Repair Maintenance Of Summer And Cooling Appliances And Geyser At Vrg Line Me Line Cod Estate Napier Road Harding Road Cod Inside And Dgqa Area Under Ge I Kanpur, Kanpur Cantt-Uttar Pradesh

Military Engineer Services-MES has published Repair Maintenance Of Summer And Cooling Appliances And Geyser At Vrg Line Me Line Cod Estate Napier Road Harding Road Cod Inside And Dgqa Area Under Ge I Kanpur. Submission Date for this Tender is 18-05-2021. Air Conditioner Tenders in Kanpur Cantt Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27714688
Corrigendum : Repair Maintenance Of Summer And Cooling Appliances And Geyser At Vrg Line Me Line Cod Estate Napier Road Harding Road Cod Inside And Dgqa Area Under Ge I Kanpur
National Competitive Bid
Indian
Uttar Pradesh
Kanpur Cantt
18-05-2021

Tender Details

Repair Maintenancne Of Summer And Cooling Appliances And Geyser At Vrg Line Me Line Cod Estate Napier Road Harding Road Cod Inside And Dgqa Area Under Ge I Kanpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-May-2021 Corrigendum Other 11-05-2021
2 11-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 65800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINT OF SUMMER & COOLING APPLIANCES AND GEYSER AT VEG LINE, ME LINE, COD ESTATE, NAPIER ROAD, HARDING ROAD, COD INSIDE AND DGQA AREA UNDER GE (I) KANPUR
Sl. No. Description of Items/Works Item Code / Make Quantity Units
1 1 Repair, maint and making the continuity of supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, water cooler, refrigerator, ACs etc. including providing of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceeding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any accessories found unserviceable that shall be replaced & paid under respective items of this Sch. (ii) Contractor/ supervisor of contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectify on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor 1650 Job
2 2 Disconnecting electrically, taking down existing ceiling/exhasut fan any type and capacity with due care, dismantling blades and handing over to user for repairing from MES with all accessories all as spfd and directed. 855 Job
3 3 Assembling the fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired from users complete with all accessories all as spfd and directed. 855 Job
4 4 Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete and all as specified. Note :- 1. Repairs will be measured and paid separately under respective items. 605 Job
5 5 Rewinding of AC ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block complete and all as specified. 600 Each
6 6 S&F fan capacitor AC 230 volts 4 mfd 50HZ complete and all as specified. Make : Epcos/Usha/Havells. 282 Each
7 7 S&F fan capacitor AC 230 volts 3.15 mfd 50HZ complete and all as specified. Make : Epcos/Usha/Havells. 155 Each
8 8 S&F fan capacitor AC 230 volts 2.5 mfd 50HZ complete and all as specified. Make : Epcos/Usha/Havells. 550 Each
9 9 Supply and fixing in replacement of gun metal bush suitable for any size / model / type of fans complete all as specified & directed. 350 Each
10 10 Repairs, alignment grinding to shaft, remetalling & finishing all as required . 350 Job
11 11 S&F ceiling fan shaft of standard size including taking out old shaft, complete and all as specified. 30 Each
12 12 Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge. Make : SSK cat Pt No 580/Cona cat pt no 3111 or equivalent of make: leader. 80 Each
13 13 Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete and all as specified. 180 Job
14 14 Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified. 180 Job
15 15 Replacement of ball bearing any No suitable for ceiling fan upto 1400mm sweep complete and all as specified Make : SKF/NBC/ABC. 600 Each
16 16 Replacement of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete and all as specified Make : SKF/NBC/ABC. 180 Each
17 17 Cleaning thoroughly ceiling fans 48"/56" (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge 500 Each
18 18 Cleaning thoroughly exhaust/wall/pedestal fan 225 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge 105 Each
19 19 S&F in replacement of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 225 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge. 21 Set
20 20 S&F in replacement of fan blade set plastic suitable for exhaust/ pedestal/air circulator fan 225 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge. 16 Set
21 21 S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site. 65 Set of Three
22 22 S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long. 34 Each
23 23 All as per item No 22 but of size 1 Mtrs long 16 Each
24 24 All as per item No 22 but of size 1.5 Mtrs long 8 Each
25 25 All as per item No 22 but of size 2 Mtrs long 50 Each
26 26 All as per item No 22 but of size 3 Mtrs long 60 Each
27 27 All as per item No 22 but of size 4 Mtrs long 4 Each
28 28 Disconneting & taking down ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep for servicing, strip opening of fan including servicing, cleaning, oiling and greasing complete at site. Re-assembling and refixing to the same/other location. Testing complete after servicing and fixing for smooth and noise free operation. 755 Job
29 29 Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed by Engr-in-Charge. 34 Set of two
30 30 M & L for 40 mm bore galvanised iron tubing medium grade fixed to walls or hanging the fan including making hole and making good the disturbed surface by filling with PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, plastered the surface and match the periodical such as oil bound distemper, white/colour wash etc with exisiting one fcomplete all as specified and directed.Make: Tata/Jindal/Surya Prakash 24 RM
31 31 M & L for 50 mm bore galvanised iron tubing medium grade fixed to walls or hanging the fan including making hole and making good the disturbed surface by filling with PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, plastered the surface and match the periodical such as oil bound distemper, white/colour wash etc with exisiting one fcomplete all as specified and directed.Make: Tata/Jindal/Surya Prakash 21 RM
32 32 M & L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified & directed. Make : Polycab / Finolex / Havells/Plaza/Gloster. 200 RM
33 33 All as per item No 32 but copper cable of size 1.5 Sqmm. 200 RM
34 34 All as per item No 32 but copper cable of size 2.5 Sqmm. 125 RM
35 35 M & L for taking down/out desert cooler from existing place and removing old paint from the body of desert cooler and applying painting on desert cooler external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed. 156 Each Job
36 36 M & L in replacement of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler as per sample complete with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed. 10 Set of three
37 37 M&L in replacement of desert cooler water tank made out of 19 SWG mild steel sheet of size not more than 0.80x0.80x0.20 mtr (approx) to match with existing cooler as per sample including front side panel opening complete with louvers, provision for selector switch, indicator lamp etc and top cover plate made of 22 SWG mild steel along with vertical angle support of suitable height and two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed. 17 Each Job
38 38 Supply and fixing in replacement of water lifting pump submersible type 220 -240 Volts 50 HZ as per sample complete all as specified and directed. Make : Vansal model No OASIS SX6 (Submersible ) or equivalent make as approved by GE. 94 Each
39 39 Supply & fixing in replacement of kit fan motor of desert cooler as per sample, 230 volts complete with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed. Make : Crompton / Havells / Khaitan / Usha. 36 Each Job
40 40 S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed. 120 Set of three
41 41 M & L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto 450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed 27 Each Job
42 42 S & F of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed.\nNote: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint. Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work. Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. 4 Each Job
43 43 M&L for dismantling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as spfd and directed.. 17 Each
44 44 Disconnecting, dismantling old u/s selector switch and fixing with new selector switch as per sample all as spfd and directed. Make Anchor/Kay/Cona 50 Each
45 45 Disconnecting, dismantling old u/s indicator lamps and replaced with new all as spfd and directed. Make Anchor/Kay/Standard 26 Each
46 46 Dismantling old PVC Water distributor four way and refixing with new PVC Water distributor four way as per sample and all as spfd and directed. 50 Each
47 47 S&F in replacement of existing UNSV desert cooler blade as per sample and fix in the desert cooler and all as specified and directed by Engr-in-Charge. Make. Cromton graves. 26 Each
48 48 M&L for disconnecting, dismantling old u/s wiring of desert cooler and replacement with new wiring of selector switches and indication lamps and other as required at site with 1.5 Sqmm single core wires all as spfd and directed. 60 Each
49 49 Disconnecting, dismantling and taking out old u/s storage type water heater geyser of cap 25/35 Ltrs from wall for repair at site all as spfd and directed. 226 Each
50 50 Fixing only storage type water heater geyser on wall after reapir and replacement of old unserviceable with gutties/anchor bolts or nuts & bolts in existing /other location complete all as specified and directed. 226 Each
51 51 M&L for spray painting of outside surfaces of geyser with two coats of white synthetic enamel paint after preparing surface with and including writing MES No. complete all as specified and directed. 40 Each
52 52 M&L for opening the geyser and replacement of glass wool for insulation of geyser of 25 to 50 ltrs capacity of any make / type complete all as specified and directed by Engineer-in-Charge. 40 Kgs
53 53 S&F in replacement of chromium plated flexible copper connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed. 76 Each
54 54 S&F in replacement of PVC flexible connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed. 76 Each
55 55 M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new as per sample with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply as per sample complete all as specified and directed. 200 Each
56 56 M&L for disconnecting, dismantling old u/s heating element of cap 2 KW and replaced with new and testing on completion as per sample complete all as specified and directed by Engineer-in-Charge 80 Each
57 57 All as per item No 56 but heating element of capacity 1.5 KW. 146 Each
58 58 M&L for dismantling old u/s syphon assembly of geyser 25 to 50 ltr capacity and replaced with new stainless steel syphon as per sample and all as spfd and directed/ 36 Each
59 59 M&L for dismantling old u/s inner tank of geyser and replaced with new stainless steel inner tank suitable for 25 to 50 ltrs ltrs capacity geysers of 22 SWG and hydraulically tested at 22.5 PSI pressure maintained at 90 degree centigrade as approved complete all as specified and directed by Engineer-in-Charge. 26 Each
60 60 S&F single pole and neutral enclosure with top pin and earth plug and socket with one SPN MCB 25 Amp 240 Volts, including taking out the existing unserviceable plug top/ plug & socket any type complete all as specified and directed by Engineer-in-Charge.\nMake: Havells Cat part No. DHDMCDPO253025 or its equivalent make of Legrand/ Siemens/ ABB. 20 Each
61 61 S&F in replacement of pressure release valve with inlet coupling of superior quality as approved complete all as specified and directed by Engineer-in-Charge. 30 Each
62 62 S&F in replacement of plug top 15 Amps all as spfd and directed. Make : Cona/Anchor/Havells 40 Each
63 63 S & F in replacement of indicator LED bulb square / round type complete with necessary connection wire of red & green colour all as spfd and directed. 30 Each
64 64 Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed by Engr in charge. 24 Each Job
65 65 Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the window AC of 1.5 / 2 Ton capacity including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas and testing complete all as specified and directed.\nNote: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately if required under respective item of Schedule ‘A’.\n(ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.\n(iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor\n 24 Each Job
66 66 S&F in replacement of cooling coil of window type AC any cap up to 2 ton all as spfd. 6 Each
67 67 S&F in replacement of front grill of window AC suitable for 1.5/2 ton cap as per sample all as spfd and directed. 8 Each
68 68 S&F in replacement of rotary type sealed compressor of window AC 1.5/2 Ton cap as per sample all as spfd and directed. 16 Each
69 69 S&F in replacement of Air blower moter as per sample suitable for window/split type AC of 1.5/2 Ton capacity single phase as per sample all as spfd and directed. 18 Each
70 70 S&F in replacement of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd as per sample all as spfd and directed. 36 Each
71 71 S&F in replacement of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton as per sample. 34 Each
72 72 S&F in replacement of rotary /push type selector switch suitable for window type AC of capacity 1.5 / 2.0 Ton all as spfd and directed. 16 Each
73 73 S&F in replacement of thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity all as spfd. 34 Each
74 74 S&F in replacement of condenser fan blade suitable for window/split type AC of any make & capacity all as spfd and direceted. 32 Each
75 75 M&L for minor denting work to window type air conditioners of 1.5 / 2 Ton capacity including applying spray painting with a coat of synthetic enamel paint of required shade complete all as specified and directed by the engineer -in -charge. 10 Each Job
76 76 Disconnecting electrically and opening the cover of split AC 1.5/2 ton cap inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as directed by Engineer-in-Charge. 74 Each Job
77 77 Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the Split type AC of 1.5 / 2 Ton capacity and fixing only new spares as per model / capacity including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas and testing complete all as specified and directed.\n\nNote: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately under respective item of Schedule ‘A’.\n(ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. 68 Each Job
78 78 S&F in replacement of sealed compressor, rotary type, of any make as per sample suitable for split type AC of 1.5/2 Ton capacity all as spfd and directed. 30 Each
79 79 S&F in replacement of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type all as spfd and directed. 12 Each
80 80 S&F in replacement of discharge grill of outdoor unit of any size and type for split AC’s all as spfd and directed. 9 Each
81 81 Supply and fixing in replacement of defective remote control hand set with "AAA" batteries for window/split type AC's, of any model / make complete all as specified and directed. 12 Each
82 82 Supply and fixing in replacement of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed. 18 Each Set
83 83 Supply and fixing of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed. 34 Each
84 84 Supply and fixing of copper tube as per existing and site requirement complete all as specified and directed. 14 Each Job
85 85 Supply and fixing of condenser / cooling coil for air conditioner of suitable size complete as per site requirement and as directed. 10 Each
86 86 Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remort all as spfd and directed. 20 Each Job
87 87 M&L for fixing/installation of split AC inner/outer or both unit as received from item No 86 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion all as spfd and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required. 18 Each Job
88 88 supply and fixing in replacement of deoxidized annealed copper tube as per sample including brazing etc. complete all as specified and directed. 124 RM
89 89 supply and fixing in replacement of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed. 56 RM
90 90 supply and fixing in replacement of foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed. 30 RM
91 91 S&F in replacement of Main control circuit (PCB) for window/split type AC's, of any model / make complete all as specified and directed. 24 Each
92 92 S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia all as spfd and directed. 60 RM
93 93 M & L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR cap at site / contractor's workshop including any welding / repair work reqd at site complete all as specified and as directed. 22 Each Job
94 94 Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit medium grade of size 20/25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends for drain of AC all as spfd and directed. 50 RM
95 95 Supply and charging refrigerant R-22/R134a/R410 as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and as directed. Make : MEFRON/DUPONT 70 Kgs
96 96 Disconnecting, dismantling old u/s compressor from refrigrator and replaced with new as per sample for the refrigerator of capacity 165 to 310 Ltrs including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. 6 Each
97 97 Supply and fixing in replacement of Starting relay suitable for refrigerator of any make and capacity. Make: Renutrol / Anapurna / Godrej / Whirlpool / LG. 6 Each
98 98 Supply and fixing in replacement of Thermostat suitable for refrigerator of any make and capacity. Make: Indofos / Renutrol / Anapurna / Whirlpool. 8 Each
99 99 Supply and fixing in replacement of PVC freezer door suitable for any size and capacity of the refrigerator. 6 Each
100 100 Supply and fixing in replacement of Magnetic rubber door gasket suitable for any size and capacity of the refrigerator. 4 Each
101 101 Supply and fixing in replacement of Copper liquid line filter two way / one way of refrigrator any type/capacity. 6 Each
102 102 Supply and fixing in replacement of Over load protector of size 1/6 HP to 1/8 HP of refrigrator any type as per site requirement. 4 Each
103 103 Supply and fixing in replacement of Capillary tube as per site requirement of refrigrator/water cooler any type. 4 Each Job
104 104 Supply and fixing in replacement of Bulb of refrigrator any type as per site requirement of Make: Philips / Bajaj. 4 Each
105 105 Supply and fixing in replacement of Ice tray twist type PVC of refrigrator any type. 4 Each
106 106 Supply and fixing in replacement of Freezer of suitable size for refrigerator with door for refrigrator any type. 3 Each
107 107 Supply and fixing in replacement of Condenser cooling coil suitable for refrigerator capacity min 165 ltr to maximum 310 ltrs. 4 Each
108 108 Supply and fixing in replacement of Vegetable basket suitable for refrigerator as per site requirement. 5 Each
109 109 Supply and fixing in replacement of Partition jalli /glass shelf suitable for refrigerator as per site requirement. 8 Each
110 110 Disconnecting, dismantling and taking out old u/s voltage stabilizer of cap 1 to 5 KVA and refixing the same in same/other location after repair incl all minor parts i.e wire, nut, bolt and washers etc all as spfd and directed. Note : Spare parts will be measured and paid seperately under respactive items. 40 Each
111 111 Supply and fixing in replacement of Main relay of voltage stabilizer 1 to 5 KVA as per sample. 44 Each
112 112 Supply and fixing in replacement of Main control circuit (PCB) of voltage stabilizer 1 to 5 KVA as per sample. 40 Each
113 113 Supply and fixing in replacement of replacement of sensor transformer of voltage stabilizer 1 to 5 KVA as per sample. . 14 Each
114 114 Supply and fixing in replacement of voltmeter of voltage stabilizer 1 to 5 KVA as per sample. . 10 Each
115 115 Supply and fixing in replacement of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 KVA as per sample. 7 Each
116 116 Taking out old burnt winding of transformer and re-winding the same with super enameled copper winding wire (existing size) for 1 to 5 KVA voltage stabilizers including all necessary insulating material and testing complete. 14 Each Job
117 117 M & L for painting of voltage stabilizers with a coat of synthetic enamel paint of existing shade after proper cleaning and scraping out old painted surfaces and writing GE (I) Kanpur on voltage stabilizers in block letters with white synthetic enameled paint complete all as specified and directed by the Engineer-in-Charge. 40 Each
118 118 Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed. 36 Each Job
119 119 Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrs for repair all as spfd and directed. 34 Each Job
120 120 M&L for fixing/installation of water cooler any type of cap 40/ 80/ 150 ltrs and making all electrical/water connection and testing all as spfd and directed 34 Each Job
121 121 S&F in replacement of sealed compressor as per sample suitable for water cooler of capacity up to 40 / 80/ 150 Ltrs as per sample. 13 Each
122 122 S&F in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd as per sample for water cooler. 20 Each
123 123 S&F in replacement of Running capacitor 10-30 Mfd as per sample for water coller/ window ac/ split ac/refrigerator. 22 Each
124 124 S&F in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs as per sample. 17 Each
125 125 S&F in replacement of Starting relay of water cooler as per compressor requirement. 20 Each
126 126 S&F in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement. 8 Each
127 127 S&F in replacement of Over load protector of water cooler as per sample suitable for water coolers. 11 Each
128 128 S&F in replacement of PVC flexible pipe transparent 15 / 20 mm dia (as per sample) for water cooler. 40 RM
129 129 S&F in replacement of Push tap long body, cast copper alloy, chromium plated suitable for water cooler of capacity up to 150 ltrs (as per sample). 11 Each
130 130 S&F in replacement of PVC float valve 15 / 20 mm dia with rod & ball for water cooler. Make: Prayag or equivalent. 8 Each
131 131 S&F in replacement of Liquid line filter one way / two way for water cooler. 9 Each
132 132 Supply and fixing in replacement of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed. 7 Each
133 133 S & F in replacement of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed. 5 Each
134 134 M & L for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed. 10 Each
135 135 M & L for minor denting work and applying a coat of spray painting to water cooler with synthetic enamel paint after proper scraping of old rusted painted surface complete all as specified and directed. 5 Each Job
136 136 M & L for replacement of defective sealed compressor unit of 320 / 400 ltr cap deep freezer. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete. 3 Each Job
137 137 S&F of ceiling fan clamps for fixing with fan rod incd nut, bolt, lock pin, rubber real complete all as specified & directed. 50 Each
138 138 S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nut, bolts and washers complete all as specified & directed. 5 Kgs
139 139 M & L for finding out leakage with the pressure testing of the condensor / cooling unit / compressor of deep freezer 320 / 400 Ltr cap including dismantling the same for recharging and stop leakage by brizing / soldering including charging the R-134A gas (or reqd type) to required level and testing the deep freezer for the entire satisfaction of EIC. 3 Each Job
140 140 M & L for Writing SM / MES No. of Summer cooling appliances including Water coolers, desert coolers, refrigerators and Air Conditioners with synthetic enamel paint of Make Asian paints Ltd. Or Stickers equivalent of approved color complete all as specified and directed by Engr-in-Charge. 100 Each Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail