Military Engineer Services-MES has published Addn / Altn And Special Repair To Selected Old Md Accn ( Bldg No 107 , 108 , 109 , 110 And 117 ) Of 6Ttr At Ponda ( Goa ) . Submission Date for this Tender is 03-05-2021. Building Repair Tenders in GE panaji Goa Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Apr-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-05-2021 |
Name of Work : ADDN/ALTN AND SPECIAL REPAIRS TO SELECTED OLD MD ACCN (BLDG NO 107, 108, 109, 110 & 117) of 6 TTR, Ponda (Goa) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling floor hearth or wall tiling including cement mortar bedding (But not backing) and disposing off the rubbish materials complete all as specified and directed. | 2430 | Sqm | |
2 | 2 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed. | 4 | Ten Sqm | |
3 | 3 | Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. | 31.125 | Cum | |
4 | 4 | Demolition of RCC concrete of any description and in any position for portion ordered to be dismantled by Engineer in charge complete all as specified and directed. | 10 | Cum | |
5 | 5 | Demolition of cement concrete in sunken portion of water closets exc 15 cm thickness complete all as specified and directed. | 7.6 | Cum | |
6 | 6 | Taking down cement or cement lime plaster of any description from stone/brick or concrete surface of wall/ceiling etc including racking out joints hacking for key scrubbing down with water complete all as specified and directed. | 4750 | Sqm | |
7 | 7 | Taking up or down CI pipes with fittings from wall 100 mm/75mm bore with connections complete all as specified and directed. | 215 | RM | |
8 | 8 | S & F in repair 25mm bore dia galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tee, union, nipple, short pieces etc complete to walls, ceiling or laid in floors complete all as specified and directed. | 160 | RM | |
9 | 9 | S & F in repair Galvanised steel tubing 20 mm bore medium grade with all fittings and fixed complete to walls ceiling or laid in floors complete all as specified and directed. | 170 | RM | |
10 | 10 | S & F in repair Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified and directed. | 180 | RM | |
11 | 11 | Cutting holes into or through brick/ stone walls built in cement mortar or cement lime mortar and making good in CM 1:3 or cement concrete 1:2:4 type B1 as required of superficial area exceeding 150 Sqcm but n.exc 400 Sqcm complete all as specified and directed. | 20 | Per CM of Depth | |
12 | 12 | M&L for rendering 10mm thick in cement mortar (1:3) on surface of concrete junction of wall/sunken portiion of slab finishing with out using extra cement with W.P.C including preparation of old RCC surface by thoroughly cleaning and grouting with cement slurry mixed with water proofing compound all as specified and as directed by the Engr-in-Charge (water proofing compound will be measured separately) | 40 | Sqm | |
13 | 13 | S & F Mild steel flat iron as in hold fast 25x6 mm confirming to Fe 290 Gde E-165 complete all as specified and directed. | 95 | Kg | |
14 | 14 | Cutting holes in brick/stone/concrete walls built in cement mortar for inserting hold fasts depth of embedded portion of hold fast n.exc half brick and making good the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. | 480 | Each | |
15 | 15 | M & L for preparation and treating ends of posts, back of chowkats etc area of tarred exc 0.10 Sqm but n.exc 0.50 Sqm complete all as specified and directed. | 0.8 | 100 Nos | |
16 | 16 | M & L for preparation and treating small articles, area tarred n.exc 0.10 Sqm each such as hold fasts end of posts, back of chowkhats complete all as specified and directed. | 4.8 | 100Nos | |
17 | 17 | M & L glazed ceramic coloured tile 300mmx200mmx6-7mm set & jointed in neat cement slurry and pointed in neat cement slurry and pointed in coloured cement to match over 10mm thick plastering in CM 1:4 as a backing coat complete all as specified and directed. | 775 | Sqm | |
18 | 18 | M & L Coloured non skid ceramic tile 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match,including 15mm thick screed bed in CM 1:6 complete all as specified and directed. | 120 | Sqm | |
19 | 19 | M & L Coloured matt finish ceramic tile 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match,including 15mm thick screed bed in CM 1:6 complete all as specified and directed.\n | 925 | Sqm | |
20 | 20 | S & F in repairs white vitreous china squatting pan orissa pattern of size 580mm x 440 mm, with integral foot rest and WC (SP) Complete in lean concrete fixed in repairs complete all as specified and directed.\n | 20 | Each | |
21 | 21 | S & F PVC (SWR) pipes single socketed in any length fixed to wall or laid under floor of 110 mm dia jointed with solvent cement complete all as specified and directed. | 140 | RM | |
22 | 22 | All as per item No 21 here in before but dia of pipe 75 mm complete all as specified and directed. | 75 | RM | |
23 | 23 | S & F PVC (SWR) bends any radious 110 mm bore complete all as specified and directed. | 40 | Each | |
24 | 24 | All as per item No 23 herein before but bore of pipe 75mm complete all as specified and directed. | 20 | Each | |
25 | 25 | S & F PVC (SWR) branch piece double (double Y) equal or unequal 75mm bore with access door complete all as specified and directed. | 5 | Each | |
26 | 26 | S & F PVC (SWR) branch piece double (double Y) equal or unequal 100mm bore with access door complete all as specified and directed. | 5 | Each | |
27 | 27 | S & F PVC (SWR) branch piece Single (Single Y) equal or unequal 100mm bore with access door complete all as specified and directed. | 5 | Each | |
28 | 28 | S & F 110mm PVC (SWR) WC connector with lipring complete all as specified and directed. | 20 | Each | |
29 | 29 | S & F PVC(SWR) bend with access door any, radius 110 mm bore complete all as specified and directed. | 10 | Each | |
30 | 30 | All as per item No 29 herein before but bore of pipe 75 mm complete all as specified and directed. | 10 | Each | |
31 | 31 | S & F in repair PVC SWR floor trap plain with grating including jointing with solvent cement, dia of outer 75mm complete all as specified and directed. | 20 | Each | |
32 | 32 | S & F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. | 10 | Each | |
33 | 33 | M & L PVC(SWR) Gulty trap 125/110mm setting and jointing with solvent cement including taking out old & making good complete all as specified and directed.\n | 20 | Each | |
34 | 34 | S & F in repair brass cast copper alloy CP Shower rose 125mm size with shower Arm 15mm size 195 mm long with bend complete all as specified and directed.\n\n | 20 | Each | |
35 | 35 | M&L Granite 20 mm (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4 ) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. | 40 | Sqm | |
36 | 36 | M & L Rendering 10mm thick in CM 1:3 on fair faces of concrete surfaces of ceiling, beam bottom, roof projection etc, finished even and smooth without using extra cement including necessary scaffolding for any height etc complete all as specified and directed. | 970 | Sqm | |
37 | 37 | M & L for rendering 15mm thick (in two coats of 10mm under coat and 5mm plaster) on fair faces of brick work/stone or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement for both coats mixed with integral water proofing compound at the rate of 3% by weight of cement all as per manufactures instructions incl necessary scaffolding etc for any height complete all as specified and directed. Note : Water proofing compound will be measured and paid separately | 1360 | Sqm | |
38 | 38 | M & L rendering 15mm thick in CM 1:6 on fair faces of brick/stone wall or concrete surface finished even and smooth without using extra cement complete all as specified and directed. | 2420 | Sqm | |
39 | 39 | M & L for preparation of newly plaster surface and applying two coat of weather proof acrylic emulsion exterior paint over a coat of weather proof acrylic emulsion exterior primer complete all as specified and directed.\nMake- (a) Asian Paint - Apex Ultima Protek. (b) Berger Paint - Weather coat smooth. (c) Nitco Paint - Outshine premium 100% acrylic exterior (d) ICI Dulux - Weather shield exterior. | 1360 | Sqm | |
40 | 40 | M & L preparation of new plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed. | 970 | Sqm | |
41 | 41 | M & L for applying two coat of oil emulsion distemper over a coat of chalk whiting as preparatoy to distemper including prepration of old decorated surfaces of wall by complete removal of existing treatment complete all as specified and directed. | 600 | Sqm | |
42 | 42 | M & L for applying two coat of oil emulsion distemper over a coat of chalk whiting as preparatoy to distemper including prepration of new plaster surfaces of wall by complete removal of existing treatment complete all as specified and directed.\n | 2420 | Sqm | |
43 | 43 | M & L for two coat of white wash on new palstered surface of wall including preparation of surface complete all as specified and directed. | 60 | Sqm | |
44 | 44 | M & L for one coat of white wash on old decorated surface of wall including preparation of surface complete all as specified and directed. | 50 | Sqm | |
45 | 45 | M & L for one coat of white wash on ceiling including preparation of old decorated surface complete all as specified and directed. | 240 | Sqm | |
46 | 46 | M & L for complete removal of existing treatment including preparation surface by washing, rubbing down and applying two coat of weather proof acrylic emulsion exterior paint over a coat of weather proof acrylic emulsion exterior primer complete all as specified and directed. \nMake- (a) Asian Paint - Apex Ultima Protek. (b) Berger Paint - Weather coat smooth. (c) Nitco Paint - Outshine premium 100% acrylic exterior (d) ICI Dulux - Weather shield exterior. | 340 | Sqm | |
47 | 47 | M & L cement concrete Type F2, 1:7:12 (using 40mm graded aggregate) in foundation filling and mass concrete, in sunken portions of WC and for filling cuttings holes created after removing hold fast of old windows, ventilators and doors etc in any position complete all as specified and directed. | 7.6 | Cum | |
48 | 48 | M & L PCC 1:3:6, 75mm thick type C2 as in plinth protection complete all as specified and directed. | 205 | Sqm | |
49 | 49 | S & F bib taps cast copper alloy, fancy type CP with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule and fixed of size 15mm bore in repair complete all as specified and directed. | 80 | Each | |
50 | 50 | S & F stop valves, cast copper alloy 15 mm bore fancy type CP screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete fixed in repairs complete all as specified and directed. | 40 | Each | |
51 | 51 | All as per item No 51 above but stop cock CP with long shank and cup concealed type complete all as specified and directed. | 20 | Each | |
52 | 52 | S & F in repairs PVC flushing cistern 10 ltr capacity high level with inlet ball valve float chain and pull and brackets and flush pipe 32mm dia PVC for low level PVC flushing tank complete all as specified and directed.\n | 20 | Each | |
53 | 53 | S & F in repairs towel rails 60 cm long brass chromium plated 20mm dia with brackets fixed to walls in repairs complete all as specified and directed.\n | 20 | Each | |
54 | 54 | S & F of soap dish vitreous china coloured approximate size (160mmx160mmx90mm) fixed in repairs complete all as specified and directed.\nMake:Neycer Kermag (Standard)/Hindware (Ist Quality)/ Parryware (Super Fine)/ Cera (Ist Quality) /Jaquar | 20 | Each | |
55 | 55 | S & F in repairs PVC connections 15mm size with PTMT nuts, 600mm long complete all as specified and directed. | 40 | Each | |
56 | 56 | S & F in repair 600 x 450mm size mirror of selected quality glass 5mm thick with PVC frame including key hole plates for hanging and fixed to wall with chromium plated screws complete all as specified and directed.\n | 20 | Each | |
57 | 57 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) n.exc, 1.5 Sqm each complete all as specified and directed. | 140 | Each | |
58 | 58 | All as per Sl Item No. 57 here in before but exceeding 1.5 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed. | 160 | Each | |
59 | 59 | Taking down shutters of any description exc 1.00 and n exc 2.00 Sqm each complete all as specified and directed. | 5 | Each | |
60 | 60 | Refixing in same opening shutters of any description exc 1.00 and n exc 2.00 Sqm each complete all as specified and directed. | 5 | Each | |
61 | 61 | S & F solid PVC door frames of size 50mm x 47 mm made out of 5 mm thick plain/printed coloured PVC sheet reinforced with MS square tube all as per specification & drg in SSR Pt II 2004 complete all as specified and directed. | 190 | RM | |
62 | 62 | S & F factory made solid panel PVC door shutter 30mm thick (styles) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cementfor styles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitten in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading & jointed together with solvent cement, complete all as specified and shown in drgs in SSR Pt II 2004 complete all as specified and directed.\n | 55 | Sqm | |
63 | 63 | S & F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. | 3.6 | Cum | |
64 | 64 | S & F 30mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels commercial type on both sides complete all as specified and directed. | 160 | Sqm | |
65 | 65 | S & F 25mm thick factory made Flush shutters (wall cup board shutters), solid core construction, with block board core and plywood face panels commercial type on both sides complete all as specified and directed. | 80 | Sqm | |
66 | 66 | S & F Alu. Anodised barrel tower bolts 150mm long extruded section complete all as specified and directed. | 160 | Each | |
67 | 67 | S & F 100mm long stainless steel butt hinges complete all as specified and directed. | 480 | Each | |
68 | 68 | S & F 75mm long stainless steel butt hinges complete all as specified and directed. | 80 | Each | |
69 | 69 | S & F Alu. Anodised barrel tower bolts of extruded section 100mm long dia complete all as specified and directed. | 80 | Each | |
70 | 70 | Suppy & Fix Alu. Anodised handle 150mm long extruded fabricated type complete all as specified and directed. | 160 | Each | |
71 | 71 | Suppy & Fix Alu. Anodised handle 100mm long extruded fabricated type complete all as specified and directed. | 80 | Each | |
72 | 72 | S & F floor door stopper 150 mm long aluminium alloy body anodized with hard drawn steel spring complete all as specified and directed. | 80 | Each | |
73 | 73 | S&F 75mm Hasp and staple, safety type, aluminium including bolt to hinge plate and fixed with screws | 40 | Each | |
74 | 74 | S & F in repair of aluminium sliding door bolt with hasp & staple bolt type & fixing clips sheet cast of extruded section and fixing bolts 300mm size complete all as specified and directed.\nMake for Item No. 66 to 74: Classic/ Shalimar/ CLIF/ARGET | 160 | Each | |
75 | 75 | S & F Alu wire mesh 0.45 mm nominal dia of wire and width of aperature 1.40mm & fixed with aluminium wire staple complete all as specified and directed. | 185 | Sqm | |
76 | 76 | S & F sheet glass ordinary quality 4mm thick and glazed with oil putty or fixed with beads in square n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer- in-charge. | 150 | Sqm | |
77 | 77 | S & F 3mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in suqares n.exc 0.5 Sqm in each pane complete all as specified and directed.\n | 20 | Sqm | |
78 | 78 | Preparation of new or previously untreated, wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. | 480 | Sqm | |
79 | 79 | Preparation of newly steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. | 200 | Sqm | |
80 | 80 | Preparation of old wooden surface of any description, not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.\nMake for Item No. 78 to 80- Paint- (a) LUXOL (Berger paint) (b) BROLAC (Johnson & Nicholson) (c) SUPERLAC (Shalimar Paints) (d) NEROLAC (Goodlass Nerolac) (e) APCOLITE (Asian Paints)\nPrimer- (a) Berger paint (b) Shalimar Paints (d) Goodlass Nerolac (e) Asian Paints | 100 | Sqm | |
81 | 81 | S & F mild steel frame work confirming to Fe 290 Gde-E-165, such as grills gratings etc, with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, and similar work complete all as specified and directed by Engineer In charge. | 2700 | Kg | |
82 | 82 | Supply only Integral water proofing compound of make IMPERMO/ ACCOPROOF complete all as specified and directed. | 420 | Kg | |
83 | 83 | Dismantling of boarding any description fixed in any position with nails/ screws including cover fillets complete all as specified and directed. | 70 | Sqm | |
84 | 84 | Plugging to walls complete on cement concrete/stone walls for fixing wood fillets/boarding in repair CB, shelves, not exceeding 1 mtr complete all as specified and directed. | 120 | Each | |
85 | 85 | M & L for block boards 18/19 mm thick grade I quality exterior grade commercial type fixed with screw to timber frame work fixed in repairs complete all as specified and directed.\n | 70 | Sqm | |
86 | 86 | M & L for RCC 1: 1.5 : 3 (nominal mix) type A1 , nominal mix with 20mm graded stone aggregates as in slabs staging for water tank, slab supported on walls, beams and columns in floors, roofs landing, balconies, deek slabs and in shelves and the like including necessary formwork and demolition of existing RCC water tank with old staging or slab, RCC cupboards, chajjas, lintels etc. complete all as specified and directed. | 20 | Cum | |
87 | 87 | M & L for TMT bars 10mm dia and over cut to length bent to shape reqd including cranking bending, spirally for hooping for columns, henking end and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. | 375 | Kg | |
88 | 88 | All as per item No. 85 herein before but 6 to 8 mm dia bars as in distribution bars complete all as specified and directed. | 175 | Kg | |
89 | 89 | S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including taking down existing unserviceable PVC water tank and removing clear off site after credit for the same is recovered by the dept complete all as specified and as directed by Engr-in-Charge. \n\n\n | 20 | Each | |
90 | 90 | S & F ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed for bore dia of pipe 25mm complete all as specified and directed.\nMake- Jaypee/ GMP/ Neta/ Zolota/ Prayag polimer/ Symet | 20 | Each | |
91 | 91 | S & F sink made of stainless steel 1mm thick kitchen with plugs, washers and waste coupling including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl use 410mm x 330 mm x 160mm fixed in repair complete all as specified and directed.\n | 20 | Each | |
92 | 92 | M&L rendering 10mm thick on concrete surface in cement mortar 1:4 with using water proofing compund & finishing the surface even & smoth using extra cement. ( Note- Water proofing compund shall be measured seperatly ) | 700 | Sqm | |
93 | 93 | M & L preparation of roof surface by throughly wire brushed, washed, dried up, cleaned of all the foreign matter and dust, and applying bitumenous primer @ 250 gms/sqm, and then laying 3mm thick APP modified bituminous membrane with non woven polyester matt as reinforcement weighting not less than 3.5Kg per sqm, laid on primed surface with torch application method by providing overlap minimum 100mm on logitudinal and 150mm on transerve direction,and finishing the surface with solar reflective bituminous aluminium paint at the rate of 100 grams per sqm with preparation of treated surfaces, all angles and similar projections should be sealed well with extra care to ensure full bondage, all joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR Latex @ 200ml/bag of cement.\nMake- 1.STP Ltd 2 Texsa India Ltd 3 Dr Fixit 4 Tiki Dan | 700 | Sqm | |
94 | 94 | S&F curtain rails 19mm dia anodised aluminium alloy with brackets stops rollers etc fixed in repairs complete all as specified and directed. Note - Bracket will be paid under different item. | 200 | RM | |
95 | 95 | S&F curtain rails brackets etc fixed in repairs complete all as specified and directed. | 180 | Pair | |
96 | 96 | S & F vitreous china wash basin, white flat back size 550 x 400mm including all necessary fitting like brackets,cutting for and pinning in ends of brackets,etc complete; fixed in repairs complete all as specified and directed.\n | 20 | Each | |
97 | 97 | S & F Pillar tap cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe 15mm bore, complete all as specified and directed. | 20 | Each | |
98 | 98 | S & F Waste coupling brass CP 32mm for glazed ware basins etc. with long shanks and fly nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed. | 20 | Each | |
99 | 99 | S & F aluminum anodized window shutter including frame having three track two carries glass shutter and one carries mosqueto net shutter, any type (sliding or open-able ) with frame , & ventilators, other similar work etc fabricated by using the JINDAL / CENTURY section including necessary arrangement for sliding and locking & to receive 4mm thick sheet glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket / rubber beading and all necessary fitting like mortice lock, aluminium tower bolt, handle, stopper, hinges etc complete . But the weight of the rubber gasket / beading will not be measured with weight of aluminium shutter complete all as specified and directed by Engineer in charge. Note :- (i)Sheet glass & wire mesh shall be measured & paid separately.\n | 1898 | Kg | |
100 | 100 | Remove cover and loose concrete from main reinforcement using wooden mallets/wire/brush/ water jet to complete expose the reinforcement in the distressed portion of column, beam, bracings and chajjas etc. (All loose unsound and cracked concrete should be removed) height not exc 7.5m, complete all as specified and directed. | 150 | Sqm | |
101 | 101 | Remove cover and loose unsound cracked concrete clear from main reinforcement using wooden mallet wire brush water jet to completely expose the reinforcrment in the distressed portion of RCC members with out distrubing integrity of structural members at a height exc 7.5m n exc 15m. Including removal of unserviceable materials to a distance exc 50m & not exc 100m complete as directed by EIC | 150 | Sqm | |
102 | 102 | Remove the rust from the reinforcement completely by applying rust removing chemical such as deruster manufactured by M/S OM Agro or any other equivalent as approved by GE but height n exc 7.5m | 150 | 10 RM | |
103 | 103 | Remove the rust from the reinforcement completely by applying rust removing chemical such as deruster manufactured by M/S OM Agro or any other equivalent as approved by GE at a height exc 7.5m n exc 15m. | 150 | 10 RM | |
104 | 104 | M & L for priming reinforcement bars with a coat of NitoZinc primer of M/S Fosroc or any other equivalent as approved by GE(at least 40microns for old and new reinforcement at a height n exc 7.5m.) | 240 | 10 RM | |
105 | 105 | M & L for priming reinforcement bars with a coat of NitoZinc primer of M/S Fosroc or any other equivalent as approved by GE(at least 40microns for old and new reinforcement at a height exc 7.5m n exc 15m.) | 250 | 10 RM | |
106 | 106 | Cleaning the prepared surface finally with air blower to remove dust etc and appyling epoxy based holding material between old and new concrete surface with Nito bond EP of M/S Fosroc or other equivalent make as approved by GE. | 300 | Sqm | |
107 | 107 | M & L for applying shot crete 20mm thick in the proportion of 1:3:1 (cement : coarse sand: 10mm aggregate 50% and 6mm aggregate 50%) while the bond coat is tacky and all as per the manufcturers instructions including provision of hard drawn steel wire fabric 50mm mesh size dia of wire 3mm welding lying on concrete susrfaces after and including applying burning coat at a height exc 7.5m n exc 15m the gunneting pressure at the nosel delivery shall be 2.5kg per Sq cm | 300 | Sqm | |
108 | 108 | S & F Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntweight n exc 4 Kg per Sqm | 500 | Kg | |
109 | 109 | M & L deformed bars 5 mm dia and over upto and including 10 mm dia cut to length shape and welded to the existing reinforcement as additional bars to location where original cross sectional area of existing bar has reduced by 20% by lap welding with an overlap as per relevant IS code of height n exc 7.5m . | 400 | Kg | |
110 | 110 | M & L deformed bars 5 mm dia and over upto and including 10 mm dia cut to length shape and welded to the existing reinforcement as additional bars to location where original cross sectional area of existing bar has reduced by 20% by lap welding with an overlap as per relevant IS code of height exc 7.5m n exc 15m. | 400 | Kg | |
111 | 111 | S&F kitchen plate rack made of steel including fixing with cantilever brackets complete all as specified and directed.\nMake- Prayag 2 Nirali 3 Bluestar (Silver Shine) 4 SPC (Selected Products Co.) | 20 | Each | |
112 | 112 | M&L Chequred cement colured tiles 20x20x25mm thick set & jointed & pointed in neat cement slurry in floors with grey cement and pigments, over 20mm thick screed bed in CM 1:6 complete all as specified and directed.\nMake- 1.M/S Mehatab Tiles, Indore 2 National Tiles 3 Bharat Tiles and Engg Coy, Bangalore 4 Modern Tiles and Marbles Bangalore 5 M/s NITCO, Mumbai 6 Ultra 7 Duracrete | 138.5 | Sqm | |
113 | 113 | M&L for 75mm thick PCC 1:2:4 type B-2 (40mm graded stone aggregate ) as in sub base under floor etc complete all as specified and directed. | 138.5 | Sqm | |
114 | 114 | M&L for machine cut kota stone slab flooring, stair case, landings 20-25mm thick over cement screed bed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and beewax polishing and 20mm thick screed bed in CM 1:6 complete. | 40 | Sqm | |
115 | 115 | M&L for machine cut kota stone slab in riser of steps, skirting, dado 20-25mm thick on vertical wall aurface over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror wax polishing complete with 10mm thick screed bed in CM 1:4 complete all as specified and directed. | 40 | Sqm | |
116 | 116 | Taking down carefully copper/aluminium point wiring of light, fan, socket 5/15A or power point complete including fittings such as switches, ceiling rose, pendant, regulator, socket, lamp holders, brackets, lamp fittings, tube light fittings etc including switch boards and making good disturbed surfaces of wall/ceiling etc so as to match with the existing wall/ceiling/floors etc completely all as directed by Engr-in-Charge. | 515 | Point | |
117 | 117 | Taking down carefully sub main wiring including copper/aluminium/GI earth continuity conductor and making good disturbed surfaces all as directed of any sizes. | 225 | RM | |
118 | 118 | Taking down MCB DBs with MCBs of any size and capacty alongwith teadwood boards incl all fittings/furniture carefully and making good disturbe dsurfaces of wall all as speccified and directed. | 25 | Each | |
119 | 119 | M & L for point wiring with proper colour coding complete with and including PVC insulated ,unsheathed,flexible, bright annealed multi stranded copper conductor single core FRLS cables 1.5sqmm 1100 volts grade drawn through and including heavy grade rigid PVC conduit 20mm or higher dia as required at site ,totally concealed in walls /floors/ceiling and surfaces on trusse by means of saddles & clips etc including all conduit accessoriesc /fiitting/junction box/inspection covers etc of heavy grade ,ISI marked and sunk terminal boxes of factory made 16SWG pressed steel housing ,totally concealed in walls with 3mm thick industrial laminated sheet top cover ,fixed flush with wall surface by means of brass screws and sunk/cupwashers,for mounting of switches ,sockets,fan regulator etc ;including 1.5sqmm 1100 volts grade PVC insulated FRLS ,unsheathed flexible ,multi stranded copper conductor cable as continious earth wire connected to metallic bodies of luminiaries/fan etc at one end to common earth dolly at other end,all as specified and directed For one light point controlled by one switch. | 270 | Point | |
120 | 120 | All as per Item No 119 but For one fan/Exhaust point controlled by one switch. | 80 | Point | |
121 | 121 | All as per Item No 119 but For one bell point, controlled by one switch. | 20 | Point | |
122 | 122 | All as per Item No 119 but For one 5Amp independent socket point controlled by one switch. | 40 | Point | |
123 | 123 | All as per Item No 119 but For one 5A socket point controlled by one switch on same board | 60 | Point | |
124 | 124 | All as per Item No 119 but For one two way light point controlled by two switch | 5 | Point | |
125 | 125 | All as per Item No 119 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. \n | 40 | Point | |
126 | 126 | M & L for switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified | 450 | Each | |
127 | 127 | M&L for Bell push flush type white finish complete all as specified | 20 | Each | |
128 | 128 | M & L for switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified. | 40 | Each | |
129 | 129 | M&L for socket outlet 5 pin, 5 Amps flush type white finish complete all as specified | 100 | Each | |
130 | 130 | S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified | 40 | Each | |
131 | 131 | S&F switch piano 5 Amp flush type single pole two way. | 10 | Each | |
132 | 132 | S&F ceiling rose, surface backlite, 65 x 20 mm three terminal all as specified and directed. | 210 | Each | |
133 | 133 | S&F lamp angle holder insulated body with back plate suitable for angle / batten fitting all as specified and directed. | 100 | Each | |
134 | 134 | S&F Call Bell ding dong type Ac 230 volts single pole complete.\n | 20 | Each | |
135 | 135 | Taking down carefully Ceiling fan of 1200 mm sweep including taking down rod and deposit to E/M store yard at Ponda and S & F Energy efficient BEE Star rated with 3 Star rating ISI Marked with CM/L No ceiling fan of capacity 1200 mm sweep, copper wound , operating on 230 V AC, 50 Hz confirming to IS-374 (Latest) with out regulator and with standard fittings like down rod, Aluminium blades of standard thick ness(1.1 mm), clamps etc complete including provision of 2 core PVC sheathed flexible cable of 23/0.0076 from ceiling rose to ceiling fan all as specified and directed by Engr-in- Charge along with Electronic socket size, rotatory, 5 speed step type regulator, 120-230v white finish. Make- Bajaj/Havells/Crompton | 60 | Each | |
136 | 136 | S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. | 20 | Each | |
137 | 137 | All as per Item No 136 but for vertical typeTPN 4 way, 415 volts | 5 | Each | |
138 | 138 | S&F in replacement testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-series connected with suitable lugs. | 130 | Each | |
139 | 139 | All as per Item No 138 but of TPN 63 Amps, 415V | 5 | Each | |
140 | 140 | All as per Item No 138 but of SPN 16-32 Amps\n | 40 | Each | |
141 | 141 | M&L sub main wiring with two single core PVC-FRLS insulated unsheathed stranded copper conductor cable of size 6 sqmm drawn through and including heavy grade rigid PVC conduit 20mm or higher dia as required at site ,totally concealed in walls /floors/ceiling and surfaces on trusse by means of saddles & clips etc including all conduit accessoriesc /fiitting/junction box/inspection covers etc of heavy grade ,ISI marked with 6 Sqmm PVC-FRLS insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified.\nNote : (i) Two single core cable and one run of earth copper conductor/PVC conduit pipe will be measured and paid as one unit length\n | 225 | RM | |
142 | 142 | M&L for Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 1991 specification. | 5 | Each Set | |
143 | 143 | M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified. | 8 | RM | |
144 | 144 | Supply and fixing of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing complete as required and directed by Engineer-in-Charge.\nMake - (a) Tata (b) Swastik (c) Jindal (d) Surya (e) Prakash (f) Indian Tube Company (g) Zenith (h) BST (j) GST (Gujrat Steel Tube) | 35 | RM | |
145 | 145 | M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site. | 25 | RM | |
146 | 146 | Supply and fix 22 W LED tube light fitting for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver of 22 Watts LED luminaires of make Havell’s cat No LHEXBTP7IN1S022 or equivalent in Bajaj/Crompton/Wipro complete all as specified and directed. | 110 | Each | |
147 | 147 | Material and labour for 30 W LED street light fitting energy saving and environmental friendly long life LED light made up of pressure versatile die-cast aluminium housing with LED as lighting source of capacity 30 W LED 5700 K of make Havells ENDURAPEARLSL30WLED757SASYTOPCMP or equivalent in Crompton/Bajaj/Wipro complete all as specified and directed. | 20 | Each | |
148 | 148 | M&l for bracket made out of GI pipe 25mm dia medium grade, 0.5 mtr long bent to shape with MS flat iron clamps made out of suitabe thick FI nuts, bolts complete all as directed by Engr-in-charge incl. taking down old unsv all as specified and directed.\n | 20 | Each | |
149 | 149 | Material & labour for cutting chases,pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings eps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring ,etc and making good,cutting not exc 10cm girth ON BRICK WALLS. | 400 | RM | |
150 | 150 | Supply and fix LED bulb of 9 watt of Havells Cat Part No LHLDEUEEMC8R009 or equivalent in Bajaj/Crompton greaves/Philips all as specified and as directed. | 100 | Each | |
151 | 151 | Taking down Exhaust fan and deposit to E/M store yard at Ponda. Supply and Fixing exhaust fan ISI marked 300mm sweep AC single phase 230/ 240 V with louvre including three core flexible cable of required length of size 23/0.0076 from ceiling rose/ connector to fan terminal including nut bolt fixed on walls and all other accessories required at site as per requirements all as specified and directed.\nNote: Exhaust will be new provision make Bajaj / Havells / or eqivalent. | 20 | Each | |
152 | 152 | Supply and fix decorative,wall mounting fixture,in durable plastic body and designer mesh in gold finish suitable for B22 type base holder of Havells Cat Part No LHFOAJE1TN1I060 or equivalent make in Crompton, Philips. | 40 | Each | |
153 | 153 | Supply and fix LED bulb of 7 watt of Havells Cat Part No LHLDEUEEMC8R007 or equivalent in Bajaj/Crompton greaves/Philips all as specified and as directed. | 40 | Each | |
154 | 154 | Dismantling old energy meters of any size and capacity alongwith teakwood boards & energy meter keep in safe at MES store for refixing. | 5 | Each Job | |
155 | 155 | Taking down old unserviceable, rusted sheetmetal metering box in any location and any position after disconnection all electrical connections, MCB DB's and Electric meters carefulley and stacking at site for re-use including making good the disturbed surfaces and M & L for new Sheet Metal Enclosure (Meter Box) fabricated out of 2.0 mm thick CRCA sheet, double door type with proper locking arrangement, painted with two coats of acrylic paint over a coat of red oxide paint and partially engraved in the wall, suitable for housing 5 Nos single phase energy meters with prvn of new SMC box with hinge type fitting arrangement moulded in engineering plastic and 01 No VTPN DB and re-fixing the all energy meters and connected accessories including misc items required at site complete all as specified and as directed. \nNote : VTPN DB will be measured and paid seperatly under respective item under Sch 'A'. | 5 | Each | |
156 | 156 | Supply, lay Jointing using suitable lugs and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core including taking down old unserviceable service wire/cable of any size all as specified and directed.\n | 160 | RM | |
157 | 157 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed by Engineer-in-Charge. | 28.8 | CUM | |
158 | 158 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge. | 25.64 | CUM | |
159 | 159 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge. | 3.16 | CUM | |
160 | 160 | Supply and Laying DWC HDPE pipe of outer dia of 50mm and inner dia 40mm polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends complete all as specified and directed. Make: “Rex Polyextrusion Ltd” or equivalent as approved by GE in writing. | 125 | RM | |
161 | 161 | Supply and fix DWC HDPE coupler of dia of 50mm complete all as specified and directed. Make: “Rex Polyextrusion Ltd” or equivalent as approved by GE in writing. | 6 | Each | |
162 | 162 | Supply and fixing galvanised pipe light grade of ISI marked 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and directed Engr-in-charge.\n | 15 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy