Day To Day E/M Maint And Repair/Maint Of Heating Cooling Appliances At Af Stn Mandore Under Age E/M , Ge ( Af ) No 2 Jodhpur, GE (AF) No.2 Jodhpur-Rajasthan

Military Engineer Services-MES has published Day To Day E/M Maint And Repair/Maint Of Heating Cooling Appliances At Af Stn Mandore Under Age E/M , Ge ( Af ) No 2 Jodhpur. Submission Date for this Tender is 11-05-2021. Electromechanical Work Tenders in GE (AF) No.2 Jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

27673606
Corrigendum : Day To Day E/M Maint And Repair/Maint Of Heating Cooling Appliances At Af Stn Mandore Under Age E/M , Ge ( Af ) No 2 Jodhpur
Open Tender
Indian
Rajasthan
GE (AF) No.2 Jodhpur
11-05-2021

Tender Details

Day To Day E / M Maint And Repair / Maint Of Heating Cooling Appliances At Af Stn Mandore Under Age E / M , Ge ( Af ) No 2 Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 34000.0 /-
Tender Value
INR 17 Lakhs /-

BOQ Items

Name of Work : DAY TO DAY E/M MAINT AND REPAIR/MAINT OF HEATING COOLING APPLIANCES AT AF STN MANDORE UNDER AGE E/M, GE (AF) NO 2 JODHPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down copper/aluminium point wiring for (light, fan, bell, socket power socket etc )complete including fixture and fittings such as switches, sockets lamp holder bracket light fittings tube light fittings, regulators, ceiling rose , mirror light fitting , ceiling light fitting, fancy light fitting , fall ceiling light fitting bell/ buzzer and removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per condition separately) and making good disturbed surfaces of wall floor etc. 115 Per point
2 2 Taking down old U/S distribution boards complete and removing materials to store for keeping in safe custody or for taking credit . 12 Each
3 3 M&L Point wiring complete with 1.5 Sqmm single core multi standard copper conductor PVC FLRS insulated unsheathed cable in and incl pvc conduit with accessories existing pressed steel terminal boxes (sunk in wall) including new 3.00 mm thick plastic laminated sheet top cover with 1.50 Sqmm insulated unsheathed PVC covered copper conductor for common earth and connecting to earth dolly for :-
4 3.01 One light point controlled by one one way switch 25 Per point
5 3.02 One fan point controlled by one one way switch 5 Per point
6 3.03 One bell point controlled by one bell push switch 3 Per point
7 3.04 One socket out let 5 Amps on the same board 10 Per point
8 3.05 One socket out 3 pin 5 Amps on the independent board. 10 Per point
9 4 All as per item No 3 above but with 2.5 Sq mm single core multi standard copper conductor cable for 6 pin 15 Amps socket out let on independent board. 10 Per Point
10 5 M&L Point wiring complete with 1.5 Sqmm single core multi standard copper conductor PVC FLRS insulated unsheathed cable in and incl PVC casing capping with accessories existing pressed steel terminal boxes (sunk in wall) including new 3.00 mm thick plastic laminated sheet top cover with 1.50 Sqmm insulated unsheathed PVC covered copper conductor for common earth and connecting to earth dolly for :-
11 5.01 One light point controlled by one one way switch 15 Per point
12 5.02 One fan point controlled by one one way switch 5 Per point
13 5.03 One bell point controlled by one bell push switch 2 Per point
14 5.04 One socket out let 5 Amps on the same board 10 Per point
15 5.05 One socket out 3 pin 5 Amps on the independent board. 10 Per point
16 6 All as per item No 3 above but with 2.5 Sq mm single core multi standard copper conductor cable for 6 pin 15 Amps socket out let on independent board. 10 Per Point
17 7 S&F switch flush type 5 Amp, 240 V single pole one way ISI Marked. 100 Each
18 8 S&F switch socket combination 2 in 1,5 Amps flush type 100 Each
19 9 S&F switch socket combination 3 pin 16 Amps flush type 50 Each
20 10 S&F ceiling rose, 3 Terminal Point/PVC/polycarbonate, isolated body. 70 Each
21 11 S&F lamp holder , PVC /Polycarbonate type with back plate suitable for batten fitting complete with necessary wire connection etc. 40 Each
22 12 M&L for sheet metal enclosures distribution board where MCB to be used with 200 Amps rated bus bar CL-IP-43 240 V, 8 way single pole & neutral link 6 Each
23 13 All as per itme No 12 above but 12 way 240 V, Make :Standerd or eqlt 2 Each
24 14 All as per item No 12 above but 4 way 240 V, 4 Each
25 15 Taking down old u/s MCB's complete of any size& make 88 Each
26 16 M&L in replacement for MCB single pole 6 Amps, 240 V . 40 Each
27 17 M&L in replacement for MCB single pole 10 Amps, 240 V . 20 Each
28 18 M&L in replacement for MCB single pole 16 Amps, 240 V . 10 Each
29 19 M&L in replacement for MCB single pole and neutral 32 Amps, 240 V. 5 Each
30 20 M&L in replacement for MCB single pole & neutral 40 Amps, 240 V . 5 Each
31 21 M&L in replacement for MCB triple pole & neutral 63 Amps, 415 V 8 Each
32 22 Taking down of old u/s LED fitting complete of any type 456 Each
33 23 S&F in repair LED batten (1.2 m) made of CRCA sheet housing with a PC glossy diffuser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make - Crompton Cat No LCTLN-20-WW or equivalent in Philips/Wipro. 398 Each
34 24 S&F in repair LED Recessed full it luminaire with glare free uniform illumination with longer life and less maintance wattages in 2 ft x 2 ft not less then 100 lumen /watt complete all as specified and as directed. temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make - Crompton Cat No LCTLRNE -36-FO-CDL or equivalent in Philips/Wipro/Bajaj 40 Each
35 25 S&F in repair LED Stud Bulk Head 10 watt fixture perfect interior and exterier application within car parks, walkway, stairwells, carridoors, local authorities and housing accosiation as well as commercial building including connection all as per cat ref no. LBHP-10-CDL complete all as specified and directed by Engineer in Charge. Make -Philips or equivalent CG/ Havells 4 Each
36 26 S&F in repair Building Security LED 45 Watt fixture made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection ,commercial building including connection all as per cat ref crompton no. LSTS-45-CDL-M complete all as specified and directed by Engineer in Charge. Make - CG/ Havells . 10 Each
37 27 taking out od old u/s elect door bell of any type & make 6 Each
38 28 S/F elect bell AC 230 V single pole ISI Marked. 3 Each
39 29 S/F elect bell ding dong AC 230 V single pole ISI Marked. 3 Each
40 30 Taking down existing sub main wiring in casing capping/conduit pipe of any size complete. 100 RM
41 31 S&F sub main wiring with 2 run of 6 Sq mm single core copper conductor cable drawn through in rigid PVC conduit ISI marked with fitting and 4.0 Sq mm single core copper conductor cable for continues earth wire all as directed. 100 RM
42 32 Taking out existing earthing complete at site. 4 Each
43 33 M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm 6.0mm thick, buried directly in ground (earth pith not less than 2.25 mtr deep below ground level) with top edge of plated not less than 1.5 mtr below normal ground level connected toincl galvanized iron or steel earth lead wire 4.0mm dia by mean of bolts nuts check nuts & washers of galvanized iron or steel pipe 15mm dia medium grade and connected to main switch board watering pipe shall be 20mm dia GI medium grade incl excavation earth work in any type of soil pit RCC cover complete. 4 Each Set
44 34 taking down old u/s mirror light fitting complete 4 Each
45 35 S&F mirror light fitting LED of 10 Watt 2 feet long complete 230V, 6000k rated CCT energy efficient with automatic ballast pen holders stsrters blocks ,diffusers complete with all accessories including tube internally prewired and including connecting with twin core twisted flexible copper cable complete all as specified and as directed.Make -orient model no-LBLN-10-C /bajaj/crompton 4 Each
46 36 Taking down old /ruptured fan regulator complete 30 Each
47 37 Supply and fixing fan electronic regulator 300w step type all as specified and as directed by Engr-in-Charge. 30 Each
48 38 Taking down old /ruptured casing/capping complete 50 RM
49 39 S&F PVC Casing/capping for electric wire installation complete all as specified and directed 50 RM
50 40 M&L for taking down ceiling fan and refixing the same after repair including striping, cutting the existing copper winding of ceiling fans, rewinding with new heavy duty super enameled copper wire of appropriate gauge (Make-Devi Dayal/ SWAN /CHETAK/MUKATI/USHA with insulation material, varnishing, oiling, greasing, painting in white/grey colour with synthetic enamel paint, replacement of unserviceable other parts like clamps, nut, bolt, washer and locking arrangement, rubber reel, flexible wire, canopy, shaft, capacitor etc. testing complete all as specified and directed by Engineer-in Charge of the following sizes of ceiling fans of make - Usha, Orient, Bajaj, Crompton, Cool Home, Kessles etc.Note:- Replacement of unserviceable other parts like clamps, nut, bolt, washer and locking arrangement, rubber reel, flexible wire, canopy, shaft, capacitor etc. shall be measured & paid for separately as “supply only”.
51 40.01 1200 mm (48") sweep. 15 EACH
52 40.02 1400 mm (56") sweep. 15 EACH
53 41 All as per item No. 40 above but exhaust fans of following sizes:-
54 41.01 230 mm (9") sweep 4 Each
55 41.02 300mm (12") sweep 4 Each
56 41.03 380/400mm (12") sweep 2 Each
57 42 Supply only Gun metal bush of ceiling fans any type of any sweep including cutting of grooves for fixing of bearing instead of bush any type/any size. 30 Each
58 43 Supply only ball bearing of 1200 mm (48")/1400mm sweep make: NBC/SKF/National suitable for ceiling fan. 30 Each
59 44 Supply only ball bearing of make: NBC/SKF/National any sweep suitable for exhaust fans/pedestal fans of any make & size. 10 Each
60 45 Supply only aluminum blades of 1200/1400 mm celing fans of complete all as specified and directed. 30 Each set of 3 Nos
61 46 Supply only oil type condenser of Usha/Bajaj/Unistar Make, 230 volts AC including necessary soldering of capacity 2.5 MFD. 30 Each
62 47 All as per item No.46 above but capacity 4 MFD for exhaust fans/pedestal fans.Make: Jamco/GEC/Crompton 10 Each
63 48 M&L for disconnecting, taking down and refixing the same after repair the geyser of any cap including striping, cutting the existing copper inner tank after welding, brazing and tightening the hold fast ,nuts, bolts, washer etc complete and including making good to disturbed existing surface with plastering all as dircted by Engr-in-Charge 6 Each
64 49 Supply only heating element of Geysers of 1.5 KW rating required at site including rubber washers. Make – Theeta/ Recold/Bajaj (ISI Marked) 3 Each
65 50 All as per srl item No 49 above but 2 KW ordinary size 3 Each
66 51 Supply only thermostat for the Geyser of 25 ltr capacity ISI marked 3 Each
67 52 All as per srl item No 51. above but 50 ltr 3 Each
68 53 Supply only base assembly complete with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut and bolts, washer all as directed by Engr-in-charge for Geyser of capacity 25 litres. 2 Each
69 54 All as per srl item No 53 above but for cap 50 ltr 2 Each
70 55 Supply only GM non return valve 15mm dia and connecting up complete ISI marked 3 Each
71 56 All as per item No 55 but size 20 mm dia. 3 Each
72 57 Supply only safety valve/high pressure release valve for Geyser of 25 Litres capacity ISI marked 3 Each
73 58 All as per item No 57 above but for cap 50 ltr 3 Each
74 59 Supply only PVC heavy duty hot type connecting pieces nylon braided with brass adopters 600 mm/450 mm long and fixing in position suitable for Geyser of 25/50 Litre capacity 6 Each
75 60 Supply only copper connection heavy duty hot type connecting with 02 Nos brass adopters and washer of size 600 mm/450 mm long and fixing in position suitable for geyser of 25/50 litre capacity 6 Each
76 61 Supply only pvc sheathe copper conductor multistranded cable ISI Marked 03 core PVC insulated of size 2.5 sqmm 10 RM
77 62 Supply only plug top 3 pin 15 Amps ISI marked. 5 Each
78 63 Supply only geyser indicator lamp square type/round type 6 Each
79 64 S&F in repair LED flameproof batten complete with twin T8 tube of 20 W complete all as specified and as directed . Make - Crompton Cat No EXTN2LT8-16/20 or equivalent in Philips/Wipro. 4 Each
80 65 Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (rotary type) of 1.5 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge \nMake :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI\n 2 Each job
81 66 Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (reciprocating type) of 1.5 capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge \nMake :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI\n 2 Each job
82 67 Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor ( rotary type) of 2 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge \nMake :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI\n 2 Each job
83 68 Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor ( reciprocating type) of 2 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge \nMake :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI\n 2 Each job
84 69 M&L for servicing of window type/split type AC of 1.5/2.0 tone capacity by taking out the same from existing location, cleaning of condenser, cooling coil, and other components with cooling coil rinse solution and clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note-Spare parts shall be measured and paid sapertaly. 50 Each job
85 70 S&F in replacement of air filter complete suitable for window type/split type AC capacity 1.5 TR/2 TR all as specified and directed by Engr-in-charge 5 Each Nos
86 71 S&F in replacement of starting relay assembly including clips and terminal cover suitable for window type/split type 1.5 TR/2 TR capacity AC complete all as specified and directed by Engr-in-charge. 10 Each Nos
87 72 S&F in replacement of starting capacitor 80/100/120 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge \nMake : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE 10 Each Nos
88 73 S&F in replacement of running capacitor 45/50 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge.\nMake : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE 25 Each Nos
89 74 S&F in replacement of thermostat switch including knob plate and screws etc complete all as specified and directed by Engr-in-charge \nMAKE-RANUTRAL/INDOFOSS/HONEYWELL. 5 Each Nos
90 75 S&F in repairs blower DC fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase for indoor unit complete all as specifed and directed. 2 Each Nos
91 76 S&F in repairs blower fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase for indoor unit complete all as specifed and directed. 6 Each Nos
92 77 S&F in replacement of wiring kit comprising of copper conductor cables for connections of assembly suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge 12 Each Job
93 78 M&L for finding out the leakage with the pressure test of the condenser or cooling coil of window type/split type AC of 1.5/2.0 ton and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge. 30 Each Job
94 79 S&F in replacement condenser for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge. 2 Each job
95 80 S&F in replacement cooling coil for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge. 2 Each job
96 81 S&F in repairs condensing fan motor 1/5 HP single phase, 230 volts, 50 cycle per second suitable for Carrier window type AC complete all as specifed and directed. Make- as per existing site. 2 Each job
97 82 Dismantling and taking out of fan motor and refixing after rewinding with supper enamelled copper winding wire as per existing pattern including insulation, repair of shaft, including replacement of bushes, nuts, bolts, testing and commissioning suitable forwindow type/split type 1.5 TR /2 TR AC complete all as specified and directed by Engr-in-charge \nMake of wire : Devidayal/Chetak 12 Each Job
98 83 M&L for replacement of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed. 5 Each Job
99 84 Reparing of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed. 10 Each Job
100 85 M&L for fan blade of suitable size for 1.5/2 TR capacity of window/Split type AC complete all as specifed and directed. 15 Each Job
101 86 S&F in repair copper tube of size ?” dia for any capacity of split type AC all as specified. 30 RM
102 87 M&L for insulating foam pipe of size ?", ¼", and ?" dia of split type AC any capacity for both indoor and outdoor unit all as specified. 20 RM
103 88 S&F single pole contactor suitable for split type AC capacity 1.5/2.0 Ton all as per specified and directed. Make as per existing site. 8 Each Job
104 89 S&F in repair of flair nut size 5/8" and 1/2"dia for any capacity of split type AC all as specified. 15 Each Job
105 90 S&F in repair of dead nut size 1/4 '' dia for any capacity of split type AC all as specified. 10 Each Job
106 91 M&Lfor repairs of caplliary tube of split /window type AC capacity 1.5/2.0 Ton and all as per specified and directed. Make as per existing site. 8 Each Job
107 92 M&L for servicing of Casstette type AC of 2.0 tone capacity by taking out the same from existing location, cleaning of condenser, cooling coil, and other components with cooling coil rinse solution and clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note-Spare parts shall be measured and paid sapertaly. 1 Each job
108 93 Supply and filling refrigerant gas R-22 for charging in AC complete all as specified and directed by Engr-in-charge.\nMake :- FREON / MEFRON\n 5 Kgs
109 94 Supply and filling refrigerant gas R-134a for charging water coolers/refrigerators complete all as specified and directed by Engr-in-charge. \nMake :- FREON / MEFRON 4 Kgs
110 95 Supply and fixing in replacement of outdoor unit capacity 2 ton with fan motor ,fan blade and suction and discharge L key valve and capillary for 2 TR AC of existing make and model complete all as specified and directed by Engr-in-charge. \n 1 Each job
111 96 Opening up and disconnecting the defective unserviceable sealed compressor unit of water cooler storage type 60/120 ltr/hrs and supply and fixing new compressor existing make and model and including gas charging R22/R 134A and testing complete all as specified and directed by Engr-in-charge \nMake :TECUMSEH /KIRLOSKAR /WHIRLPOOL/COPELAND /VOLTAS\n\n 1 Each Job
112 97 Opening up and disconnecting the defective unserviceable sealed compressor unit of water cooler storage type 150 ltr/hrs and supply and fixing new compressor existing make and model and including gas charging R22/R 134A and testing complete all as specified and directed by Engr-in-charge \nMake :-TECUMSEH /KIRLOSKAR /WHIRLPOOL/COPELAND /VOLTAS\n 2 Each Job
113 98 M&L for servicing of water cooler any capacity by taking out the same from existing location, cleaning of condenser, cooling tank, and other components with cooling tank rinse solution and clean water, greasing of fan, motor, etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note -Spare parts shall be measured and paid separtely. 8 Each job
114 99 S&F in replacement of starting relay open type suitable for compressor of water cooler with clips, relay cover and screws complete all as specified and directed by Engr-in-charge. \n 3 Each Nos
115 100 S&F in replacement of thermostat switch including knob, plate, screws and necessary wiring of water cooler complete all as specified. 3 Each Nos
116 101 S&F in replacement of starting capacitor 40/60 /80/100MFD of water cooler complete all as specified and directed by Engr-in-charge. \n 3 Each Nos
117 102 S&F in replacement of running capacitor 36/45 MFD of water cooler complete all as specified and directed by Engr-in-charge 5 Each Nos
118 103 Taking down and dismantling condencing fan motor of water cooler and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement of gun metal bushes, shaft, clamps including testing and commissioning complete all as specified and directed by Engr-in-charge. \nMake of wire : Devidayal / Chetak 2 Each Job
119 104 M&L for repair to bottom rusted and deteriorated portion of body of 150/150 litres storage/cooling capacity of water cooler up to 300mm in height from bottom including replacement with 20 gauge mild steel sheet with necessary cutting, denting, welding including spray painting with one coat of approved synthetic enamel paint (Ist quality) over a coat of red oxide primer to the entire outer surface of the body after scraping, rubbing, and removing the existing old paint all as specified and directed. 3 Each Job
120 105 S&F in replacement of fan blade of condensing motor for 120/150 ltr /hrs capacity water cooler etc complete all as specified and directed by Engr-in-charge. 5 Each
121 106 S&F in replacement of 15 mm bore push type water tap brass chromium plated of water cooler complete all as specified and directed by Engr-in-charge. \nMake :- As per existing site 5 Each
122 107 S&F in replacement of PVC flexible hose pipe, 32mm dia as in connections fixed at one end of waste water trap with clamp and other end left free to open at appropriate distance of water cooler complete all as specified and directed by Engr-in-charge. 10 Running metre
123 108 S&F in replacement of condensing fan motor of capacity (1/5HP) including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete of water cooler all as specified and directed by Engr-in-charge. \n 1 Each
124 109 S&F in replacement of condenser made out of copper tubes of heavy grade of adequate size of capacity 120/150 ltr /hrs of water cooler including necessary screws, brazing to existing gas pipes & testing complete all as specified and directed by Engr-in-charge. 2 Each
125 110 M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge. 2 Each
126 111 M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 60/120 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge. 1 Each
127 112 Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 180-220 ltr and supply and fixing new compressor of existing make and model and including gas charging 134A complete all as specified and directed by Engr-in-charge. 1 Each Job
128 113 Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 235- 320 ltr and supply and fixing new compressor obtained from the factory outlet/ authorised dealer under their replacement scheme including gas charging 134 A complete all as specified and directed by Engr-in-charge. \n\n 2 Each
129 114 M&L for servicing of refrigerator any capacity by taking out the same from existing location, cleaning of condenser, freezer, and other components with freezer rinse solution and clean water, greasing of fan, motor, etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge. 8 Each
130 115 S&F in replacement of relay assembly suitable for 180-320 litre capacity refrigerator including relay cover, clips and screws complete all as specified and directed by Engr-in-charge.\nMake- As per existing site 4 Each
131 116 S&F in replacement of thermostat switch suitable for refrigerator capacity 180-320 litre including knob, plate and screws complete all as specified and directed by Engr-in-charge.\nMake- As per existing site 4 Each
132 117 S&F in replacement of condenser suitable for 180-320 ltr capacity refrigerator made out of mild steel powder coated tubes of heavy grade of adequate size including necessary mild steel clamps and mild steel CP screws, brazing and connecting to existing gas system complete all as specified and directed by Engr-in-charge. 4 Each
133 118 S&F in replacement of Timer switch of refrigeartor of capcity 180-320 ltrs complete all as specified and directed. 4 Each
134 119 S&F in replacement of evaporator / freezer cabinet complete with freezer door made out of aluminum tubes of adequate size for refrigerator of capacity 180-220 ltr including making connection with old system complete all as specified and directed by Engr-in-charge. 2 Each
135 120 All as per srl item No 119 here-in-before but refrigerator of capacity 235-320 litre. 2 Each
136 121 S&F in replacement of compact fan motor for indoor double door refrigerator 235 -320 ltrs complete all as specified and directed by Engr-in-charge. 2 Each
137 122 S&F in replacement of fan motor condensing unit double door refrigerator 180 -320 ltrs complete all as specified and directed by Engr-in-charge. 2 Each
138 123 M & L of repairing of PCB plate of invertor type refrigeartor of capcity 180-320 ltrs complete all as specified and directed. 2 Each
139 124 Dismantling and taking out of burnt fan motor of desert coolers for upto 4000 CFM and material and labour for rewinding with supper enamelled copper winding wire of existing pattern, repair of shaft including replacement of insulation material, bushes, nuts, bolts, testing and commissioning etc complete all as specified and directed by Engr-in-charge.\nMake of wire : Devidayal / Chetak 18 Each Job
140 125 S&F in replacement of fan motor of desert cooler suitable for upto 4000 CFM single phase, 230 volts, 3 speed with capacitor and bracket including connection to switch and testing complete all as specified and directed by Engr-in-charge. \nMake- KHAITAN/ POLAR /CROMPTON 10 Each
141 126 S&F in replacement of submersible type water pump of desert cooler AC single phase 230 volt including necessary wiring connection and testing complete all as specified and directed by Engr-in-charge.\nMake- KHAITAN/ POLAR /CROMPTON 30 Each
142 127 S&F in replacement of selector switch 3 speed 15 Amps for desert cooler complete all as specified and directed by Engr-in-charge.\nMake - HAVELL'S / CONA / CROMPTON 20 Each
143 128 S&F in replacement of shutters of desert cooler of existing size made out of GI sheet handles duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. 20 Set of Three
144 129 S&F in replacement of body parts of desert cooler bottom tank as per sample made out of 1.25 mm thick complete all as specified and directed by Engr-in-charge. 10 Each Job
145 130 S&F in replacement of capacitor of capacity 4 MFD for motor of desert cooler complete all as specified and directed by Engr-in-charge.\nMake : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE 40 Each Nos
146 131 S&F in replacement of switch piano flush type 5 Amp one way for water pump of desert cooler complete all as specified and directed by Engr-in-charge.\nMake :- LEADER / HAVELLS / LEGRAND 25 Each Nos
147 132 S&F in replacement of front grill of desert cooler as per sample made out of 1.25 mm thick GI sheet of size 520mmx550mm (approximate) complete with air control fins, mild steel CP screws, duly spray painted with synthetic enamel paint complete all as specified and directed by Engr-in-charge. 20 Each Nos
148 133 S&F in replacement of fan blade of fan motor of desert cooler as per sample made out of mild steel duly spray painted with synthetic enamel paint and fixed with mild steel CP screws complete all as specified and directed by Engr-in-charge. 25 Set of three blades
149 134 S&F in replacement of PVC sheathed cable 3 core copper conductor of size 70/.0076mm, flexible for making connection of window type AC complete all as specified and directed by Engr-in-charge.\nMake :- Havells / RR Cable / NICCO / L & T / Finolex 60 Running metre
150 135 S&F in replacement of plug top 3 pin 5 Amps heavy duty for refrigerator /desert cooler complete all as specified and directed by Engr-in-charge.\nMake :- LEADER / HAVELLS / LEGRAND /ANCHOR/BAJAJ 20 Each Nos
151 136 S&F in replacement of plug top 3 pin 15 amps heavy duty for water cooler, Voltage Stablizer & Air Conditioner complete all as specified and directed by Engr-in-charge.\nMake :- LEADER / HAVELLS / LEGRAND /ANCHOR/BAJAJ 5 Each
152 137 M&L for scraping and removing of old paint of desert cooler body (steel surface) and preparation of steel surfaces including necessary denting/welding/cutting etc and spray painting two coats with smoke grey synthetic enamel paint (Ist quality) over a coat of red oxide primer on outer surface and inner surface i.e. water tank and body, fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of red oxide primer complete for desert cooler of any size and capacity complete all as specified and directed. 40 Each Job
153 138 S&F wood wool pad set suitable for desert cooler for existing size complete all as specified and directed by Engr-in-charge. 40 Set of Three Pads
154 139 S&F in replacement of transformer unit of voltage stabilizer 5 KVA copper wound of existing specification including material and labour for replacement of all fittings, circuit plate, screws, terminal block, insulation materials, for input voltage 160 to 250 volt and output voltage 220 to 240 volts capacity complete all as specified and directed by Engr-in-charge.\nMake:- VINITEC / SINETRAC / BLUE BIRD 10 Each
155 140 All as per item No 139 here-in-before but voltage stabilizer of capacity 4 KVA 2 Each
156 141 All as per item No 139 here-in-before but voltage stabilizer of capacity 1 KVA 2 Each
157 142 S&F in replacement of cut off relay for low and high voltage 18/24 volts for voltage stabilizer of capacity 4 KVA to 5 KVA complete all as specified and directed by Engr-in-charge.\nMake:- VINITEC / SINETRAC / BLUE BIRD 8 Each
158 143 S&F in replacement of Volt meter capacity 0 to 300 Volts AC single phase for voltage stabilizer 5 KVA complete all as specified and directed by Engr-in-charge.\nMake : HAVELLS / AE / L&T (RISHAB) / IMP / MECO 8 Each
159 144 M & L for repairing of PCB card for voltage stabilizer of capacity 4 KVA to 5 KVA complete all as specified and directed by Engr-in-charge.\nMake:- VINITEC / SINETRAC / BLUE BIRD 10 Each Job
160 145 Opening and Disconnecting the defective unserviceable sealed compressor unit of deep freezer of any make and type, AC 230 volts single phase of capacity 320 Ltrs and supply and fixing new compressor including recharging refrigerant R -22/ R32/R410 complete all as specified and directed by Engr-in-charge.\nMake : Volts / Kirloskar / Tecumesh 1 Each Job
161 146 S&F in replacement of relay assembly suitable for 320 litre capacity deep freeze including relay cover, clips and screws complete all as specified and directed by Engr-in-charge.\nMAKE: INDFOS / VOLTAS. 1 Each
162 147 S&F in replacement of condensor fan motor for Deep freezer 320 ltrs including installation, commissioning, testing etc complete to entire satisfaction of Engineer-in-Charge. 1 Each
163 148 M&L for shifting of AC any type and capacity, from one location to another location including complete wiring, replacement of copper tubing with provn of complete insulation and leakage if any incl gas charging and testing after installation complete as directed. 2 Each
164 149 Taking down sub main wring/service connection any type/any size including pipe and connecting accessories complete all as per specified and directed. 50 RM
165 150 M&L for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. \nNOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.\n 50 RM
166 151 S&F in replacement of desert cooler body of size approx 660 x 660 x 900 mm with and including front grill and three side louver fabricated out of 22 gauge mild steel plain GI sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge mild steel plain GI sheet including taking out and reinstallation complete with standard fittings such as PVC pipe for water, electric controls and switch, fan speed regulator, rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan, electric pump with new 3 core PVC insulated & PVC sheathed cables (min. 3 metre in length). External surfaces shall be spray painted with two coats of approvedsynthetic enamel paint over a coat of red oxide primer and internal surface of body, cooler pump and motor shall be painted with two coats of bituminous paint over a coat of red oxide primer complete all as specified and directed by the Engineer-in-Charge. 4 Each Nos
167 152 Supply & Fix sheet metal enclosure with a two pin and earth plug socket complete including with 32 Amps MCB Single pole 240 Volt AC incl taking down old one complete all as specified and a directed. 5 Each
168 153 M&L in replacement for MCB single pole & neutral 40 Amps, 240 V incl taking down old one complete all as specified and a directed. 5 Each
169 154 M&L in replacement for MCB triple pole & neutral 63 Amps, 240 V incl taking down old one complete all as specified and a directed. 5 Each
170 155 M&L in replacement for MCB single pole 6 Amps, 240 V incl taking down old one complete all as specified and a directed. 5 Each