Military Engineer Services-MES has published Repairs To Sewage System At Zone I And Zone Ii Of Age Br Ii Of Ge I Kanpur. Submission Date for this Tender is 08-05-2021. Sewerage Construction Tenders in Kanpur Cantt Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Apr-2021 | REVISED BOQ | BOQ | 01-05-2021 |
2 | 01-May-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-05-2021 |
Name of Work: REPAIRS TO SEWAGE SYSTEM AT ZONE I AND ZONE II OF AGE B/R- II OF GE(I) KANPUR | |||||
---|---|---|---|---|---|
Sl. No. | Description of Items/Works | Item Code / Make | Quantity | Units | |
1 | 1 | B/R SCHEDULE | |||
2 | 2 | M & L for Cleaning/removal of blockage of floor traps/nahani traps of 75 mm/ 100mm bore in kitchan/bathroom/toilets etc up to 1st Manholeincluding of PVC/ Stainless trap greeting and refixing the same with white cement with pigment to match the surface as before or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge. Note - : The Traps shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 2000 | Each | |
3 | 3 | M & L for Cleaning /removal of blockage of Gully traps up to 1st Manhole of any size and any depth including removing RCC covers and refixing the same as before or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge.\nNote - : The Gully Trap shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 1950 | Each | |
4 | 4 | M & L for Cleaning /removal of blockage of Orissa pattern WC 'P'/'S' traps and make functioned up to 1st Manhole or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge..Note - The WC shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 1000 | Each | |
5 | 5 | M & L for Cleaning /removal of blockage of Europian type WC 'P'/'S' traps and make functioned up to 1st Manhole or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge..Note - : The EWC shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 100 | Each | |
6 | 6 | M & L for Cleaning /removal of blockage of Europian type WC 'P'/'S' traps including removing EWC and cleaning the taps completely and make functioned and rifitted the EWC in same position including making good the distrubed surfaces with the help of white cement and pigment to match the existing surface or any other associated /related complaints not mention under this item and will be done as directed by Engr -in-Charge..Note - : The EWC shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 10 | Each | |
7 | 7 | M & L for Cleaning /removal of blockage up to 300 mm bore SWG/RCC pipes including Man Hole of depth not exc 1.50 mtr using Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge.Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge | 2100 | RM | |
8 | 8 | M & L for Cleaning /removal of blockage up to 300 mm bore SWG/Rcc pipesincluding Man Hole of depth exc 1.50 mtr but not exc 3.00 mtr using Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge.Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge | 1500 | RM | |
9 | 9 | M & L for Cleaning /removal of blockage up to 300 mm bore SWG/RCC pipes including Man Hole of depth exc 3 mtr but not exc 4.50 mtrusing Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge.Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge | 600 | RM | |
10 | 10 | M & L for Cleaning /removal of blockage exc 300 mm but n.exc 450 mm bore SWG/RCC pipes including Man Hole of depth exc 4.5 mtr but not exc 6.00 mtr using Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge.Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge | 100 | RM | |
11 | 11 | M & L for Dewatering/desilting of existing manholes of internal size n exc 0.80mx0.80m depth n exc 1.50m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion)and incl removing RCC manhole Covers and refixing the same after cleaning the same position, complete all as directed by Engineer-in-charge. | 800 | Each | |
12 | 12 | M & L for Dewatering/desilting of existing manholes of internal size n exc 1.00mx1.00m depth exc 1.50m but n exc 3.00m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion)and incl removing RCC manhole Covers and refixing the same after cleaning the same position, complete all as directed by Engineer-in-charge. | 450 | Each | |
13 | 13 | M & L for Dewatering/desilting of existing manholes of internal size n exc 1.50mx1.50m depth exc 3.00 m but n.exc 6.00 m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion)and incl removing RCC manhole Covers and refixing the same after cleaning the same position, complete all as directed by Engineer-in-charge. | 25 | Each | |
14 | 14 | M & L for Dewatering/desilting of existing Septic Tank/Soakage Well incl removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as directed by Engineer-in-charge for the following sizes\nNote - : The Septic tank shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 120 | cum | |
15 | 15 | M & L for Taking down cement plaster on brick/stone walls & concrete surfaces & the like including racking out joints, hacking for key, scrubbing down with water etc., any description, complete all as specified. | 1200 | Sqm | |
16 | 16 | M & L for Demolition of RCC work of any description and in any position (reinforcement cut as required to facilitate demolition), complete all as specified. | 8 | Cum | |
17 | 17 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 meter in depth for shitting sewage lines including trimming of sides etc, complete all as specified. | 230 | Cum | |
18 | 18 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and exceeding 1.5m not exceeding 3.00 meter in depth for shitting sewage lines including trimming of sides etc, complete all as specified. | 40 | Cum | |
19 | 19 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and exceeding 3.0 m not exceeding 4.50 meter in depth for shitting sewage lines including trimming of sides etc, complete all as specified. | 30 | Cum | |
20 | 20 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and exceeding 4.50 m not exceeding 8.00meter in depth for shitting sewage lines including trimming of sides etc, complete all as specified. | 25 | Cum | |
21 | 21 | M & L for Demolition and breaking up drain pipes 150mm /200 mm bore (salt glazed ware, AC or reinforced) set in cement mortar incl demolation of PCC haunching etc, complete all as specified. | 500 | RM | |
22 | 22 | M & L for Demolition of brick work in any position, built in cement mortar, complete all as specified. | 25 | Cum | |
23 | 23 | M & L for Plain cement concrete (1:5:10), type E-2, using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. | 7 | Cum | |
24 | 24 | M&L Plain cement concrete (1:3:6), type C -2, using 40mm graded stone aggregate as in bed to drain pipes of 200 mm bore including packing under and hunching against the sides of pipes after they are laid and tested, complete all as specified. | 480 | RM | |
25 | 25 | M&L Plain cement concrete (1:3:6), type C -2, using 40mm graded stone aggregate as in bed to drain pipes of 300 mm bore including packing under and hunching against the sides of pipes after they are laid and tested, complete all as specified. | 120 | RM | |
26 | 26 | S & F Reinforced concrete pipes,200 mm dia class NP2 , laid and jointed complete with collars all as specified and directed by Engr-in-Charge | 500 | RM | |
27 | 27 | S & F Reinforced concrete pipes,300 mm dia class NP2 , laid and jointed complete with collars all as specified and directed by Engr-in-Charge | 130 | RM | |
28 | 28 | M&L Brick work with sub Class ‘B’ bricks straight or curved on plan exceeding 6 mm mean radius built in cement mortar 1:4, complete all as specified. | 25 | Cum | |
29 | 29 | M&L Rendering 15 mm thick mixed with WPC as per manufacturer instruction on fair face of brick work conc surface in CM 1:4 mixed even and smooth without extra cement including necessary scaffolding, complete all as specified.(Note WPC Shall be measured seprately) | 1308.7 | Sqm | |
30 | 30 | Supply only integral water proofing compound, complete all as specified. | 55 | Kg | |
31 | 31 | M&L Plain cement concrete ( 1:2:4), type B-1, (using 20 mm graded stone aggregate) as in surface channels and drains, benching of manholes laid to shape including necessary form works, complete all as specified. | 4 | Cum | |
32 | 32 | M & L for Extra for forming fair finished drain or channels 30 cm inner grith in cement concrete, using extra cement incl form moulds mittred / stopped end etc complete all as specified. | 30 | RM | |
33 | 33 | M & L for Plain cement concrete ( 1:2:4), type B-1, (using 20 mm graded stone aggregate) as in coping bedplates & other similar works, including necessary form works wearthering, slightly rounded angles and theading, complete all as specified. | 4 | Cum | |
34 | 34 | M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100 mm bore pipe, complete all as specified. | 5 | Each | |
35 | 35 | M & L for Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified. | 240 | Cum | |
36 | 36 | M & L for Removal excavated material to distance not exceeding 100 metre and depositing where directed at level not exceeding 1.5 metre above the starting point in soil, complete all as specified. | 85 | Cum | |
37 | 37 | M & L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia all as directed and specified. | 1200 | Kg | |
38 | 38 | M & L for Providing pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded aggregate) as in manhole covers, complete all as specified. | 8 | Cum | |
39 | 39 | M & L for Dismantling of SGSW or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required up to 200 mm internal dia of drains including haunching benching excluding bedding. | 500 | RM | |
40 | 40 | M & L for Dismantling of SGSW or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required up to 300 mm internal dia of drains including haunching benching excluding bedding. | 130 | RM | |
41 | 41 | M & L for Dismantling of cast iron drain pipes, jointed in cement mortar and taking out of trenches,or fixed to wall if required 100mm internal dia of drains. | 575 | RM | |
42 | 42 | M & L for Dismantling of cast iron drain pipes, jointed in cement mortar and taking out of trenches,or fixed to wall if required up to 75mm internal dia of drains. | 450 | RM | |
43 | 43 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) | 78.05 | Cum | |
44 | 44 | S&F in repairs 75 mm dia , PVC (SWR) soil, waste and rain water drainage pipes single socketed in any length with rubber ring joints, laid in trenches or in floor all as specified | 150 | RM | |
45 | 45 | S&F in repairs 110 mm dia , PVC (SWR) soil, waste and rain water drainage pipes single socketed in any length with rubber ring joints, laid in trenches or in floor all as specified | 75 | RM | |
46 | 46 | S&F in repairs 75 mm dia , PVC (SWR) soil, waste and rain water drainage pipes Double socketed in any length with rubber ring joints, fixed to walls with clamps all as specified | 300 | RM | |
47 | 47 | S&F in repairs 110 mm dia , PVC (SWR) soil, waste and rain water drainage pipes Double socketed in any length with rubber ring joints, fixed to walls with clamps all as specified | 500 | RM | |
48 | 48 | S & F 75 mm PVC (SWR) bends any radius | 100 | Each | |
49 | 49 | S & F 110 mm PVC (SWR) bends any radius | 150 | Each | |
50 | 50 | S & F 75 MM PVC (SWR) junction single, (Single T) equal or unequal | 20 | Each | |
51 | 51 | S & F 110 MM PVC (SWR) junction single, (Single T) equal or unequal | 20 | Each | |
52 | 52 | S & F 75 MM PVC (SWR) Branch piece, single (single Y) equal or unequal | 20 | Each | |
53 | 53 | S & F 110mm PVC ( SWR ) vent cowl | 40 | Each | |
54 | 54 | S & F in repair 75 mm PVC (SWR) floor trap ,plain with grating including jointing with solvent cement | 5 | Each | |
55 | 55 | M& L for PVC (SWR) gully trap 125/110 mm , setting and jointing with solvent cement | 15 | Each | |
56 | 56 | Applicable for all items:\nNotes 1 : ( for relevent Items ) :If It is not feasible for access of mechanized system for cleaning of line/ MH/ other associated work, same will be executed as per direction of Engr-in-Charge. Decision of inaccessibility of mechanised system shall be decided by Engr -in- Charge and shall be final.\nNote 2 : All safety precautions will be as per government policies in vogue shall be adhered by contractor.\nNote 3: All T&P, mask,safety equipments and other items required at site under subject contract shall be provided by Contractor.\n |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail