Military Engineer Services-MES has published Repairs/Maint Of Split/Window Type Ac , Water Cooler , Desert Cooler , Deep Freezers And Refrigerator , Ceiling Fan/Exhaust Fan And Misc Items Of E/M Works At Af Ramgarh , Chandan And Jaisalmer Under Ge ( Af ) Jaisalmer. Submission Date for this Tender is 06-05-2021. Air Cooler Tenders in GE (AF) Jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 29-Apr-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-05-2021 |
Name of Work : REPAIRS/MAINT OF SPLIT/WINDOW TYPE AC, WATER COOLER, DESERT COOLER, DEEP FREEZERS AND REFRIGERATOR, CEILING FAN/EXHAUST FAN AND MISC ITEMS OF E/M WORKS AT AF RAMGARH, CHANDAN AND JAISALMER UNDER GE (AF) JAISALMER | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Cleaning down complete body including fitting and fixture of desert cooler of capacity 4000/5000 Cum/hours of any make with wire including removal of all sludges, loose paint dust, dirt etc and prepared the clean surface for painting, and for applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, including rewriting of MES No etc complete all as specified and directed. | 250 | Each Job | |
2 | 2 | Taking out fan motor single phase, 230 Volts, 1400 RPM, 3 Speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and re-fixing in same position ccomplete all as specified and directed | 65 | Each Job | |
3 | 3 | Front grill/louvers to desert cooler made out from 0.80 mm thick Galvanised Iron sheet suitable for 5000/4000 Cum/hours capacity desert cooler of any make fixed in repair complete all as specified and directed | 45 | Each | |
4 | 4 | PVC flexible pipe 16mm outer dia with bends complete with PVC elbow fixed in repair complete all as specified and directed. | 220 | RM | |
5 | 5 | Selector switches three way, 230 volts single phase of standard quality fixed in desert coolers fixed in repair complete all as specified and directed. | 85 | Each | |
6 | 6 | Wood pad, minimum weight 0.80 Kg, fixed in side panels of desert coolers including taking down old unserviceable complete all as specified and directed. | 320 | Set of three | |
7 | 7 | Desert cooler motor of three speed, 1400 RPM, 230 volts, copper winding single phase with ring, side legs, necessary bolts and nuts of capacity 1/6 to 1/8 HP including taking down old unserviceable complete all as specified and directed. | 75 | Each | |
8 | 8 | Plug top, three Pin, 5/6 Amps, 230 volts, ISI Marked including taking down old unserviceable complete all as specified and directed. | 120 | Each | |
9 | 9 | Switch piano type, 240 volts, Singe Pole, one ways, 6 Amps, ISI Marked, fixed in desert coolers including taking down old unserviceable complete all as specified and directed. | 85 | Each set of two | |
10 | 10 | 1.50 sqmm, PVC insulated and sheathed round flexible three core copper conductor cable including necessary connection fixed in desert coolers including taking down old unserviceable complete all as specified and directed. | 450 | RM | |
11 | 11 | Capacitor 4 MFD for fan motor of desert cooler with ISI Marked including taking down old unserviceable complete all as specified and directed.\n\n | 75 | Each | |
12 | 12 | Body of 22 gauge suitable for coolers of capacity 4000/5000 Cum/hour including taking down old unserviceable complete all as specified and directed. | 20 | Each | |
13 | 13 | Side shutter made out from 0.80 mm thick galvanised iron sheet of capacity 4000/5000 cum/hours desert cooler fixed in repair complete all as specified and directed. | 30 | Set of three | |
14 | 14 | Submersible water lifting pump heavy duty of capacity 1/60 HP, 230 Volts 50 Hz Single Phase, including pump support plate fabricated with 0.40mm thick GI sheet with fixing screws, nuts and bolts for desert cooler including taking down old unserviceable water pump complete all as specified and directed. | 185 | Each | |
15 | 15 | Supply, installation and testing desert cooler electric driven single phase having normal air flow capacity 4000/5000 Cum per Hour made out of GI plain sheet of 20 SWG and side panels of 22 SWG, front grill heavy duty having minimum weight 3.0 Kgs made out of GI sheet, wood wool pads (set of three) weight not less than 500 gms superior quality, including suitable motor, water pump, PVC pipe, PVC elbow, PVC distributor three way superior quality for desert including taking down old unserviceable desert cooler complete all as specified and directed. Note : Old unserviceable desert cooler shall be deposit to MES store by the contractor. | 35 | Each Job | |
16 | 16 | Aluminium Fan blade with bush powder coated for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed. | 60 | Each | |
17 | 17 | Cast Iron ring of cooler Fan motor Leg set (RH & LH) with clamps suitable for desert cooler complete with nuts & bolts including taking down old unserviceable complete all as specified and directed. | 45 | Each | |
18 | 18 | PVC, 3 way distributor of water supply suitable for 15mm pipe with nut/screws including taking down old unserviceable complete all as specified and directed. | 75 | Each | |
19 | 19 | 15mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock fixed in repair complete all as specified and directed. | 60 | Each | |
20 | 20 | Water tank suitable for desert cooler of capacity 5000/4000 cum/hour, fabricated with 1.00 mm thick mild steel galvanized iron sheet including gas welding at joint and testing for water tightness of apply one coat of red oxide primer including taking down old unserviceable complete all as specified and directed. | 20 | Each | |
21 | 21 | Preparation of old painted surface of capacity 40/80, 60/120 & 150/150 litre water cooler, externally and internally including compressor chamber, motor and applying one coat of synthetic enamel paint with applying a one coat of synthetic enamel paint with spray machine including re-writing MES No. etc. complete all as specified and directed. | 20 | Each Job | |
22 | 22 | Removing condenser Fan Motor from water cooler of capacity 40/80, 60/120 & 150/150 litres and rewinding the same with super enameled copper winding wire same gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed | 35 | Each Job | |
23 | 23 | Float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 140 grams complete all as specified and directed.\n | 85 | Each | |
24 | 24 | 15mm bore water tap (Internal thread), cast copper alloy, chromium plated push type suitable for water cooler of any capacity fixed in repair complete all as specified and directed. | 40 | Each | |
25 | 25 | Thermostat suitable for water cooler of any capacity fixed in repair complete all as specified and directed by Engr-in-Charge.\n | 35 | Each | |
26 | 26 | Waste water adaptor PVC, 32mm size suitable for water cooler of any capacity fixed in repair complete all as specified and directed by Engr-in-Charge.\n\n | 55 | Each | |
27 | 27 | Relay with Over Load Protector suitable for 40 to 150 liters cooling capacity water cooler complete all as specified and directed by Engr-in-Charge. | 20 | Each | |
28 | 28 | PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity fixed in repair complete all as specified and directed. | 45 | RM | |
29 | 29 | Galvanized steel water tubing medium grade of 15mm bore with & including all fittings complete, fixed to walls and ceilings or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed. | 32 | RM | |
30 | 30 | New freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning including cutting and removing old unserviceable freezer unit of refrigerator capacity 165/170/175/300/310/510 litres of any make complete all as specified and directed by Engr-in-Charge. | 6 | Each Job | |
31 | 31 | Thermostat suitable for refrigerator of capacity 165 to 180 liters fixed in repair complete all as specified and directed by Engr-in-Charge. | 12 | Each | |
32 | 32 | Compressor suitable for water cooler of capacity 40/80 litre/hour as required including necessary connections and testing fixed in repair complete all as specified and directed. | 14 | Each Job | |
33 | 33 | Compressor suitable for water cooler of capacity 60/120 litre/hour as required including necessary connections and and testing complete all as specified and directed by Engr-in-Charge. | 12 | Each Job | |
34 | 34 | Compressor suitable for water cooler of capacity 150/150 litre/hour as required including necessary connections and testing fixed in repair complete all as specified and directed by Engr-in-Charge. | 16 | Each Job | |
35 | 35 | Compressor suitable for Refrigertor of capacity 165/175/185 litre as required including necessary connections and testing fixed in repair complete all as specified and directed by Engr-in-Charge. | 14 | Each Job | |
36 | 36 | Compressor suitable for Refrigertor of capacity 285/300/310 litre as required including necessary connections and testing fixed in repair complete all as specified and directed by Engr-in-Charge. | 12 | Each Job | |
37 | 37 | Condensing coil suitable for water cooler of capacity 40/80, 60/120 & 150/150 litre fixed in repair complete all as specified and directed by Engr-in-Charge. | 10 | Each Job | |
38 | 38 | Supply only refrigerant gas R-22 for charging where required at site as per direction of Engineer-in-Charge | 120 | Kg | |
39 | 39 | Supply only refrigerant gas R-134a/407c for charging complete all as specified and directed by Engr-in-Charge. | 120 | Kg | |
40 | 40 | Servicing of Deep freezer of capacity 265/320/492 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and directed by Engr-in-Charge. | 10 | Each Job | |
41 | 41 | Preparation of external old painted surface of Deep freezer of capacity 405/492 liters of any makes including denting of minor patches and applying one coat of Duco paint with spray machine complete all as specified and directed by Engr-in-Charge. | 3 | Each Job | |
42 | 42 | Compressor suitable for Deep Freezer of capacity 300/320 litre/hour as required including necessary connections and testing fixed in repair complete all as specified and directed by Engr-in-Charge. | 2 | Each Job | |
43 | 43 | Compressor suitable for Deep Freezer of capacity 500 litre/hour as required including necessary connections and testing fixed in repair complete all as specified and directed by Engr-in-Charge. | 3 | Each Job | |
44 | 44 | Condenser coil suitable for Deep freezer of capacity 325 Litres fixed in repair complete all as specified and directed by Engr-in-Charge. | 8 | Each Job | |
45 | 45 | 10 to 20 Amp capacity, metal clad box with top plug and socket, 20 to 40 Amp, MCB capacity fixed in repair complete all as specified and directed. | 65 | Each Job | |
46 | 46 | Finding out the leakage with the pressure test of condenser or cooling coil of water cooler capacity 40/80, 60/120 & 150/150 litre cooling/storage and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/ soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and directed. | 30 | Each Job | |
47 | 47 | Finding out the leakage with the pressure test of the condenser or cooling coil of Rerigerator of capacity 165/170/175/300/310 litres and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and directed. | 14 | Each Job | |
48 | 48 | Cooling coil suitable for Deep freezer of capacity 300/500 liters fixed in repair complete all as specified and directed | 3 | Each | |
49 | 49 | Condenser coil assembly suitable for Split type Air Conditioner 1.5/2.0 TR fixed in repair complete all as specified and directed. | 8 | Each Job | |
50 | 50 | Condenser coil Assembly 1.5/2.0 TR suitable for window type Air Conditioner fixed in repair complete all as specified and directed. | 6 | Each Job | |
51 | 51 | Coil Evaporator Assembly suitable for 1.5/2.0 TR window type Air Conditioner fixed in repair complete all as specified and directed. | 4 | Each Job | |
52 | 52 | Condenser/Blower Motor of split/window type Air Conditioner of Capacity 1.5/2.0 TR fixed in repair complete all as specified. | 32 | Each Job | |
53 | 53 | Servicing of split type Air Conditioner of capacity 1.5/2.0 TR of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins and checking / testing of all parts for its serviceability, and oiling/greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete unit including testing for smooth functioning complete all as specified and directed. | 160 | Each Job | |
54 | 54 | Servicing of window type Air Conditioner of capacity 1.5/2 TR of any type or make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking/testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn-out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified and directed.\nNote for serial item No 53.00 & 54.00\n(i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Sch 'A' price schedule \n(ii) Any spare part of AC if found defective will be measured as supply and fix fixed in repairs under respective item of this Sch 'A' price schedule. | 65 | Each Job | |
55 | 55 | Wire remote control (Micro processor) unit suitable for split type Air Conditioner 1.5 / 2.0 TR capacity of make AMTREX complete with wires of remote fixed in repair complete all as specified and directed. | 35 | Each | |
56 | 56 | Shifting of Split type Air Conditioner 1.5/2.0 TR from one site to another by completely removing it from the existing place wihout any damage,and shifting it to new site including gas charging to required level comissioning and testing it to complete all as specified and directed. | 25 | Each Job | |
57 | 57 | Shifting of Window type AC 1.5/2.0 TR from one site to another by completely removing it from the existing place wihout any damage, and shifting it to new site making necessary cuttung in the wall making it good, including gas charging to required level comissioning and testing it to complete all as specified and directed. | 35 | Each Job | |
58 | 58 | Suction lines copper pipes of suitable size as per site requirement fixed in repair complete all as specified and directed. | 160 | RM | |
59 | 59 | Discharge lines copper pipes of suitable size as per site requirement fixed in repair complete all as specified and directed. | 160 | RM | |
60 | 60 | Sleeve foam Protection suitable for Split type Air Conditioner 1.5/2.0 TR fixed in repair complete all as specified and directed. | 360 | RM | |
61 | 61 | Factory made PVC drain pipe suitable for Split type Air Conditioner 1.5/2.0 TR with coupler Joint fixed in repair complete all as specified and directed. | 45 | Each | |
62 | 62 | Removing the condenser fan motor from split type Air Conditioner of capacity 1.5/2.0 TR, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts complete all as specified and directed. | 26 | Each | |
63 | 63 | Circuit kit of window type Air Conditioner complete with lugs, thimble and selector switch fixed in repair complete all as specified and directed. | 20 | Each Set | |
64 | 64 | Running capacitor, 36 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed in repair complete all as specified and directed. | 60 | Each | |
65 | 65 | Running capacitor, 45 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed in repair complete all as specified and directed. | 55 | Each | |
66 | 66 | Starting capacitor 2.50 MFD suitable for Air Conditioner of capacity 1.5/2.0 TR fixed in repair complete all as specified and directed. | 42 | Each | |
67 | 67 | Aluminium fan blade suitable for condenser of window/Split type Air Conditioner of any capacity and any type or make complete all as specified and directed. | 30 | Each | |
68 | 68 | PVC fan blade suitable for condenser/Blower of window/split type Air Conditioner of any capacity and any type or make fixed in repair complete all as specified and directed. | 35 | Each | |
69 | 69 | Starting relay only suitable for window/split type Air Conditioner 1.5/2.0 TR capacity and any type or make fixed in repair complete all as specified and directed. | 30 | Each | |
70 | 70 | Over load protector only suitable for window/split type Air Conditioner 1.5/2.0 TR capacities and any type or make fixed in repair complete all as specified and directed. | 25 | Each | |
71 | 71 | Reciprocating compressor sealed unit for window type Air Conditioner of capacity 1.5/2.0 TR and including testing for smooth functioning and including taking down old unserviceable compressor complete all as specified and directed. | 16 | Each Job | |
72 | 72 | Rotary compressor sealed unit for window/split type Air Conditioner of capacity 1.5/2.0 TR and including testing for smooth functioning and including taking down old unserviceable compressor complete all as specified and directed. | 24 | Each Job | |
73 | 73 | Thermostat suitable for window/split type Air Conditioner 1.5/2.0 TR capacity fixed in repair complete all as specified and directed. | 40 | Each Job | |
74 | 74 | Cooling fan motor of capacity 1/30 HP or 1/20 HP from split type Air Conditioner, rewinding the same with supper enamelled copper winding wire of existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush and side rubber ring and removing and re-fixing in original position complete including testing complete all as specified and directed. | 40 | Each Job | |
75 | 75 | Removing unserviceable window/split type Air Conditioner checking its leakage, brazing and completely arresting its leakage, gas charging and testing complete all as specified and directed. | 36 | Each Job | |
76 | 76 | Cooling coil suitable for window/split type Air Conditioner of capacity 1.5/2.0 TR including checking its leakage, brazing and completely arresting its leakage, gas charging and testing and any type or make fixed in repair complete all as specified and directed. | 16 | Each Job | |
77 | 77 | Wiring for electric Supply from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS single core, 3 run with 5.00 mtr for split type Air Conditioner 1.5/2.0 TR capacity inclduing taking down old unserviceable complete all as specified and directed. | 30 | Each Job | |
78 | 78 | Contactor 16 Amp, 4 pole suitable for split/window type Air Conditioner upto 2.0TR fixed in repair complete all as specified and directed. | 18 | Each Job | |
79 | 79 | Contactor 6 to 12 Amp, 4 pole suitable for split/window type Air Conditioner upto 2.0 TR fixed in repair complete all as specified and directed. | 16 | Each Job | |
80 | 80 | Over load relay 3 Pole, 5 to 16 Amps suitable for split/windwo type Air Conditioner upto 2.0 TR fixed in repair complete all as specified and directed. | 14 | Each Job | |
81 | 81 | Universal Cordless Remote For any type of window/Split type Air Conditioner 1.5/2.0 TR fixed in repair complete all as specified and directed. | 40 | Each | |
82 | 82 | PCB Plate Control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity any type of Make fixed in repair complete all as specified and directed. | 12 | Each | |
83 | 83 | Metal claid Top Plug and socket of Capacity 20 Amp 240 volt (ISI Marked) fixed in repair complete all as specified and directed. | 65 | Each | |
84 | 84 | Power socket 15 Amp with plug top, ISI Marked including taking down old unserviceable complete all as specified and directed. | 45 | Each | |
85 | 85 | PTFE Thread Seal Tape 12mmx10m complete all as specified and directed. | 40 | Each | |
86 | 86 | Taking down carefully and dismantling of ceiling fan/wall mounted fan/ pedestal fan/ exhaust fan of any make or model and sweep by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition with & including replacing defective components such as bearing, rubber bush/bolt, gunmetal bush, capacitor burnt windings flexible cord, worn out screws of the cover, split pin, twin core flexible copper wire of size 23/0.0076, locking nuts & machine screws with spring washer for ceiling fan blades, oiling and greasing etc, reassembling & testing the fan complete all as directed. Note :- (i) Minor spare Parts i.e locking nuts & mechine screws with spring washer, bolt included in quoted rates.\n(ii) Spare Parts/accessories found unserviceable & required to be replaced shall be measured and paid for separately under relevant items as “Supply only”. \n(iii) Rewinding shall also be measured & paid for separately.\n | 935 | Each Job | |
87 | 87 | Rewinding of ceiling Fan of size 1200mm/1400mm sweep, 230 volts, 50Hz, AC including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding the same with super enmelled copper winding wire of same gauge, same weight and same number of turns as that of existing and connecting the coils suitable to operate, capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush, rubber bush/bolt, capacitor, flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed. | 700 | Each Job | |
88 | 88 | Rewinding of wall mounted Fan of size 450mm sweep, 230 volts, 50Hz, AC including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding the same with super enmelled copper winding wire of same gauge, same weight and same number of turns as that of existing and connecting the coils suitable to operate, capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush, rubber bush/bolt, capacitor, flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed. | 25 | Each Job | |
89 | 89 | Rewinding of exhaust Fan of size 230/300mm sweep, 230 volts, 50Hz, AC including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding the same with super enmelled copper winding wire of same gauge, same weight and same number of turns as that of existing and connecting the coils suitable to operate, capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush, rubber bush/bolt, capacitor, flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed.\n | 150 | Each Job | |
90 | 90 | Rewinding of exhaust Fan of size 450/600mm sweep, 230 volts, 50Hz, AC including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding the same with super enmelled copper winding wire of same gauge, same weight and same number of turns as that of existing and connecting the coils suitable to operate, capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush, rubber bush/bolt, capacitor, flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed.\nNote:- Serial item No. 87.00 to 90.00 above bearing/Gunmetal bush/rubber bush bolt/capacitor/cord flexible wire/shaft/painting shall be measured and paid separately under respective items. | 60 | Each Job | |
91 | 91 | Supply only PVC flexible copper conductor, twin core size 23/0076 all as specified and directed. | 390 | RM | |
92 | 92 | Supply only capacitor of 2.50 Mfd 440/500 volts suitable for ceiling Fan all as specified and directed. | 600 | Each | |
93 | 93 | Supply only capacitor of 4.0 Mfd 440/500 volts suitable for Ceiling/Exhaust/Wall mounted Fan all as specified and directed. | 40 | Each | |
94 | 94 | Supply only ball bearing suitable for Ceiling Fan of any Sweep any make / model all as specified and directed. | 350 | Each | |
95 | 95 | Supply only ball bearing suitable for Exhaust Fan / wall mounted Fan any make / model / sweep complete all as specified and directed. | 50 | Each | |
96 | 96 | Supply only gunmetal bush suitable for ceiling Fan/wall mounting Fan of any make/ model/ sweep of size 1200/1400mm and Exhaust Fan of any sweep all as specified and directed. | 350 | Each | |
97 | 97 | Supply only rubber bush/bolt suitable for Ceiling Fan of any make/model /sweep of 1200/1400 mm all as specified and directed. | 500 | Each | |
98 | 98 | Supply only shaft suitable for ceiling fan / Exhaust fan/ wall mounted fan of any make/model and sweep with necessary machining work complete all as specified and directed. | 100 | Each | |
99 | 99 | Grouting in the bottom of the fan by lathe for fitting of bearing in bottom with bushing and all as directed. | 100 | Each | |
100 | 100 | Regulator electronic rotary step type suitable for ceiling fan of sweep 1200/1400mm fixed in repair complete all as specified and directed. | 250 | Each | |
101 | 101 | Point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC meduim duty casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in & including factory made MS/pressed steel terminal box with zinc coated duly concealed in wall for mounting fittings like switches, sockets, fan regulators etc with and including 3mm thick plastic laminated sheet top cover, including taking down old unserviceable point wiring complete all as specified & directed. | 50 | Per Point | |
102 | 102 | All as per serial item No. 101.00 here-in-before but for one bell/buzzer point controlled by one bell push. | 20 | Per Point | |
103 | 103 | All as per serial item No. 101.00 here-in-before but for one fan point controlled by one switch and regulator. | 70 | Per Point | |
104 | 104 | All as per serial item No. 101.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. | 35 | Per Point | |
105 | 105 | All as per serial item No. 101.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board. | 40 | Per Point | |
106 | 106 | Point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC meduim duty casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in & including factory made MS/pressed steel terminal box with zinc coated duly concealed in wall for mounting fittings like switches, sockets, fan regulators etc with and including 3mm thick plastic laminated sheet top cover, including taking down old unserviceable point wiring complete all as specified & directed. | 50 | Per Point | |
107 | 107 | Ceiling rose surface bakelite 2 to 3 terminals 65x50mm fixed in repair complete all as specified and directed. | 120 | Each | |
108 | 108 | Switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts (ISI Marked) fixed in repair complete all as specified and directed. | 195 | Each | |
109 | 109 | Socket outlet 3 pin 5 Amps flush type (ISI Marked) fixed in repair complete all as specified and directed. | 75 | Each | |
110 | 110 | Socket outlet 2 in 1, 6 pin 5 and 15 Amps flush type (ISI Marked) fixed in repair complete all as specified and directed. | 50 | Each | |
111 | 111 | Switch piano type 230 volts, single pole one way 15 Amps, 230 volts (ISI Marked) fixed in repair complete all as specified and directed. | 50 | Each | |
112 | 112 | Calling bell AC 230 volts type including necessary rectangular wooden block fixed in repair complete all as specified and directed. | 20 | Each | |
113 | 113 | Bell push switch piano type (ISI Marked) fixed in repair complete all as specified and directed. | 20 | Each | |
114 | 114 | Ceiling Fan 1200mm sweep single phase, AC supply, 240 Volt, including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd, and including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan including marking of MES number complete all as specified and as directed.\n(Note : Length of suspension rod shall be adjusted by cutting, threading as directed and its cost is deemed to be included in rate of hanging of ceiling fan). | 50 | Each | |
115 | 115 | Exhaust Fan 250mm sweep, BEE approved, ISI Marked with mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed by using 4 Nos, bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed. | 35 | Each | |
116 | 116 | Wall mounting 400mm sweep heavy duty, BEE approved, 240 volts, single phase ISI marked with built in selector switch including making connection by using PVC sheathed twin core copper cable from ceiling rose to wall mounting wall complete all as specified. Note:- (i) Wall mounting fan including marking of MES number is to be fixed on wall with all necessary T&P and other accessories required shall be deemed to be included in the above item no extra payment will be admissiable on this account.\n(ii) After taking down old unserviceable material from serial item No. 114.00 to 116.00 shall be deposited to MES store by the contractor. | 15 | Each | |
117 | 117 | Sub main wiring with 6.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 6.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. \nNote : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit. | 70 | RM | |
118 | 118 | Sub main wiring with 4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit including taking down old unserviceable submain wiring complete all as specified and directed. \nNote : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit. | 80 | RM | |
119 | 119 | Sheet metal enclosure factory made TPN 415 volt 4 way double door suitable for fixing MCB as outgoing and incoming MCCB 3 Pole, 63 Amps, repturing capacity 16 KA as main incoming duly painted including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete including dismantling and taking down old unserviceable complete all as specified and directed. | 5 | Each | |
120 | 120 | Sheet metal enclosure powder coated single phase DB SPN 8 ways and neutal 250 Volts with 200 Amps rated bus bar double door suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including dismantling and taking down old unserviceable complete all as specified and directed. | 15 | Each | |
121 | 121 | Sheet metal enclosure powder coated single phase DB SPN 4 ways and neutal 250 Volts with 200 Amps rated bus bar double door suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete including dismantling and taking down old unserviceable complete all as specified and directed. | 5 | Each | |
122 | 122 | MCB Single Pole with neutral 6 to 30 Amps, 240 Volts, repturing capacity 10 kA (ISI Marked) fixed in repair complete all as specified and directed. | 30 | Each | |
123 | 123 | MCB Single Pole 6 to 30 Amps, 240 Volts, repturing capacity 10 kA (ISI Marked) fixed in repair complete all as specified and directed. | 50 | Each | |
124 | 124 | Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI earth wire 4mm dia size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 5 of SSR Part-I 2009 including dismantling and taking down old unserviceable complete all as specified and directed. | 4 | Each Set |