Annual Repair Maintenance Of Residential Buildings Type I Ii Iii Iv V Vi Elect At Nsg Garrison Manesar For The Year 2021 22, NSG Manesar Gurugram Haryana-Haryana

National Security Guard-NSG has published Annual Repair Maintenance Of Residential Buildings Type I Ii Iii Iv V Vi Elect At Nsg Garrison Manesar For The Year 2021 22. Submission Date for this Tender is 17-04-2021. Building Repair Tenders in NSG Manesar Gurugram Haryana Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

27636043
Annual Repair Maintenance Of Residential Buildings Type I Ii Iii Iv V Vi Elect At Nsg Garrison Manesar For The Year 2021 22
Open Tender
Indian
Haryana
NSG Manesar Gurugram Haryana
17-04-2021

Tender Details

Annual repair maintenance Of Residential Buildings Type I Ii Iii Iv V Vi Elect At Nsg Garrison Manesar For The Year 2021 22

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: ARM OF RESIDENTIAL BUILDINGS TYPE-I,II,III,IV,V & VI (ELECT) AT NSG GARRISON MANESAR FOR THE YEAR 2021-22
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2 1.02 Group A 480 Point
3 1.03 Group B 165 Point
4 1.04 Group C 72 Point
5 1.05 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 18 Point
6 1.06 Rewiring for light point/ fan point/ exhaust fan point/ call bell\npoint with 1.5 sq.mm FRLS PVC insulated copper conductor\nsingle core cable and 1.5 sq.mm FRLS PVC insulated copper\nconductor single core cable as earth wire in existing surface/\nrecessed steel/PVC conduit including dismantling as required.
7 1.07 Group A 35 Point
8 1.08 Group B 20 Point
9 1.09 Group C 18 Point
10 2.01 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
11 2.02 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1850 Mtr
12 2.03 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1720 Mtr
13 2.04 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 450 Mtr
14 2.05 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 350 Mtr
15 2.06 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 120 Mtr
16 2.07 Supplying and drawing following sizes of FRLS PVC insulated\ncopper conductor, single core cable in the existing surface/\nrecessed steel/ PVC conduit as required.
17 2.08 1 x 1.5 sq. mm 100 Mtr
18 2.09 2 x 1.5 sq. mm 320 Mtr
19 3.01 3 x 1.5 sq. mm 350 Mtr
20 3.02 3 x 4 sq. mm 380 Mtr
21 3.03 3 x 6 sq. mm 150 Mtr
22 3.04 5 x 6 sq. mm 180 Mtr
23 3.05 6 x 6 sq. mm 120 Mtr
24 3.06 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
25 3.07 1 Pair 25 Mtr
26 3.08 2 Pair 20 Mtr
27 3.09 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 49 Mtr
28 4.01 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
29 4.02 20 mm 250 Mtr
30 4.03 25 mm 250 Mtr
31 4.04 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
32 4.05 TV antenna socket outlet 25 Each
33 4.06 Telephone socket outlet 25 Each
34 4.07 Bell push 25 Each
35 4.08 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 100 Each
36 4.09 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 25 Each
37 5.01 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
38 5.02 1 or 2 Module (75mmX75mm) 20 Each
39 5.03 3 Module (100mmX75mm) 35 Each
40 5.04 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 45 Each
41 5.05 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 48 Each
42 5.06 Supplying and fixing following way, horizontal type three pole\nand neutral, sheet steel, MCB distribution board, 415 V, on\nsurface/ recess, complete with tinned copper bus bar, neutral\nbus bar, earth bar, din bar, interconnections, powder painted\nincluding earthing etc. as required. (But without\nMCB/RCCB/Isolator)
43 5.07 4 way (4 + 12), Double door 5 Each
44 5.08 6 way (4 + 18), Double door 3 Each
45 5.09 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 30 Each
46 6.01 Supplying and fixing Cable End Box (Loose Wire Box) suitable for\nfollowing triple pole and neutral, sheet steel, MCB distribution\nboard, 415 Volts, on surface/ recess, complete with testing and\ncommissioning etc.as required.
47 6.02 For 4 way, Double door TPN MCBDB 5 Each
48 6.03 For 6 way, Double door TPN MCBDB 3 Each
49 6.04 Supplying, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceilling fan with Brush Less Direct Current (BLDC) Motor , class of insulation: B, 3 nos blades, 30 cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value(CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V , 50 Hz, single phase AC Supply , earthing etc complete as required. 45 Each
50 6.05 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 5 Set
51 6.06 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 38 Mtr
52 6.07 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. 82 Mtr
53 6.08 Supplying and laying of following size DWC HDPE pipe ISI marked\nalong with all accessories like socket, bend, couplers etc.\nconforming to IS 14930, Part II complete with fitting and cutting,\njointing etc.direct in ground (75 cm below ground level) including\nexcavation and refilling the trench but excluding sand cushioning\nand protective covering etc., complete as required.
54 6.09 63 mm dia (OD-63 mm & ID-51 mm nominal) 450 Mtr
55 7.01 Supply, Installation, testing and commissioning of 35 Ltr capacity storage Electrical water heater having min 5 star rating model No. 035GV of Venus make or equivalent in Bajaj/Havells make directly on wall with PVC Connection pipe including making connection etc as required. 18 Each
56 7.02 Supply, Installation, testing and commissioning of 20/21W aluminium extruded LED fitting 4' long , complete with all accessories Model no. BN021C LED20S make Philips or equivalent make of C&S/ Havells directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 75 Each
57 7.03 Supply, Installation, testing and commissioning of 10W aluminium extruded LED fitting 2' long , complete with all accessories Model no. LTTB4F10WLED/W make C&S or equivalent make of Philips/ Havells directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 18 Each
58 7.04 Supply, Installation, testing and commissioning of 10 W aluminium housing LED bulkhead fitting Model No. LTB10WLED make C &S or equivalent including connection etc as required. 10 Each
59 7.05 Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 x 35 sq mm on wall surface as required. (clamped with 1mm thick saddle) 520 Mtr
60 7.06 Rewinding of following size of fans (Rate are less of US copper)
61 7.07 1200 mm Sweep Ceiling/wall/cabin fan 200 Job
62 7.08 1400 mm Sweep Ceiling/wall/cabin fan 80 Job
63 7.09 300 mm Exhaust Fan 25 Job
64 8.01 600 mm Exhaust Fan 5 Job
65 8.02 Providing and fixing of bearing (Rate are less of US copper)
66 8.03 1200 mm Sweep Ceiling/wall/cabin fan 300 Each
67 8.04 1400 mm Sweep Ceiling/wall/cabin fan 100 Each
68 8.05 300 mm Exhaust Fan 50 Each
69 8.06 600 mm Exhaust Fan 10 Each
70 8.07 Turning of MS shaft of ceilling fan lathe work etc complete as required. 280 Job
71 8.08 Providing and fixing of bearing sheet and welding including cutting finishing work of 1200 mm to 1400 mm ceilling fan. 145 Each
72 8.09 Providing and fixing of piano type Wifi touch switch 10 A , 240 V in the existing switch board including connection etc as per reqd. 50 Each
73 9.01 Providing and fixing of two module Wifi touch type fan regulator 10 A , 240 V in the existing switch board including connection etc as per reqd. 10 Each
74 9.02 Replacement of 2.5 MFD Capacitor in existing fan including dismentalling, assembling, installation, testing ,commissioning directly on ceilling/wall & connectionetc as required. 280 Each
75 9.03 Replacement of 4.0 MFD Capacitor in existing fan including dismentalling, assembling, installation, testing ,commissioning directly on ceilling/wall & connectionetc as required. 95 Each
Disclaimer :