Military Engineer Services-MES has published Repair Maint Of Water Supply Network Connected Works At Otm Omq Area At Af Station Gwalior. Submission Date for this Tender is 22-06-2021. Water Supply Project Tenders in AF STATION GWALIOR Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 10-May-2021 | OTHER CORRIGENDUM | Other | 20-05-2021 |
2 | 17-May-2021 | Tender Postponed | Date | 04-06-2021 |
3 | 03-Jun-2021 | Date Corrigendum2 | Date | 15-06-2021 |
4 | 15-Jun-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-06-2021 |
Name of Work : REPAIR/MAINT OF WATER SUPPLY NETWORK & CONNECTED WORKS AT OTM/OMQ AREA AT AF STATION GWALIOR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep in any type of soil including forming sides and bottom surface to required levels/slops/gradients etc. complete all as specified and directed at site.\nNote: The disturbed surfaces of roads/paths/plinth shall be made good to match with the existing surfaces and is deemed to be included in unit rate quoted. | 1 | 360 | Cum |
2 | 2 | Excavation in mud, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep in any type of soil including forming sides and bottom surface to required levels/slops/gradients etc. complete all as specified and directed at site. | 2 | 50 | Cum |
3 | 3 | Returning, filling in, excavated soil including leveling, watering and well ramming in layers of thickness not exceeding 25 cm in each layer complete all as specified and directed. | 3 | 370 | Cum |
4 | 4 | Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing the soil where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 4 | 40 | Cum |
5 | 5 | Disconnecting and taking up or down old existing steel tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including connected fittings/accessories and fixtures like union,valves etc. seggregation serviceable pipes and fittings, keep them safe custody for reuse and unserviceable material be removed from site of work all as directed and specified for the following sizes :- | 5 | ||
6 | 5.1 | 80 mm bore | 6 | 150 | RM |
7 | 5.2 | 50 mm bore | 7 | 190 | RM |
8 | 5.3 | 40 mm bore | 8 | 160 | RM |
9 | 5.4 | 25 mm bore | 9 | 350 | RM |
10 | 5.5 | 20 mm bore Note: Earth work, returning filling, removing shall be measured & paid separately under respective item. | 10 | 370 | RM |
11 | 6 | Laying, testing old serviceable steel water tubing and connections of any description / any grade and in any position obtained in serviceable condition from taking down, in new or old position as in trenches with using new fittings i.e. bends/ Tee/ sockets/ union / reducers/ elbow etc. including cutting / making new threads at the ends of old pipes for the following size all as specified and directed. :- (NOTE:-Serviceble pipe, fittings shall be obtained from srl item no. 5 here-in-before for reuse.) | 11 | ||
12 | 6.1 | 80 mm bore | 12 | 50 | RM |
13 | 6.2 | 50 mm bore | 13 | 70 | RM |
14 | 6.3 | 40 mm bore | 14 | 60 | RM |
15 | 6.4 | 25 mm bore | 15 | 100 | RM |
16 | 6.5 | 20 mm bore | 16 | 120 | RM |
17 | 7 | Supply /Laying / jointing and testing galvanized iron water tubing medium grade including necessary new steel fittings / accessories ISI Marked complete all as specified and directed for the following sizes. [Make: Tata/Jindal/TT swastik] | 17 | ||
18 | 7.1 | 80 mm bore | 18 | 100 | RM |
19 | 7.2 | 50 mm bore | 19 | 120 | RM |
20 | 7.3 | 40 mm bore | 20 | 100 | RM |
21 | 7.4 | 25 mm bore | 21 | 250 | RM |
22 | 7.5 | 20 mm bore | 22 | 250 | RM |
23 | 8 | Taking up / down existing, cast iron pipe lines / water mains of any description / grade and in position including fittings, accessories and fixtures etc existing in between pipe line, by taking out and opening any type of joints (Tyton /Gasket / Lead joints) complete all as specified and directed by the Engineer-in-Charge for following bore of pipes:- | 23 | ||
24 | 8.1 | 300mm bore | 24 | 21 | RM |
25 | 8.2 | 200mm bore | 26 | 16 | RM |
26 | 8.3 | 150mm bore | 27 | 95 | RM |
27 | 8.4 | 100mm bore | 28 | 120 | RM |
28 | 8.5 | 80mm bore Note:- Old CI pipe / fittings retrieved in serviceable condition from taking down shall be reused in the work as approved by the Engineer-in-Charge. | 29 | 120 | RM |
29 | 9 | Laying, testing in trenches, spigot and socketed cast iron pipes of any description / grade and in any position, as obtained from taking up or down, after making necessary addition / alterations and properly cleaning the pipes complete all as specified and directed by Engineer-in-Charge for following bore of pipes:- | 30 | ||
30 | 9.1 | 300mm bore | 31 | 15 | RM |
31 | 9.2 | 200mm bore | 33 | 10 | RM |
32 | 9.3 | 150mm bore | 34 | 45 | RM |
33 | 9.4 | 100mm bore | 35 | 50 | RM |
34 | 9.5 | 80mm bore NOTE:-(i) Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item of Schedule `A'. | 36 | 50 | RM |
35 | 10 | Supplying ,laying, jointing & testing in trenches ductile iron pipes with spigot and socketed ends class k9, conforming to IS 8392-2000 and suitable for push on joints complete all as specified and directed by Engineer-in-Charge for the following size:- Note :-(i) Earth work, Joints and CI specials/fittings of the pipes shall be measured and paid for separately under appropriate item of Schedule `A'\n(ii) Joints of the pipes shall be measured and paid for separately under appropriate item of Schedule `A'. [Make: TATA/Electrosteel casing Ltd./Jindal] \n | 37 | ||
36 | 10.1 | 300mm bore | 38 | 6 | RM |
37 | 10.2 | 200mm bore | 40 | 6 | RM |
38 | 10.3 | 150mm bore | 41 | 50 | RM |
39 | 10.4 | 100mm bore | 42 | 70 | RM |
40 | 10.5 | 80mm bore | 43 | 70 | RM |
41 | 11 | Material and labour for cast iron/ductile iron specials/fittings such as bend, tee, socket, collar Reducer, Tail Pieces etc. suitable for spigot and socketed/ flanged end pipe of up to 150 mm bore complete all as specified and directed. [Make: Upadhay/Kirlosker /Leader/Kalinga] | 44 | 180 | Kgs |
42 | 12 | All as per item no-11 here-in-before but suitable for CI pipe above150mm bore | 45 | 160 | Kgs |
43 | 13 | Taking down existing gun metal gate valves of any description and in any position, complete all as specified and directed the following sizes :- | 46 | ||
44 | 13.1 | 50mm bore | 47 | 10 | Each |
45 | 13.2 | 40mm bore | 48 | 18 | Each |
46 | 13.3 | 25mm bore | 49 | 30 | Each |
47 | 13.4 | 20mm bore | 50 | 28 | Each |
48 | 13.5 | 15mm bore | 51 | 28 | Each |
49 | 14 | Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe complete all as specified and directed for following bore of pipes [Make:-Zoloto/Leader/Kirlosker] | 52 | ||
50 | 14.1 | 50mm bore | 53 | 10 | Each |
51 | 14.2 | 40mm bore | 54 | 18 | Each |
52 | 14.3 | 25mm bore | 55 | 30 | Each |
53 | 14.4 | 20mm bore | 56 | 28 | Each |
54 | 14.5 | 15mm bore | 57 | 28 | Each |
55 | 15 | Taking up or down existing old cast iron sluice valves of any description and in any position, including taking out joints complete all as specified and directed for the following sizes :- | 58 | ||
56 | 15.1 | 300 mm bore | 59 | 2 | Each |
57 | 15.2 | 150 mm bore | 60 | 5 | Each |
58 | 15.3 | 100 mm bore | 61 | 4 | Each |
59 | 15.4 | 80 mm bore | 62 | 6 | Each |
60 | 16 | Supply, installation, fixing, jointing and testing, ISI Marked, of approved quality, cast iron sluice valve of class PN-1.5 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, long body type, jointed and tested complete all as specified and directed for following bores :- | 63 | ||
61 | 16.1 | 300 mm bore | 64 | 2 | Each |
62 | 16.2 | 150 mm bore | 65 | 5 | Each |
63 | 16.3 | 100 mm bore | 66 | 4 | Each |
64 | 16.4 | 80 mm bore [Note:- (i) Joints of the sluice valve shall be measured and paid for separately under appropriate item of Schedule `A' . (ii) Sluice valve shall be of MAke- Zoloto/Leader /Kirlosker/IVC] | 67 | 6 | Each |
65 | 17 | Taking up or down exiting old cast iron non return valves of any description and in any position, complete all as specified and directed for the following sizes:- | 68 | ||
66 | 17.1 | 150 mm bore | 70 | 2 | Each |
67 | 17.2 | 100 mm bore | 71 | 3 | Each |
68 | 17.3 | 80 mm bore | 72 | 5 | Each |
69 | 18 | Supply and fixing, ISI Marked, of approved quality, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed. For following sizes ( Make- BIR/ Sant/Upadhyay) | 73 | ||
70 | 18.1 | 150 mm bore | 75 | 2 | Each |
71 | 18.2 | 100 mm bore | 76 | 3 | Each |
72 | 18.3 | 80 mm bore NOTE :- (i) Joints of the non return valve shall be measured and paid for separately under appropriate items of Schedule ‘A’ | 77 | 5 | Each |
73 | 19 | Burring out run lead joints for the following sizes of CI pipes/fittings etc all as specified and directed:- | 78 | ||
74 | 19.1 | 300mm bore | 79 | 6 | Each |
75 | 19.2 | 200mm bore | 81 | 4 | Each |
76 | 19.3 | 150mm bore | 82 | 50 | Each |
77 | 19.4 | 100mm bore | 83 | 40 | Each |
78 | 19.5 | 80mm bore | 84 | 30 | Each |
79 | 20 | Material and labour for run lead joints including caulking properly for the following sizes of CI pipes/fittings etc all as specified and directed:- | 85 | ||
80 | 20.1 | 300mm bore | 86 | 6 | Each |
81 | 20.2 | 200mm bore | 88 | 4 | Each |
82 | 20.3 | 150mm bore | 89 | 50 | Each |
83 | 20.4 | 100mm bore | 90 | 40 | Each |
84 | 20.5 | 80mm bore | 91 | 30 | Each |
85 | 21 | Dismantling joints in flanged end cast iron pipes and fittings complete all as specified and directed for following sizes:- | 92 | ||
86 | 21.1 | 300 mm bore | 93 | 3 | Each |
87 | 21.2 | 200 mm bore | 95 | 2 | Each |
88 | 21.3 | 150 mm bore | 96 | 10 | Each |
89 | 21.4 | 100 mm bore | 97 | 10 | Each |
90 | 21.5 | 80 mm bore | 98 | 10 | Each |
91 | 22 | Material and labour for rubber gasket joints in flanged end cast iron pipes and fittings complete with and including minimum 3 mm thick rubber/fibre gasket and necessary nuts/bolts/washers all as specified and directed for following sizes:- | 99 | ||
92 | 22.1 | 300 mm bore | 100 | 3 | Each |
93 | 22.2 | 200 mm bore | 102 | 2 | Each |
94 | 22.3 | 150 mm bore | 103 | 10 | Each |
95 | 22.4 | 100 mm bore | 104 | 10 | Each |
96 | 22.5 | 80 mm bore | 105 | 10 | Each |
97 | 23 | Material and labour for fabricating and fixing on pipe line MS clamp of flat iron made to shape alongwith nuts, bolt washers etc suitable for pipe line all as specified and directed by Engineer-in-Charge for stopping leaking of pipe lines of any description and in any position clamps shall be shape and size as approved, tightened with suitable nuts, bolts washers as directed by Engr-in-charge Note:- (i) Weight of clamps including nuts, bolts and washer shall be measured for payment purpose. (ii) Clamp shall be tightened with using suitable rubber washers. (iii) Clamp shall be applied two coats of black bituminous paints over a coat of red oxide primer after preparation of surface. | 106 | 60 | Kg |
98 | 24 | Taking down old PVC pipe of 15mm dia from any position all as specified and directed. | 107 | 100 | RM |
99 | 25 | M&L for unplasticised PVC pipe of 15mm dia of pressure rating 10Kg/cm2 laid in trenches/floors etc including all fitting, clamp complete all as specified. [Make:- Prince/Supreme/Kisan] | 108 | 100 | RM |
100 | 26 | Cutting of the existing CI pipe line for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including dewatering etc complete all as directed for the following bore of pipes:- | 109 | ||
101 | 26.1 | (a) CI Pipe line 300 mm bore | 110 | 2 | Each Job |
102 | 26.2 | (c) CI pipe line 200 mm bore | 112 | 2 | Each Job |
103 | 26.3 | (d) CI Pipe line 150 mm bore | 113 | 10 | Each Job |
104 | 26.4 | (e) CI Pipe line 100 mm bore | 114 | 8 | Each Job |
105 | 26.5 | (f) CI Pipe line 80 mm bore | 115 | 8 | Each Job |
106 | 27 | Dismantling & breaking down the old existing valve pit chamber of any size and any shape and remove material from site of work complete all as directed. | 116 | 16 | Each Job |
107 | 28 | Material and labour for construction of brick masonry valve pit /chamber complete with 3mm thick MS sheet cover with locking arrangement of size 450x 450x 600mm (depth) (internal dimensions) as shown on Drg No CWE/TD/129 sheet No 1/1 dt 18.12.87 with and including necessary excavation & earth work in any type of soil complete all as specified and directed by Engineer-in-Charge. | 117 | 6 | Each Job |
108 | 29 | All as per srl item No 28 here-in-before but of size of valve pit 600mm x 600mm x 600mm (depth) (internal dimensions) | 118 | 5 | Each Job |
109 | 30 | All as per srl item No 28 here-in-before but of size of valve pit 800mm x 800mm x 900mm (depth) (internal dimensions) | 119 | 5 | Each Job |
110 | 31 | M&L for rectifying leakage of CI pipe line including excavation in any type of soil (not exc 1.5m x1.5m x 6.1m) and making arrangement for dewatering, by using electric/diesel pump/manual additional labour, taking out existing joint and making new run lead joints (Old lead shall be used by burning in new joint) complete all as directed for following size of pipe lines:- | 120 | ||
111 | 31.1 | (a) 300 mm bore | 121 | 5 | Each Job |
112 | 31.2 | (c) 200 mm bore | 123 | 5 | Each Job |
113 | 31.3 | (d) 150 mm bore | 124 | 30 | Each Job |
114 | 31.4 | (e) 100 mm bore | 125 | 15 | Each Job |
115 | 31.5 | (f) 80 mm bore | 126 | 15 | Each Job |
116 | 32 | Material and labour for rectifying leakage of GI pipe line including excavation in mud (not exc 0.7m x0.5mx 6.1m ) and making arrangement for dewatering by using electric/diesel pump/manual additional labour, taking out existing fittings and supply and fixing new fittings as required at site , complete all as directed by Engineer - in - charge for following size of pipe lines:-\n | 127 | ||
117 | 32.1 | (a) 80 mm bore | 128 | 35 | Each Job |
118 | 32.2 | (b) 50 mm bore | 129 | 35 | Each Job |
119 | 32.3 | (c) 40 mm bore | 130 | 35 | Each Job |
120 | 32.4 | (d) 25 mm bore | 131 | 35 | Each Job |
121 | 32.5 | (e) 20 mm bore | 132 | 35 | Each Job |
122 | 32.6 | (f) 15 mm bore | 133 | 10 | Each Job |
123 | 33 | Disconnecting , Dismantling and taking down complete valve from pipe line and refixing the same to its position after following repair of size 300 mm dia complete all as directed. (a) Fabrication and fixing of stainless steel spindle as per sample including threading and machinery work. (b) Fabrication and fixing of GM Nut (Gutka) (c) Fabrication and fixing of gland plate. (d) Replacement of damaged nut, bolt, washers and packing. | 134 | 5 | Each Job |
124 | 34 | All as per srl item No 33 here-in-before but of Size 200mm dia | 135 | 4 | Each Job |
125 | 35 | All as per srl item No 33 here-in-before but of Size 150mm dia | 136 | 8 | Each Job |
126 | 36 | All as per srl item No 33 here-in-before but of Size 100mm dia | 137 | 2 | Each Job |
127 | 37 | All as per srl item No 33 here-in-before but of Size 80mm dia | 138 | 5 | Each Job |
128 | 38 | Dismantling and taking out existing damaged / rusted valve pit cover of any size from valve pit chamber, not less than 1 M x 1 M and M & L for new valve pit coverof size not less than 1 M x 1 M made out from MS Angle iron of size 50 x 50 x 5mm frame with fixing the MS sheet of thickness 3 mm welded on MS angle complete including locking arrangement with applying two coat of synthetic enamel paint 1st grade over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. | 10 | Each Job | |
129 | 39 | Cleaning of wild shrubs,vegetation,bushes etc in soil not exceeding 15CM in depth including removing & cleaning rubbish material from the site upto a distance exc 250m but not exc 500m twice in the contract period complete with the entire satisfaction of Engineer-in-charge. | 139 | 8000 | Sqm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail