National Security Guard-NSG has published Annual Repair Maintenance Of Residential Buildings Type I Ii Iii Iv V Vi Elect At Nsg Garrison Manesar For The Year 2021 22. Submission Date for this Tender is 17-04-2021. Building Repair Tenders in NSG Manesar Gurugram Haryana Haryana. Bidders can get complete Tender details and download the document.
Name of Work: ARM OF RESIDENTIAL BUILDINGS TYPE-I,II,III,IV,V & VI (ELECT) AT NSG GARRISON MANESAR FOR THE YEAR 2021-22 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | |||
2 | 1.02 | Group A | 480 | Point | |
3 | 1.03 | Group B | 165 | Point | |
4 | 1.04 | Group C | 72 | Point | |
5 | 1.05 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | 18 | Point | |
6 | 1.06 | Rewiring for light point/ fan point/ exhaust fan point/ call bell\npoint with 1.5 sq.mm FRLS PVC insulated copper conductor\nsingle core cable and 1.5 sq.mm FRLS PVC insulated copper\nconductor single core cable as earth wire in existing surface/\nrecessed steel/PVC conduit including dismantling as required. | |||
7 | 1.07 | Group A | 35 | Point | |
8 | 1.08 | Group B | 20 | Point | |
9 | 1.09 | Group C | 18 | Point | |
10 | 2.01 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | |||
11 | 2.02 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 1850 | Mtr | |
12 | 2.03 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 1720 | Mtr | |
13 | 2.04 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 450 | Mtr | |
14 | 2.05 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire | 350 | Mtr | |
15 | 2.06 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 120 | Mtr | |
16 | 2.07 | Supplying and drawing following sizes of FRLS PVC insulated\ncopper conductor, single core cable in the existing surface/\nrecessed steel/ PVC conduit as required. | |||
17 | 2.08 | 1 x 1.5 sq. mm | 100 | Mtr | |
18 | 2.09 | 2 x 1.5 sq. mm | 320 | Mtr | |
19 | 3.01 | 3 x 1.5 sq. mm | 350 | Mtr | |
20 | 3.02 | 3 x 4 sq. mm | 380 | Mtr | |
21 | 3.03 | 3 x 6 sq. mm | 150 | Mtr | |
22 | 3.04 | 5 x 6 sq. mm | 180 | Mtr | |
23 | 3.05 | 6 x 6 sq. mm | 120 | Mtr | |
24 | 3.06 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. | |||
25 | 3.07 | 1 Pair | 25 | Mtr | |
26 | 3.08 | 2 Pair | 20 | Mtr | |
27 | 3.09 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. | 49 | Mtr | |
28 | 4.01 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | |||
29 | 4.02 | 20 mm | 250 | Mtr | |
30 | 4.03 | 25 mm | 250 | Mtr | |
31 | 4.04 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | |||
32 | 4.05 | TV antenna socket outlet | 25 | Each | |
33 | 4.06 | Telephone socket outlet | 25 | Each | |
34 | 4.07 | Bell push | 25 | Each | |
35 | 4.08 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 100 | Each | |
36 | 4.09 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 25 | Each | |
37 | 5.01 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. | |||
38 | 5.02 | 1 or 2 Module (75mmX75mm) | 20 | Each | |
39 | 5.03 | 3 Module (100mmX75mm) | 35 | Each | |
40 | 5.04 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 45 | Each | |
41 | 5.05 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 48 | Each | |
42 | 5.06 | Supplying and fixing following way, horizontal type three pole\nand neutral, sheet steel, MCB distribution board, 415 V, on\nsurface/ recess, complete with tinned copper bus bar, neutral\nbus bar, earth bar, din bar, interconnections, powder painted\nincluding earthing etc. as required. (But without\nMCB/RCCB/Isolator) | |||
43 | 5.07 | 4 way (4 + 12), Double door | 5 | Each | |
44 | 5.08 | 6 way (4 + 18), Double door | 3 | Each | |
45 | 5.09 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. | 30 | Each | |
46 | 6.01 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for\nfollowing triple pole and neutral, sheet steel, MCB distribution\nboard, 415 Volts, on surface/ recess, complete with testing and\ncommissioning etc.as required. | |||
47 | 6.02 | For 4 way, Double door TPN MCBDB | 5 | Each | |
48 | 6.03 | For 6 way, Double door TPN MCBDB | 3 | Each | |
49 | 6.04 | Supplying, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceilling fan with Brush Less Direct Current (BLDC) Motor , class of insulation: B, 3 nos blades, 30 cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value(CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V , 50 Hz, single phase AC Supply , earthing etc complete as required. | 45 | Each | |
50 | 6.05 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | 5 | Set | |
51 | 6.06 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | 38 | Mtr | |
52 | 6.07 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. | 82 | Mtr | |
53 | 6.08 | Supplying and laying of following size DWC HDPE pipe ISI marked\nalong with all accessories like socket, bend, couplers etc.\nconforming to IS 14930, Part II complete with fitting and cutting,\njointing etc.direct in ground (75 cm below ground level) including\nexcavation and refilling the trench but excluding sand cushioning\nand protective covering etc., complete as required. | |||
54 | 6.09 | 63 mm dia (OD-63 mm & ID-51 mm nominal) | 450 | Mtr | |
55 | 7.01 | Supply, Installation, testing and commissioning of 35 Ltr capacity storage Electrical water heater having min 5 star rating model No. 035GV of Venus make or equivalent in Bajaj/Havells make directly on wall with PVC Connection pipe including making connection etc as required. | 18 | Each | |
56 | 7.02 | Supply, Installation, testing and commissioning of 20/21W aluminium extruded LED fitting 4' long , complete with all accessories Model no. BN021C LED20S make Philips or equivalent make of C&S/ Havells directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | 75 | Each | |
57 | 7.03 | Supply, Installation, testing and commissioning of 10W aluminium extruded LED fitting 2' long , complete with all accessories Model no. LTTB4F10WLED/W make C&S or equivalent make of Philips/ Havells directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | 18 | Each | |
58 | 7.04 | Supply, Installation, testing and commissioning of 10 W aluminium housing LED bulkhead fitting Model No. LTB10WLED make C &S or equivalent including connection etc as required. | 10 | Each | |
59 | 7.05 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 x 35 sq mm on wall surface as required. (clamped with 1mm thick saddle) | 520 | Mtr | |
60 | 7.06 | Rewinding of following size of fans (Rate are less of US copper) | |||
61 | 7.07 | 1200 mm Sweep Ceiling/wall/cabin fan | 200 | Job | |
62 | 7.08 | 1400 mm Sweep Ceiling/wall/cabin fan | 80 | Job | |
63 | 7.09 | 300 mm Exhaust Fan | 25 | Job | |
64 | 8.01 | 600 mm Exhaust Fan | 5 | Job | |
65 | 8.02 | Providing and fixing of bearing (Rate are less of US copper) | |||
66 | 8.03 | 1200 mm Sweep Ceiling/wall/cabin fan | 300 | Each | |
67 | 8.04 | 1400 mm Sweep Ceiling/wall/cabin fan | 100 | Each | |
68 | 8.05 | 300 mm Exhaust Fan | 50 | Each | |
69 | 8.06 | 600 mm Exhaust Fan | 10 | Each | |
70 | 8.07 | Turning of MS shaft of ceilling fan lathe work etc complete as required. | 280 | Job | |
71 | 8.08 | Providing and fixing of bearing sheet and welding including cutting finishing work of 1200 mm to 1400 mm ceilling fan. | 145 | Each | |
72 | 8.09 | Providing and fixing of piano type Wifi touch switch 10 A , 240 V in the existing switch board including connection etc as per reqd. | 50 | Each | |
73 | 9.01 | Providing and fixing of two module Wifi touch type fan regulator 10 A , 240 V in the existing switch board including connection etc as per reqd. | 10 | Each | |
74 | 9.02 | Replacement of 2.5 MFD Capacitor in existing fan including dismentalling, assembling, installation, testing ,commissioning directly on ceilling/wall & connectionetc as required. | 280 | Each | |
75 | 9.03 | Replacement of 4.0 MFD Capacitor in existing fan including dismentalling, assembling, installation, testing ,commissioning directly on ceilling/wall & connectionetc as required. | 95 | Each |