Military Engineer Services-MES has published Repair/Replacement And Maintenance Of Connected Items Of Summer Appliances And Lift ( G 5 ) Installed At Sag Building At Metcalfe House Area Under Ge I Rnd Delhi. Submission Date for this Tender is 04-05-2021. Passenger Lift Tenders in DELHI Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Apr-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-05-2021 |
Name of Work : REPAIR/REPLACEMENT AND MAINTENANCE OF CONNECTED ITEMS OF SUMMER APPLIANCES AND LIFT (G+5) INSTALLED AT SAG BUILDING AT METCALFE HOUSE AREA UNDER GE I RND DELHI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | M&L for Servicing of the window type AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position complete all as specified and as directed\n Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be measured & paid seperately under respective items. \n(ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing with proper packing the same shall be deemed to be included in item rate quoted. | 110 | Each | |
2 | 2 | All as per ser item No. 1.00 above but for split type AC/Inverter type AC 1.5/2.0/4.1 Ton. | 320 | Each | |
3 | 3 | All as per ser item No. 1.00 above but for VRF inverter split type 3 phase AC of capacity 8 TR. | 3 | Each | |
4 | 4 | S&F in repair Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC complete all as specified and as directed.\n | 4 | Each | |
5 | 5 | All as per ser Item No. 4.00 above but AC (Window/Split Type). 2.0 TR Capacity | 2 | Each | |
6 | 6 | M&L for Rewinding of Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including insulation materials complete all as specified and as directed. | 7 | Each | |
7 | 7 | S&F in repair Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity complete all as specified and directed. | 6 | Each | |
8 | 8 | S&F in repair Air Filter suitable for AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and as directed. | 6 | Each | |
9 | 9 | S&F in repair Air Filter suitable for AC (Split type) 1.5 TR/2.0 TR Capacity complete all as specified and as directed. \n | 14 | Each | |
10 | 10 | S&F in repair Capacitor Running 36 mfd – 45 mfd suitable for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and as directed. | 35 | Each | |
11 | 11 | S&F in repair Capacitor Starting 80 mfd – 120 mfd suitable for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and as directed. \n | 35 | Each | |
12 | 12 | S&F in repair Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity complete all as specified and directed. | 14 | Each | |
13 | 13 | S&F in repair Fan Motor Capacitor 4 mfd suitable for AC (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed. | 25 | Each | |
14 | 14 | S&F in repair Fan Capacitor 6 mfd for fan motor suitable for (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed. | 25 | Each | |
15 | 15 | S&F in repair Front Plastic Grill (as per Sample) of AC (Window type) 1.5 TR/2.0 TR Capacity complete all as specified and directed. | 5 | Each | |
16 | 16 | S&F in repair front Plastic Grill for inner unit (as per Sample) of AC (Split type) 1.5 TR/2.0 TR Capacity complete all as specified and directed. | 5 | Each | |
17 | 17 | S&F in repair Runner for air blower motor of AC (split type) 1.5/2.00TR capacity (As per sample or as per site requirement) complete all as specified and as directed. | 7 | Each | |
18 | 18 | S&F in repair Single Pole Contactor 25A Capacity, MR 11W type suitable for AC (Split Type) complete all as specified and as directed. | 6 | Each | |
19 | 19 | S&F in repair Selector Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and as directed. | 12 | Each | |
20 | 20 | S&F in repair Selector Switch Knob of AC (Window/ Split Type) 1.5 TR/2.0/3.00 TR Capacity complete all as specified and as directed. | 12 | Each | |
21 | 21 | S&F in repair Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity Complete all as specified and as directed. | 35 | Each | |
22 | 22 | S&F in repair Strainer with Capillary Tube of AC Window/ Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and as directed. | 35 | Each | |
23 | 23 | S&F in repair Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and as directed. | 14 | Each | |
24 | 24 | S&F in repair cooling coil suitable for window type room AC 1.5/2 ton. | 5 | Each | |
25 | 25 | S&F in repair Condensing coil suitable for window type AC 1.5/2 ton | 5 | Each | |
26 | 26 | S&F in repair Condensing coil suitable for split type AC upto 2 Ton capacity. | 5 | Each | |
27 | 27 | S&F in repair cooling coil suitable for split type AC upto 2 ton capacity | 5 | Each | |
28 | 28 | S&F in repair indoor unit suitable for 1.5 TR split type AC complete all as specified and directed. | 5 | Each | |
29 | 29 | S&F in repair outdoor unit suitable for 1.5 TR split type AC complete all as specified and directed. | 5 | Each | |
30 | 30 | S&F in repair Indoor unit suitable for 2 TR split type AC complete all as specified and directed. | 3 | Each | |
31 | 31 | S&F in repair outdoor unit suitable for 2 TR split type AC without compressor complete all as specified and directed. | 3 | Each | |
32 | 32 | S&F in repair of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton. | 12 | Each | |
33 | 33 | S&F in repair of Hermitacally sealed compressor for split/ window type AC capacity 2.0 Ton. | 8 | Each | |
34 | 34 | S&F in repair of Hermitacally sealed compressor for split/ window type AC capacity 3.0 Ton. | 4 | Each | |
35 | 35 | Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), including transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt compressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including re-connection of Electric Connections, functioning AC complete in all respect and testing, complete all as specified and as directed. | 10 | Each Job | |
36 | 36 | All as per Item No. 35.00 above but AC 2.0 TR Capacity (Window/Split Type). | 6 | Each Job | |
37 | 37 | S&F in repair PCB with remote for window type AC up to 2 Ton capacity complete all as specified and directed . | 6 | Each | |
38 | 38 | S&F in repair PCB with remote for Split type AC 2/3(1.5x2) Ton capacity complete all as specified and directed . | 8 | Each | |
39 | 39 | S&F in repair PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity complete all as specified and directed . | 12 | Each | |
40 | 40 | S&F in repair Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) all as specified and as directed. | 8 | Each | |
41 | 41 | S&F in repair wiring kit suitable for 1.5 to 2.0 ton capacity AC complete all as specified and directed. | 30 | Each | |
42 | 42 | S&F in repair gas charging pin valve complete all as specified and directed. | 40 | Each | |
43 | 43 | Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit with proper packing complete all as specified and directed. | 6 | Each Job | |
44 | 44 | Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed. | 10 | Each Job | |
45 | 45 | Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed. | 122 | Kg | |
46 | 46 | All as per ser item No. 45.00 above but R- 410/32 for split type AC up to 2 TR capacity complete. | 122 | Kg | |
47 | 47 | All as per ser item No. 45.00 above but VRF unit 8 TR capacity complete. | 15 | Kg | |
48 | 48 | S&F in repair hermatically sealed compressor for 300 ltrs capacity deep freezer including bracing the sunction and discharge lines coplete all as specified and directged. | 1 | Each | |
49 | 49 | S&F in repair of casing of window type AC of capacity 1.5 TR including company fitted condensing & cooling coil & PCB except compressor complete all as specified and directed. | 6 | Each | |
50 | 50 | S&F in repair of split valve ¼” for split type AC up to 2.00 ton capacity complete all as specified and directed. | 4 | Each | |
51 | 51 | All as per ser item No. 50.00 above but 1/2". | 4 | Each | |
52 | 52 | S&F in repair compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed. | 4 | Each | |
53 | 53 | S&F in repair compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed. | 4 | Each | |
54 | 54 | S&F in repair of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building. | 130 | RM | |
55 | 55 | All as per ser item No. 54.00 above but size 1/2" | 130 | RM | |
56 | 56 | All as per ser item No. 54.00 above but size 3/8" | 130 | RM | |
57 | 57 | All as per ser item No. 54.00 above but size 5/8" | 150 | RM | |
58 | 58 | S&F in repair PVC conduit 20mm dia medium grade including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed. | 100 | RM | |
59 | 59 | S&F in repair PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed. | 100 | RM | |
60 | 60 | S&F in repair of synthetic rubber foam for insulation for refrigerant copper piping of existing size 1/4" to 5/8" internal dia split type AC complete all as specified and directed. \nNote:- The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building. | 400 | RM | |
61 | 61 | S&F in repair Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and directed. | 4 | Each | |
62 | 62 | S&F in repair Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and directed. | 5 | Each | |
63 | 63 | S&F in repair metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed. | 30 | Each | |
64 | 64 | S&F in repair metal enclosures with clad socket & plug top single pole and neutral enclousre with a two pin and earth plug and socket complete including of MCB SP 25 Amps 240 volts complete all as specified and directed. | 30 | Each | |
65 | 65 | S&F in repair metal enclousres with clad socket & plug top triple pole and earth enclousure with a three pin and earth plug with socket complete triple including MCB TP 40 Amps 240 volts complete all as specified and directed. | 10 | Each | |
66 | 66 | S&F in repair of PVC insulated multistranded flexible copper conductor 3 core 1100 Volts grade of size 2.50 Sqmm complete all as specified and directed. \n | 90 | RM | |
67 | 67 | S&F in repair of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all all as specified and directed. \n | 90 | RM | |
68 | 68 | S&F in repair for submain wiring including PVC conduit 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLSH cable drawn through conduit pvc 20mm dia medium duty with all accessories including 4.0 Sqmm single stranded copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and all as specified.\nNote: 3 run 4 Sqmm cable and one run of PVC conduit shall be measured as one unit. | 90 | RM | |
69 | 69 | S&F in repair of AC stand suitable for outdoor AC unit upto 2 ton capacity of size 40x40x6mm of mild steel angle iron including fixing arrangments like welding, fabrication and nuts & bolts etc upto six storey building complete all as specified and directed. | 8 | Each | |
70 | 70 | S&F in repair reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including R/22/R/410 Gas Charging complete all as specified and as directed. | 4 | Each | |
71 | 71 | M&L for taking down Defective Water Cooler 40/80 litre Capacity & transportation from MES Store Yard/Site to Workshop for repair work and back including re-fixing /reinstalling, Testing, connecting the same after replacement of defective/burnt Compressor sealed Unit with new Compressor including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed.\nNote: Compressor shall be procured from the authrised dealer and submit written gurantee of compressor as per manufacturer's | 4 | Each Job | |
72 | 72 | M&L for servicing of water cooler of any make & capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of cooling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed. | 15 | Each Job | |
73 | 73 | Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the system after rectification of all leakages complete all as specifie and directed. | 10 | Each Job | |
74 | 74 | S&F in repair thermostate switch suitalbe for water cooler of any make & size complete all as specified and directed. \n | 6 | Each | |
75 | 75 | S&F in repair starting relay/over load relay suitable for water cooler of any makle & size complete all as specified and directed. | 6 | Each | |
76 | 76 | S&F in repair defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. | 6 | Each | |
77 | 77 | M&L for preparation of old painted surfaces of water cooler upto 150 ltrs capacity by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed. | 8 | Each | |
78 | 78 | S&F in repair fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed. | 3 | Each Job | |
79 | 79 | S&F in repair of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed. | 3 | Each | |
80 | 80 | S&F in repair 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed. | 10 | Each | |
81 | 81 | S&F in repair condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed. | 4 | Each | |
82 | 82 | S&F in repair steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed. | 4 | Each | |
83 | 83 | M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed.\nNote : The rates are inclusive of taking down desert cooler from any height, removal to workshop for painiting and refixing in position after painting. | 80 | Each | |
84 | 84 | M&L for servicing of desert cooler of any size & make including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. \nNote:- Unserviceable parts required for replacement shall be measured and paid separately as supply only under respective items of this schedule. | 80 | Each Job | |
85 | 85 | Supply only desert cooler submersible water pump complete with electric motor single phase 230 volts 50Hz including 3 core cable 1.5 Sqmm multistranded copper conductor, connecting & testing complete all as specified and directed. | 50 | Each | |
86 | 86 | Supply only desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed. | 35 | Each | |
87 | 87 | S&F in repair of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and directed.\nNote: Frame should be in single piece. | 4 | Sqm | |
88 | 88 | Supply only plug top 3 pin 5 Amps. | 50 | Each | |
89 | 89 | Supply only plug top 3 pin 15 Amps. | 30 | Each | |
90 | 90 | Supply only motor capacitor 2.5/3.15/4 mfd. | 50 | Each | |
91 | 91 | S&F in repair front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed. | 20 | Each | |
92 | 92 | S&F in repair of body without side panels made out of galvanised iron sheets of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with one coat of red-oxide primer & 2 coat of synthetic enameled paint including preparation of surface complete with fixing of all spare all as directed. | 15 | Each | |
93 | 93 | S&F in repair body made out of stainless steel sheets of 22 gauge for bottom tank & 20gauge for top cover of water cooler body duly painted with one coat of red-oxide primer & 2 coat of synthetic enameled paint including preparation of surface complete with fixing of all spare all as directed. | 10 | Each | |
94 | 94 | S&F in repair of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with one coat of red-oxide & 2 coat of synthetic enameled paint including preparation of surface complete with fixing of all spare all as directed. | 40 | Each set of three | |
95 | 95 | S&F in repair of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 CUF complete all as directed | 30 | Each | |
96 | 96 | S&F new wood wool pad, (Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed | 80 | Each set of three | |
97 | 97 | S&F in repair of switch piano, flush type single pole, one way, 5 Amp 230 V AC ISI Marked complete all as specifed and directed. | 50 | Each | |
98 | 98 | S&F in repair of aluminium multi wing Fan blade, best quality as per existing type and size suitable for of desert cooler complete all as specifed and directed | 5 | Each | |
99 | 99 | Taking down exhaust/pedestal/air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding/ overhauling/ marking of MES No of fans and fixing the same in eixsting position or as directed by Engineer-in-Charge with eletric connection and testing complete all as specified and directed\nNote:- Rewinding, overhauling shall be measured and paid seperately. | 37 | Each | |
100 | 100 | M&L for taking down and overhauling of ceiling fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed. | 50 | Each | |
101 | 101 | M&L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as directed.\nNote:-\n(a) Defected fans shall be collted from MES store yard and the same shall be deposit after necessary repair.\n(ii) Painting work and replacement of unserviceable ball bearing, rubber reel etc shall be measured & paid under respective item of BoQ. | 50 | Each | |
102 | 102 | All as per ser item No 101.00 above but for exhaust fan of size 300 mm sweep to 380 mm sweep | 20 | Each | |
103 | 103 | All as per ser item No 101.00 above but for exhaust fan of size 450 mm sweep | 10 | Each | |
104 | 104 | All as per ser item No 101.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep. | 2 | Each | |
105 | 105 | All as per ser item No 101.00 above but for table fan/wall mounted of 400 mm sweep | 5 | Each | |
106 | 106 | S&F in repair of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size. | 50 | Each | |
107 | 107 | All as per ser item No 106.00 above but for exhaust fan. | 10 | Each | |
108 | 108 | S&F in repair of rubber reel of suitable size for ceiling fan. complete all as specified and directed | 100 | Each | |
109 | 109 | S&F in repair gun metal bush suitable for any type/model/size of fans complete all as directed. | 20 | Each | |
110 | 110 | S&F in repair of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection all as specified and directed. | 50 | Each | |
111 | 111 | M&L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by spraying machine after filling cavities with filler and preparation of surface complete including marking MES No etc all as specified & directed. | 50 | Each | |
112 | 112 | All as per ser item No 111.00 above but exhaust fan of size 250/300 mm sweep complete all as specified and directed. | 22 | Each | |
113 | 113 | All as per ser item No 111.00 above but for exhaust fan of size 450 mm sweep | 10 | Each | |
114 | 114 | S&F in repair of PVC canopy suitable for 1200 /1400 mm sweep ceiling fan complete all as directed | 20 | Each | |
115 | 115 | S&F in repair voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on + 170 V to 240 V AC, 50Hz single phase all as specified and as directed.\nNote:-\nOld voltage stablizer shall be deposited to AGE E/M Store yard. | 8 | Each | |
116 | 116 | S&F in repair voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on + 170 V to 240 V AC 240 V,50Hz single phase all as specified and as directed. \nNote:-\nOld voltage shall be deposited to AGE E/M Store yard. | 4 | Each | |
117 | 117 | S&F in repair wall mounted fan 450mm sweep working on AC 240 V, 50Hz, single phase all as specified and as directed. \nNote:-\nOld fan shall be deposited to AGE E/M Store yard. | 5 | Each | |
118 | 118 | S&F in repair Pedestal fan 450mm sweep working on AC 240 V, 50Hz, single phase all as specified and as directed. \nNote:-\nOld fan shall be deposited to AGE E/M Store yard. | 5 | Each | |
119 | 119 | S&F in repair exhaust fan PVC body 300mm sweep, 900 RPM working on AC 240 V, 50Hz, single phase all as specified and as directed. \nNote:-\nOld fan shall be deposited to AGE E/M Store yard. | 10 | Each | |
120 | 120 | S&F in repair ceiling fan 1200 mm swep working on AC 240V, 50HZ single phase BEE 5 Star rated all as specified and as directed. \nNote:-\nOld fan shall be deposited to AGE E/M Store yard. | 15 | Each | |
121 | 121 | S&F in repair of water connection CP for inlet & outlet (Hot & Cold) as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. | 15 | Set of two | |
122 | 122 | Taking down of geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc complete all as directed and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position complete all as specified and directed. | 15 | Each Job | |
123 | 123 | All as per ser item No. 122.00 above but capacity 50 ltrs complete all as specified and directed. | 8 | Each | |
124 | 124 | S&F in repair of Heating element triangle/round type as per existing capacity 1.5KW of Hot appliances complete all as specified and directed. | 15 | Each | |
125 | 125 | All as per ser item No. 124.00 above but capacity 2KW complete all as specified and directed. | 10 | Each | |
126 | 126 | S&F in repair thermostate as per existing capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . | 24 | Each | |
127 | 127 | S&F in repair Oil Room Heater 2900 Watt Suitable for 11 Fin,weight 18 Kg with fan complete all as specified and as directed. | 2 | Each | |
128 | 128 | S&F in repair of indicator light (Red & green) as per existing of capacity 25/50 ltrsof hot appliances complete all as specified & directed | 15 | Each set of two | |
129 | 129 | S&F in repair of shut off valve as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. | 20 | Each | |
130 | 130 | S&F in repair of Thermo insulation glass wool as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. | 20 | Each | |
131 | 131 | S&F in repair of heater suitable for double door refrigerator capacity for double door refrigerator capacity 299/310 ltrs complete all as specified and directed. | 2 | Each | |
132 | 132 | S&F in repair of PVC distributors, PVC elbow & PVC pipe best quality 15mm dia for desert cooler complete all as specified and directed. | 10 | Each | |
133 | 133 | S&F in repair angle valves 15mm dia cast copper alloy, screwed down, high pressure, with crutch, but fancy type, chromium plated and fixed complete all as specified and directed. | 10 | Each | |
134 | 133.01 | Note for ser item No. 1 to 133 :-\n1. The contractor shall provide and deploy sufficient technicians with helpers(as directedd by GE / Engineer-in-charge) and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints job card & complete the same complaint detailed by JE E/M/Engineer-in-charge (with in 48 hrs)\n2. The complaints shall be attended with in 48 hrs. If the complaints is/are not attended /not completed on same day (except repair/ replacement of major items like replacement of compressor, cooling coil, condensing coil and fan motor etc.) recovery will be done as follows:- \n(a) After 48 Hrs, Rs.1000/- Per complaint per day. \nThe decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. \n3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. \n4. The contractor has to produce machine number job card duly signed by user duly satisfactory completion of job & JE E/M to Engineer-in-charge before claiming payment. In absence of this Rs. 100/- recovery for per complaint from their dues. | |||
135 | 134 | Repair/maintenance through OEM for lift of capacity luggage lift 1500 KG (G+5 floors) installed at SAG Building in Metcalfe House including all instruments and controlled alongwith replacement of following spare parts including taking down old unserviceable parts including testing and commissioning complete all as specified and directed.\nMake of lift: SKYLARK\nNote: Spare parts shall be measured and paid separately under relevant items as supply only. | 1 | Each Job | |
136 | 134.01 | Supply only SKYLARK DLC Controller with ACVVVF drive. | 1 | Each | |
137 | 134.02 | Supply only SKYLARK Automatic Emergency rescue device. | 1 | Each | |
138 | 134.03 | Supply only SKYLARK Touch sensitive COP (car operated panel) (G+5) in cabin. | 1 | Each Set | |
139 | 134.04 | Supply only SKYLARK Touch sensitive LOP (Landing operated panel (G+1, 2, 3, 4 & 5) in cabin. | 1 | Each Set | |
140 | 134.05 | Supply only SKYLARK friction shoes for CAR-04 Nos. | 1 | Each Set | |
141 | 134.06 | Supply only SKYLARK friction shoes for counter weight-04 Nos. | 1 | Each Set | |
142 | 134.07 | Supply only SKYLARK micro processor controller panel. | 1 | Each Set | |
143 | 134.08 | Supply only new field wiring dedicated to the SKYLARK DLC Controller. | 1 | Each Set | |
144 | 134.09 | Supply only control wiring | 1 | Each Job | |
145 | 134.1 | M&L for overhauling of main machine (motor, gear box, brake shoes, brake shoes lining, lift oil etc. | 1 | Each Job |