for compressor suitable for Refrigerator / Deep Freezer of any capacity and make complete all as specified and directed.\nMake:- Renutrol / Annapurna\nNote:- To be incorporated against ser item No. 6.00 or at site as per complaints given by the dept.) complete all as specified and as directed. | 7 | Each | |
98 | 92 | S&F in repairs over load protector for compressor suitable for Frost free Refrigerator / Deep Freezer of any capacity and make complete all as specified and directed.\nMake:- Renutrol / Annapurna\nNote:- To be incorporated against ser item No. 6.00 or at site as per complaints given by the dept.) complete all as specified and as directed.\n | 9 | Each | |
99 | 93 | S&F in repairs cooling coil suitable for Refrigerator / Deep Freezer of any capacity & make complete all as specified and as directed. \nMake :- Renutral /Annapurna\nNote:- To be incorporated against ser item No. 5.00 or at site as per complaints given by the dept.\n | 8 | Each | |
100 | 94 | S&F in repairs cooling coil suitable for Frost free Refrigerator / Deep Freezer of any capacity & make complete all as specified and directed. \nMake :- Renutral /Annapurna\nNote:- To be incorporated against ser item No. 5.00 or at site as per complaints given by the dept.\n | 6 | Each | |
101 | 95 | S&F in reapirs condensing coil suitable for Frost free Refrigerator / Deep Freezer of any capacity & make complete all as specified and directed. \nMake : Renutral /Annapurna\nNote :- To be incorporated against ser item No. 5.00 or at site as per complaints given by the dept\n | 8 | Each | |
102 | 96 | S&F in repairs pigmy lamp thread / pin type suitable for Refrigerator of any capacity & Make complete all as specified and directed. \n | 7 | Each | |
103 | 97 | S&F in repairs Bi metal relay suitable for Frost free Refrigerator / Deep Freezer of any capacity & make complete all as specified and as directed.\nMake : Renutral /Annapurna\nNote:- To be incorporated against ser item No. 5.00 & 6.00 or at site as per complaints given by the dept.\n | 7 | Each | |
104 | 98 | S&F in repairs Printed circuit board (PCB) all as per existing suitable for Frost free Refrigerator / Deep Freezer of any capacity & make complete all as specified and directed.\nMake : Renutral /Annapurna\nNote:- To be incorporated against ser item No. 5.00 or at site as per complaints given by the dept\n | 11 | Each | |
105 | 99 | S&F in repairs heater suitable for Frost free Refrigerator / Deep Freezer of any capacity & make complete all as specified and as directed.\nMake : Renutral /Annapurna \nNote:- To be incorporated against ser item No. 5.00 or at site as per complaints given by the dept\n | 10 | Each | |
106 | 100 | S&F in repairs timer suitable for Frost free Refrigerator / Deep Freezer of any capacity & make complete all as specified and directed.\nMake : Renutral /Annapurna\nNote:- To be incorporated against ser item No. 5.00 or at site as per complaints given by the dept\n | 10 | Each | |
107 | 101 | S&F in repairs lock assembly with key suitable for Refrigerator / Deep Freezer of any capacity & make complete all as specified and directed.\nMake:- Renutral /Annapurna \nNote:- To be incorporated against ser item No. 5.00 or at site as per complaints given by the dept\n | 5 | Each | |
108 | 102 | S&F in repairs hinges suitable for Refrigerator / Deep Freezer of any capacity & make complete all as specified and as directed.\nMake : Renutral /Annapurna \nNote:- To be incorporated against ser item No. 5.00 & 6.00 or at site as per complaints given by the dept.\n | 5 | Pair | |
109 | 103 | M&L for charging of R-12 / R-134-A Refrigerant gas to compressor of Refrigerator / Deep Freezer of any capacity & make complete all as specified and directed.\nNote:- To be incorporated against ser item No. 5.00 & 6.00 or at site\n | 35 | Each Job | |
110 | 104 | S&F in repairs PVC insulated 3 core multistranded sheathed cable with 2.5 Sqmm copper conductor constraction (No/Dia.MM) 50 / 0.25 & current 19 Amps for connection complete all as specified and directed.\nMake:- Havells / Finolex / KEI / Polycab / RR Kabel Ltd.\n | 100 | RM | |
111 | 105 | M & L for sub main wiring with 2 runs of 2.5 Sqmm main wire alongwith 1 run of 2.5 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., including taking down complete all as specified and directed.\nNOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length.\nMake of cable :- Havells / Finolex / KEI / Polycab / RR Kabel Ltd. / HPL\nMake of PVC casing caping:- Presto Plast / Finolex / Kalinga / Payal\n\n | 100 | RM | |
112 | 106 | S&F metal plug and socket DB, double pole 240 volts and including one 20 Amp MCB SPN, C-Curve & including taking down complete all as specified and directed. \nMake :- Legrand / Siemens / ABB / Schneider / Havells / Hager\n | 17 | Each | |
113 | 107 | M&L for shifting / relocation of Window type Air conditioner from one location to another as directed including necessary elecrical connection complete all specified and as directed.\nNote:- Any damage occurred during shifting shall be made good by cotractor at his own cost.\n | 8 | Each Job | |
114 | 108 | M&L for shifting / relocation of split type Air conditioner (indoor and outdoor unit) from one location to another as directed including necessary elecrical connection complete all specified and as directed.\nNote:- Any damage occurred during shifting shall be made good by cotractor at his own cost.\n | 20 | Each Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy