Supply And Installation With All Accessories On Turnkey Basis And Its Annual Maintenance For 05 Years Of Capacitor Bank 1 . 98 Mvar ( Qty . 241 Nos . ) And 3 . 96 Mvar ( Qty . 33 Nos . ) -1 12.65 Kv, 1980 Kvar, 3-Phase, 50 C / S Housed In Outdoor Type Crca Panel, Capacitor Bank Having Two Variable Step Of 792 Kvar & One Variable Steps Of 396 Kvar. Bank Shall Be Complete With Capacitor Units Of 264 / 132 Kvar, Aluminium Busbars, Epoxy Insulators, Ht Hrc Fuse, Surge Suppressor Etc. With Details As Follows- ( 1 ) 11 Kv, Aluminium Wound, Dry Type Series Reactors ( A ) 0.528 Kvar For 792 Kvar Step-6 Nos. ( B ) 0.264 Kvar For 396 Kvar Step-3 Nos. ( 2 ) 11 Kv, 3-Phase Indoor Dry Type Rvt-1 Nos. ( 3 ) 12 Kv 3 Phase Indoor Type Metal Enclosed Vacuum Contactor-3 Nos. ( 4 ) Indoor Type Automatic Control Unit-1 No. ( 5 ) Ip 55, Outdoor Crca Cubicle Panel For Accommodating Capacitors, Series Reactors, Vacuum Contactor, Surge Supressor Etc., Alongwith Frp Canopy-1 No. 2 11 Kv, 400 Amp, Off Load Isolator With Earth Switch And Mounting Structure. 3 9 Kv, 10 Ka, Class Iii Lightning Arrestor 4 Control Cables, Lugs / Thimble, Junction Box Etc. 5 11 Kv 3 Core Al. Xlpe Insulated 3X185 Mm Sq. Cable 6 11Kv Xlpe Cable ( 3X185 Sq.Mm. ) Heat Shrinkable Jointing Kit Indoor 7 11Kv Xlpe Cable ( 3X185 Sq.Mm. ) Heat Shrinkable Jointing Kit Outdoor 8 11 Kv Vcb Switchgear For Capacitor Bank With Complete Arangement For Connection With Existing 11 Kv Bus Bar. 9 24 Volt Battery And Battery Charger With Cabinet Complete For Capacitor Vcb 10 Casting Of Civil Foundations 11 Cable Trench For Laying Of Power / Control Cables. 12 Earthing For Panel, Isotator And Las By Chemical Pipe Earthing 13 Gi Strip Of Size-25 X 3 Mm For Connection Of Earthing With Euipment 14 12.65 Kv, 3960 Kvar, 3-Phase, 50 C / S Housed In Outdoor Type Crca Panel, Capacitor Bank Having Two Variable Step Of 792 Kvar & Two Variable Steps Of 1188 Kvar. Bank Shall Be Complete With Capacitor Units Of 396 / 264 Kvar, Aluminium Busbars, Epoxy Insulators, Ht Hrc Fuse, Surge Suppressor Etc.With Details As Follows- ( 1 ) 11 Kv, Aluminium Wound, Dry Type Series Reactors A ) 0.528 Kvar For 792 Kvar Step - 6 Nos. , B ) 0.792 Kvar For 1188 Kvar Step - 6 Nos. ( 2 ) 11 Kv, 3-Phase Dry Type Rvt - 1 No. ( 3 ) 12 Kv 3 Phase Indoor Type Metal Enclosed Vacuum Contactor - 4 Nos. ( 4 ) Indoor Type Automatic Control Unit - 1 No. ( 5 ) Ip 55 , Outdoor Crca Cubicle Panel For Accommodating Capacitors, Series Reactor, Vacuum Contactor, Surge Suppressor Etc., Along With Frp Canopy- 1 Set 15 11 Kv, 400 Amp, Off Load Isolator With Earth Switch And Mounting Structure. 16 9 Kv, 10 Ka, Class Iii Lightning Arrestor 17 Control Cables, Lugs / Thimble, Junction Box Etc. 18 11 Kv 3 Core Al. Xlpe Insulated 3X185 Mm Sq. Cable 19 11Kv Xlpe Cable ( 3X185 Sq.Mm. ) Heat Shrinkable Jointing Kit Indoor 20 11Kv Xlpe Cable ( 3X185 Sq.Mm. ) Heat Shrinkable Jointing Kit Outdoor 21 11 Kv Vcb Switchgear For Capacitor Bank With Complete Arangement For Connection With Existing 11 Kv Bus Bar. 22 24 Volt Battery And Battery Charger With Cabinet Complete For Capacitor Vcb 23 Casting Of Civil Foundations 24 Cable Trench For Laying Of Power / Control Cables. 25 Earthing For Panel, Isotator And Las By Chemical Pipe Earthing 26 Gi Strip Of Size-25 X 3 Mm For Connection Of Earthing With Euipment 27 Annual Maintenance Of 1.98 Mvar Capacitor Bank In All Respect Including Material, Installation, Erection & Fms :– 27.01 1St Year ( Rs. Per Unit ) 27.02 2Nd Year ( Rs. Per Unit ) 27.03 3Rd Year ( Rs. Per Unit ) 27.04 4Th Year ( Rs. Per Unit ) 27.05 5Th Year ( Rs. Per Unit ) 28 Annual Maintemaintenance Of 3.96 Mvar Capacitor Bank In All Respect Including Material, Installation, Erection & Fms :– 28.01 1St Year ( Rs. Per Unit ) . 28.02 2Nd Year ( Rs. Per Unit ) . 28.03 3Rd Year ( Rs. Per Unit ) . 28.04 4Th Year ( Rs. Per Unit ) . 28.05 5Th Year ( Rs. Per Unit ) .