Repair Replacement Of Internal Fitting And Fixture Of Em Works To Dgbr And Mohan Enclave Area Under Ge Age Em Of Ge West Delhi Cantt 10, DGBR-Delhi

Military Engineer Services-MES has published Repair Replacement Of Internal Fitting And Fixture Of Em Works To Dgbr And Mohan Enclave Area Under Ge Age Em Of Ge West Delhi Cantt 10. Submission Date for this Tender is 03-05-2021. Electromechanical Work Tenders in DGBR Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

27702400
Corrigendum : Repair Replacement Of Internal Fitting And Fixture Of Em Works To Dgbr And Mohan Enclave Area Under Ge Age Em Of Ge West Delhi Cantt 10
Open Tender
Indian
Delhi
DGBR
03-05-2021

Tender Details

Repair Replacement Of Internal Fitting And Fixture Of Em Works To Dgbr And Mohan Enclave Area Under Ge Age Em Of Ge West Delhi Cantt 10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Apr-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
INR 49.50 Lakhs /-

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF INTERNAL FITTING FIXTURES OF E/M WORKS TO DGBR AND MOHAN ENCLAVE AREA UNDER AGE E/M (WEST) OF GE (WEST) DELHI CANTT-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) complete such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing complete all as specified and directed. 1000 Per point
2 2 M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable(phase,neutral and earth wire)in and including surface PVC Casing Caping ISI marked of suitable size medium grade with PVC fittings such as tees, bends, elbow, reducers etc. earth wire, connecting to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing modular switches/sockets etc with modular type cover plate 3mm thick plastic laminated sheet for one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push complete all as specified and directed. \nNote : The cost of Metal boxes including concealed in wall and moduler cover plates etc will be included in quoted rate. 300 Per point
3 3 All as per item no. 2 here-in-before but for one socket outet point 5 amps on the same board complete all as specified and directed. 50 Per point
4 4 All as per item no. 2 here-in-before but for one socket outet point 5 amps on the independent board complete all as specified and directed. 100 Per point
5 5 All as per item no. 2 here-in-before but for one light point controlled by two nos of 2 way switch complete all as specified and directed. 10 Per point
6 6 All as per item no. 2 here-in-before but with 3x 2.5 sq mm (Nominal area) FRLS PVC insulated unseathed and stranded copper wire conductor cable (phase ,neutral and earth wire) for 15 Amp power point complete all as specified and directed. 90 Per point
7 7 M&L for concealed point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable(phase,neutral and earth wire)in and including PVC concealed conduit ISI marked of suitable size medium grade with PVC conduit fittings such as tees, bends, elbow, reducers including cutting chasing and making good to disturbed surface , earth wire, connecting to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing modular switches/sockets etc with modular type cover plate 3mm thick plastic laminated sheet for one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push complete all as specified and directed.\nNote : The cost of cutting chasing for concealed wiring in wall /floor and including Metal boxes concealed in wall and moduler cover plates etc will be included in quoted rate. 200 Per point
8 8 All as per item no. 7 here-in-before but for one socket outet point 5 amps on the same board complete all as specified and directed. 50 Per point
9 9 All as per item no. 7 here-in-before but for one socket outet point 5 amps on the independent board complete all as specified and directed. 100 Per point
10 10 All as per item no. 7 here-in-before but with 3x 2.5 sq mm (Nominal area) FRLS PVC insulated unseathed and stranded copper wire conductor cable (phase ,neutral and earth wire) for 15 Amp power point complete all as specified and directed. 100 Per point
11 11 S & F in repair Modular switch 6 Amp, 1 way, 1 module size complete all as specified and directed. 800 Each
12 12 S & F in repair Modular switch 6 Amp, 2 way, 1 module size complete all as specified and directed. 20 Each
13 13 S & F in repair Modular switch 16 Amp, 1 way, 1 module size with indicator lamp ccomplete all as specified and directed. 200 Each
14 14 S&F in repair bell push, Moduler type, 5 Amps complete all as specified and directed. 50 Each
15 15 S&F in repair Bell, AC 230 Volts, single pole complete all as specified and directed. 50 Each
16 16 S & F in repair modular socket two-in-one, 6 Amp universal type, 02 module size complete all as specified and directed. 300 Each
17 17 S & F in repair modular Socket, 16 Amp, multipurpose shutter type, 02 module size complete all as specified and directed. 190 Each
18 18 S & F in repair Modular Fan regulator step type, 120 watts, 2 Module , 5 step complete all as specified and directed. 100 Each
19 19 S&F in repair lamp holder insulated body and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed. 100 Each
20 20 S&F in repair Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed. 500 Each
21 21 Takig down of celing fan and exhaust fan and Hanging /Re-fixing connecting up after repair including provision of cable from ceiling rose or connector to fan complete all as specified and directed. 500 Each
22 22 M&L for rewinding of ceiling fans 1200mm /1400mm of any type and make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge and quantity, both sides of rewinding covered with high quality varnish complete including replacement of ball bearing as requirment of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep complete all as specified and directed. 350 Each
23 23 M&L for rewinding of exhaust fan / ventilating fan /circular fan of 300mm / 250mm sweep of any type & make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge & qunatity, both sides of rewinding locked with high quantity varnish complete inclusion of ball bearing of SKF/NBC make and provisions of new nuts pin all as specified & directed. 150 Each
24 24 M&L for painting of ceiling fans 1200mm/1400m complete in situ with synthetic enamel paint of white colour by spraying including filling cavities with filler ,one coat after cleaning all dust etc complete all as specified and directed 350 Each
25 25 Supply and fixing replacement of capaciator 2.50/3.15 Mfd, 240 V complete all as specified and directed. 350 Each
26 26 Supply & fix celing fan blades(03Nos 1 set) for 1200/1400 mm sweep ceiling fans complete all as specified and directed. 100 Each Set
27 27 Supply and fixing in repair of inner shell of steel body suitable for 25Ltrs capacity of geyser including taking down, descaling, replacement of Gasket and any other minor repair for geyser made serviceable and testing complete all as directed by Engr-in-Charge as per existing pattern complete all as specified and directed. \n 100 Each
28 28 S& F in repair copper heating element 1500 watt embedded copper, sheathed tubular with theremostat casing cap triangular/Round type of IS : 4159 complete all as specified and directed. 300 Each
29 29 S&F in replacement thermostat suitable for Geyser capacity 25Ltr water temperature 30° to 75° C electric cut up for any type of water heater complete all as specified and directed. 300 Each
30 30 S & F in replacement copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed. 150 Each
31 31 Supply and fixing in replacement outer body dully powder coated by white paint suitable for water heater 25Ltrs capacity of geyser including taking down old one , replacement of Gasket and any other minor repair for geyser made serviceable and testing complete all as directed by Engr-in-Charge. 50 Each
32 32 S&F single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. 50 Each
33 33 Supply and fixing PVC Connection 600 mm long complete all as specified and directed. 200 Each
34 34 S & F in repair Flush/ surface mounted neon indicator lamp in colours red and green complete all as specified and directed. 50 Each
35 35 S & F in repair Glass wool for geyser insulation complete all as specified and directed. 10 kg
36 36 S & F in repair Air reliese valve for water Heater complete all as specified and directed. 50 Each
37 37 S&F in repair of non return brass valve 15mm bore complete all as specified and directed. 50 Each
38 38 S&F in repair of EPDM gasket complete all as specified and directed. 50 Each
39 39 Supply and fixing in replacement of solar panel collector complete all as specified and directed.\nMake: Supremen or equivalent as approved. 50 Each
40 40 S&F in repair of hose pipe 25 mm dia & 18" long complete all as specified and directed. 50 Each
41 41 S&F in repair of sacrificial anod complete all as specified and directed. 100 Each
42 42 Supply and laying in repair CPVC pipe of 25 mm outer dia including fittings & taking down old pipe complete all as specified and directed. 200 RM
43 43 S & F in repair copper Heating element 3KW for solar water heater embeded copper sheathed tubular with casing cap triangular/round shape. 50 Each
44 44 S&F in repair of factory made epoxy polyester powder coated distribution board 8 way SPN DB-507611 fabricated from minimum 1.2 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed.\nNOTE \n(a) MCBs SP ,SPN shall be measured and paid separately.\n(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed fit included in item rate 40 Each
45 45 Supply & Fix in repair factory made epoxy polyester powder coated distribution board 4 way VTPN DB-507745 with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB all as specified.NOTE :-\n(a) MCCB /MCBs shall be measured and paid separately.\n(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed fit included in item rate 10 Each
46 46 Checking and attending complaints with one electritian and one helper in HQ DGBR office Complex and JCOs /ORs OTM Accn complex area in Narayna means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and directed. Note : 1 The electrician deployed by the contractor shall have ITI /03 years expreince certificate in concerned trade.Helper deployed shall be min 8th pass with min 03 years expriance in relevant trade.2. This item covers only cost of labour for attending complaint and taking down of old material. 3. Item to be replaced under this item shall be either isued free for fixing under schedule 'B'or shall be contractor supply under respective items of this schedule as decided by Enge-in -charge.Decided of GE in this regard shale be found and bonding.4. Complaints noted'' NO Light'' shall be attended imediately up to 2200 hrs without fail,failing which recovery of Rs.240/ per complaint shall be effected from the RARs/ F Bill.5. Minor items as PVC wire of any size as per requirement up to 1.0m length,thimble,electric tape etc shall deemed to be included in the quoted rate of this items.6.The complaints shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be leived/imposed on the contractor and recovery shall be made from his dues.7. Contracror shall arrange suitable T&P incl necessary from work and scoffolding and safety measures to make it functional complete all as specified and directed.8. Contractor or his rep will report daily at complaint cell for collection of complaints fromthe concerned JE's incharge,in case after checking& attending the defects, if it is not possible to rectfy the defects within 08 hrs, the facts shall be brought to the notice of Engeer in charge by the contractor/his rep immediately. If Engr -in -chargr is satisfied with contractor's view, no recovery will be made on this account.9.Labour charges for this item shall not be included under items which includes 'M&L','S&F' in repair',fixing only /Fixing in repair etc in respective item of this Schedule/BOQ. 4500 Each Complaint
47 47 S&F in replacement MCCB, 415 volts, four pole of cap 63 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Metreinals / thimble of suitable size and making connections complete all as specified and directed. 20 Each
48 48 S&F in replacement MCCB, 415 volts, four pole of cap 100 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Metreinals / thimble of suitable size and making connections complete all as specified and directed. 8 Each
49 49 S&F in replacement MCCB, 415 volts, four pole of cap 125 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Metreinals / thimble of suitable size and making connections complete all as specified and directed. 8 Each
50 50 S&F in replacement MCCB, 415 volts, four pole of cap 200 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Metreinals / thimble of suitable size and making connections complete all as specified and directed. 6 Each
51 51 S&F in replacement MCCB, 415 volts, four pole of cap 250 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Metreinals / thimble of suitable size and making connections complete all as specified and directed. 4 Each
52 52 S&F in replacement MCCB, 415 volts, four pole of cap 400 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Metreinals / thimble of suitable size and making connections complete all as specified and directed. 4 Each
53 53 S&F in repair metal clad sockets 2 pole + earth rating 20 amps 250 volt complete all as specified and directed. 30 Each
54 54 S&F in repair MCB 6 to 32 amp, SP ,240 v, 50 Hz AC ,10KA complete all as specified and directed. 150 Each
55 55 S&F in repair MCB ,SPN 6 to 32 amp ,240 v, 50 Hz AC ,10KA complete all as specified and directed. 30 Each
56 56 S&F in replacement MCB DP,40 amp, 240 v, 50 Hz AC ,10 KA complete all as specified and directed. 50 Each
57 57 S&F in replacement MCB DP ,63 amp, 240 v, 50 Hz AC ,10 KA complete all as specified and directed. 50 Each
58 58 S&F in replacement MCB TPN 63 Amps, 240 v, 50 Hz AC ,10 KA terminal box suitable upto 35 sqmm cable complete conforming to IS 8828 of 1996, IEC 60898 of 2002 complete all as specified and directed. 50 Each
59 59 Checking and attending complaints with one electritian and one helper in JCOs and ORs Married Accn in Bihaind buchary area by means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and directed. Note : 1 The electrician deployed by the contractor shall have ITI /03 years expreince certificate in concerned trade.Helper deployed shall be min 8th pass with min 03 years expriance in relevant trade.2. This item covers only cost of labour for attending complaint and taking down of old material. 3. Item to be replaced under this item shall be either isued free for fixing under schedule 'B'or shall be contractor supply under respective items of this schedule as decided by Enge-in -charge.Decided of GE in this regard shale be found and bonding.4. Complaints noted'' NO Light'' shall be attended imediately up to 2200 hrs without fail,failing which recovery of Rs.240/ per complaint shall be effected from the RARs/ F Bill.5. Minor items as PVC wire of any size as per requirement up to 1.0m length,thimble,electric tape etc shall deemed to be included in the quoted rate of this items.6.The complaints shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be leived/imposed on the contractor and recovery shall be made from his dues.7. Contracror shall arrange suitable T&P incl necessary from work and scoffolding and safety measures to make it functional complete all as specified and directed.8. Contractor or his rep will report daily at complaint cell for collection of complaints fromthe concerned JE's incharge,in case after checking& attending the defects, if it is not possible to rectfy the defects within 08 hrs, the facts shall be brought to the notice of Engeer in charge by the contractor/his rep immediately. If Engr -in -chargr is satisfied with contractor's view, no recovery will be made on this account.9.Labour charges for this item shall not be included under items which includes 'M&L','S&F' in repair',fixing only /Fixing in repair etc in respective item of this Schedule/BOQ. 4500 Each Complaint
60 60 Supply only PVC wire copper conducter unsheathed stranded nominal cross sectional area 1.5 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed. 200 RM
61 61 Supply only PVC wire copper conducter unsheathed stranded nominal cross sectional area 2.5 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed. 200 RM
62 62 Supply only PVC wire copper conducter unsheathed stranded nominal cross sectional area 4.0 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed. 200 RM
63 63 Supply only PVC wire copper conducter unsheathed stranded nominal cross sectional area 6.0 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed. 200 RM
64 64 Supply only PVC wire copper conducter unsheathed stranded nominal cross sectional area 10 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed. 200 RM
65 65 Supply only 9 Watt LED Bulbs, high energy efficiency LED luminaire with lumen output of 800-900 lumens , complete all as specified and directed. 750 Each
66 66 S & F in repar Endura Rugby Neon IP65 Bulkhead light fitting 10 watt LED type with complete all accessories including connecting up with three core twisted flexible cable. complete all as specified and directed. 100 Each
67 67 S & F in repair Mirror light 02 fit Linnet reflectionwithout shdows complete all as specified and directed. 150 Each
68 68 S &F in repair surface and walll mounted (2 fit ) LED betten 10W light extended aluminium houseing provided for effcient heat disipation with polycarbonate diffuser &intigrated with electronic driver 10W with 2fit LED tube Rod complete all as specified and directed. 150 Each
69 69 S & F in repair LED Regal Batten (4ft) for LED tube light complete fitting 1x22Watt universal batten suitable for use with single LED tube Cat part no. REGALBATTEN8UPTO 1X22WSSBSWH. complete all as specified and directed. 450 Each
70 70 S &F in repair LED Regal Batten (4ft) for LED light complete fitting 2x22Watt batten suitable for use with single LED tube complete all as specified and directed. 450 Each
71 71 S&F in repair LED tube light 20W suited for installation in existing T8 betten, extruded aluminium heat sink provided for efficient heat dissipation & integrated 20W LED 6000K (4 ft) LED Tube Rod complete all as specified and directed.\n 450 Each
72 72 S&F in repair LED PLUTO NEO (High Lumen) FLAT PANEL 2x2 fit 34 Watt LED 6000K Ultra modern compact surface luminaire suitable for armstrong/ grid/ POP ceiling complete with electronic driver & high brightness SMD LEDs fixure of size 595x595mm complete all as specified and directed. \n 200 Each
73 73 S & F in repair 18W LED Surface mounted downlight with white powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete all as specified and directed. 50 Each
74 74 S& F in repair New generation Post Top Lantern ,energy saving environmental frindly, long life aesthetically designed with semetrical light distribution, spum aluminium landscape luminaire with high power LEDs as light source Cat Part No CORALPT 25W LED 757PSYMTOPC complete all as specified and directed. 20 Each
75 75 Supply only Ventilating Fan Maxima DXI 200 mm white DOM 230v AC,50Hz plastic body incuding self cosing louver and making all electric connections complete all as directed.\n 50 Each
76 76 Supply only Switch socket combination 6/16 A 250V AC universal with box in polycarbonate complete all as specified and directed. 300 Each
77 77 Supply only switch piano flush button type 5 amps single pole one way complete all as specified and directed. 300 Each
78 78 Supply only switch piano flush button type 15 amps single pole one way complete all as specified and directed. 300 Each
79 79 Supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. 300 Each
80 80 Supply only socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed. 300 Each
81 81 Supply only ceiling fan regulator 5 step type . complete all as specified and directed. 200 Each
82 82 Supply only Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed. 200 Each
83 83 Supply Only Flexi LED Strip Light warm type 5 Watt /Mtr 5mtr Roll complete all as specified and directed. 30 Each
84 84 Supply only LED Down light Round 5 Watt(Clear Lens) complete all as specified and directed. 50 Each
85 85 Supply only LED Panel light Round 8 Watt white complete all as specified and directed. 50 Each
86 86 supply only LED Down light warm (SMD) 12 Watt complete all as specified and directed. 100 Each
87 87 Supply only Aesthetically desined energy saving LED 10W wall light / Surface fitting white powder coated CRCA housing and PMMA dome diffuser,6000K complete all as specified and directed. 100 Each
88 88 Supply only LED Panel light Round 8 Watt warm 3000K complete all as specified and directed. 100 Each
89 89 Supply only Aesthetically desined energy saving LED 18W wall light / Surface fitting white powder coated CRCA housing and PMMA dome diffuser,6000K complete all as specified and directed. 100 Each
90 90 Supply only Aesthetically desined energy saving LED 22W wall light / Surface fitting white powder coated CRCA housing and PMMA dome diffuser,6000K .complete all as specified and directed. 100 Each
91 91 Supply only 4 way extention Board 4 universal socket outlet+1switch/indicator /cord length 1.5meter complete all as specified and directed. 50 Each
92 92 Supply only twin core flexible, PVC insulated, unsheathed, multistranded copper conductor wire of size 24x0.0076, complete all as directed. complete all as specified and directed. 100 RM
93 93 Supply only lamp holder insulated body and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as directed.complete all as specified and directed. 100 Each
94 94 Supply only PVC casing & capping 20mm size with fitting material for existing disturbed wiring etc at varius locations as directed and making good surfaces ,match existing etc complete all as specified. 100 RM
95 95 Deduct Credit: for demolished/dismantled material of (-) Rs 234710.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule)\n\nNote: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum