Repair Maintenance Dg Sets T And P Minor B R Repair Of Mes Installation Repair To Rcc Steel Oht Sewage Pumping Installations And Connected Items At Roorkee And Purkazi Under Ge Mes Roorkee, ROORKEE CANTT AND PURKAZI-Uttarakhand

Military Engineer Services-MES has published Repair Maintenance Dg Sets T And P Minor B R Repair Of Mes Installation Repair To Rcc Steel Oht Sewage Pumping Installations And Connected Items At Roorkee And Purkazi Under Ge Mes Roorkee. Submission Date for this Tender is 18-05-2021. Diesel Generators Tenders in ROORKEE CANTT AND PURKAZI Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

27714589
Corrigendum : Repair Maintenance Dg Sets T And P Minor B R Repair Of Mes Installation Repair To Rcc Steel Oht Sewage Pumping Installations And Connected Items At Roorkee And Purkazi Under Ge Mes Roorkee
National Competitive Bid
Indian
Uttarakhand
ROORKEE CANTT AND PURKAZI
18-05-2021

Tender Details

Repair Maintenance Dg Sets T And P Minor B R Repair Of Mes Installation Repair To Rcc Steel Oht Sewage Pumping Installations And Connected Items At Roorkee And Purkazi Under Ge Mes Roorkee

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 56000.0 /-
Tender Value
INR 28 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINTENANCE DG SETS, T&P, MINOR B/R REPAIR OF MES INSTALLATION, REPAIR TO RCC/STEEL OHT, SEWAGE PUMPING INSTALLATIONS AND CONNECTED ITEMS AT ROORKEE AND PURKAZI UNDER GE (MES) ROORKEE.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for carried out 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new for DG Set's of capacity of 250 KVA Make - kirlosker\nNote : \n(a) Spare parts shall be measured and paid separately under respective item of Sch 'A'.\n(b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required. 1 Each\nJob
2 2 S&F of Lubricating Oil filter element with seal 1 Each
3 3 S&F of fuel filter element 2 Each
4 4 S & F of Air filter element 1 Each
5 5 S & F of 'V' belt make Funnder/good year (4PK-1158 EPDM Poly 'V' Belt) 1 Each
6 6 S & F of Hose pipe, including nut, bolts and clamps 1 Each
7 7 S&F Oil bypass filter element with seal 1 Each
8 8 S&F Engine oil as per existing grade 40 Ltr
9 9 M&L for carried out 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new for DG Set's of capacity of 125 KVA to 100 KVA \nNote : \n(a) Spare parts shall be measured and paid separately under respective item of Sch 'A'.\n(b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required. 2 Each\nJob
10 10 S&F of Lubricating Oil filter element with seal 2 Each
11 11 S&F of fuel filter element 4 Each
12 12 S & F of Air filter element 2 Each
13 13 S & F of 'V' belt make Funnder/good year (4PK-1158 EPDM Poly 'V' Belt) 2 Each
14 14 S & F of Hose pipe, including nut, bolts and clamps 2 Each
15 15 S&F Oil bypass filter element with seal 2 Each
16 16 S&F Engine oil as per existing grade 42 Ltr
17 17 S&F fuel water seprater 1 Each
18 18 M&L for carried out 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new for DG Set's of capacity of 62.5 KVA to 63 KVA \nNote : \n(a) Spare parts shall be measured and paid separately under respective item of Sch 'A'.\n(b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required. 14 Each\nJob
19 19 S&F of Lubricating Oil filter element with seal 14 Each
20 20 S&F of fuel filter element 28 Each
21 21 S & F of Air filter element 12 Each
22 22 S & F of 'V' belt make Funnder/good year (4PK-1158 EPDM Poly 'V' Belt) 12 Each
23 23 S & F of Hose pipe, including nut, bolts and clamps 12 Each
24 24 S&F Oil bypass filter element with seal 12 Each
25 25 S&F Engine oil as per existing grade 240 Ltr
26 26 S&F fuel water seprater 2 Each
27 27 M&L for carried out 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new for DG Set's of capacity of 40 KVA to 45 KVA \nNote : \n(a) Spare parts shall be measured and paid separately under respective item of Sch 'A'.\n(b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required. 2 Each \nJob
28 28 S&F of Lubricating Oil filter element with seal 2 Each
29 29 S&F of fuel filter element 4 Each
30 30 S & F of Air filter element 2 Each
31 31 S & F of 'V' belt make Funnder/good year (4PK-1158 EPDM Poly 'V' Belt) 2 Each
32 32 S & F of Hose pipe, including nut, bolts and clamps 2 Each
33 33 S&F Oil bypass filter element with seal 2 Each
34 34 S&F Engine oil as per existing grade 30 Ltr
35 35 M&L for carried out 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new for DG Set's of capacity of 5 to 20 KVA \nNote : \n(a) Spare parts shall be measured and paid separately under respective item of Sch 'A'.\n(b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required. 2 Each \nJob
36 36 S&F of Lubricating Oil filter element with seal 2 Each
37 37 S&F of fuel filter element 2 Each
38 38 S & F of Air filter element 2 Each
39 39 S & F of 'V' belt make Funnder/good year (4PK-1158 EPDM Poly 'V' Belt) 2 Each
40 40 S & F of Hose pipe, including nut, bolts and clamps 2 Each
41 41 S&F Oil bypass filter element with seal 2 Each
42 42 S&F Engine oil as per existing grade 30 Ltr
43 43 M&L for replacement of starting/meter panel including temperature meter, oil pressure meter, push button, air ignition switch with complete wiring and connections as per existing size suitable for 250 KVA DG set all as specified and directed by Engr-in-charge 1 Each Job
44 44 Supply and fix inreplacement of radiator core assembly made out of copper suitable for 250 KVA DG set as per existing size and existing model all as specfied and directed by Engr-in-Charge. 1 Each Job
45 45 M&L for replacement of battery terminal made of brass with necessary brazing to cable 40 Each
46 46 M&L for replacement of battery cable of 70 smm PVC insulated multi stranded copper conductor single core cable with necessary lugs. 50 RM
47 47 Supply & top up inhabitor non corrossive coolent including miexed with distilled water as recommended ratio Make : Castrol, Bosch 100 Ltr
48 48 Supply & top up distillled water for mixing of coolent as per recommended ratio complete all as directed 100 Ltr
49 49 S&F in replacement Battery charger 24 V 10 A panel mounted operating on 230 V single phase 50 Hz supply, by replacing unserviceble charger. 1 Each
50 50 M&L for rewininding the self starter assy 24 Volts by taking out from the DG set capacity 125 /63 KVA , Disnmantling & cleaning , providing proper insulation rewininding with super enamelled copper wire of existing size & insulating the field coil assy replacing bentec assy & fixing back after repairs complete testing all as shown & directed. 2 Each Job
51 51 M&L for rewininding the self starter assy 24 Volts by taking out from the DG set capacity 250 kvaDisnmantling & cleaning , providing proper insulation rewininding with super enamelled copper wire of existing size & insulating the field coil assy replacing bentec assy & fixing back after repairs complete testing all as shown & directed. 1 Each Job
52 52 M&L for rewininding the self starter assy 12 volts by taking out from the DG set any capacity below 100 KVA, Disnmantling & cleaning , providing proper insulation rewininding with super enamelled copper wire of existing size & insulating the field coil assy replacing bentec assy & fixing back after repairs complete testing all as shown & directed. 6 Each Job
53 53 Taking down dynamo 12 volt from any cap DG SET in the exisintg position, dismantling the same and repairing by turning of commutator replacing the armature, carbon brush varnishing the coil reassembling the parts and refixing in position testing and commissioning complete all as specified 2 Each Job
54 54 Taking down battery charging alternator 12 volt from any cap DG SET from the exisintg position, dismantling the same and repairing by rewinding replacing the rectifier plate and avr assy, carbon brush varnishing the coil reassembling the parts and refixing in position testing and commissioning complete all as specified 3 Each Job
55 55 M&L for servicing of DG set panel consisting of relays, contactor 3P, CT 100/5, MCCB, bus bar, ampere meter, volt meter selector switch and phase indication neon lamp, all parts should be cleaning and removing the carbon, tighting the bolts and nuts for all parts including lugs and auxiliary electric connection, replace the rusted/damaged bolts, nuts, washers, phase separtor and lugs incl disconnection the electric supply and making connection suitable for 250 KVA DG Set complete all as specified and directed by Engr-in-Charge\nNote : Minor parts including with this Job and major parts like MCB, MCCB measured and paid separately in respective schedule 1 Each Job
56 56 M&L for servicing of DG set panel consisting of relays, contactor 3P, CT 100/5, MCCB, bus bar, ampere meter, volt meter selector switch and phase indication neon lamp, all parts should be cleaning and removing the carbon, tighting the bolts and nuts for all parts including lugs and auxiliary electric connection, replace the rusted/damaged bolts, nuts, washers, phase separtor and lugs incl disconnection the electric supply and making connection for DG Set 63 KVA to 125 KVA all as specified and directed by Engr-in-Charge\nNote : Minor parts including with this Job and major parts like MCB, MCCB measured and paid separately in respective schedule 6 Each Job
57 57 S&F PVC insulated multistranded copper wire lead for connecting battery of size 25 Sqmm complete all as directed 30 RM
58 58 S&F antivibration pad suitable for 250 KVA DG Set,125 KVA DG Set and 63 KVA DG Sets for mounting DG Sets including removing broken hinges and making good surface for fixing in new hinges compatible for closing and opening and greasing thereafter, complete all as specified and directed 8 Each
59 59 M&L for preparing old metal surface by cleaning, removing old paint by paint remover/scrappers for any width or girth and applying two coats of synthetic enamel paint by spray painting (second coat shall be applied at the interval of one day) of colour as directed by EIC etc. complete all as specified for DG Sets as followings capacity :-
60 60 250 KVA DG set 1 Each Job
61 61 100 KVA TO 125.5 KVA DG Set 2 Each Job
62 62 62.5 KVA TO 63 KVA DG Set 14 Each Job
63 63 40 KVA DG Set 2 Each Job
64 64 15 KVA to 20 KVA DG Set 2 Each Job
65 65 S & F Automatic voltage regulator make- Kirloskar suiutable for 250 KVA DG set 1 Each
66 66 S & F Automatic voltage regulator make- Kirloskar suiutable for 63 KVA DG set 3 Each
67 67 M&L for dismantling of Fuel injection pump cleaned by kerosene oil neatly and kept at suitable place including replacement of defective parts by new parts and machine/drilling work if required reinstallation, reassembling and testing complete. for 250 KVA Note- Defective parts measured and paid separetely in resprctive items here in after 1 Each Job
68 68 M&L for dismantling of Injector assy cleaned by kerosene oil neatly and kept at suitable place including replacement of defective parts by new parts and machine/drilling work if required reinstallation, reassembling and testing complete for 63 KVA to 125 KVA . Note- Defective parts measured and paid separetely in resprctive items here in after \n 5 Each Job
69 69 S&F residential silencer suitable for 125/100 KVA DG set (Make- Ruston/ kirlosker ) 1 Each
70 70 S&F residential silencer suitable for 63 KVA DG set (Make- Ruston/ kirlosker ) 2 Each
71 71 S&F residential silencer suitable for 15/ 40KVA DG set (Make- Ruston/ kirlosker ) 2 Each
72 72 Supply & Fixing Asbestos rope suitable for silencer of DG Set as directed 100 Kg
73 73 Supply and fixing fuel pipe fixing to fuel tank to engine and return fuel engine to fuel tank metal pipe including ferruling & connections nuts/ washer etc 60 RM
74 74 S&F starting unit capacity 12 volt, 32 Ah, compact unit consisting of SMPS charger & lead acid batery all asper Make Cummins Model PULSE ultra Plus ( with SMPS charger ) cat part No AX1013233, complete with inbuilt protection for ensuring optimum charging of batteries and dependeble start for Generators in standby mode, by replacing unserviceble unit .Make - Pulse ultra plus (Cummins) or eqvl in Kirlosker 19 Each
75 75 S&F starting unit capacity 24volt, 32 Ah, compact unit consisting of SMPS charger & lead acid batery all asper Make Cummins Model PULSE ultra Plus ( with SMPS charger ) cat part No AX1013235, complete with inbuilt protection for ensuring optimum charging of batteries and dependeble start for Generators in standby mode, by replacing unserviceble unit .Make - Pulse ultra plus (Cummins) or eqvl in Kirlosker 4 Each
76 76 M & L for Repair and calibiration of FIP for 63/62.5 KVA DG Sets complete 2 Each Job
77 77 M & L for Repair and calibiration of FIP for 5 KVA to 18 KVA DG Sets complete 1 Each Job
78 78 Disconnecting carefully old unserviceable ammeter from panel board and S&F of new 96mm size square/circular digital type ammeter of range 0-30 ampere or 0-300 Ampere, size of letters 25mm, with set of CTs of suitable rating, necessary connectiong/fixing arrangements and testing complete all as specified and directed. make AE or Equivalent 12 Each
79 79 Disconnecting carefully old unserviceable Voltmeter from panel board an S&F of new 96 mm size square/circular digital type Voltmeter of range 0-500 Volt,size of letters 25mm, make -AE (ISI marked), necessary connecting/fixing arrangements and testing complete all as specified and directed 12 Each
80 80 S&F as in replacement of LED type indicating lamps of RYB colours as directed at site on existing panel board including necessary fixing and connecting arrangements complete all as specified and directed 10 Each\n Set
81 81 M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr belwo ground levels with top edge of the earh plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32x6mm earth lead by means ofbolts, nuts, check nuts and washers of galvanised steel all as shown in electric plate No. of SSR Part-I connected to continuous earth wire on main switch board all as specifed or indicated and testing on completion including provision of earth strip protection with 40 mm dia medium grade GI Pipe and watering pipe shall be 20mm bore, medium grade including excavation and earthwork in any type of soil & disposal of soil, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:$ type B-1 cover, reinforced with 8mm TMT bars 100mm C/C both ways with lift hook made out of 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed.\nNote ; The unit rate includes for protection pipe and GI strip from top of earth plate upto 7.5m above ground. 15 Each\n Set
82 82 S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32x6 mm 30 RM
83 83 S&F in replacement of glow sign board box type of size 120 cm x 300cm of acrylic sheet cover in sky blue colour one side display and GI Sheet for back side and made of MS angle frame not less than 40x40x6mm with 02 x LED tube light fittings complete including connecting up with twin core twisted flexible copper conductor cable with suitable size and necessary items for fixing on roof of Pump House & Power House and stnecil of word as reqd with all grouting and PCC work complete all as specified and as directed 6 Each\n Job
84 84 Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M depth in any type of soil and getting out for laying GI strip conductor, stay, poles etc all as specified and directed. 40 Cum
85 85 Returning, filling in including spreading laveling, watering and well ramming in layers not exceeding 25cm in any type of soil all as specified and directed. 22 Cum
86 86 Removing excavated material n.exc. 50M and depositing where directed at a level n.exc. 1.5M above the starting points. 18 Cum
87 87 M&L for clean, dry sand in trenches/ducts for cushioning to cable complete all as specified. 5 Cum
88 88 Supply & laying in trenches sub class `B’ bricks having compressive strength 75 Kg/ Sqcm for cable protection etc compete all as specified and directed by Engineer-in-Charge. 3043 Each
89 89 Supply and laying along the pole/pipe or passing through pipe or laid underground/floor through walls etc, jointing and testing XLPE insulated galvanised steel wire armoured electric cable 1100V grade heavy duty ISI marked with Aluminium conductor of cross sectional area 16 sqmm 2 core. 30 Rm
90 90 All as per item No 89.00 here in before but 95 sqmm 3.5 core 30 RM
91 91 All as per item No 89.00 here in before but 6 qmm 2 core 60 RM
92 92 M&L of GI pipe light grade 50mm dia for cable protection including cold drilling and making good surface as per existing all as directed by Engr-in-Charge 30 Rm
93 93 S & F in replacement of old unserviceable LED Post Top Lantern light fitting 40 watt capacity with transperent diffuser and fixing arrangement on including GI Pipe light grade of dia 40 mm duely grouted on wall/brick pillar complete all as specified and directed at siteand electrical connection from junction box to light fitting complete all as per C&S Cat .LTGLM40WHPLED/W or any equivalent model in Havells/Philips/Wipro. 12 Each
94 94 Supply and fixing in replacement of changeover switch of type Enclosed Automatic Transfer switch (ATS ) Frame 4,400A, 4Pole 400 Amps complete all as specified and directed. Make- L&T cat part No CK 90166BSOO , Havells, 1 Each
95 95 Supply and fixing in replacement of changeover switch of type Enclosed Automatic Transfer switch (ATS ) Frame 2,160A, 4Pole 160 Amps capacity complete all as specified and directed. Make- L&T cat part No CK 90162 BSOO , Havells, 2 Each
96 96 Supply and fixing in replacement of changeover switch of type Enclosed Automatic Transfer switch (ATS ) Frame 2,125A, 4Pole 125 Amps complete all as specified and directed. Make- L&T cat part No CK 90161 BSOO , Havells, 1 Each
97 97 Supply and fixing in replacement of U/S batery with new 12 volts 150 AH lead acid tubular battery complete all as specified and directed. Make- Exide, Amron/ Livefast 13 Each
98 98 M & L for refilling of fire extinguishers of capacity 9 Kg foam / ABC type all as directed at site . Make- Exide, Amron/ Livefast 6 Each\n Job
99 99 M & L for refilling of fire extinguishers of capacity 5 Kg foam / ABC type all as directed at site . Make- Exide, Amron/ Livefast 15 Each\n Job
100 100 M & L for refilling of fire extinguishers of capacity 2 Kg foam / ABC type all as directed at site . Make- Exide, Amron/ Livefast 20 Each\n Job
101 101 Demolition of Brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed . 10 Cum
102 102 M & L for brick work in CM 1:6 using Sub class ‘B’ Bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed. 10 Cum
103 103 Demolition of cement concrete (un-reinforced) of any description and laid in any position complete all as specified and directed. 54 Cum
104 104 M&L 75mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base etc complete all as specified and directed. 360 Sqm
105 105 M&L for 60 mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of M-35 Grade over 20 mm thick sand made with grey cement and pigment complete all as specified and directed. 360 Sqm
106 106 M&L cement concrete Type B-0 1:2:4 (12.5mm graded) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for and the like including weathering, slightly rounded or chamfered angles and throating, as directed 4 Cum
107 107 Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed natural ground complete all as specified and directed. 120 RM
108 108 Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed in Concrete, brick work, masonry, etc ground 120 RM
109 109 Dismantling Barbed wire any description complete all as specified and directed 12 100 RM
110 110 Excavating in post holes in hard/dense soil each n. exc. 0.5 cum getting out , returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm, watering & removing surplus soil to a distance N.exc 50 m and making good surface . 115 Each
111 111 S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165)complete all as specified as directed. 3150 Kg
112 112 Dismantling fencing wire mesh of any type and of any description complete all as specified and directed.\n 640 Sqm
113 113 Supply only Chain link MS galvanisd fencing any size any type complete all as specified and directed. 1152 Kg
114 114 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. 640 Sqm
115 115 S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing & straining and fixed to any type of standard rail incl securing or tying at crossing with and provision of galvanised MS wire staple or steel pins complete all as specified and directed. 12 Per \n100 \nRM
116 116 M & L for 15 mm thick rendering in 1:4 CM stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing surfaces finished even and smooth without using extra cement complete all as specified and directed. \n 100 Sqm
117 117 Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. 1.5 Qtl
118 118 M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 150 Kg
119 119 M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.\n 100 Sqm
120 120 M&L Applying two coats of cement base paint over one coat of primer to wall surface including preparation of newly plastered / untreated surface complete all as specified and directed. 100 Sqm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail