Provn Of Paver Blocks At Various Locations Of Hq 31 Weu And Addn Altn And Renovation To Bldg No P-95 ( Ldgs And Below Md Accn ) At Hq 31 Weu , Thane Under Ge ( Nw ) Mankhurd, GE (NW) MANKHURD-Maharashtra

Military Engineer Services-MES has published Provn Of Paver Blocks At Various Locations Of Hq 31 Weu And Addn Altn And Renovation To Bldg No P-95 ( Ldgs And Below Md Accn ) At Hq 31 Weu , Thane Under Ge ( Nw ) Mankhurd. Submission Date for this Tender is 17-05-2021. Paver Blocking Tenders in GE (NW) MANKHURD Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

27707804
Corrigendum : Provn Of Paver Blocks At Various Locations Of Hq 31 Weu And Addn Altn And Renovation To Bldg No P-95 ( Ldgs And Below Md Accn ) At Hq 31 Weu , Thane Under Ge ( Nw ) Mankhurd
Open Tender
Indian
Maharashtra
GE (NW) MANKHURD
17-05-2021

Tender Details

Provn Of Paver Blocks At Various Locations Of Hq 31 Weu And Addn Altn And Renovation To Bldg No P-95 ( Ldgs And Below Md Accn ) At Hq 31 Weu , Thane Under Ge ( Nw ) Mankhurd

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Apr-2021 AMENDMENT AND REVISED BOQ BOQ 10-05-2021
2 10-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 58000.0 /-
Tender Value
INR 29 Lakhs /-

BOQ Items

Name of Work : PROVN OF PAVER BLOCKS AT VARIOUS LOCATIONS OF HQ 31 WEU AND ADDN/ALTN AND RENOVATION TO BLDG NO P-95 (LDG'S AND BELOW MD ACCN) AT HQ 31 WEU, THANE UNDER GE (NW) MANKHURD
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Surface dressing n.exc 15cm deep and getting out in hard and dense soil etc complete all as specified and directed. 905 Sqm
2 2 M&L for broken stone or boulders hardcore of gauge n.exc 63 mm depositing, spread and levelled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces all as specified and directed 90.5 Cum
3 3 M&L 75 mm thick plain cement concrete type D2, 1:4:8 (using 40 mm graded aggregate) as in sub base of flooring complete all as specified and as directed 905 Sqm
4 4 M&L for pre cast concrete coloured with Lacquere glazed finished external interlocking paver block of M-30 grade , having compressive strength 30 N /mm2, 60mm thick of shade as approved by GE laid dry over 25mm thick sand cushion duly consolidate,set and levelled the block in in proper level with interlocking laid in pavement complete all as specified and directed.\nNote: The rate quoted shall be deemed to be inclusive of sand cushioning. 905 Sqm
5 5 Removing of excavated soil outside MD land exc 1.50km but n exc 5.00km complete all as specified and directed 146.65 Cum
6 6 Taking down cement plaster on brick or concrete surfaces etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed. 75 Sqm
7 7 M&L for rendering 15mm thick on fair faces of brickwork or concrete surfaces in CM 1:6, finished the surfaces even & smooth including 1mm thick sagol finish etc complete all as specified and directed.. 40 Sqm
8 8 M&L for rendering 20mm thick in cement mortar 1:4 on brick or concrete surfaces, on walls, laid in two layers, 1st layer 15mm thick and finishing layer 5mm thick mixed with integral water proofing compound @2 % by weight of cement content of finishing layer, finished fair and even without using extra cement , additional thickness provided as floating/setting coat, including all necessary scaffolding / staging as required etc complete all as specified and directed. 50 Sqm
9 9 Supply only integral water proofing compound 12 Kg
10 10 M & L rendering 5 mm thick in CM 1:3 on ceiling surfaces finished even and smooth including 1mm thick sagol finish etc complete all as specified and directed. 20 Sqm
11 11 Chipping, removing carefully loose/damaged concrete including plastering (total thickness upto 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. \nNote : Hard concrete shall not be removed by force \n 35 Sqm
12 12 M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit, upto 20mm thickness including levelling, profiling etc complete all as specified and directed. 20 Sqm
13 13 M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit while the bonding agent is still sticking, exceeding 20mm thickness and not exceeding 40mm thickness in two layers, each layer not exceeding 20mm, including levelling, profiling etc, complete all as specified and directed. 15 Sqm
14 14 M& L for preparation of newly plastered surface and applying three coat of white wash on ceilings complete all as specified and directed 20 Sqm
15 15 M & L for preparing old decorated surfaces of wall (plasterered or unplastered or previously white washed) & applying two coat of oil bound distemper with wall care putty complete all as specified. 738.95 Sqm
16 16 M & L for preparing old decorated surfaces of ceilings(plastered or unplastered or previously white washed) & applying three coats of whitewash complete all as specified. 251.07 Sqm
17 17 M & L for preparing of wall new plasterer surface & applying two coat of oil bound distemper with wall care putty complete all as specified. 40 Sqm
18 18 M & L for preparation of new plastered surfaces of wall, chajjas, soffits, beam, column etc and applying two coats of 100% anti fungal acrylic exterior emulsion paint over one coat of primer all as per manufacturer's instructions including necessary scaffoldings etc complete all as specified and directed. 50 Sqm
19 19 M&L for complete removal of existing treatment on surfaces of wall chajjas, parapets etc by scrapping, wire brushing, washing down with water and stopping of painted surface including necessary scaffolding and applying two coats of 100% anti fungal acrylic exterior emulsion paint over a coat of primer including preparation of cracked surfaces and removing the loose materials and filled with crack seals of pidilite crack seal or equivalent of STP/Chemistick etc as per manufactures instructions all as specified and directed. \nNote: The contractor shall clean the window panes including splashes of paint etc and the quoted rate is deemed to be included for the same. 457.36 Sqm
20 20 S & F harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc in repairs etc complete all as specified and directed. 40 RM
21 21 S&F in repairs aluminum anodised barrel tower bolts (150 mm ) of extruded section complete all as specified\n 12 Each
22 22 S&F in repairs 300 mm Aluminium alloy , anodised , sliding door bolt with hasp, staple (bolt type ) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified 4 Each
23 23 S&F floor door stopper aluminium body over length of cover plate 140 mm and tonque anodised with hard drawn steel spring fixed in floor complete all as specified and directed. 12 Each
24 24 S&F extruded aluminum alloy handles (150mm ) fabricated type anodised etc complete all as specified and directed. 12 Each
25 25 S&F stainless steel medium weight hinge of size 100 mm etc complete all as specified and directed. 20 Each
26 26 S&F bevelled edge mirror of size 600mmx450mm selected quality mounted on 6 mm thick AC building board commercial ply and fixed to wooden plugs with chromium plated screws and cup washers complete all as specified and directed. 4 Each
27 27 Taking down carefully aluminium sliding window shutters including existing rubber gasket complete and re-fixing the shutters same in existing position after replacement of broken glass/stainless steel wire mesh with rubber gasket and area of window exc 1.20 sqm but not exc 3.78 Sqm in each including necessary scaffolding etc complete all as specified and directed. \nNote: Glass & stainless steel wire mesh will be measured and paid separately 10 Each
28 28 Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fix New locking arrangement in place of old one and re-fixing the same shuters in existing position after repair work or replacement of new locking arrangement and necessary scafolding etc complete all as specified and directed 10 Each
29 29 S & F in repairs aluminium anodised grill DG-104/DG-102 10 mm dia of extruded aluminium section of suitable size and frame including fixing with U clip or F section beading complete with all fitting and fixture and drilling required in RCC section in rectangular or arch type balcony opening of the building etc complete all as specified and directed. 30 Kg
30 30 Supply only 3.00 mm thick plain sheet glass, ordinary quality, in squares not exc 0.5 Sqm each pane etc complete all as specified and directed. 10 Sqm
31 31 S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in repairs with stainless steel wire staples complete all as specified and as directed. 10 Sqm
32 32 Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exceeding 1.5 Sqm each including complete all as specified and directed. 12 Each
33 33 Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) exceeding 1.5 Sqm but not exc 4 Sqm each including complete all as specified and directed. 20 Each
34 34 S& F second class hard wood , plain ,soild ,straight chowkats and frames, wrought , rebated on soild rounded or chamfered , put together with glued pinned at joints etc complete all as specified .and directed 0.3 Cum
35 35 S & F , IInd class Hard wood plain fillets squares, rectangular or triangular in section, wrought, secured with screws, sectional area exc 13 Sqcm and not exc 25 Sqcm complete all as specified and directed. 35 RM
36 36 S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with Square tube, supply and fixing in opening as per specification given under SSR Part II 2020 including making good the disturbed surface all as specified and directed. 40 RM
37 37 M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2020 complete all as specified and directed. 13 Sqm
38 38 S&F 35 mm thick plain , framed ,panelled shutters ( any number of panels),in 2nd class hardwood,with panels of timber flat on both sides (feather edged) ,or of veenered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified. 20 Sqm
39 39 S & F 35 mm thick glazed and skeleton shutters, in 2nd class hardwood, open rebated and prepared to receive glass, gauze etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a) 10 Sqm
40 40 M& L for preparation of newly or previously untreated surfaces of wood or wood based surfaces of any description not other wise described , over10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed. 25 Sqm
41 41 M& L for preparation of old surfaces wood or wood based surfaces of any description not other wise described , over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed. 200 Sqm
42 42 M&L for treating with tar or coal tar black paint on back of chowkats area exc 0.10 Sqm but not exc 0.5 Sqm each complete all as specified. 0.1 100 Nos
43 43 M&L for treating with tar or coal tar black paint on back of chowkats, ends of posts, holdfasts etc. area not exc 0.1 Sqm each complete all as specified. 0.2 100 Nos
44 44 Dismantling floor, hearth or wall tiling including cement mortar, bedding removing serviceable tiles to store and rubbish off the premises all as specified and directed . 268 Sqm
45 45 M&L non skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed. 140 Sqm
46 46 All as per Item No 45.00 here-in-above but screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 on walls surfaces, such as skirting, to slab etc. complete all as specified and as dircted. 10 Sqm
47 47 S& F coloured glazed ceramic tiles 350 x 250 x 7mm/450x350x7mm thick in dado/ skiting etc set and jointed in neat cement slurry and pointed in coloured cement to match, over and incl 10mm thick backing coat in CM 1:4 complete all as specified and directed . 50 Sqm
48 48 M & L for plain cement concrete tiles with grey cement and no pigment 20cm x 20cm x 20mm thick, m a c h i n e pressed set jointed and pointed in neat cement slurry in floors, and cut and polished over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface completed all as specified and directed. 50 Sqm
49 49 M&L for 20 to 25 mm thick machine cut pre-prolished cuddappa stone Slabs (table rubbed and polished) as in cills, jambs etc, pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of stone slab etc, including moulding/rounding to edges of the slab and also over & including provision of 15mm thick screed bed in CM 1:4, complete all as specified and directed. 15 Sqm
50 50 M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including mortar 10mm thick backing coat in CM 1:4 including rubbing and polishing complete all as specified and as directed. 8 Sqm
51 51 M& L for machine cut kota stone slab flooring 20-25 mm thick over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfacey mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed. 10 Sqm
52 52 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed. 10 RM
53 53 M & L for rendering 10 mm thick in CM 1:6 on brickwork or concrete surfaces complete all as specified and directed. 10 Sqm
54 54 S&F in repairs sinks with drainage board made of stainless steel 1 (one) mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm. complete all as specified and as directed 4 Each
55 55 S & F in repairs Vitreous China wash basin, white, flat back, size 580x450 mm including brackets, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe etc complete all as specified and directed. 4 Each
56 56 S&F in repairs 15mm bore bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed.\n 12 Each
57 57 S&F in repairs 15mm bore stop valve cast copper alloy screwed high pressure with crutch or butterfly handle, screwed both end for iron pipe or for union complete all as specified & directed 12 Each
58 58 S&F in repairs 15mm bore pillar taps,chromium plated, cast copper alloy screwed high pressure with crutch or butterfly handle, screwed both end for iron pipe or for union complete all as directed. 4 Each
59 59 S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) in repairs complete all as specified and as directed. 4 Each
60 60 M&L Grating doom 100mm dia of PTMT (Minimum weight 25gms) in repairs complete all as specified and as directed. 10 Each
61 61 Demolition of existing roof terracing of cement concrete (unreinforced) / brick bat coba including water proofing treatment of any thickness & type from roof of G+3 storied building including cleaning surface with wire brush/ mechanical brush and washing with water thoroughly to remove all dust/dirt and loose particles to expose base roof slab and removal of rubbish/demolished material out side MD land etc complete all as specified and directed. \nNote: Breaking of concrete/brick bat coba etc shall be carried out by using pneumatic driller. Hammering & chiseling not allowed. 1 Cum
62 62 M & L for 10mm thick plaster in cement and sand mortar (1:3) finished even and smooth without using extra cement mixed with WPC over roof/ terrace surfaces, complete all as specified and directed, \nNote: WPC shall be measured and paid separately as "supply only". 130 Sqm
63 63 M & L for preparation of existing water proofing treatment and providing and laying ShaliUrethane BTD of STP Ltd or equivqalent, PolyUrethane based for water proofing tratment using high elongation based (>500%) liquid applied elastromeric water proofing membrane with separate wearing course as per ASTM C-836, Thickness of the membrane shall be 1.5mm incl reinforcement. After surface cleaning prime the surface with mixture of Shali Urethane BTD: water 50:50 ratio and apply @ 400gm@ Sqm. After complete drying the surface has to be dampended with coating. Subsequently apply 2 coats of ShaliUrethane BTD by brush or roller on prime surface @ 1Kg/Sqm to get required thickness with non woven FG reinforcement surface complete all as per manufacturer instruction all as specified and directed. 130 Sqm
64 64 Disconnecting of existing tanks up to 1000 litres capacity, stacking safely for re-use (or lowering if required) and hoisting, reconnecting and refixing in position complete all as specified. 4 Each
65 65 Taking up or down 15mm bore steel tubing and connections, including cleaning serviceable pipe for refixing and balance under schedule of credit all as specified and directed 26 RM
66 66 Taking up or down 20mm bore steel tubing and connections, including cleaning serviceable pipe for refixing and balance under schedule of credit all as specified and directed 16 RM
67 67 S&F 15 mm bore GI Steel tubing medium grade with all fitting & fixed complete to walls & ceiling or laid in floors etc complete all as specified and directed. 20 RM
68 68 S&F 20 mm bore GI Steel tubing medium grade with all fitting & fixed complete to walls & ceiling or laid in floors etc complete all as specified and directed. 10 RM
69 69 Fixing only 15 mm bore GI steel tubing medium grade with all fitting & fixing to walls/ceiling or laid in floor etc complete all as specified and directed. 6 RM
70 70 Fixing only 20 mm bore GI steel tubing medium grade with all fitting & fixing to walls/ceiling or laid in floor etc complete all as specified and directed. 6 RM
71 71 Taking down pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc, including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories) 20 RM
72 72 S & F 110mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed. 10 RM
73 73 All as per item No 72.00 above but 75mm dia 10 RM
74 74 S&F PVC (SWR) bends of 110mm bore etc complete all as specified and directed. 2 Each
75 75 All as per Item No 74.00 above but 75 mm dia bend 2 Each
76 76 S & F PVC (SWR) vent cowl of 110mm bore etc complete all as specified and directed. 2 Each
77 77 S&F 75mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal etc complete all as specified and directed. 2 Each
78 78 S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal etc complete all as specified and directed. 2 Each
79 79 S&F 75 mm bore PVC (SWR) branch piece, double (double Y ) equal or unequal etc complete all as specified and directed. 2 Each
80 80 M&L for special treatment of sunken portion of WCs and Bath room as per following stages:\nStage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc .\nStage 2:- Providing 10mm thick plaster in CM 1:4 with chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd\nStage 3:- Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition\nStage 4:- Applying two coats of water proofing decorative elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufacturer instruction\nStage 5:-Again rendering 10mm thick in CM 1:4 mixed with Dr Fixit Pidicrete URP or plaster seal of STP Ltd.\nStage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP. \nStage 7:- Making holes in wall and fixing 600mm long 20mm dia GI light grade pipe spout for draining the surplus water if any. \n 5 Sqm
81 81 M & L for plain cement concrete 1:5:10 Type E2 (using 40mm graded stone aggregate) as in filling in sunken floor etc complete all as specified and directed. 1 Cum
82 82 S & F Wash down water closet (Pedestal pattern), white colour (excluding fixing bolts, flushing cisterns and flush pipe) etc complete all as specified and directed. 4 Each
83 83 S & F in repairs 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. 4 Each
84 84 S & F PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed. 8 Each
85 85 S&F cast iron Nahani trap 100mm dia out let including grating connecting jointing to waste pipe with lead jointing and taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces complete all as specified and as directed . 4 Each
86 86 Dismantling boarding any description fixed in any position with nails complete all as specified and directed . 10 Sqm
87 87 S&F 18/19 mm thick prelaminated particle board both sides with decorative choice lamination, interior grade , of approved shade and pattern fixid with screws to timber frame with beading piece for cupboard and shelves etc complete all as specified and directed. 10 Sqm
88 88 S & F for continuous (piano) hinges, mild steel, bright finish or electro galvanised finish width of flaps 30mm (when open) complete all as specified and directed. 15 Rm
89 89 S & F for 125mm aluminium handles, cast type, anodised complete all as specified and directed. 16 Each
90 90 M & L for Granite (of any type) tiles 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and incl 15mm thick backing coat in CM 1:6 etc complete all as specified and directed. 10 Sqm
91 91 Taking down copper/ aluminum point wiring surface type, concealed type, flame proof type (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc complete all as specified and directed. 122 Point
92 92 M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including casing-caping and accessories, fixed on wall / ceiling etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for one light / fan / bell point controlled by one switch. 70 Point
93 93 -Ditto- all as per item No 92 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches. 16 Point
94 94 -Ditto- all as per item No 92 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board. 24 Point
95 95 All as per item No. 92 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board 12 Point
96 96 S & F Switch Piano, flush type, single pole, one way, 5 Amps, 230 Volts etc complete all as specified and directed. 66 Each
97 97 S & F Bell push flush type 5 amp, 250 Volts etc complete all as specified and directed. 4 Each
98 98 S & F Ceiling Rose, surface bakelite, three terminals, AC, 230 Volts etc complete all as specified and directed. 70 Each
99 99 S & F Switch Socket combination 2 in 1, 5 Amps, 5 pin multipurpose, flush type, 230 Volts etc complete all as specified and directed. 40 Each
100 100 S & F Switch Socket combination 5 in 1, 15 Amps, 6 pin multipurpose, flush type, 230 Volts etc complete all as specified and directed. 12 Each
101 101 S & F Ceiling fan regulator electronic stepped type, AC, 230 Volts, flush type etc complete all as specified and directed. 12 Each
102 102 Supply and fix bell ding dong AC 230 V single pole etc complete all as specified and directed. 4 Each
103 103 S & F in repairs MCB DB 8 way SPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, AC and connecting up etc complete all as specified and directed. 4 Each
104 104 S & F in repairs MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity etc complete all as specified and directed. 4 Each
105 105 S & F in repairs MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity etc complete all as specified and directed. 24 Each
106 106 S&F in repair of LED tube light fitting suitable for 4' (including LED Tube Rod 1 x 20 W), 230V Decorative box type fitting, powder coated top cover, with bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and PVC square blocks for fixing LED Fitting including fixing arrangements and taking down old rusted bracket fittings etc complete all as specified and directed. 34 Each
107 107 M & L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers all as shown in Electrical Plate No.3 of SSR Part-I connected to earthing test point including takingdown old unserviceable earthing alongwith accessories complete with testing etc complete all as specified and directed. 2 Each
108 108 M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade drawn in through non metalic PVC casing caping with and including PVC insulated 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed.\nNote : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. 130 RM
109 109 M&L for sub main wiring with two single core 1.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade drawn in through non metalic PVC casing caping with and including PVC insulated 1.5 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed\nNote : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. 125 RM
110 110 S&F in repair/replacement of building Security light fitting 30/35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings etc complete all as specified and directed. 5 Each
111 111 S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc complete all as specified and directed. 5 Each
112 112 Taking Down Ceiling fans 1200/1400 mm sweep and Exhaust Fan any size transporting to store for safe custody for reuse or for depositing at the MES Yard etc complete all as specified and directed. 12 Each
113 113 Fixing only ceiling fan 1200/1400 mm sweep and Exhaust Fan any size as obtained from taking down vide Ser No 112.00 herein before including painting of celing fan and Exhaust fan etc complete all as specified and directed. 12 Each
114 114 Supply & fix Heavy duty Metallic body Exhaust fan of sweep 300 mm, 900 RPM with frames, blades, mounting anchor fasterners aluminium louvers made of aluminium sheet of 0.5 mm thickness provision of three core 1.5 sqmm copper cable from ceiling rose to fan , making opening of requird size in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4 including scafolding if any required to carry out the work in building of height up to 20 Meters etc complete all as specified and directed. 4 Each
115 115 Supply and fix indoor type vermin and weatherproof totally enclosed cubical type front operated, sufficient ventilation on sides cubicle type fabricated out of 2 mm thick CRCA sheet duly treated with seven tank process and painted epoxy powder coated siemens grey colour and with industrial type built in locking arrangement. The panel shall be indoor type cubical panel board IP 52 free standing floor mounted (CPRI approved manufacturers as per enlisted make only). The panel to be prewired with PVC insulated copper conductors appropriate current carrying capacity for connecting the incoming and out going MCCBs and MCBs. including disconnecting the LT panel and taking down the unserviceable cables and including MCBs. Energy meters of the panel shall be taking down and kept in safe custody for re-installation of site. Disconnecting the incoming and out going cable connection and dismantling the unserviceable conventional type industrial meter board and removing from site for further disposal and making LT UG cable connection complete of suitable size and comprising of following items:-\n(a) INCOMER \n(i) MCCB 40 Amps 415V 16 KA 4 pole - 1 No. \n(b) OUTGOING\n(i) MCB SPN 40 Amps 'C' Series - 4 No. \n(ii) MCB SPN 32 Amps 'C' Series - 2 No. \n(iii) Space for fixing of single phase electronic meter - 5 Nos.\n(c) BUS BAR 100 Amps TPN with colour coded heat shrinkable sleeve\n(d) METERING & INDICATION\ni) Digital VAF meter with selector switch & 3 Nos of CT's -1 Set\nii) Indication lamps for R,Y,B phases -1 Set (Set of Three)\n(e) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled.\n(f) Manufacturer Name plate and Danger notice board written in regional language Hindi and English. \nNote 1. Layout & specification of panels shall be got approved by GE before placing the order. 1 Each
116 116 Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3.5 core including necessary connection and providing cable lugs as required including disconnection/taking down of existing cable all as specified. \n 140 RM
117 117 Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. 19.85 Cum
118 118 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. 8.94 Cum
119 119 M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection etc complete all as specified and directed. 7.94 Cum
120 120 Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches etc complete all as specified and directed. 654 Each
121 121 M&L for cutting existing road/hard standing not exc 45x50 cm in wide & depth getting out excavated material for laying GI tube returning filling & well rammaing watering finish surface 10 cm from top using PCC 1:3:6; including removal of surplus soil etc complete all as specified and directed. 20 RM
122 122 S& F of HDPE type pipe, PN-10, 100 mm dia for laying in ground, road crossing etc for cabe protection including necessary fittings for wall and ducting with required clamps and supports, etc including takingdown old unserviceable existing pipe of any type etc complete all as specified and directed. \nNote 1 : Required Clamps and supports shall be fixed on wall with distance 1.00 RM as directed by Engr-in-Charge.\nNote 2 : A sum of Rs 18,532.00 towards sch of credit shall be deducted to arrive the contract sum.\n 20 RM