Public Health And Engineering Department has published Execution Of The Work Of Hindoli Nainwa Water Supply Project District Bundi From Chambal- Bhilwara Wsp(Phase-I)On Lump Sump Basis, Single Responsibility Trun Key Job With 01 Year Defect Liability Piped Followed By 10 Years O&M , Tehsil Hindoli & Nainwa, D. Submission Date for this Tender is 05-07-2021. Water Supply Project Tenders in Bundi Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 11-May-2021 | Corrigendum1 | Date | 31-05-2021 |
2 | 13-May-2021 | Corrigendum 2 | Technical Bid | 31-05-2021 |
3 | 24-May-2021 | Corrigendum 3 | Technical Bid | 31-05-2021 |
4 | 29-May-2021 | Corrigendum 04 | Date | 15-06-2021 |
5 | 15-Jun-2021 | Corrigendum 5 | Date | 05-07-2021 |
Name of Work:Execution of the work of Hindoli Nainwa water supply project District Bundi from Chambal- Bhilwara WSP(Phase-I)on lump sump basis, single Responsibility trun key Job with 01 year defect liability piped followed by 10 years O&M , Tehsil Hindoli & Nainwa, District Bundi. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | General Components | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7/ K-9 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)\nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | BI01010001010000000000000515BI0100001113 | ||
3 | 1.02 | DI K-7 Pipe Line | BI01010001010000000000000515BI0100001114 | ||
4 | 1.03 | 80 mm Dia | BI01010001010000000000000515BI0100001115 | 128033 | Meter |
5 | 1.04 | 100 mm dia | BI01010001010000000000000515BI0100001116 | 279380 | Meter |
6 | 1.05 | 150 mm dia | BI01010001010000000000000515BI0100001117 | 275137 | Meter |
7 | 1.06 | 200 mm dia | BI01010001010000000000000515BI0100001118 | 125290 | Meter |
8 | 1.07 | 250 mm dia | BI01010001010000000000000515BI0100001119 | 102586 | Meter |
9 | 1.08 | 300 mm dia | BI01010001010000000000000515BI0100001120 | 2835 | Meter |
10 | 1.09 | 350 mm dia | BI01010001010000000000000515BI0100001121 | 14538 | Meter |
11 | 1.1 | 400 mm dia | BI01010001010000000000000515BI0100001122 | 15069 | Meter |
12 | 1.11 | 500 mm dia | BI01010001010000000000000515BI0100001123 | 14848 | Meter |
13 | 1.12 | 600 mm dia | BI01010001010000000000000515BI0100001124 | 30675 | Meter |
14 | 1.13 | 700 mm dia | BI01010001010000000000000515BI0100001125 | 28436 | Meter |
15 | 1.14 | DI K-9 Pipe Line | BI01010001010000000000000515BI0100001126 | ||
16 | 1.15 | 100 mm dia | BI01010001010000000000000515BI0100001127 | 21009 | Meter |
17 | 1.16 | 150 mm dia | BI01010001010000000000000515BI0100001128 | 44681 | Meter |
18 | 1.17 | 200 mm dia | BI01010001010000000000000515BI0100001129 | 79954 | Meter |
19 | 1.18 | 250 mm dia | BI01010001010000000000000515BI0100001130 | 39856 | Meter |
20 | 1.19 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. \nNote: Deduct rate for above item of E/W for pipe line, in case of road cutting, deduct 10% for each layer of 100 mm thick road cut i.e. 20% for 200 mm thick and so on. | BI01010001010000000000000515BI0100001131 | ||
21 | 1.2 | In all type of soil | BI01010001010000000000000515BI0100001132 | ||
22 | 1.21 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001133 | 249090 | RMT |
23 | 1.22 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001134 | 110019 | RMT |
24 | 1.23 | For dia of pipe above 350 mm and up to 700 mm nominal. | BI01010001010000000000000515BI0100001135 | 26708 | RMT |
25 | 1.24 | In soft Rock | BI01010001010000000000000515BI0100001136 | ||
26 | 1.25 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001137 | 322087 | RMT |
27 | 1.26 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001138 | 160875 | RMT |
28 | 1.27 | For dia of pipe above 350 mm and up to 700 mm nominal. | BI01010001010000000000000515BI0100001139 | 35611 | RMT |
29 | 1.28 | In Hard Rock ( required blasting) | BI01010001010000000000000515BI0100001140 | ||
30 | 1.29 | For dia of pipe up to 150 mm nominal. | BI01010001010000000000000515BI0100001141 | 102239 | RMT |
31 | 1.3 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001142 | 57660 | RMT |
32 | 1.31 | For dia of pipe above 350 mm and up to 700 mm nominal. | BI01010001010000000000000515BI0100001143 | 17806 | RMT |
33 | 1.32 | In Hard Rock ( Blasting prohibited) | BI01010001010000000000000515BI0100001144 | ||
34 | 1.33 | For dia of pipe up to 150 mm nominal. | BI01010001010000000000000515BI0100001145 | 74824 | RMT |
35 | 1.34 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001146 | 36506 | RMT |
36 | 1.35 | For dia of pipe above 350 mm and up to 700 mm nominal. | BI01010001010000000000000515BI0100001147 | 8902 | RMT |
37 | 1.36 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.\nSupply of pipe shall be in straight length in 6/12 M. | BI01010001010000000000000515BI0100001148 | ||
38 | 1.37 | HDPE PN-6 PE 80 | BI01010001010000000000000515BI0100001149 | ||
39 | 1.38 | 75mm | BI01010001010000000000000515BI0100001150 | 255492 | Meter |
40 | 1.39 | 90mm | BI01010001010000000000000515BI0100001151 | 243842 | Meter |
41 | 1.4 | 110mm | BI01010001010000000000000515BI0100001152 | 173200 | Meter |
42 | 1.41 | 125mm | BI01010001010000000000000515BI0100001153 | 82121 | Meter |
43 | 1.42 | 140mm | BI01010001010000000000000515BI0100001154 | 93348 | Meter |
44 | 1.43 | 160mm | BI01010001010000000000000515BI0100001155 | 66358 | Meter |
45 | 1.44 | 180mm | BI01010001010000000000000515BI0100001156 | 44104 | Meter |
46 | 1.45 | 200mm | BI01010001010000000000000515BI0100001157 | 7516 | Meter |
47 | 1.46 | 225 mm | BI01010001010000000000000515BI0100001158 | 40588 | Meter |
48 | 1.47 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. \nNote: Deduct rate for above item of E/W for pipe line, in case of road cutting, deduct 10% for each layer of 100 mm thick road cut i.e. 20% for 200 mm thick and so on. | BI01010001010000000000000515BI0100001159 | ||
49 | 1.48 | In all type of soil | BI01010001010000000000000515BI0100001160 | ||
50 | 1.49 | For HDPE pipe line dia up to 110 mm | BI01010001010000000000000515BI0100001161 | 201760 | RMT |
51 | 1.5 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001162 | 52641 | RMT |
52 | 1.51 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001163 | 47569 | RMT |
53 | 1.52 | In soft Rock | BI01010001010000000000000515BI0100001164 | ||
54 | 1.53 | For HDPE pipe line dia up to 110 mm | BI01010001010000000000000515BI0100001165 | 470774 | RMT |
55 | 1.54 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001166 | 122828 | RMT |
56 | 1.55 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001167 | 110996 | RMT |
57 | 1.56 | Providing bedding/ hunching for pipe with clean sand passing through IS sieve 2.36 mm and retained on 180 micron sieve in layers including ramming ,consolidation complete in all respect as per specification and the direction of the Engineer with all lead and lift. (Width of bedding = outer dia of pipe + 400 mm, thickness below pipe = 100 mm, haunch height = 300 mm, haunch width = 200 mm on both side of pipe) | BI01010001010000000000000515BI0100001168 | 12037.8 | Cum |
58 | 1.57 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. | BI01010001010000000000000515BI0100001169 | 140617 | Cum |
59 | 1.58 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. | BI01010001010000000000000515BI0100001170 | ||
60 | 1.59 | Bituminous courses | BI01010001010000000000000515BI0100001171 | 4420 | Cum |
61 | 1.6 | Granular courses | BI01010001010000000000000515BI0100001172 | 7350 | Cum |
62 | 1.61 | Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block, all lead and lift as per general specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) | BI01010001010000000000000515BI0100001173 | ||
63 | 1.62 | a) 60 mm thick. | BI01010001010000000000000515BI0100001174 | 159413 | Sqm. |
64 | 1.63 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. \nM10 grade Nominal Mix \n1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). | BI01010001010000000000000515BI0100001175 | 76194 | Cum |
65 | 1.64 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work. \nM20 grade Nominal Mix\n1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). | BI01010001010000000000000515BI0100001176 | 76193 | Cum |
66 | 1.65 | Supply & installation of DI Air Valves Temper proof with isolating sluice valve PN-1.6 size | BI01010001010000000000000515BI0100001177 | ||
67 | 1.66 | 50 mm dia | BI01010001010000000000000515BI0100001178 | 773 | No |
68 | 1.67 | 80 mm dia | BI01010001010000000000000515BI0100001179 | 125 | No |
69 | 1.68 | 100 mm dia | BI01010001010000000000000515BI0100001180 | 32 | No |
70 | 1.69 | 150 mm dia | BI01010001010000000000000515BI0100001181 | 79 | No |
71 | 1.7 | Construction of air valve Pillars | BI01010001010000000000000515BI0100001182 | 1009 | No |
72 | 1.71 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001183 | 1 | Lot |
73 | 2 | Raw Water Rising Main | BI01010001010000000000000515BI0100001184 | ||
74 | 2.01 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | BI01010001010000000000000515BI0100001185 | ||
75 | 2.02 | Minimum FID 800 MM (THK-8MM) MS Pipe | BI01010001010000000000000515BI0100001186 | 43700 | Meter |
76 | 2.03 | Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: \n3 LPE (3 Layer Polyethylene) Tape coating. | BI01010001010000000000000515BI0100001187 | 110124 | Sqm |
77 | 2.04 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water. | BI01010001010000000000000515BI0100001188 | 110124 | Sqm |
78 | 2.05 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. \nNote: Deduct rate for above item of E/W for pipe line, in case of road cutting, deduct 10% for each layer of 100 mm thick road cut i.e. 20% for 200 mm thick and so on. | BI01010001010000000000000515BI0100001189 | ||
79 | 2.06 | In all type of soil | BI01010001010000000000000515BI0100001190 | ||
80 | 2.07 | For dia of pipe above 700 mm and up to 1000 mm nominal. | BI01010001010000000000000515BI0100001191 | 4370 | RMT |
81 | 2.08 | In soft Rock | BI01010001010000000000000515BI0100001192 | ||
82 | 2.09 | For dia of pipe above 700 mm and up to 1000 mm nominal. | BI01010001010000000000000515BI0100001193 | 8740 | RMT |
83 | 2.1 | In Hard Rock ( required blasting) | BI01010001010000000000000515BI0100001194 | ||
84 | 2.11 | For dia of pipe above 700 mm and up to 1000 mm nominal. | BI01010001010000000000000515BI0100001195 | 17480 | RMT |
85 | 2.12 | In Hard Rock ( Blasting prohibited) | BI01010001010000000000000515BI0100001196 | ||
86 | 2.13 | For dia of pipe above 700 mm and up to 1000 mm nominal. | BI01010001010000000000000515BI0100001197 | 13110 | RMT |
87 | 2.14 | Installation of 800 mm Electromegnatic Flow Meter at Inlet of WTP compising of following items of 800 mm Size at Inlet of WTP | BI01010001010000000000000515BI0100001198 | ||
88 | 2.15 | Full Bore Electromegnatic Flow Meter 800 mm | BI01010001010000000000000515BI0100001199 | 1 | No |
89 | 2.16 | DI Resilient seated D/F Sluice Valves for scour valve 300mm- Manually Operated, PN-1.6 | BI01010001010000000000000515BI0100001200 | 13 | No |
90 | 2.17 | Construction of Scour Valve Chamber | BI01010001010000000000000515BI0100001201 | 13 | No |
91 | 2.18 | DI D/F resilient seated Manual Butterfly valve 800mm PN-1.0 | BI01010001010000000000000515BI0100001202 | 15 | No |
92 | 2.19 | Manually operated DI D/F resilient seated Sluice valve 800 mm PN-1.6 | BI01010001010000000000000515BI0100001203 | 3 | No. |
93 | 2.2 | CI Dismantling Joint - 800mm | BI01010001010000000000000515BI0100001204 | 17 | No |
94 | 2.21 | Construction of Flow Meter Chamber | BI01010001010000000000000515BI0100001205 | 1 | No |
95 | 2.22 | Construction of Sectional Valve Chamber | BI01010001010000000000000515BI0100001206 | 15 | No |
96 | 2.23 | Provision for surge analysis & providing protection devices on the rising mains as required | BI01010001010000000000000515BI0100001207 | 1 | Lot |
97 | 2.24 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001208 | 1 | Lot |
98 | 3 | Clear Water Rising Main | BI01010001010000000000000515BI0100001209 | ||
99 | 3.01 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | BI01010001010000000000000515BI0100001210 | ||
100 | 3.02 | 100 mm dia 4.7 mm thick | BI01010001010000000000000515BI0100001211 | 500 | Meter |
101 | 3.03 | 150 mm dia 5 mm thick | BI01010001010000000000000515BI0100001212 | 500 | Meter |
102 | 3.04 | 200 mm dia 5 mm thick | BI01010001010000000000000515BI0100001213 | 500 | Meter |
103 | 3.05 | 250 mm dia 5 mm thick | BI01010001010000000000000515BI0100001214 | 500 | Meter |
104 | 3.06 | 300 mm dia 5 mm thick | BI01010001010000000000000515BI0100001215 | 200 | Meter |
105 | 3.07 | 350 mm dia 5 mm thick | BI01010001010000000000000515BI0100001216 | 500 | Meter |
106 | 3.08 | 400 mm dia 6 mm thick | BI01010001010000000000000515BI0100001217 | 200 | Meter |
107 | 3.09 | 500 mm dia 6 mm thick | BI01010001010000000000000515BI0100001218 | 150 | Meter |
108 | 3.1 | 600 mm dia 6 mm thick | BI01010001010000000000000515BI0100001219 | 150 | Meter |
109 | 3.11 | 700 mm dia 8 mm thick | BI01010001010000000000000515BI0100001220 | 150 | Meter |
110 | 3.12 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. \nNote: Deduct rate for above item of E/W for pipe line, in case of road cutting, deduct 10% for each layer of 100 mm thick road cut i.e. 20% for 200 mm thick and so on. | BI01010001010000000000000515BI0100001221 | ||
111 | 3.13 | In all type of soil | BI01010001010000000000000515BI0100001222 | ||
112 | 3.14 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001223 | 500 | RMT |
113 | 3.15 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001224 | 850 | RMT |
114 | 3.16 | For dia of pipe above 350 mm and up to 700 mm nominal. | BI01010001010000000000000515BI0100001225 | 325 | RMT |
115 | 3.17 | In soft Rock | BI01010001010000000000000515BI0100001226 | ||
116 | 3.18 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001227 | 500 | RMT |
117 | 3.19 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001228 | 850 | RMT |
118 | 3.2 | For dia of pipe above 350 mm and up to 700 mm nominal. | BI01010001010000000000000515BI0100001229 | 325 | RMT |
119 | 3.21 | Supply & installation of DI D/f Resilient seated Sluice Valves for scouring. | BI01010001010000000000000515BI0100001230 | ||
120 | 3.22 | PN 1.0 | BI01010001010000000000000515BI0100001231 | ||
121 | 3.23 | 100 mm dia | BI01010001010000000000000515BI0100001232 | 86 | No |
122 | 3.24 | 150 mm dia | BI01010001010000000000000515BI0100001233 | 11 | No |
123 | 3.25 | 200 mm dia | BI01010001010000000000000515BI0100001234 | 14 | No |
124 | 3.26 | 250 mm dia | BI01010001010000000000000515BI0100001235 | 9 | No |
125 | 3.27 | PN 1.6 | BI01010001010000000000000515BI0100001236 | ||
126 | 3.28 | 100 mm dia | BI01010001010000000000000515BI0100001237 | 60 | No |
127 | 3.29 | Construction of scour valve chambers | BI01010001010000000000000515BI0100001238 | 180 | No |
128 | 3.3 | Construction of sluice valve chamber at Junction points | BI01010001010000000000000515BI0100001239 | 152 | No |
129 | 3.31 | Construction of Water Meter Chamber | BI01010001010000000000000515BI0100001240 | 91 | No |
130 | 3.32 | Construction of sectionalizing valve chamber | BI01010001010000000000000515BI0100001241 | 29 | No |
131 | 3.33 | Provision for CI Specials/ fittings in Sluice Valve Chambers/ offtake chambers, water meter chamber & section valve chamber | BI01010001010000000000000515BI0100001242 | ||
132 | 3.34 | CI Fittings | BI01010001010000000000000515BI0100001243 | 272 | Lot |
133 | 3.35 | DI D/f Resilient seated Sluice Valves for Junction Chambers & Water Meter Chambers & Section Chamber | BI01010001010000000000000515BI0100001244 | ||
134 | 3.36 | PN 1.0 | BI01010001010000000000000515BI0100001245 | ||
135 | 3.37 | 100 mm dia | BI01010001010000000000000515BI0100001246 | 65 | No |
136 | 3.38 | 150 mm dia | BI01010001010000000000000515BI0100001247 | 73 | No |
137 | 3.39 | 200 mm dia | BI01010001010000000000000515BI0100001248 | 27 | No |
138 | 3.4 | 250 mm dia | BI01010001010000000000000515BI0100001249 | 15 | No |
139 | 3.41 | 300 mm dia | BI01010001010000000000000515BI0100001250 | 1 | No |
140 | 3.42 | 350 mm dia | BI01010001010000000000000515BI0100001251 | 6 | No |
141 | 3.43 | 400 mm dia | BI01010001010000000000000515BI0100001252 | 1 | No |
142 | 3.44 | 500 mm dia | BI01010001010000000000000515BI0100001253 | 1 | No |
143 | 3.45 | 600 mm dia | BI01010001010000000000000515BI0100001254 | 1 | No |
144 | 3.46 | 700 mm dia with gear box | BI01010001010000000000000515BI0100001255 | 1 | No |
145 | 3.47 | PN 1.6 | BI01010001010000000000000515BI0100001256 | ||
146 | 3.48 | 100 mm dia | BI01010001010000000000000515BI0100001257 | 11 | No |
147 | 3.49 | 150 mm dia | BI01010001010000000000000515BI0100001258 | 20 | No |
148 | 3.5 | 200 mm dia | BI01010001010000000000000515BI0100001259 | 40 | No |
149 | 3.51 | 250 mm dia | BI01010001010000000000000515BI0100001260 | 19 | No |
150 | 3.52 | CI Dismantling joint for Chambers & Sectionilizing valve | BI01010001010000000000000515BI0100001261 | ||
151 | 3.53 | 100 mm dia | BI01010001010000000000000515BI0100001262 | 130 | No |
152 | 3.54 | 150 mm dia | BI01010001010000000000000515BI0100001263 | 119 | No |
153 | 3.55 | 200 mm dia | BI01010001010000000000000515BI0100001264 | 72 | No |
154 | 3.56 | 250 mm dia | BI01010001010000000000000515BI0100001265 | 35 | No |
155 | 3.57 | 300 mm dia | BI01010001010000000000000515BI0100001266 | 1 | No |
156 | 3.58 | 350 mm dia | BI01010001010000000000000515BI0100001267 | 7 | No |
157 | 3.59 | 400 mm dia | BI01010001010000000000000515BI0100001268 | 7 | No |
158 | 3.6 | 500 mm dia | BI01010001010000000000000515BI0100001269 | 7 | No |
159 | 3.61 | 600 mm dia | BI01010001010000000000000515BI0100001270 | 12 | No |
160 | 3.62 | 700 mm dia | BI01010001010000000000000515BI0100001271 | 11 | No |
161 | 3.63 | Bulk Flow Meter (Magnetic Flow meter for water application with sensor cable, digital display, etc) compatible with GSM device | BI01010001010000000000000515BI0100001272 | ||
162 | 3.64 | 100 mm dia | BI01010001010000000000000515BI0100001273 | 54 | No |
163 | 3.65 | 150 mm dia | BI01010001010000000000000515BI0100001274 | 26 | No |
164 | 3.66 | 200 mm dia | BI01010001010000000000000515BI0100001275 | 5 | No |
165 | 3.67 | 250 mm dia | BI01010001010000000000000515BI0100001276 | 1 | No |
166 | 3.68 | 350 mm dia | BI01010001010000000000000515BI0100001277 | 1 | No |
167 | 3.69 | 400 mm dia | BI01010001010000000000000515BI0100001278 | 1 | No |
168 | 3.7 | 500 mm dia | BI01010001010000000000000515BI0100001279 | 1 | No |
169 | 3.71 | 600 mm dia | BI01010001010000000000000515BI0100001280 | 1 | No |
170 | 3.72 | 700 mm dia | BI01010001010000000000000515BI0100001281 | 1 | No |
171 | 3.73 | DI D/F Resilient seated Butterfly Valves manually operated as Sectionilizing Valves | BI01010001010000000000000515BI0100001282 | ||
172 | 3.74 | PN 1.0 | BI01010001010000000000000515BI0100001283 | ||
173 | 3.75 | 400 mm dia | BI01010001010000000000000515BI0100001284 | 5 | No |
174 | 3.76 | 500 mm dia | BI01010001010000000000000515BI0100001285 | 5 | No |
175 | 3.77 | 600 mm dia | BI01010001010000000000000515BI0100001286 | 10 | No |
176 | 3.78 | 700 mm dia | BI01010001010000000000000515BI0100001287 | 9 | No |
177 | 3.79 | Provision for surge analysis & providing protection devices on the rising mains as required | BI01010001010000000000000515BI0100001288 | 1 | Lot |
178 | 3.8 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001289 | 1 | Lot |
179 | 4 | Cluster Distribution system | BI01010001010000000000000515BI0100001290 | ||
180 | 4.01 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | BI01010001010000000000000515BI0100001291 | ||
181 | 4.02 | 80mm Dia 4.5 mm thk | BI01010001010000000000000515BI0100001292 | 1000 | Meter |
182 | 4.03 | 100mm Dia 4.7 mm thk | BI01010001010000000000000515BI0100001293 | 800 | Meter |
183 | 4.04 | 125mm Dia 5.0 mm thk | BI01010001010000000000000515BI0100001294 | 700 | Meter |
184 | 4.05 | 150mm Dia 5.0 mm thk | BI01010001010000000000000515BI0100001295 | 700 | Meter |
185 | 4.06 | 200mm Dia 5.0 mm thk | BI01010001010000000000000515BI0100001296 | 600 | Meter |
186 | 4.07 | 250mm Dia 5.0 mm thk | BI01010001010000000000000515BI0100001297 | 350 | Meter |
187 | 4.08 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. \nNote: Deduct rate for above item of E/W for pipe line, in case of road cutting, deduct 10% for each layer of 100 mm thick road cut i.e. 20% for 200 mm thick and so on. | BI01010001010000000000000515BI0100001298 | ||
188 | 4.09 | In all type of soil | BI01010001010000000000000515BI0100001299 | ||
189 | 4.1 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001300 | 1600 | RMT |
190 | 4.11 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001301 | 475 | RMT |
191 | 4.12 | In soft Rock | BI01010001010000000000000515BI0100001302 | ||
192 | 4.13 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. | BI01010001010000000000000515BI0100001303 | 1600 | RMT |
193 | 4.14 | For dia of pipe above 150 mm and up to 350 mm nominal. | BI01010001010000000000000515BI0100001304 | 475 | RMT |
194 | 4.15 | Construction of sluice valve chamber at Junction points | BI01010001010000000000000515BI0100001305 | 431 | No |
195 | 4.16 | Construction of sectionalizing valve chamber | BI01010001010000000000000515BI0100001306 | 12 | No |
196 | 4.17 | Construction of Village Transfer Chamber villages | BI01010001010000000000000515BI0100001307 | ||
197 | 4.18 | For end villages | BI01010001010000000000000515BI0100001308 | 288 | No |
198 | 4.19 | For Intermediate Villages | BI01010001010000000000000515BI0100001309 | 282 | No |
199 | 4.2 | Provision for CI Specials/ fittings in Sluice Valve Chambers at Junction Points, village transfer chambers etc.CI Specials for Chambers | BI01010001010000000000000515BI0100001310 | 1001 | Lot |
200 | 4.21 | DI D/f Resilient seated Sluice Valves PN 1.0 for JN Chambers, VTC & Sectionilizing chambers | BI01010001010000000000000515BI0100001311 | ||
201 | 4.22 | 80mm Dia | BI01010001010000000000000515BI0100001312 | 262 | No |
202 | 4.23 | 100mm Dia | BI01010001010000000000000515BI0100001313 | 441 | No |
203 | 4.24 | 125mm Dia | BI01010001010000000000000515BI0100001314 | 237 | No |
204 | 4.25 | 150mm Dia | BI01010001010000000000000515BI0100001315 | 417 | No |
205 | 4.26 | 200mm Dia | BI01010001010000000000000515BI0100001316 | 272 | No |
206 | 4.27 | 250mm Dia | BI01010001010000000000000515BI0100001317 | 236 | No |
207 | 4.28 | CI Dismantling joint for Chambers & Sectionilizing valve | BI01010001010000000000000515BI0100001318 | ||
208 | 4.29 | 80MM Dia | BI01010001010000000000000515BI0100001319 | 262 | No |
209 | 4.3 | 100mm Dia | BI01010001010000000000000515BI0100001320 | 441 | No |
210 | 4.31 | 125mm Dia | BI01010001010000000000000515BI0100001321 | 237 | No |
211 | 4.32 | 150mm Dia | BI01010001010000000000000515BI0100001322 | 417 | No |
212 | 4.33 | 200mm Dia | BI01010001010000000000000515BI0100001323 | 272 | No |
213 | 4.34 | 250mm Dia | BI01010001010000000000000515BI0100001324 | 236 | No |
214 | 4.35 | Bulk Flow Meter (Magnetic Flow meter for water application with sensor cable, digital display, etc) GSM Based | BI01010001010000000000000515BI0100001325 | ||
215 | 4.36 | 80mm Dia | BI01010001010000000000000515BI0100001326 | 122 | No |
216 | 4.37 | 100mm Dia | BI01010001010000000000000515BI0100001327 | 177 | No |
217 | 4.38 | 125mm Dia | BI01010001010000000000000515BI0100001328 | 79 | No |
218 | 4.39 | 150mm Dia | BI01010001010000000000000515BI0100001329 | 99 | No |
219 | 4.4 | 200mm Dia | BI01010001010000000000000515BI0100001330 | 49 | No |
220 | 4.41 | 250mm Dia | BI01010001010000000000000515BI0100001331 | 44 | No |
221 | 4.42 | Provision for surge analysis & providing protection devices on the rising mains as required | BI01010001010000000000000515BI0100001332 | 1 | Lot |
222 | 4.43 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001333 | 1 | Lot |
223 | 5 | Village Distribution System | BI01010001010000000000000515BI0100001334 | ||
224 | 5.01 | Provision for CWT in the villages | BI01010001010000000000000515BI0100001335 | 612 | No |
225 | 5.02 | Interconnections with existing pipelines of following size: | BI01010001010000000000000515BI0100001336 | ||
226 | 5.03 | 80 mm | BI01010001010000000000000515BI0100001337 | 20 | Each |
227 | 5.04 | 100 mm | BI01010001010000000000000515BI0100001338 | 20 | Each |
228 | 5.05 | 150 mm | BI01010001010000000000000515BI0100001339 | 10 | Each |
229 | 5.06 | Provision for sluice valves, dismantling joints, spectials & fittings in village distribution system and piped scheme | BI01010001010000000000000515BI0100001340 | 1447 | Lot |
230 | 5.07 | Construction of sluice valve chamber at Junction points | BI01010001010000000000000515BI0100001341 | 1447 | No |
231 | 5.08 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001342 | 1 | Lot |
232 | 6 | Raw Water Reservoir | BI01010001010000000000000515BI0100001343 | ||
233 | 6.01 | Construction of Raw Water Reservoir complete as per scope of work and specifications of the following sizes : | BI01010001010000000000000515BI0100001344 | ||
234 | 6.02 | At Aroli PH | BI01010001010000000000000515BI0100001345 | 4.6e+06 | Per Liter |
235 | 6.03 | Providing and fixing double flanged ISI marked DI classK- 9 pipes as per IS:8329-2000 (amended upto date), as cortical pipes for RCC reservoirs including specials required such as duckfoot bend, bend tee Etc. Providing clamps at every 3 MTR, jointing metrials such as nuts, bolt,rubber packing, hydraulic testing etc. Complete in all respect upto and form valve chamber as per direction of EIC, technical specification and scope of work. | BI01010001010000000000000515BI0100001346 | ||
236 | 6.04 | 300 mm | BI01010001010000000000000515BI0100001347 | 10 | mtr |
237 | 6.05 | 800 mm | BI01010001010000000000000515BI0100001348 | 10 | mtr |
238 | 6.06 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.(Category "A" " Make: Kirloskar Bros. Ltd., Indian Valve Co. (IVC), Fouress Engineers Pvt. Ltd., VAG) Manually operated class PN 1.0 | BI01010001010000000000000515BI0100001349 | ||
239 | 6.07 | 300 mm | BI01010001010000000000000515BI0100001350 | 1 | Nos |
240 | 6.08 | 800 mm with gear box | BI01010001010000000000000515BI0100001351 | 2 | Nos |
241 | 6.09 | CI Dismantling joint for Chamber. | BI01010001010000000000000515BI0100001352 | ||
242 | 6.1 | 300 mm | BI01010001010000000000000515BI0100001353 | 1 | Nos |
243 | 6.11 | 800 mm | BI01010001010000000000000515BI0100001354 | 2 | Nos |
244 | 6.12 | Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet | BI01010001010000000000000515BI0100001355 | 600 | Per Kg. |
245 | 6.13 | Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials above 600mm dia (with minimum 6.3 mm thickness sheet | BI01010001010000000000000515BI0100001356 | 600 | Per Kg. |
246 | 6.14 | Construction of Washout chamber at RWR Pumping station | BI01010001010000000000000515BI0100001357 | 1 | No. |
247 | 6.15 | Provision of C.I. sluice gates 1000x1000mm electrically operated with extended rod of min. 4.0 m at RWR | BI01010001010000000000000515BI0100001358 | 2 | No. |
248 | 6.16 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001359 | 1 | Lot |
249 | 7 | RAW WATER PUMPING STATION AT AROLI | BI01010001010000000000000515BI0100001360 | ||
250 | 7.01 | Civil Works | BI01010001010000000000000515BI0100001361 | ||
251 | 7.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001362 | ||
252 | 7.03 | At WTP Head work over Proposed 4600 KL CWR (For Installation of 2W+2S Pumps & 2 pumps for future). Pump house shall be constructed over RCC RWR. | BI01010001010000000000000515BI0100001363 | 200 | Sqm |
253 | 7.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001364 | ||
254 | 7.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001365 | ||
255 | 7.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001366 | ||
256 | 7.07 | Aroli to Jhakoli Khurd WTP route 284 LPS / 55 m head/ 241 KW (2W+2S) | BI01010001010000000000000515BI0100001367 | 4 | each |
257 | 7.08 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-6mm thk | BI01010001010000000000000515BI0100001368 | ||
258 | 7.09 | 500 mm Dia | BI01010001010000000000000515BI0100001369 | 20 | Meter |
259 | 7.1 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. -6mm thk | BI01010001010000000000000515BI0100001370 | ||
260 | 7.11 | 700 mm Dia | BI01010001010000000000000515BI0100001371 | 30 | Meter |
261 | 7.12 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001372 | ||
262 | 7.13 | 500 mm Dia | BI01010001010000000000000515BI0100001373 | 4 | No |
263 | 7.14 | 700 mm Dia | BI01010001010000000000000515BI0100001374 | 1 | No |
264 | 7.15 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001375 | ||
265 | 7.16 | 500 mm Dia | BI01010001010000000000000515BI0100001376 | 4 | No |
266 | 7.17 | 700 mm Dia | BI01010001010000000000000515BI0100001377 | 1 | No |
267 | 7.18 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001378 | ||
268 | 7.19 | 500 mm Dia | BI01010001010000000000000515BI0100001379 | 4 | No |
269 | 7.2 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001380 | ||
270 | 7.21 | 500 mm Dia | BI01010001010000000000000515BI0100001381 | 4 | No |
271 | 7.22 | DI Kinetic Air Valves of 150 mm diameter with isolating Sluice Valve of 150 mm size PN 1.6 Tamper proof | BI01010001010000000000000515BI0100001382 | 1 | No |
272 | 7.23 | EOT of minimum 3 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001383 | 1 | No |
273 | 7.24 | Glycerine filled pressure gauges (0-10 kg) | BI01010001010000000000000515BI0100001384 | 5 | No |
274 | 7.25 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001385 | ||
275 | 7.26 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001386 | 964 | KW |
276 | 7.27 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . | BI01010001010000000000000515BI0100001387 | 964 | KW |
277 | 7.28 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001388 | 964 | KW |
278 | 7.29 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001389 | ||
279 | 7.3 | For LT Panet & motors | BI01010001010000000000000515BI0100001390 | 4 | No |
280 | 7.31 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001391 | ||
281 | 7.32 | Inside Pump House | BI01010001010000000000000515BI0100001392 | 8 | No |
282 | 7.33 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001393 | 8 | each |
283 | 7.34 | Instrumentation | BI01010001010000000000000515BI0100001394 | ||
284 | 7.35 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001395 | ||
285 | 7.36 | D/F Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001396 | ||
286 | 7.37 | 700 mm dia | BI01010001010000000000000515BI0100001397 | 1 | No |
287 | 7.38 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) with gear box | BI01010001010000000000000515BI0100001398 | ||
288 | 7.39 | 700 mm dia | BI01010001010000000000000515BI0100001399 | 3 | No |
289 | 7.4 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001400 | ||
290 | 7.41 | 700 mm dia | BI01010001010000000000000515BI0100001401 | 2 | No |
291 | 7.42 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001402 | 1 | No |
292 | 7.43 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001403 | 1 | Lot |
293 | 8 | Water Treatment Plant | BI01010001010000000000000515BI0100001404 | ||
294 | 8.01 | Design, construction, execution, testing, commissioning & trial run of 45 MLD ( input capacity with maximum 3% losses) in 22 Hrs (49.05 MLD on 24 hour basis). Treatment Plant including all relevant civil, electrical and mechanical works, Stores, office along with ancillary civil works as per specifications and control system. | BI01010001010000000000000515BI0100001405 | 45 | MLD |
295 | 8.02 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001406 | 1 | Lot |
296 | 9 | Clear Water Reservoir | BI01010001010000000000000515BI0100001407 | ||
297 | 9.01 | Construction of RCC circular clear water reservoirs pf required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab/dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion and food grade epoxy paint to inner face of the container and dome/slab, including refilling and disposing of surplus stuff, all labour and material charges , providing and fixing accessories such as M.S/Aluminium ladder/RCC stairs inside and outside, manhole frame and cover, puddle collar , ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paint to all exposed surface of structure including dome etc. complete in all respect as per design data criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of scheme and other details on the reservoir and any other work related to structure as per the direction to Engineer-in-Charge technical specification and scope of work.The rate indicated below are excluding the cost of pipe, specials and valve required for inlet, outlet, washout, overflow arrangement : | BI01010001010000000000000515BI0100001408 | ||
298 | 9.02 | At WTP Campus | BI01010001010000000000000515BI0100001409 | 4.2e+06 | Per Liter |
299 | 9.03 | At IPS-1 (Bara Naya Gaon) | BI01010001010000000000000515BI0100001410 | 4.2e+06 | Per Liter |
300 | 9.04 | At IPS-2 (Hindoli) | BI01010001010000000000000515BI0100001411 | 900000 | Per Liter |
301 | 9.05 | At IPS-3 (Dablana) | BI01010001010000000000000515BI0100001412 | 2.3e+06 | Per Liter |
302 | 9.06 | At IPS-4 (Bansi) | BI01010001010000000000000515BI0100001413 | 1.8e+06 | Per Liter |
303 | 9.07 | At IPS-5 (Nainwa) | BI01010001010000000000000515BI0100001414 | 1.2e+06 | Per Liter |
304 | 9.08 | At IPS-6 (Dei) | BI01010001010000000000000515BI0100001415 | 500000 | Per Liter |
305 | 9.09 | Providing and fixing double flanged ISI marked DI classK- 9 pipes as per IS:8329-2000 (amended upto date), as cortical pipes for RCC reservoirs including specials required such as duckfoot bend, bend tee Etc. Providing clamps at every 3 MTR, jointing metrials such as nuts, bolt,rubber packing, hydraulic testing etc. Complete in all respect upto and form valve chamber as per direction of EIC, technical specification and scope of work. | BI01010001010000000000000515BI0100001416 | ||
306 | 9.1 | 200 mm | BI01010001010000000000000515BI0100001417 | 70 | mtr |
307 | 9.11 | 250 mm | BI01010001010000000000000515BI0100001418 | 15 | mtr |
308 | 9.12 | 350 mm | BI01010001010000000000000515BI0100001419 | 30 | mtr |
309 | 9.13 | 400 mm | BI01010001010000000000000515BI0100001420 | 15 | mtr |
310 | 9.14 | 450 mm | BI01010001010000000000000515BI0100001421 | 15 | mtr |
311 | 9.15 | 500 mm | BI01010001010000000000000515BI0100001422 | 30 | mtr |
312 | 9.16 | 600 mm | BI01010001010000000000000515BI0100001423 | 30 | mtr |
313 | 9.17 | 700 mm | BI01010001010000000000000515BI0100001424 | 30 | mtr |
314 | 9.18 | 800 mm | BI01010001010000000000000515BI0100001425 | 30 | mtr |
315 | 9.19 | 900 mm | BI01010001010000000000000515BI0100001426 | 15 | mtr |
316 | 9.2 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves with gear box of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.(Category "A" " Make: Kirloskar Bros. Ltd., Indian Valve Co. (IVC), Fouress Engineers Pvt. Ltd., VAG) Manually operated class PN 1.6 | BI01010001010000000000000515BI0100001427 | ||
317 | 9.21 | 200 mm | BI01010001010000000000000515BI0100001428 | 7 | Nos |
318 | 9.22 | 250 mm | BI01010001010000000000000515BI0100001429 | 1 | Nos |
319 | 9.23 | 350 mm | BI01010001010000000000000515BI0100001430 | 1 | Nos |
320 | 9.24 | 400 mm | BI01010001010000000000000515BI0100001431 | 1 | Nos |
321 | 9.25 | 500 mm | BI01010001010000000000000515BI0100001432 | 1 | Nos |
322 | 9.26 | 600 mm | BI01010001010000000000000515BI0100001433 | 1 | Nos |
323 | 9.27 | 700 mm with gear | BI01010001010000000000000515BI0100001434 | 1 | Nos |
324 | 9.28 | 800 mm with gear | BI01010001010000000000000515BI0100001435 | 1 | Nos |
325 | 9.29 | CI Dismantling Joint of following sizes on inlet & washout piping of following sizes | BI01010001010000000000000515BI0100001436 | ||
326 | 9.3 | 200 mm | BI01010001010000000000000515BI0100001437 | 7 | Nos |
327 | 9.31 | 250 mm | BI01010001010000000000000515BI0100001438 | 1 | Nos |
328 | 9.32 | 350 mm | BI01010001010000000000000515BI0100001439 | 1 | Nos |
329 | 9.33 | 400 mm | BI01010001010000000000000515BI0100001440 | 1 | Nos |
330 | 9.34 | 500 mm | BI01010001010000000000000515BI0100001441 | 1 | Nos |
331 | 9.35 | 600 mm | BI01010001010000000000000515BI0100001442 | 1 | Nos |
332 | 9.36 | 700 mm | BI01010001010000000000000515BI0100001443 | 1 | Nos |
333 | 9.37 | 800 mm | BI01010001010000000000000515BI0100001444 | 1 | Nos |
334 | 9.38 | Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet | BI01010001010000000000000515BI0100001445 | 2000 | Per Kg. |
335 | 9.39 | Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials above 600mm dia (with minimum 6.3 mm thickness sheet | BI01010001010000000000000515BI0100001446 | 800 | Per Kg. |
336 | 9.4 | Construction of Washout chamber at each CWR Pumping station | BI01010001010000000000000515BI0100001447 | 7 | No. |
337 | 9.41 | Providing, installation, testing, trial run and commissioning of the following, as per specifications at WTP | BI01010001010000000000000515BI0100001448 | ||
338 | 9.42 | D/F Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001449 | ||
339 | 9.43 | 800 mm | BI01010001010000000000000515BI0100001450 | 1 | No. |
340 | 9.44 | Manually operated DI D/F resilient seated Sluice Valves with gear box for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001451 | ||
341 | 9.45 | 800 mm | BI01010001010000000000000515BI0100001452 | 3 | No. |
342 | 9.46 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001453 | ||
343 | 9.47 | 800 mm | BI01010001010000000000000515BI0100001454 | 2 | No. |
344 | 9.48 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001455 | 1 | No. |
345 | 9.49 | Provision of C.I. sluice gates 1000x1000mm electrically operated with extended rod of min. 4.0 m at CWR | BI01010001010000000000000515BI0100001456 | 14 | No. |
346 | 9.5 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001457 | 1 | Lot |
347 | 10 | Clear Water Pump House at WTP | BI01010001010000000000000515BI0100001458 | ||
348 | 10.01 | Civil Works | BI01010001010000000000000515BI0100001459 | ||
349 | 10.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001460 | ||
350 | 10.03 | At WTP Head work over Proposed 4200 KL CWR (For Installation of 4W+4S Pumps & 2 pumps for future).Pump house shall be constructed over RCC CWR. | BI01010001010000000000000515BI0100001461 | 300 | Sqm |
351 | 10.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001462 | ||
352 | 10.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001463 | ||
353 | 10.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001464 | ||
354 | 10.07 | WTP to JN-1,P-SR JAKHOLI KHURD (HCL-2) route 18 LPS / 110 m head/45 KW (1W+1S) | BI01010001010000000000000515BI0100001465 | 2 | each |
355 | 10.08 | WTP to JN-02,Owan ESR (HCL-4),JN-03,JN-04,Datoonda ESR (HCL-06) route 37 LPS / 165 m head/120 KW (1W+1S) | BI01010001010000000000000515BI0100001466 | 2 | each |
356 | 10.09 | Wtp to IPS-1 (Baranayagaon) Via Datunda and Narayanpura ESR Route 231 LPS / 45 m head/161 KW (2W+2S) | BI01010001010000000000000515BI0100001467 | 4 | each |
357 | 10.1 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. | BI01010001010000000000000515BI0100001468 | ||
358 | 10.11 | 125 mm dia 5.2 mm thk | BI01010001010000000000000515BI0100001469 | 10 | Meter |
359 | 10.12 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001470 | 10 | Meter |
360 | 10.13 | 450 mm dia 6mm thk | BI01010001010000000000000515BI0100001471 | 20 | Meter |
361 | 10.14 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. | BI01010001010000000000000515BI0100001472 | ||
362 | 10.15 | 125 mm dia 5mm thk | BI01010001010000000000000515BI0100001473 | 40 | Meter |
363 | 10.16 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001474 | 40 | Meter |
364 | 10.17 | 700 mm dia 6mm thk | BI01010001010000000000000515BI0100001475 | 40 | Meter |
365 | 10.18 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001476 | ||
366 | 10.19 | 125 mm dia | BI01010001010000000000000515BI0100001477 | 3 | No |
367 | 10.2 | 200 mm dia | BI01010001010000000000000515BI0100001478 | 3 | No |
368 | 10.21 | 450 mm dia | BI01010001010000000000000515BI0100001479 | 4 | No |
369 | 10.22 | 700 mm dia | BI01010001010000000000000515BI0100001480 | 1 | No |
370 | 10.23 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001481 | ||
371 | 10.24 | 125 mm dia | BI01010001010000000000000515BI0100001482 | 3 | No |
372 | 10.25 | 200 mm dia | BI01010001010000000000000515BI0100001483 | 3 | No |
373 | 10.26 | 450 mm dia | BI01010001010000000000000515BI0100001484 | 4 | No |
374 | 10.27 | 700 mm dia | BI01010001010000000000000515BI0100001485 | 1 | No |
375 | 10.28 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001486 | ||
376 | 10.29 | 125 mm dia | BI01010001010000000000000515BI0100001487 | 2 | No |
377 | 10.3 | 200 mm dia | BI01010001010000000000000515BI0100001488 | 2 | No |
378 | 10.31 | 450 mm dia | BI01010001010000000000000515BI0100001489 | 4 | No |
379 | 10.32 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001490 | ||
380 | 10.33 | 125 mm dia | BI01010001010000000000000515BI0100001491 | 2 | No |
381 | 10.34 | 200 mm dia | BI01010001010000000000000515BI0100001492 | 2 | No |
382 | 10.35 | 450 mm dia | BI01010001010000000000000515BI0100001493 | 4 | No |
383 | 10.36 | DI Kinetic Air Valves of 100 mm diameter with isolating Sluice Valve of 100 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001494 | 2 | No |
384 | 10.37 | DI Kinetic Air Valves of 150 mm diameter with isolating Sluice Valve of 150 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001495 | 1 | No |
385 | 10.38 | EOT of minimum 3 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001496 | 1 | No |
386 | 10.39 | Glycerine filled pressure gauges (0-10KG) | BI01010001010000000000000515BI0100001497 | 11 | No |
387 | 10.4 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001498 | ||
388 | 10.41 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001499 | 974 | KW |
389 | 10.42 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . | BI01010001010000000000000515BI0100001500 | 974 | KW |
390 | 10.43 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001501 | 974 | KW |
391 | 10.44 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001502 | ||
392 | 10.45 | For LT Panet & motors | BI01010001010000000000000515BI0100001503 | 8 | No |
393 | 10.46 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001504 | ||
394 | 10.47 | Inside Pump House | BI01010001010000000000000515BI0100001505 | 8 | No |
395 | 10.48 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001506 | 8 | each |
396 | 10.49 | Instrumentation | BI01010001010000000000000515BI0100001507 | ||
397 | 10.5 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001508 | ||
398 | 10.51 | D/F Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001509 | ||
399 | 10.52 | 125 mm dia | BI01010001010000000000000515BI0100001510 | 1 | No |
400 | 10.53 | 200 mm dia | BI01010001010000000000000515BI0100001511 | 1 | No |
401 | 10.54 | 700 mm dia | BI01010001010000000000000515BI0100001512 | 1 | No |
402 | 10.55 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001513 | ||
403 | 10.56 | 125 mm dia | BI01010001010000000000000515BI0100001514 | 2 | No |
404 | 10.57 | 200 mm dia | BI01010001010000000000000515BI0100001515 | 3 | No |
405 | 10.58 | 700 mm dia with gear box | BI01010001010000000000000515BI0100001516 | 3 | No |
406 | 10.59 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001517 | ||
407 | 10.6 | 125 mm dia | BI01010001010000000000000515BI0100001518 | 1 | No |
408 | 10.61 | 200 mm dia | BI01010001010000000000000515BI0100001519 | 2 | No |
409 | 10.62 | 700 mm dia | BI01010001010000000000000515BI0100001520 | 2 | No |
410 | 10.63 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001521 | 1 | No |
411 | 10.64 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001522 | 1 | Lot |
412 | 11 | Intermediate Pumping Station at Badanayagaon | BI01010001010000000000000515BI0100001523 | ||
413 | 11.01 | Civil Works | BI01010001010000000000000515BI0100001524 | ||
414 | 11.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001525 | ||
415 | 11.03 | At Baranaya Gaon Head work for Installation of 7W+7S Pumps & 2 pumps for future).Pump house shall be constructed over RCC CWR. | BI01010001010000000000000515BI0100001526 | 350 | Sqm |
416 | 11.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001527 | ||
417 | 11.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001528 | ||
418 | 11.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001529 | ||
419 | 11.07 | IPS-1 (Baranayagaoan) to JN-21,JN-23,JN-24,JN-26,JN-28,Cheta ESR (HCL-35) route 57 LPS / 65 m head/76 KW (1W+1S) | BI01010001010000000000000515BI0100001530 | 2 | Each |
420 | 11.08 | IPS-1 (Baranayagaoan) to JN-5,JN-6,JN-7,EXT-SR BARODIYA (HCL-39) route 37 LPS / 85 m head/64 KW (1W+1S) | BI01010001010000000000000515BI0100001531 | 2 | Each |
421 | 11.09 | IPS-1 (Baranayagaoan) to IPS-3 Dablana/Bhawanipura route 125 LPS / 45 m head/87 KW (2W+2S) | BI01010001010000000000000515BI0100001532 | 4 | Each |
422 | 11.1 | IPS-1 (Baranayagaoan) to IPS-2 Hindoli route 81 LPS / 40 m head/61 KW (1W+1S) | BI01010001010000000000000515BI0100001533 | 2 | Each |
423 | 11.11 | IPS-1 (Baranayagaoan) to JN-10,JN-11,JN-14,P-SR DALELPURA (HCL-46),P-SR BHERUPURA ANTIR (HCL-37),JN-15,P-SR AKODA (HCL-36) route 46 LPS / 150 m head/135 KW (1W+1S) | BI01010001010000000000000515BI0100001534 | 2 | Each |
424 | 11.12 | IPS-1 (Baranayagaoan) to P-SR BOORKHERA (HCL-17),P-SR SALAWLAYA (HCL-18),P-SR VIJAYGARH (HCL-08),P-SR THANA (HCL-07),P-SR GOKULPURA (HCL-09) route 42 LPS / 170 m head/140 KW (1W+1S) | BI01010001010000000000000515BI0100001535 | 2 | Each |
425 | 11.13 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. | BI01010001010000000000000515BI0100001536 | ||
426 | 11.14 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001537 | 30 | Meter |
427 | 11.15 | 250 mm dia 5mm thk | BI01010001010000000000000515BI0100001538 | 10 | Meter |
428 | 11.16 | 300 mm dia 5mm thk | BI01010001010000000000000515BI0100001539 | 10 | Meter |
429 | 11.17 | 350 mm dia 5mm thk | BI01010001010000000000000515BI0100001540 | 20 | Meter |
430 | 11.18 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. -5mm thk | BI01010001010000000000000515BI0100001541 | ||
431 | 11.19 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001542 | 135 | Meter |
432 | 11.2 | 250 mm dia 5mm thk | BI01010001010000000000000515BI0100001543 | 45 | Meter |
433 | 11.21 | 300 mm dia 5mm thk | BI01010001010000000000000515BI0100001544 | 45 | Meter |
434 | 11.22 | 450 mm dia 6mm thk | BI01010001010000000000000515BI0100001545 | 45 | Meter |
435 | 11.23 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001546 | ||
436 | 11.24 | 200 mm dia | BI01010001010000000000000515BI0100001547 | 9 | No |
437 | 11.25 | 250 mm dia | BI01010001010000000000000515BI0100001548 | 3 | No |
438 | 11.26 | 300 mm dia | BI01010001010000000000000515BI0100001549 | 3 | No |
439 | 11.27 | 350 mm dia | BI01010001010000000000000515BI0100001550 | 4 | No |
440 | 11.28 | 450 mm dia | BI01010001010000000000000515BI0100001551 | 1 | No |
441 | 11.29 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001552 | ||
442 | 11.3 | 200 mm dia | BI01010001010000000000000515BI0100001553 | 9 | No |
443 | 11.31 | 250 mm dia | BI01010001010000000000000515BI0100001554 | 3 | No |
444 | 11.32 | 300 mm dia | BI01010001010000000000000515BI0100001555 | 3 | No |
445 | 11.33 | 350 mm dia | BI01010001010000000000000515BI0100001556 | 4 | No |
446 | 11.34 | 450 mm dia | BI01010001010000000000000515BI0100001557 | 1 | No |
447 | 11.35 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001558 | ||
448 | 11.36 | 200 mm dia | BI01010001010000000000000515BI0100001559 | 6 | No |
449 | 11.37 | 250 mm dia | BI01010001010000000000000515BI0100001560 | 2 | No |
450 | 11.38 | 300 mm dia | BI01010001010000000000000515BI0100001561 | 2 | No |
451 | 11.39 | 350 mm dia | BI01010001010000000000000515BI0100001562 | 4 | No |
452 | 11.4 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001563 | ||
453 | 11.41 | 200 mm dia | BI01010001010000000000000515BI0100001564 | 6 | No |
454 | 11.42 | 250 mm dia | BI01010001010000000000000515BI0100001565 | 2 | No |
455 | 11.43 | 300 mm dia | BI01010001010000000000000515BI0100001566 | 2 | No |
456 | 11.44 | 350 mm dia | BI01010001010000000000000515BI0100001567 | 4 | No |
457 | 11.45 | DI Kinetic Air Valves of 100 mm diameter with isolating Sluice Valve of 100 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001568 | 5 | No |
458 | 11.46 | DI Kinetic Air Valves of 150 mm diameter with isolating Sluice Valve of 150 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001569 | 1 | No |
459 | 11.47 | EOT of minimum 2 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001570 | 1 | No |
460 | 11.48 | Glycerine filled pressure gauges (0-10 kg) | BI01010001010000000000000515BI0100001571 | 20 | No |
461 | 11.49 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001572 | ||
462 | 11.5 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001573 | 1300 | KW |
463 | 11.51 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001574 | 1300 | KW |
464 | 11.52 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001575 | 1300 | KW |
465 | 11.53 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001576 | ||
466 | 11.54 | For LT Panet & motors | BI01010001010000000000000515BI0100001577 | 10 | No |
467 | 11.55 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001578 | ||
468 | 11.56 | Inside Pump House | BI01010001010000000000000515BI0100001579 | 6 | No |
469 | 11.57 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001580 | 12 | each |
470 | 11.58 | Construction of shed and providing Post chlorination System comprising of Supply & installation of chlorine tonners (2 nos. @ 900 kg) with vaccum chlorinator 2 Nos. (1working+1 standby) comprising of chlorine solution-feeding unit, control panel, pipings, sensor for detecting leakages, booster pump, sprinkler system, injector module to suit the capacity of the chlorinator sprinkler system etc. complete in all respect as per the specification. | BI01010001010000000000000515BI0100001581 | ||
471 | 11.59 | Civil Work & other miscellanious work | BI01010001010000000000000515BI0100001582 | 50 | Sqm |
472 | 11.6 | Chlorinators 2 kg/Hr Capacity) | BI01010001010000000000000515BI0100001583 | 2 | No |
473 | 11.61 | Chlorine Tonner 900 Kg | BI01010001010000000000000515BI0100001584 | 2 | No |
474 | 11.62 | Instrumentation | BI01010001010000000000000515BI0100001585 | ||
475 | 11.63 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001586 | ||
476 | 11.64 | D/F Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001587 | ||
477 | 11.65 | 200 mm dia | BI01010001010000000000000515BI0100001588 | 3 | No |
478 | 11.66 | 250 mm dia | BI01010001010000000000000515BI0100001589 | 1 | No |
479 | 11.67 | 300 mm dia | BI01010001010000000000000515BI0100001590 | 1 | No |
480 | 11.68 | 450 mm dia | BI01010001010000000000000515BI0100001591 | 1 | No |
481 | 11.69 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001592 | ||
482 | 11.7 | 200 mm dia | BI01010001010000000000000515BI0100001593 | 9 | No |
483 | 11.71 | 250 mm dia | BI01010001010000000000000515BI0100001594 | 3 | No |
484 | 11.72 | 300 mm dia | BI01010001010000000000000515BI0100001595 | 3 | No |
485 | 11.73 | 450 mm dia | BI01010001010000000000000515BI0100001596 | 3 | No |
486 | 11.74 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001597 | ||
487 | 11.75 | 200 mm dia | BI01010001010000000000000515BI0100001598 | 6 | No |
488 | 11.76 | 250 mm dia | BI01010001010000000000000515BI0100001599 | 2 | No |
489 | 11.77 | 300 mm dia | BI01010001010000000000000515BI0100001600 | 2 | No |
490 | 11.78 | 450 mm dia | BI01010001010000000000000515BI0100001601 | 2 | No |
491 | 11.79 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001602 | 1 | No |
492 | 11.8 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001603 | 1 | Lot |
493 | 12 | Intermediate Pumping Station at Hindoli | BI01010001010000000000000515BI0100001604 | ||
494 | 12.01 | Civil work | BI01010001010000000000000515BI0100001605 | ||
495 | 12.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001606 | ||
496 | 12.03 | At Hindoli Head work For Installation of 3W+3S Pumps & 2 pumps for future).Pump house shall be constructed over RCC CWR. | BI01010001010000000000000515BI0100001607 | 200 | Sqm |
497 | 12.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001608 | ||
498 | 12.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001609 | ||
499 | 12.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001610 | ||
500 | 12.07 | IPS-2 (Hindoli) to JN-29,JN-31,P-SR PECH KI BAWRI (HCL-47),EXT-SR PECH KI BAWRI (HCL-47),JN-32,P-SR PAPRALA (HCL-11) route 41 LPS / 120 m head/97 KW (1W+1S) | BI01010001010000000000000515BI0100001611 | 2 | each |
501 | 12.08 | IPS-2 (Hindoli) to JN-34,EXT-CWR HINDOLI (HCL-19),JN-35,JN-36,P-SR ROSANDA (HCL-14) route 45 LPS / 145 m head/128 KW (1W+1S) | BI01010001010000000000000515BI0100001612 | 2 | each |
502 | 12.09 | IPS-2 (Hindoli) to JN-38,JN-39,P-SR GANESHGANJ (HCL-21) route 26 LPS / 105 m head/62 KW (1W+1S) | BI01010001010000000000000515BI0100001613 | 2 | each |
503 | 12.1 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-5mm thk | BI01010001010000000000000515BI0100001614 | ||
504 | 12.11 | 150 mm dia 5mm thk | BI01010001010000000000000515BI0100001615 | 10 | Meter |
505 | 12.12 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001616 | 20 | Meter |
506 | 12.13 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. -5mm thk | BI01010001010000000000000515BI0100001617 | ||
507 | 12.14 | 150 mm dia 5mm thk | BI01010001010000000000000515BI0100001618 | 35 | Meter |
508 | 12.15 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001619 | 70 | Meter |
509 | 12.16 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001620 | ||
510 | 12.17 | 150 mm dia | BI01010001010000000000000515BI0100001621 | 3 | No |
511 | 12.18 | 200 mm dia | BI01010001010000000000000515BI0100001622 | 6 | No |
512 | 12.19 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001623 | ||
513 | 12.2 | 150 mm dia | BI01010001010000000000000515BI0100001624 | 3 | No |
514 | 12.21 | 200 mm dia | BI01010001010000000000000515BI0100001625 | 6 | No |
515 | 12.22 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001626 | ||
516 | 12.23 | 150 mm dia | BI01010001010000000000000515BI0100001627 | 2 | No |
517 | 12.24 | 200 mm dia | BI01010001010000000000000515BI0100001628 | 4 | No |
518 | 12.25 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001629 | ||
519 | 12.26 | 150 mm dia | BI01010001010000000000000515BI0100001630 | 2 | No |
520 | 12.27 | 200 mm dia | BI01010001010000000000000515BI0100001631 | 4 | No |
521 | 12.28 | DI Kinetic Air Valves of 100 mm diameter with isolating Sluice Valve of 100 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001632 | 3 | No |
522 | 12.29 | EOT of minimum 2 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001633 | 1 | No |
523 | 12.3 | Glycerine filled pressure gauges | BI01010001010000000000000515BI0100001634 | 9 | No |
524 | 12.31 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001635 | ||
525 | 12.32 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001636 | 574 | KW |
526 | 12.33 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . | BI01010001010000000000000515BI0100001637 | 574 | KW |
527 | 12.34 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001638 | 574 | KW |
528 | 12.35 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001639 | ||
529 | 12.36 | For LT Panet & motors | BI01010001010000000000000515BI0100001640 | 6 | No |
530 | 12.37 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001641 | ||
531 | 12.38 | Inside Pump House | BI01010001010000000000000515BI0100001642 | 6 | No |
532 | 12.39 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001643 | 8 | each |
533 | 12.4 | Construction of shed and providing Post chlorination System comprising of Supply & installation of chlorine tonners (2 nos. @ 900 kg) with vaccum chlorinator 2 Nos. (1working+1 standby) comprising of chlorine solution-feeding unit, control panel, pipings, sensor for detecting leakages, booster pump, sprinkler system, injector module to suit the capacity of the chlorinator sprinkler system etc. complete in all respect as per the specification. | BI01010001010000000000000515BI0100001644 | ||
534 | 12.41 | Civil Work & other miscellanious work | BI01010001010000000000000515BI0100001645 | 50 | Sqm |
535 | 12.42 | Chlorinators 2 kg/Hr Capacity) | BI01010001010000000000000515BI0100001646 | 2 | No |
536 | 12.43 | Chlorine Tonner 900 Kg | BI01010001010000000000000515BI0100001647 | 2 | No |
537 | 12.44 | Instrumentation | BI01010001010000000000000515BI0100001648 | ||
538 | 12.45 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001649 | ||
539 | 12.46 | Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001650 | ||
540 | 12.47 | 150 mm dia | BI01010001010000000000000515BI0100001651 | 1 | No |
541 | 12.48 | 200 mm dia | BI01010001010000000000000515BI0100001652 | 2 | No |
542 | 12.49 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001653 | ||
543 | 12.5 | 150 mm dia | BI01010001010000000000000515BI0100001654 | 2 | No |
544 | 12.51 | 200 mm dia | BI01010001010000000000000515BI0100001655 | 6 | No |
545 | 12.52 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001656 | ||
546 | 12.53 | 150 mm dia | BI01010001010000000000000515BI0100001657 | 1 | No |
547 | 12.54 | 200 mm dia | BI01010001010000000000000515BI0100001658 | 4 | No |
548 | 12.55 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001659 | 1 | No |
549 | 12.56 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001660 | 1 | Lot |
550 | 13 | Intermediate Pumping Station at Dablana | BI01010001010000000000000515BI0100001661 | ||
551 | 13.01 | Civil Works | BI01010001010000000000000515BI0100001662 | ||
552 | 13.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001663 | ||
553 | 13.03 | At Dablana Head work For Installation of 5W+5S Pumps & 2 pumps for future).Pump house shall be constructed over RCC CWR. | BI01010001010000000000000515BI0100001664 | 270 | Sqm |
554 | 13.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001665 | ||
555 | 13.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001666 | ||
556 | 13.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001667 | ||
557 | 13.07 | IPS-3 (DABLANA/BHAWANIPURA) to IPS-4 Bansi route 94 LPS / 35 m head/62 KW (2W+2S) | BI01010001010000000000000515BI0100001668 | 4 | each |
558 | 13.08 | IPS-3 (DABLANA/BHAWANIPURA) to JN-40,P-SR BHAWANIPURA (HCL-33) route 21 LPS / 65 m head/31 KW (1W+1S) | BI01010001010000000000000515BI0100001669 | 2 | each |
559 | 13.09 | IPS-3 (DABLANA/BHAWANIPURA) to JN-42,JN-43,P-SR RUNEEJA (HCL-27) route 28 LPS / 125 m head/79 KW (1W+1S) | BI01010001010000000000000515BI0100001670 | 2 | each |
560 | 13.1 | IPS-3 (DABLANA/BHAWANIPURA) to JN-45,JN-47,P-SR ROSNDA (HCL-29),JN-49,P-SR SORAN (HCL-30) route 38 LPS / 115 m head/86 KW (1W+1S) | BI01010001010000000000000515BI0100001671 | 2 | each |
561 | 13.11 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-5mm thk | BI01010001010000000000000515BI0100001672 | ||
562 | 13.12 | 150 mm dia 5mm thk | BI01010001010000000000000515BI0100001673 | 20 | Meter |
563 | 13.13 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001674 | 10 | Meter |
564 | 13.14 | 300 mm dia 5mm thk | BI01010001010000000000000515BI0100001675 | 20 | Meter |
565 | 13.15 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. | BI01010001010000000000000515BI0100001676 | ||
566 | 13.16 | 150 mm dia 5mm thk | BI01010001010000000000000515BI0100001677 | 80 | Meter |
567 | 13.17 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001678 | 40 | Meter |
568 | 13.18 | 400 mm dia 6mm thk | BI01010001010000000000000515BI0100001679 | 40 | Meter |
569 | 13.19 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001680 | ||
570 | 13.2 | 150 mm dia | BI01010001010000000000000515BI0100001681 | 6 | No |
571 | 13.21 | 200 mm dia | BI01010001010000000000000515BI0100001682 | 3 | No |
572 | 13.22 | 300 mm dia | BI01010001010000000000000515BI0100001683 | 4 | No |
573 | 13.23 | 400 mm dia | BI01010001010000000000000515BI0100001684 | 1 | No |
574 | 13.24 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001685 | ||
575 | 13.25 | 150 mm dia | BI01010001010000000000000515BI0100001686 | 6 | No |
576 | 13.26 | 200 mm dia | BI01010001010000000000000515BI0100001687 | 3 | No |
577 | 13.27 | 300 mm dia | BI01010001010000000000000515BI0100001688 | 4 | No |
578 | 13.28 | 400 mm dia | BI01010001010000000000000515BI0100001689 | 1 | No |
579 | 13.29 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001690 | ||
580 | 13.3 | 150 mm dia | BI01010001010000000000000515BI0100001691 | 4 | No |
581 | 13.31 | 200 mm dia | BI01010001010000000000000515BI0100001692 | 2 | No |
582 | 13.32 | 300 mm dia | BI01010001010000000000000515BI0100001693 | 4 | No |
583 | 13.33 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001694 | ||
584 | 13.34 | 150 mm dia | BI01010001010000000000000515BI0100001695 | 4 | No |
585 | 13.35 | 200 mm dia | BI01010001010000000000000515BI0100001696 | 2 | No |
586 | 13.36 | 300 mm dia | BI01010001010000000000000515BI0100001697 | 4 | No |
587 | 13.37 | DI Kinetic Air Valves of 100 mm diameter with isolating Sluice Valve of 100 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001698 | 3 | No |
588 | 13.38 | DI Kinetic Air Valves of 150 mm diameter with isolating Sluice Valve of 150 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001699 | 1 | No |
589 | 13.39 | EOT of minimum 2 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001700 | 1 | No |
590 | 13.4 | Glycerine filled pressure gauges | BI01010001010000000000000515BI0100001701 | 14 | No |
591 | 13.41 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001702 | ||
592 | 13.42 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001703 | 640 | KW |
593 | 13.43 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . | BI01010001010000000000000515BI0100001704 | 640 | KW |
594 | 13.44 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001705 | 640 | KW |
595 | 13.45 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001706 | ||
596 | 13.46 | For LT Panet & motors | BI01010001010000000000000515BI0100001707 | 8 | No |
597 | 13.47 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001708 | ||
598 | 13.48 | Inside Pump House | BI01010001010000000000000515BI0100001709 | 6 | No |
599 | 13.49 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001710 | 10 | each |
600 | 13.5 | Construction of shed and providing Post chlorination System comprising of Supply & installation of chlorine tonners (2 nos. @ 900 kg) with vaccum chlorinator 2 Nos. (1working+1 standby) comprising of chlorine solution-feeding unit, control panel, pipings, sensor for detecting leakages, booster pump, sprinkler system, injector module to suit the capacity of the chlorinator sprinkler system etc. complete in all respect as per the specification. | BI01010001010000000000000515BI0100001711 | ||
601 | 13.51 | Civil Work & other miscellanious work | BI01010001010000000000000515BI0100001712 | 50 | Sqm |
602 | 13.52 | Chlorinators 2 kg/Hr Capacity) | BI01010001010000000000000515BI0100001713 | 2 | No |
603 | 13.53 | Chlorine Tonner 900 Kg | BI01010001010000000000000515BI0100001714 | 2 | No |
604 | 13.54 | Instrumentation | BI01010001010000000000000515BI0100001715 | ||
605 | 13.55 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001716 | ||
606 | 13.56 | Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001717 | ||
607 | 13.57 | 150 mm dia | BI01010001010000000000000515BI0100001718 | 2 | No |
608 | 13.58 | 200 mm dia | BI01010001010000000000000515BI0100001719 | 1 | No |
609 | 13.59 | 400 mm dia | BI01010001010000000000000515BI0100001720 | 1 | No |
610 | 13.6 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001721 | ||
611 | 13.61 | 150 mm dia | BI01010001010000000000000515BI0100001722 | 4 | No |
612 | 13.62 | 200 mm dia | BI01010001010000000000000515BI0100001723 | 3 | No |
613 | 13.63 | 400 mm dia | BI01010001010000000000000515BI0100001724 | 3 | No |
614 | 13.64 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001725 | ||
615 | 13.65 | 150 mm dia | BI01010001010000000000000515BI0100001726 | 2 | No |
616 | 13.66 | 200 mm dia | BI01010001010000000000000515BI0100001727 | 2 | No |
617 | 13.67 | 400 mm dia | BI01010001010000000000000515BI0100001728 | 2 | No |
618 | 13.68 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001729 | 1 | No |
619 | 13.69 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001730 | 1 | Lot |
620 | 14 | Intermediate Pumping Station at Bansi | BI01010001010000000000000515BI0100001731 | ||
621 | 14.01 | Civil Works | BI01010001010000000000000515BI0100001732 | ||
622 | 14.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001733 | ||
623 | 14.03 | At Bansi Head work for Installation of 5W+5S Pumps & 2 pumps for future).Pump house shall be constructed over RCC CWR. | BI01010001010000000000000515BI0100001734 | 270 | Sqm |
624 | 14.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001735 | ||
625 | 14.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001736 | ||
626 | 14.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001737 | ||
627 | 14.07 | IPS-4 (Bansi) to IPS-6 Dei route 38 LPS / 45 m head/35 KW (1W+1S) | BI01010001010000000000000515BI0100001738 | 2 | each |
628 | 14.08 | IPS-4 (Bansi) to IPS-5 Nainwa route 97 LPS / 65 m head/97 KW (1W+1S) | BI01010001010000000000000515BI0100001739 | 2 | each |
629 | 14.09 | IPS-4 (Bansi) to JUN-50,JUN-51,P-SR DODI (NCL-13),P-SR DOKOON (NCL-7) route 31 LPS / 80 m head/51 KW (1W+1S) | BI01010001010000000000000515BI0100001740 | 2 | each |
630 | 14.1 | IPS-4 (Bansi) to JUN-52,JUN-53,P-SR SADERA (NCL-10) route 21 LPS / 75 m head/ 36 KW (1W+1S) | BI01010001010000000000000515BI0100001741 | 2 | each |
631 | 14.11 | IPS-4 (Bansi) to JUN-55,JUN-56,JUN-57,JUN-58 route 23 LPS /130 m head/ 68 KW (1W+1S) | BI01010001010000000000000515BI0100001742 | 2 | each |
632 | 14.12 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-5mm thk | BI01010001010000000000000515BI0100001743 | ||
633 | 14.13 | 150 mm dia 5mm thk | BI01010001010000000000000515BI0100001744 | 20 | Meter |
634 | 14.14 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001745 | 20 | Meter |
635 | 14.15 | 300 mm dia 5mm thk | BI01010001010000000000000515BI0100001746 | 10 | Meter |
636 | 14.16 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. -5mm thk | BI01010001010000000000000515BI0100001747 | ||
637 | 14.17 | 150 mm dia 5mm thk | BI01010001010000000000000515BI0100001748 | 90 | Meter |
638 | 14.18 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001749 | 90 | Meter |
639 | 14.19 | 300 mm dia 5mm thk | BI01010001010000000000000515BI0100001750 | 45 | Meter |
640 | 14.2 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001751 | ||
641 | 14.21 | 150 mm dia | BI01010001010000000000000515BI0100001752 | 6 | No |
642 | 14.22 | 200 mm dia | BI01010001010000000000000515BI0100001753 | 6 | No |
643 | 14.23 | 300 mm dia | BI01010001010000000000000515BI0100001754 | 3 | No |
644 | 14.24 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001755 | ||
645 | 14.25 | 150 mm dia | BI01010001010000000000000515BI0100001756 | 6 | No |
646 | 14.26 | 200 mm dia | BI01010001010000000000000515BI0100001757 | 6 | No |
647 | 14.27 | 300 mm dia | BI01010001010000000000000515BI0100001758 | 3 | No |
648 | 14.28 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001759 | ||
649 | 14.29 | 150 mm dia | BI01010001010000000000000515BI0100001760 | 4 | No |
650 | 14.3 | 200 mm dia | BI01010001010000000000000515BI0100001761 | 4 | No |
651 | 14.31 | 300 mm dia | BI01010001010000000000000515BI0100001762 | 2 | No |
652 | 14.32 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001763 | ||
653 | 14.33 | 150 mm dia | BI01010001010000000000000515BI0100001764 | 4 | No |
654 | 14.34 | 200 mm dia | BI01010001010000000000000515BI0100001765 | 4 | No |
655 | 14.35 | 300 mm dia | BI01010001010000000000000515BI0100001766 | 2 | No |
656 | 14.36 | DI Kinetic Air Valves of 100 mm diameter with isolating Sluice Valve of 100 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001767 | 5 | No |
657 | 14.37 | EOT of minimum 2 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001768 | 1 | No |
658 | 14.38 | Glycerine filled pressure gauges (0-10 kg) | BI01010001010000000000000515BI0100001769 | 15 | No |
659 | 14.39 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001770 | ||
660 | 14.4 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001771 | 574 | KW |
661 | 14.41 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . | BI01010001010000000000000515BI0100001772 | 574 | KW |
662 | 14.42 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001773 | 574 | KW |
663 | 14.43 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001774 | ||
664 | 14.44 | For LT Panet & motors | BI01010001010000000000000515BI0100001775 | 10 | No |
665 | 14.45 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001776 | ||
666 | 14.46 | Inside Pump House | BI01010001010000000000000515BI0100001777 | 6 | No |
667 | 14.47 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001778 | 10 | each |
668 | 14.48 | Construction of shed and providing Post chlorination System comprising of Supply & installation of chlorine tonners (2 nos. @ 900 kg) with vaccum chlorinator 2 Nos. (1working+1 standby) comprising of chlorine solution-feeding unit, control panel, pipings, sensor for detecting leakages, booster pump, sprinkler system, injector module to suit the capacity of the chlorinator sprinkler system etc. complete in all respect as per the specification. | BI01010001010000000000000515BI0100001779 | ||
669 | 14.49 | Civil Work & other miscellanious work | BI01010001010000000000000515BI0100001780 | 50 | Sqm |
670 | 14.5 | Chlorinators 2 kg/Hr Capacity) | BI01010001010000000000000515BI0100001781 | 2 | No |
671 | 14.51 | Chlorine Tonner 900 Kg | BI01010001010000000000000515BI0100001782 | 2 | No |
672 | 14.52 | Instrumentation | BI01010001010000000000000515BI0100001783 | ||
673 | 14.53 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001784 | ||
674 | 14.54 | D/F Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001785 | ||
675 | 14.55 | 150 mm dia | BI01010001010000000000000515BI0100001786 | 2 | No |
676 | 14.56 | 200 mm dia | BI01010001010000000000000515BI0100001787 | 2 | No |
677 | 14.57 | 300 mm dia | BI01010001010000000000000515BI0100001788 | 1 | No |
678 | 14.58 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001789 | ||
679 | 14.59 | 150 mm dia | BI01010001010000000000000515BI0100001790 | 4 | No |
680 | 14.6 | 200 mm dia | BI01010001010000000000000515BI0100001791 | 6 | No |
681 | 14.61 | 300 mm dia | BI01010001010000000000000515BI0100001792 | 3 | No |
682 | 14.62 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001793 | ||
683 | 14.63 | 150 mm dia | BI01010001010000000000000515BI0100001794 | 2 | No |
684 | 14.64 | 200 mm dia | BI01010001010000000000000515BI0100001795 | 4 | No |
685 | 14.65 | 300 mm dia | BI01010001010000000000000515BI0100001796 | 2 | No |
686 | 14.66 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001797 | 1 | No |
687 | 14.67 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001798 | 1 | Lot |
688 | 15 | Intermediate Pumping Station at Nainwa | BI01010001010000000000000515BI0100001799 | ||
689 | 15.01 | Civil Works | BI01010001010000000000000515BI0100001800 | ||
690 | 15.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001801 | ||
691 | 15.03 | At Nainwa Head work for Installation of 4W+4S Pumps & 2 pumps for future).Pump house shall be constructed over RCC CWR. | BI01010001010000000000000515BI0100001802 | 250 | Sqm |
692 | 15.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001803 | ||
693 | 15.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001804 | ||
694 | 15.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001805 | ||
695 | 15.07 | IPS-5 (NAINWA) to JUN-59,JUN-60,P-SR SUVANEYA (NCL-18) route 18 LPS / 100 m head/40 KW (1W+1S) | BI01010001010000000000000515BI0100001806 | 2 | Each |
696 | 15.08 | IPS-5 (NAINWA) to JUN-61,EXT-CWR NAINWA,P-SR NAINWA (Z-4) route 69 LPS / 55 m head/71 KW (1W+1S) | BI01010001010000000000000515BI0100001807 | 2 | Each |
697 | 15.09 | IPS-5 (NAINWA) to JUN-62,P-SR KHERUNA (NCL-15) route 20 LPS / 80 m head/36 KW (1W+1S) | BI01010001010000000000000515BI0100001808 | 2 | Each |
698 | 15.1 | IPS-5 (NAINWA) to JUN-64,P-SR KORMA (NCL-20),JUN-65,P-SR KHORI (NCL-25) route 28 LPS / 125 m head/79 KW (1W+1S) | BI01010001010000000000000515BI0100001809 | 2 | Each |
699 | 15.11 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.-5mm thk | BI01010001010000000000000515BI0100001810 | ||
700 | 15.12 | 125 mm dia | BI01010001010000000000000515BI0100001811 | 20 | Meter |
701 | 15.13 | 200 mm dia | BI01010001010000000000000515BI0100001812 | 10 | Meter |
702 | 15.14 | 250 mm dia | BI01010001010000000000000515BI0100001813 | 10 | Meter |
703 | 15.15 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. -5mm thk | BI01010001010000000000000515BI0100001814 | ||
704 | 15.16 | 125 mm dia | BI01010001010000000000000515BI0100001815 | 80 | Meter |
705 | 15.17 | 200 mm dia | BI01010001010000000000000515BI0100001816 | 40 | Meter |
706 | 15.18 | 250 mm dia | BI01010001010000000000000515BI0100001817 | 40 | Meter |
707 | 15.19 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001818 | ||
708 | 15.2 | 125 mm dia | BI01010001010000000000000515BI0100001819 | 6 | No |
709 | 15.21 | 200 mm dia | BI01010001010000000000000515BI0100001820 | 3 | No |
710 | 15.22 | 250 mm dia | BI01010001010000000000000515BI0100001821 | 3 | No |
711 | 15.23 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001822 | ||
712 | 15.24 | 125 mm dia | BI01010001010000000000000515BI0100001823 | 6 | No |
713 | 15.25 | 200 mm dia | BI01010001010000000000000515BI0100001824 | 3 | No |
714 | 15.26 | 250 mm dia | BI01010001010000000000000515BI0100001825 | 3 | No |
715 | 15.27 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001826 | ||
716 | 15.28 | 125 mm dia | BI01010001010000000000000515BI0100001827 | 4 | No |
717 | 15.29 | 200 mm dia | BI01010001010000000000000515BI0100001828 | 2 | No |
718 | 15.3 | 250 mm dia | BI01010001010000000000000515BI0100001829 | 2 | No |
719 | 15.31 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001830 | ||
720 | 15.32 | 125 mm dia | BI01010001010000000000000515BI0100001831 | 4 | No |
721 | 15.33 | 200 mm dia | BI01010001010000000000000515BI0100001832 | 2 | No |
722 | 15.34 | 250 mm dia | BI01010001010000000000000515BI0100001833 | 2 | No |
723 | 15.35 | DI Kinetic Air Valves of 100 mm diameter with isolating Sluice Valve of 100 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001834 | 4 | No |
724 | 15.36 | EOT of minimum 2 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001835 | 1 | No |
725 | 15.37 | Glycerine filled pressure gauges (0-10 kg) | BI01010001010000000000000515BI0100001836 | 12 | No |
726 | 15.38 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001837 | ||
727 | 15.39 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001838 | 452 | KW |
728 | 15.4 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . | BI01010001010000000000000515BI0100001839 | 452 | KW |
729 | 15.41 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001840 | 452 | KW |
730 | 15.42 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001841 | ||
731 | 15.43 | For LT Panet & motors | BI01010001010000000000000515BI0100001842 | 8 | No |
732 | 15.44 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001843 | ||
733 | 15.45 | Inside Pump House | BI01010001010000000000000515BI0100001844 | 6 | No |
734 | 15.46 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001845 | 8 | each |
735 | 15.47 | Construction of shed and providing Post chlorination System comprising of Supply & installation of chlorine tonners (2 nos. @ 900 kg) with vaccum chlorinator 2 Nos. (1working+1 standby) comprising of chlorine solution-feeding unit, control panel, pipings, sensor for detecting leakages, booster pump, sprinkler system, injector module to suit the capacity of the chlorinator sprinkler system etc. complete in all respect as per the specification. | BI01010001010000000000000515BI0100001846 | ||
736 | 15.48 | Civil Work & other miscellanious work | BI01010001010000000000000515BI0100001847 | 50 | Sqm |
737 | 15.49 | Chlorinators 2 kg/Hr Capacity) | BI01010001010000000000000515BI0100001848 | 2 | No |
738 | 15.5 | Chlorine Tonner 900 Kg | BI01010001010000000000000515BI0100001849 | 2 | No |
739 | 15.51 | Instrumentation | BI01010001010000000000000515BI0100001850 | ||
740 | 15.52 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001851 | ||
741 | 15.53 | Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001852 | ||
742 | 15.54 | 125 mm dia | BI01010001010000000000000515BI0100001853 | 2 | No |
743 | 15.55 | 200 mm dia | BI01010001010000000000000515BI0100001854 | 1 | No |
744 | 15.56 | 250 mm dia | BI01010001010000000000000515BI0100001855 | 1 | No |
745 | 15.57 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001856 | ||
746 | 15.58 | 125 mm dia | BI01010001010000000000000515BI0100001857 | 4 | No |
747 | 15.59 | 200 mm dia | BI01010001010000000000000515BI0100001858 | 3 | No |
748 | 15.6 | 250 mm dia | BI01010001010000000000000515BI0100001859 | 3 | No |
749 | 15.61 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001860 | ||
750 | 15.62 | 125 mm dia | BI01010001010000000000000515BI0100001861 | 2 | No |
751 | 15.63 | 200 mm dia | BI01010001010000000000000515BI0100001862 | 2 | No |
752 | 15.64 | 250 mm dia | BI01010001010000000000000515BI0100001863 | 2 | No |
753 | 15.65 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001864 | 1 | No |
754 | 15.66 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001865 | 1 | Lot |
755 | 16 | Intermediate Pumping Station at Dei | BI01010001010000000000000515BI0100001866 | ||
756 | 16.01 | Civil Works | BI01010001010000000000000515BI0100001867 | ||
757 | 16.02 | Civil work such as construction of pump House. | BI01010001010000000000000515BI0100001868 | ||
758 | 16.03 | At Dei Head work for Installation of 2W+2S Pumps & 2 pumps for future).Pump house shall be constructed over RCC CWR. | BI01010001010000000000000515BI0100001869 | 150 | Sqm |
759 | 16.04 | Mechanical Equipment & Accessories | BI01010001010000000000000515BI0100001870 | ||
760 | 16.05 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001871 | ||
761 | 16.06 | Centrifugal Submersible pumps & motor all other accessories of following duty conditions | BI01010001010000000000000515BI0100001872 | ||
762 | 16.07 | IPS-6 (Dei) to JUN-66,JUN-67,P-SR MODSA (NCL-05) route 14 LPS/ 135 m head/43 KW (1W+1S) | BI01010001010000000000000515BI0100001873 | 2 | each |
763 | 16.08 | IPS-6 (Dei) to JUN-68,JUN-69,JUN-70,P-SR GUDHA DEVJI (NCL-01) route 39 LPS / 130 m head/99 KW (1W+1S) | BI01010001010000000000000515BI0100001874 | 2 | each |
764 | 16.09 | MS discharge pipes with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc.- | BI01010001010000000000000515BI0100001875 | ||
765 | 16.1 | 125 mm dia 5mm thk | BI01010001010000000000000515BI0100001876 | 10 | Meter |
766 | 16.11 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001877 | 10 | Meter |
767 | 16.12 | MS common Delivery Pipes (manifold) with all fittings such as flanges; bends; tees; and other specials; nut & bolts; gasket etc. - | BI01010001010000000000000515BI0100001878 | ||
768 | 16.13 | 125 mm dia 5mm thk | BI01010001010000000000000515BI0100001879 | 30 | Meter |
769 | 16.14 | 200 mm dia 5mm thk | BI01010001010000000000000515BI0100001880 | 30 | Meter |
770 | 16.15 | Electrically operated DI resilient seated Sluice Valves of on individual & common delivery piping of following sizes (PN-1.6) | BI01010001010000000000000515BI0100001881 | ||
771 | 16.16 | 125 mm dia | BI01010001010000000000000515BI0100001882 | 3 | No |
772 | 16.17 | 200 mm dia | BI01010001010000000000000515BI0100001883 | 3 | No |
773 | 16.18 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001884 | ||
774 | 16.19 | 125 mm dia | BI01010001010000000000000515BI0100001885 | 3 | No |
775 | 16.2 | 200 mm dia | BI01010001010000000000000515BI0100001886 | 3 | No |
776 | 16.21 | Electrically operated D/F DI resilient seated Butterfly Valves on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001887 | ||
777 | 16.22 | 125 mm dia | BI01010001010000000000000515BI0100001888 | 2 | No |
778 | 16.23 | 200 mm dia | BI01010001010000000000000515BI0100001889 | 2 | No |
779 | 16.24 | Dual Plate type DI resilient seated Check valve of following sizes on individual & common delivery piping of following sizes (PN-1.6) Category A | BI01010001010000000000000515BI0100001890 | ||
780 | 16.25 | 125 mm dia | BI01010001010000000000000515BI0100001891 | 2 | No |
781 | 16.26 | 200 mm dia | BI01010001010000000000000515BI0100001892 | 2 | No |
782 | 16.27 | DI Kinetic Air Valves of 100 mm diameter with isolating Sluice Valve of 100 mm size (PN-1.6) Temper Proof | BI01010001010000000000000515BI0100001893 | 2 | No |
783 | 16.28 | EOT of minimum 2 ton capacity or as per design with all accessories for lateral & transverse movement | BI01010001010000000000000515BI0100001894 | 1 | No |
784 | 16.29 | Glycerine filled pressure gauges (0-10 kg) | BI01010001010000000000000515BI0100001895 | 6 | No |
785 | 16.3 | Providing, installation, testing, trial run and commissioning of the following, as per the specifications | BI01010001010000000000000515BI0100001896 | ||
786 | 16.31 | Providing, installation, testing and commissioning of soft starters, for each pump-set, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001897 | 284 | KW |
787 | 16.32 | Providing, installation, testing and commissioning of LT MCC with panels housing motor starters relays, MCB/MCCBs, bus-bar for all pump sets including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications . | BI01010001010000000000000515BI0100001898 | 284 | KW |
788 | 16.33 | Providing, installation, testing and commissioning of capacitor control panels, housing power factor control system panel/capacitors (APFC Panel), other accessaries including all internal cabling and cable/bus-bar from switchyard, up to panels, etc, complete in all respect as per the scope of work & specifications. | BI01010001010000000000000515BI0100001899 | 284 | KW |
789 | 16.34 | Earthing system complete for LT equipments | BI01010001010000000000000515BI0100001900 | ||
790 | 16.35 | For LT Panet & motors | BI01010001010000000000000515BI0100001901 | 4 | No |
791 | 16.36 | Exhaust Fans, of pump house and other ventilating arrangements like roof entrance etc | BI01010001010000000000000515BI0100001902 | ||
792 | 16.37 | Inside Pump House | BI01010001010000000000000515BI0100001903 | 6 | No |
793 | 16.38 | IP-65 protected LED street light luminaries for pump house building:LED street light fixture 30-40 Watt | BI01010001010000000000000515BI0100001904 | 6 | each |
794 | 16.39 | Construction of shed and providing Post chlorination System comprising of Supply & installation of chlorine tonners (2 nos. @ 900 kg) with vaccum chlorinator 2 Nos. (1working+1 standby) comprising of chlorine solution-feeding unit, control panel, pipings, sensor for detecting leakages, booster pump, sprinkler system, injector module to suit the capacity of the chlorinator sprinkler system etc. complete in all respect as per the specification. | BI01010001010000000000000515BI0100001905 | ||
795 | 16.4 | Civil Work & other miscellanious work | BI01010001010000000000000515BI0100001906 | 50 | Sqm |
796 | 16.41 | Chlorinators 2 kg/Hr Capacity) | BI01010001010000000000000515BI0100001907 | 2 | No |
797 | 16.42 | Chlorine Tonner 900 Kg | BI01010001010000000000000515BI0100001908 | 2 | No |
798 | 16.43 | Instrumentation | BI01010001010000000000000515BI0100001909 | ||
799 | 16.44 | Providing, installation, testing, trial run and commissioning of the following, as per specifications | BI01010001010000000000000515BI0100001910 | ||
800 | 16.45 | Full Bore Electro magnetic Flow meter with suitable size by pass arrangement and associated pipes and specials etc, as per scope of work for following headworks | BI01010001010000000000000515BI0100001911 | ||
801 | 16.46 | 125 mm dia | BI01010001010000000000000515BI0100001912 | 1 | No |
802 | 16.47 | 200 mm dia | BI01010001010000000000000515BI0100001913 | 1 | No |
803 | 16.48 | Manually Operated Resilient Seated DI D/F Sluice Valves for flow meter arrangement : (PN-1.6) | BI01010001010000000000000515BI0100001914 | ||
804 | 16.49 | 125 mm dia | BI01010001010000000000000515BI0100001915 | 2 | No |
805 | 16.5 | 200 mm dia | BI01010001010000000000000515BI0100001916 | 3 | No |
806 | 16.51 | Stain less steel Expansion bellows of following sizes on individual & common delivery piping of following sizes | BI01010001010000000000000515BI0100001917 | ||
807 | 16.52 | 125 mm dia | BI01010001010000000000000515BI0100001918 | 1 | No |
808 | 16.53 | 200 mm dia | BI01010001010000000000000515BI0100001919 | 2 | No |
809 | 16.54 | Construction of Flow meter chamber | BI01010001010000000000000515BI0100001920 | 1 | No |
810 | 16.55 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001921 | 1 | Lot |
811 | 17 | Over Head Service Resevoir | BI01010001010000000000000515BI0100001922 | ||
812 | 17.01 | Construction of RCC INTZE type Over Head Service Resevoir of following capacity and staging consisting of excavation in all type of strata , RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff , plinth protection , all labour and material charge including providing and fixing of accessories such as ladder , manhole frame and covers , water level indicator ( float type ) ventilator with SS screen , lightening arrestor , float valves , puddle collar , G.I. pipe railing around walk way and top dome , providing RCC staircase from 4.5 mtr height of ground level to top level , chambers for all valves , providing and applying three coats of cement paint to the external surface of container , food grade epoxy paint to internal surface and giving satisfactory hydraulic test and water tightnees test as per I.S. code , etc. complete in all respect ae per design data , criteria , obligatory requirements and detailed specifications , scope of work and GA drawing. The job includes painting the name of the scheme and other details on the reservoir , providing aluminium portable ladder suitable to reach at height of 4.5 Mtr and any other work related to structure as per the directions of Engineer -in-charge , Technical Specification and Scope of work. | BI01010001010000000000000515BI0100001923 | ||
813 | 17.02 | ESR Details | BI01010001010000000000000515BI0100001924 | ||
814 | 17.03 | 100 kl at 20 Mtr stagging (100 KL X 6 nos) | BI01010001010000000000000515BI0100001925 | 600 | KL |
815 | 17.04 | 100 kl at 22 Mtr stagging (100 KL X 1 nos) | BI01010001010000000000000515BI0100001926 | 100 | KL |
816 | 17.05 | 150 kl at 20 Mtr stagging (150 KL X 4 nos) | BI01010001010000000000000515BI0100001927 | 600 | KL |
817 | 17.06 | 150 kl at 22 Mtr stagging (150 KL X 1 no) | BI01010001010000000000000515BI0100001928 | 150 | KL |
818 | 17.07 | 200 k lat 20 Mtr stagging (200 KL X 5 nos) | BI01010001010000000000000515BI0100001929 | 1000 | KL |
819 | 17.08 | 200 kl at 22 Mtr stagging (200 KL X 3 nos) | BI01010001010000000000000515BI0100001930 | 600 | KL |
820 | 17.09 | 200 kl at 25 Mtr stagging (200 KL X 3 nos) | BI01010001010000000000000515BI0100001931 | 600 | KL |
821 | 17.1 | 250 kl at 20 Mtr stagging (250 KL X 9 nos) | BI01010001010000000000000515BI0100001932 | 2250 | KL |
822 | 17.11 | 250 kl at 22 Mtr stagging (250 KL X 4 nos) | BI01010001010000000000000515BI0100001933 | 1000 | KL |
823 | 17.12 | 250 kl at 25 Mtr stagging (250 KL X 2 nos) | BI01010001010000000000000515BI0100001934 | 500 | KL |
824 | 17.13 | 300 kl at 20 Mtr stagging (300 KL X 7 nos) | BI01010001010000000000000515BI0100001935 | 2100 | KL |
825 | 17.14 | 300 kl at 22 Mtr stagging (300 KL X 3 nos) | BI01010001010000000000000515BI0100001936 | 900 | KL |
826 | 17.15 | 300 kl at 25 Mtr stagging (300 KL X 3 nos) | BI01010001010000000000000515BI0100001937 | 900 | KL |
827 | 17.16 | 350 kl at 20 Mtr stagging (350 KL X 5 nos) | BI01010001010000000000000515BI0100001938 | 1750 | KL |
828 | 17.17 | 350 kl at 22 Mtr stagging (350 KL X 3 nos) | BI01010001010000000000000515BI0100001939 | 1050 | KL |
829 | 17.18 | 350 kl at 25 Mtr stagging (350 KL X 4 nos) | BI01010001010000000000000515BI0100001940 | 1400 | KL |
830 | 17.19 | 400 kl at 20 Mtr stagging (400 KL X 4 nos) | BI01010001010000000000000515BI0100001941 | 1600 | KL |
831 | 17.2 | 400 kl at 25 Mtr stagging (400 KL X 1 nos) | BI01010001010000000000000515BI0100001942 | 400 | KL |
832 | 17.21 | 800kl at 25 Mtr stagging (800 KL X 1 nos) | BI01010001010000000000000515BI0100001943 | 800 | KL |
833 | 17.22 | 1000kl at 25 Mtr stagging (1000 KL X 1 nos) | BI01010001010000000000000515BI0100001944 | 1000 | KL |
834 | 17.23 | Providing and fixing double flanged ISI marked DI classK- 9 pipes as per IS:8329-2000 (amended upto date), as cortical pipes for RCC reservoirs including specials required such as duckfoot bend, bend tee Etc. Providing clamps at every 3 MTR, jointing metrials such as nuts, bolt,rubber packing, hydraulic testing etc. Complete in all respect upto and form valve chamber as per direction of EIC, technical specification and scope of work. | BI01010001010000000000000515BI0100001945 | ||
835 | 17.24 | 100 mm | BI01010001010000000000000515BI0100001946 | 3050 | mtr |
836 | 17.25 | 150 mm | BI01010001010000000000000515BI0100001947 | 2260 | mtr |
837 | 17.26 | 200 mm | BI01010001010000000000000515BI0100001948 | 2040 | mtr |
838 | 17.27 | 250mm | BI01010001010000000000000515BI0100001949 | 1250 | mtr |
839 | 17.28 | 300 mm | BI01010001010000000000000515BI0100001950 | 50 | mtr |
840 | 17.29 | 350 mm | BI01010001010000000000000515BI0100001951 | 50 | mtr |
841 | 17.3 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. PN 1.6 | BI01010001010000000000000515BI0100001952 | ||
842 | 17.31 | 100 mm | BI01010001010000000000000515BI0100001953 | 160 | No. |
843 | 17.32 | 150 mm | BI01010001010000000000000515BI0100001954 | 58 | No. |
844 | 17.33 | 200 mm | BI01010001010000000000000515BI0100001955 | 36 | No. |
845 | 17.34 | 250 mm | BI01010001010000000000000515BI0100001956 | 92 | No. |
846 | 17.35 | 300 mm | BI01010001010000000000000515BI0100001957 | 2 | No. |
847 | 17.36 | 350 mm | BI01010001010000000000000515BI0100001958 | 2 | No. |
848 | 17.37 | CI Dismantling joint for Chambers | BI01010001010000000000000515BI0100001959 | ||
849 | 17.38 | 100mm Dia | BI01010001010000000000000515BI0100001960 | 160 | No. |
850 | 17.39 | 150mm Dia | BI01010001010000000000000515BI0100001961 | 58 | No. |
851 | 17.4 | 200mm Dia | BI01010001010000000000000515BI0100001962 | 36 | No. |
852 | 17.41 | 250mm Dia | BI01010001010000000000000515BI0100001963 | 92 | No. |
853 | 17.42 | 300 mm Dia | BI01010001010000000000000515BI0100001964 | 2 | No. |
854 | 17.43 | 350 mm Dia | BI01010001010000000000000515BI0100001965 | 2 | No. |
855 | 17.44 | Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) | BI01010001010000000000000515BI0100001966 | 22500 | kg |
856 | 17.45 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001967 | 1 | Lot |
857 | 18 | Ancillary Works | BI01010001010000000000000515BI0100001968 | ||
858 | 18.01 | To Plan, Design, Construct and finish the following as per specifications as per detail given in Annexures. | BI01010001010000000000000515BI0100001969 | ||
859 | 18.02 | Residential Building J-2 type qtr full set at WTP | BI01010001010000000000000515BI0100001970 | 1 | Set |
860 | 18.03 | Residential Building J-2 type qtr half set at Aroli WTP & IPS head Works | BI01010001010000000000000515BI0100001971 | 7 | Set |
861 | 18.04 | Construction of Store at Aroli WTP, Pr. WTP HW and IPS HW | BI01010001010000000000000515BI0100001972 | 8 | Job |
862 | 18.05 | Campus development including general grading of the campus, Horticulture, landscape, water supply, Electrification, sanitation arrangement etc. | BI01010001010000000000000515BI0100001973 | ||
863 | 18.06 | At WTP | BI01010001010000000000000515BI0100001974 | 1 | each |
864 | 18.07 | At IPS & RWPH | BI01010001010000000000000515BI0100001975 | 7 | each |
865 | 18.08 | Construction of Exn. Office Building at location decided by EIC. | BI01010001010000000000000515BI0100001976 | 1 | Set |
866 | 18.09 | Construction of Boundary wall, around Head work at WTP (150x150m), IPS (100x100m) and at 70 No ESR sites (30x30M) Plot alrea | BI01010001010000000000000515BI0100001977 | 11400 | Mtr |
867 | 18.1 | Installation of MS Gates at Head Works & ESR sites : 2 at WTP HW. 1 at IPS & 1 at ESR site | BI01010001010000000000000515BI0100001978 | 78 | No |
868 | 18.11 | Construction of RCC (M-30) road at WTP, IPS head works & ESR Site | BI01010001010000000000000515BI0100001979 | 3650 | Mtr |
869 | 18.12 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001980 | 1 | Lot |
870 | 19 | Power Substation | BI01010001010000000000000515BI0100001981 | ||
871 | 19.01 | Provision for providing incomer arrangement from JVVNL 11 kv feeder to sub station unit 1W+1S substation unit are to be installed at each location including meter room as per the requirement of JVVNL | BI01010001010000000000000515BI0100001982 | 8 | No. |
872 | 19.02 | Provision for supply/ installation of compact sub station unit with 1w+1s transformers of various range at proposed Pumping Stations: | BI01010001010000000000000515BI0100001983 | ||
873 | 19.03 | At Aroli WTP ~ 1600 KVA CSS with 11 KV non extensible one way RMU + 1600 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole ACB (2500 Amp.) at LT side along with standard accessories | BI01010001010000000000000515BI0100001984 | 1 | Job |
874 | 19.04 | At proposed WTP ~ 1250 KVA CSS with 11 KV non extensible one way RMU + 1250 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole ACB (2000 Amp.) at LT side along with standard accessories | BI01010001010000000000000515BI0100001985 | 1 | Job |
875 | 19.05 | At proposed IPS -1 Badanayagaon ~ 1000 KVA CSS with 11 KV non extensible one way RMU + 1000 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole ACB (1600 Amp.) at LT side along with standard accessories | BI01010001010000000000000515BI0100001986 | 1 | Job |
876 | 19.06 | At IPS 2 ~ 500 KVA CSS with 11 KV non extensible one way RMU + 500 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole MCCB at LT side along with standard accessories | BI01010001010000000000000515BI0100001987 | 1 | Job |
877 | 19.07 | At IPS 3 ~ 500 KVA CSS with 11 KV non extensible one way RMU + 500 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole MCCB at LT side along with standard accessories | BI01010001010000000000000515BI0100001988 | 1 | Job |
878 | 19.08 | At IPS 4 ~ 500 KVA CSS with 11 KV non extensible one way RMU + 500 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole MCCB at LT side along with standard accessories | BI01010001010000000000000515BI0100001989 | 1 | Job |
879 | 19.09 | At IPS-5 ~ 400 KVA CSS with 11 KV non extensible one way RMU + 400 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole MCCB at LT side along with standard accessories | BI01010001010000000000000515BI0100001990 | 1 | Job |
880 | 19.1 | At IPS-6 ~ 400 KVA CSS with 11 KV non extensible one way RMU + 400 KVA 11/0.433 KV Dry Type Distribution Transformer with OLTC & RTCC Panel + 4 Pole MCCB at LT side along with standard accessories | BI01010001010000000000000515BI0100001991 | 1 | Job |
881 | 19.11 | Supplying of following size of XLPE insulated and PVC outer sheathed aluminium conductor armoured UG cable of 1.1 KV grade confirming to IS:7098 (Part-I) 1988 with upto date amendments complete as required. 3.5 x 185 Sq.mm | BI01010001010000000000000515BI0100001992 | 1500 | Mtr |
882 | 19.12 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001993 | 50 | Each |
883 | 19.13 | Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | BI01010001010000000000000515BI0100001994 | 100 | Mtr |
884 | 19.14 | Providing and fixing 25 mm X 6 mm aluminium strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. | BI01010001010000000000000515BI0100001995 | 225 | Mtr |
885 | 19.15 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100001996 | 1 | Lot |
886 | 20 | Functional House Hold Tap Connection | BI01010001010000000000000515BI0100001997 | ||
887 | 20.01 | Providing service connection as per technical specifications & standards drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter/ premises (complete job). This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of cement concrete, WBM, Black top etc of all thickness. Cutting of CC road/ jhiri by using concrete cutter machine, depositing & refilling of pit & jhiri with watering & ramming/ compacting in layers and disposal of surplus excavated soil as directed within a lead of 50 mtr, providing & fixing of all fittings dully approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS/PVC clamp with saddle piece gunmetal ferrule 4.0 mm (ISI marked), valve (IS : 778) and specials with MDPE Pipe PE-80 PN-12.5 as per ISO 4427 below ground level and P&F GI pipe 15 mm Dia Class B (ISI marked) above ground level in the premises for fixing tap (Max. length 2.0 mtr), P&F a 15 mm Bib cock with foam flow chrome plated with complete brass body including brass handle having good quality with weight 300 to 325 gm, including accessories with flushing, cleaning, disinfecting & testing of pipe line complete required for making of service connection complete in all respect including labour charges. In addition to ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumer's property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45cm below ground level, except in case of concrete/ bituminous road where minimum depth shall be 20cm. | BI01010001010000000000000515BI0100001998 | ||
888 | 20.02 | For detail specification of MDPE pipes, please refer section "Technical specifications" of bid document. General specification of MDPE pipes shall be as under: \n• The raw material shall be virgin PE-80 blue compound and comply with the requirement of ISO/ Directive of Testing Material: 9080 with minimum required strength of 8 kg/sq.cm.\n• The raw material shall be food grade quality\n• Pressure rating shall be 12.5 Bar\n• The pipe shall bear ISO marking | BI01010001010000000000000515BI0100001999 | ||
889 | 20.03 | Average length up to 05 meter 20mm dia MDPE Pipe and 02 meter 15 mm GI pipe Class B. (PHED BSR 2020/ 1.19 revised as per TM circular no. 1786-1892 dt. 10.09.2020) | BI01010001010000000000000515BI0100002000 | 82283 | Each |
890 | 20.04 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100002001 | 1 | Lot |
891 | 21 | PLC-SCADA SYSTEM | BI01010001010000000000000515BI0100002002 | ||
892 | 21.01 | Providing hardware and software for PLC and SCADA system at different locations, keeping central control at main Head works including civil works, complete in all respect as per the scope of work & specifications | BI01010001010000000000000515BI0100002003 | 1 | Lot |
893 | 21.02 | Other items & accessories not specified above but required to complete the work on turn key basis | BI01010001010000000000000515BI0100002004 | 1 | Lot |
894 | 22 | Miscellaneous items | BI01010001010000000000000515BI0100002005 | ||
895 | 22.01 | Survey of all propoerties, preparation of GIS based consumer mapping of consumer water connection and consumer service connectiosn and data base, plotting assets on GIS map etc. (Satelite image will be provide by the department) | BI01010001010000000000000515BI0100002006 | 82283 | FHTC |
896 | 22.02 | Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in;work includes visiting the village for collecting basic data consumers like i.e.\nAadhar no./ration card/voter ID/BPL card/PAN card/driving\nlicence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator. | BI01010001010000000000000515BI0100002007 | 82283 | FHTC |
897 | 22.03 | Provision for National Highway/ State Highway Crossing for Rising main, Cluster Dsitribution/Village Distribution by trenchless technology. | BI01010001010000000000000515BI0100002008 | 43 | No |
898 | 22.04 | Provision for Canal Crossing by trenchless technology | BI01010001010000000000000515BI0100002009 | 42 | No |
899 | 22.05 | Provision for River/Seasonal Nallah Crossing. | BI01010001010000000000000515BI0100002010 | 27 | No |
900 | 22.06 | Provision for Railway Crossing by trenchless technology. | BI01010001010000000000000515BI0100002011 | 3 | No |
901 | 22.07 | Supply of Mechanical & Electrical & instrumentation spare parts | BI01010001010000000000000515BI0100002012 | ||
902 | 22.08 | Spares for Electrical Works: water treatment plant | BI01010001010000000000000515BI0100002013 | ||
903 | 22.09 | Set of three lamps with resistors | BI01010001010000000000000515BI0100002014 | 2 | Set |
904 | 22.1 | Set of 3 push buttons | BI01010001010000000000000515BI0100002015 | 2 | Set |
905 | 22.11 | Volt meter (96 sqmm) | BI01010001010000000000000515BI0100002016 | 2 | No |
906 | 22.12 | Ampere meter (96 sqmm) for pumping set outgoing feeder | BI01010001010000000000000515BI0100002017 | 2 | No |
907 | 22.13 | Pressure gauge : 0-10 Kg | BI01010001010000000000000515BI0100002018 | 20 | Lot |
908 | 22.14 | Spares for Mechanical Works for Clear Water Pumping Stations & IPS | BI01010001010000000000000515BI0100002019 | ||
909 | 22.15 | Impellers for pumps : 1 no for each type pump installed under the contract | BI01010001010000000000000515BI0100002020 | 28 | Lot |
910 | 22.16 | Shaft and shaft sleeve of pumps : 1 no for each type pump installed under the contract | BI01010001010000000000000515BI0100002021 | 28 | Lot |
911 | 22.17 | Actuator for butterfly valves : 1 No. of following size | BI01010001010000000000000515BI0100002022 | ||
912 | 22.18 | 100mm | BI01010001010000000000000515BI0100002023 | 1 | Lot |
913 | 22.19 | 125mm | BI01010001010000000000000515BI0100002024 | 1 | Lot |
914 | 22.2 | 150mm | BI01010001010000000000000515BI0100002025 | 1 | Lot |
915 | 22.21 | 200mm | BI01010001010000000000000515BI0100002026 | 1 | Lot |
916 | 22.22 | 250mm | BI01010001010000000000000515BI0100002027 | 1 | Lot |
917 | 22.23 | 300mm | BI01010001010000000000000515BI0100002028 | 1 | Lot |
918 | 22.24 | 350mm | BI01010001010000000000000515BI0100002029 | 1 | Lot |
919 | 22.25 | 400mm | BI01010001010000000000000515BI0100002030 | 1 | Lot |
920 | 22.26 | 450mm | BI01010001010000000000000515BI0100002031 | 1 | Lot |
921 | 22.27 | 500mm | BI01010001010000000000000515BI0100002032 | 1 | Lot |
922 | 22.28 | 600mm | BI01010001010000000000000515BI0100002033 | 1 | Lot |
923 | 22.29 | 700mm | BI01010001010000000000000515BI0100002034 | 1 | Lot |
924 | 22.3 | Spares for Electrical Works for Clear Water Pumping Stations | BI01010001010000000000000515BI0100002035 | ||
925 | 22.31 | Selector switch | BI01010001010000000000000515BI0100002036 | 2 | No |
926 | 22.32 | Set of three lamps with resistors | BI01010001010000000000000515BI0100002037 | 6 | Set |
927 | 22.33 | Set of 3 push buttons | BI01010001010000000000000515BI0100002038 | 6 | Set |
928 | 22.34 | Volt meter (96 sqmm) | BI01010001010000000000000515BI0100002039 | 6 | No |
929 | 22.35 | Ampere meter (96 sqmm) for pumping set outgoing feeder | BI01010001010000000000000515BI0100002040 | 6 | No |
930 | 22.36 | Spares for Electrical Works for Sub Stations | BI01010001010000000000000515BI0100002041 | ||
931 | 22.37 | Power Transformer | BI01010001010000000000000515BI0100002042 | ||
932 | 22.38 | Conductor clamp : 1 Set of each type. | BI01010001010000000000000515BI0100002043 | 3 | Lot |
933 | 22.39 | Soft Staters for panels | BI01010001010000000000000515BI0100002044 | ||
934 | 22.4 | 6-WIRE UPTO 45KW, SOFT STARTER 47A 440V 230V CTRL | BI01010001010000000000000515BI0100002045 | 7 | Lot |
935 | 22.41 | 6-WIRE UPTO 55KW , SOFT STARTER 62A 440V 230V CTRL | BI01010001010000000000000515BI0100002046 | 1 | Lot |
936 | 22.42 | 6-WIRE UPTO 75KW ELECTRONIC SOFT STARTER CONTROL 220V POW | BI01010001010000000000000515BI0100002047 | 7 | Lot |
937 | 22.43 | 6-WIRE UPTO 90KW, ELECTRONIC SOFT STARTER CONTROL 220V POW | BI01010001010000000000000515BI0100002048 | 6 | Lot |
938 | 22.44 | 6-WIRE UPTO 110KW ELECTRONIC SOFT STARTER CONTROL 220V POW | BI01010001010000000000000515BI0100002049 | 3 | Lot |
939 | 22.45 | 6-WIRE UPTO 160KW SOFT STARTER 210A 440V 230V CTRL | BI01010001010000000000000515BI0100002050 | 4 | Lot |
940 | 22.46 | 6-WIRE UPTO 220KW SOFT STARTER 250A 440V 230V CTRL | BI01010001010000000000000515BI0100002051 | 2 | Lot |
941 | 22.47 | 6-WIRE UPTO 315KW SOFT STARTER 410A 440V 230V CTRL | BI01010001010000000000000515BI0100002052 | 2 | Lot |
942 | 22.48 | Main contactors for LT Panels, Coil voltage 220 V, NONC with Adin Block each pic per main contactor | BI01010001010000000000000515BI0100002053 | ||
943 | 22.49 | 80 Amp | BI01010001010000000000000515BI0100002054 | 4 | No |
944 | 22.5 | 100 Amp | BI01010001010000000000000515BI0100002055 | 3 | No |
945 | 22.51 | 150 Amp | BI01010001010000000000000515BI0100002056 | 8 | No |
946 | 22.52 | 200 Amp | BI01010001010000000000000515BI0100002057 | 6 | No |
947 | 22.53 | 250 Amp | BI01010001010000000000000515BI0100002058 | 3 | No |
948 | 22.54 | 350 Amp | BI01010001010000000000000515BI0100002059 | 6 | No |
949 | 22.55 | 600 Amp | BI01010001010000000000000515BI0100002060 | 2 | No |
950 | 22.56 | Supply of pipe line spare parts | BI01010001010000000000000515BI0100002061 | ||
951 | 22.57 | Sluice valve rod with check nut | BI01010001010000000000000515BI0100002062 | ||
952 | 22.58 | 80 mm. | BI01010001010000000000000515BI0100002063 | 10 | No |
953 | 22.59 | 100 mm | BI01010001010000000000000515BI0100002064 | 10 | No |
954 | 22.6 | 125 mm | BI01010001010000000000000515BI0100002065 | 10 | No |
955 | 22.61 | 150 mm | BI01010001010000000000000515BI0100002066 | 10 | No |
956 | 22.62 | 200 mm | BI01010001010000000000000515BI0100002067 | 10 | No |
957 | 22.63 | 250 mm | BI01010001010000000000000515BI0100002068 | 10 | No |
958 | 22.64 | 300mm | BI01010001010000000000000515BI0100002069 | 5 | No |
959 | 22.65 | 350mm | BI01010001010000000000000515BI0100002070 | 10 | No |
960 | 22.66 | 400mm | BI01010001010000000000000515BI0100002071 | 5 | No |
961 | 22.67 | 500mm | BI01010001010000000000000515BI0100002072 | 2 | No |
962 | 22.68 | 600mm | BI01010001010000000000000515BI0100002073 | 2 | No |
963 | 22.69 | 700mm | BI01010001010000000000000515BI0100002074 | 2 | No |
964 | 22.7 | 800mm | BI01010001010000000000000515BI0100002075 | 2 | No |
965 | 22.71 | Air Valve Balls | BI01010001010000000000000515BI0100002076 | ||
966 | 22.72 | 50 mm | BI01010001010000000000000515BI0100002077 | 50 | No |
967 | 22.73 | 80 mm. | BI01010001010000000000000515BI0100002078 | 40 | No |
968 | 22.74 | 100 mm | BI01010001010000000000000515BI0100002079 | 20 | No |
969 | 22.75 | Air valve’s orifice plate | BI01010001010000000000000515BI0100002080 | ||
970 | 22.76 | 50 mm | BI01010001010000000000000515BI0100002081 | 12 | No |
971 | 22.77 | 80 mm. | BI01010001010000000000000515BI0100002082 | 12 | No |
972 | 22.78 | 100 mm | BI01010001010000000000000515BI0100002083 | 12 | No |
973 | 22.79 | Gaskets for all valves EPDM | BI01010001010000000000000515BI0100002084 | ||
974 | 22.8 | Sluice Valves | BI01010001010000000000000515BI0100002085 | ||
975 | 22.81 | 80 mm. | BI01010001010000000000000515BI0100002086 | 10 | No |
976 | 22.82 | 100 mm | BI01010001010000000000000515BI0100002087 | 10 | No |
977 | 22.83 | 125 mm | BI01010001010000000000000515BI0100002088 | 10 | No |
978 | 22.84 | 150 mm | BI01010001010000000000000515BI0100002089 | 10 | No |
979 | 22.85 | 200 mm | BI01010001010000000000000515BI0100002090 | 10 | No |
980 | 22.86 | 250mm | BI01010001010000000000000515BI0100002091 | 10 | No |
981 | 22.87 | 300mm | BI01010001010000000000000515BI0100002092 | 5 | No |
982 | 22.88 | 350mm | BI01010001010000000000000515BI0100002093 | 10 | No |
983 | 22.89 | 400mm | BI01010001010000000000000515BI0100002094 | 5 | No |
984 | 22.9 | 500mm | BI01010001010000000000000515BI0100002095 | 2 | No |
985 | 22.91 | 600mm | BI01010001010000000000000515BI0100002096 | 2 | No |
986 | 22.92 | 700mm | BI01010001010000000000000515BI0100002097 | 2 | No |
987 | 22.93 | 800mm | BI01010001010000000000000515BI0100002098 | 2 | No |
988 | 22.94 | Butterfly Valve | BI01010001010000000000000515BI0100002099 | ||
989 | 22.95 | 100 mm | BI01010001010000000000000515BI0100002100 | 5 | No |
990 | 22.96 | 125 mm | BI01010001010000000000000515BI0100002101 | 5 | No |
991 | 22.97 | 150 mm | BI01010001010000000000000515BI0100002102 | 5 | No |
992 | 22.98 | 200 mm | BI01010001010000000000000515BI0100002103 | 5 | No |
993 | 22.99 | 250 mm | BI01010001010000000000000515BI0100002104 | 5 | No |
994 | 23 | 300mm | BI01010001010000000000000515BI0100002105 | 5 | No |
995 | 23.01 | 350mm | BI01010001010000000000000515BI0100002106 | 5 | No |
996 | 23.02 | 400mm | BI01010001010000000000000515BI0100002107 | 2 | No |
997 | 23.03 | 500mm | BI01010001010000000000000515BI0100002108 | 2 | No |
998 | 23.04 | 600mm | BI01010001010000000000000515BI0100002109 | 2 | No |
999 | 23.05 | 700mm | BI01010001010000000000000515BI0100002110 | 2 | No |
1000 | 23.06 | 800mm | BI01010001010000000000000515BI0100002111 | 2 | No |
1001 | 23.07 | Air Valve | BI01010001010000000000000515BI0100002112 | ||
1002 | 23.08 | 50 mm | BI01010001010000000000000515BI0100002113 | 30 | No |
1003 | 23.09 | 80 mm. | BI01010001010000000000000515BI0100002114 | 20 | No |
1004 | 23.1 | 100 mm | BI01010001010000000000000515BI0100002115 | 10 | No |
1005 | 23.11 | Dual Plate Check Valve | BI01010001010000000000000515BI0100002116 | ||
1006 | 23.12 | 100mm | BI01010001010000000000000515BI0100002117 | 2 | No |
1007 | 23.13 | 125mm | BI01010001010000000000000515BI0100002118 | 2 | No |
1008 | 23.14 | 150 mm | BI01010001010000000000000515BI0100002119 | 2 | No |
1009 | 23.15 | 200mm | BI01010001010000000000000515BI0100002120 | 2 | No |
1010 | 23.16 | 250mm | BI01010001010000000000000515BI0100002121 | 2 | No |
1011 | 23.17 | 300mm | BI01010001010000000000000515BI0100002122 | 2 | No |
1012 | 23.18 | 350mm | BI01010001010000000000000515BI0100002123 | 2 | No |
1013 | 23.19 | 400mm | BI01010001010000000000000515BI0100002124 | 2 | No |
1014 | 23.2 | 450mm | BI01010001010000000000000515BI0100002125 | 2 | No |
1015 | 23.21 | 500mm | BI01010001010000000000000515BI0100002126 | 2 | No |
1016 | 23.22 | 700mm | BI01010001010000000000000515BI0100002127 | 2 | No |
1017 | 23.23 | All sizes of DI pipes | BI01010001010000000000000515BI0100002128 | ||
1018 | 23.24 | DI K-7 Pipe | BI01010001010000000000000515BI0100002129 | ||
1019 | 23.25 | 80mm | BI01010001010000000000000515BI0100002130 | 250 | Meter |
1020 | 23.26 | 100mm | BI01010001010000000000000515BI0100002131 | 250 | Meter |
1021 | 23.27 | 150mm | BI01010001010000000000000515BI0100002132 | 250 | Meter |
1022 | 23.28 | 200mm | BI01010001010000000000000515BI0100002133 | 250 | Meter |
1023 | 23.29 | 250mm | BI01010001010000000000000515BI0100002134 | 250 | Meter |
1024 | 23.3 | 300mm | BI01010001010000000000000515BI0100002135 | 100 | Meter |
1025 | 23.31 | 350mm | BI01010001010000000000000515BI0100002136 | 100 | Meter |
1026 | 23.32 | 400mm | BI01010001010000000000000515BI0100002137 | 100 | Meter |
1027 | 23.33 | 500mm | BI01010001010000000000000515BI0100002138 | 100 | Meter |
1028 | 23.34 | 600mm | BI01010001010000000000000515BI0100002139 | 100 | Meter |
1029 | 23.35 | 700mm | BI01010001010000000000000515BI0100002140 | 100 | Meter |
1030 | 23.36 | DI K-9 Pipe | BI01010001010000000000000515BI0100002141 | ||
1031 | 23.37 | 100mm | BI01010001010000000000000515BI0100002142 | 200 | Meter |
1032 | 23.38 | 150mm | BI01010001010000000000000515BI0100002143 | 200 | Meter |
1033 | 23.39 | 200mm | BI01010001010000000000000515BI0100002144 | 200 | Meter |
1034 | 23.4 | 250mm | BI01010001010000000000000515BI0100002145 | 200 | Meter |
1035 | 23.41 | All sizes of HDPE pipes | BI01010001010000000000000515BI0100002146 | ||
1036 | 23.42 | 75mm | BI01010001010000000000000515BI0100002147 | 1000 | Meter |
1037 | 23.43 | 90mm | BI01010001010000000000000515BI0100002148 | 1000 | Meter |
1038 | 23.44 | 110mm | BI01010001010000000000000515BI0100002149 | 500 | Meter |
1039 | 23.45 | 125mm | BI01010001010000000000000515BI0100002150 | 300 | Meter |
1040 | 23.46 | 140mm | BI01010001010000000000000515BI0100002151 | 300 | Meter |
1041 | 23.47 | 160mm | BI01010001010000000000000515BI0100002152 | 300 | Meter |
1042 | 23.48 | 180mm | BI01010001010000000000000515BI0100002153 | 300 | Meter |
1043 | 23.49 | 200mm | BI01010001010000000000000515BI0100002154 | 300 | Meter |
1044 | 23.5 | MS Pipe | BI01010001010000000000000515BI0100002155 | ||
1045 | 23.51 | 80mm 4.5 mm thick | BI01010001010000000000000515BI0100002156 | 50 | Meter |
1046 | 23.52 | 100mm 4.7 mm thick | BI01010001010000000000000515BI0100002157 | 50 | Meter |
1047 | 23.53 | 125mm 5 mm thick | BI01010001010000000000000515BI0100002158 | 50 | Meter |
1048 | 23.54 | 150mm 5 mm thick | BI01010001010000000000000515BI0100002159 | 50 | Meter |
1049 | 23.55 | 200mm 5 mm thick | BI01010001010000000000000515BI0100002160 | 50 | Meter |
1050 | 23.56 | 250mm 5 mm thick | BI01010001010000000000000515BI0100002161 | 50 | Meter |
1051 | 23.57 | 300mm 5 mm thick | BI01010001010000000000000515BI0100002162 | 20 | Meter |
1052 | 23.58 | 350mm 5 mm thick | BI01010001010000000000000515BI0100002163 | 20 | Meter |
1053 | 23.59 | 400mm 6 mm thick | BI01010001010000000000000515BI0100002164 | 20 | Meter |
1054 | 23.6 | 500mm 6 mm thick | BI01010001010000000000000515BI0100002165 | 20 | Meter |
1055 | 23.61 | 600mm 6 mm thick | BI01010001010000000000000515BI0100002166 | 20 | Meter |
1056 | 23.62 | 700mm 8 mm thick | BI01010001010000000000000515BI0100002167 | 20 | Meter |
1057 | 23.63 | 800mm 8 mm thick | BI01010001010000000000000515BI0100002168 | 50 | Meter |
1058 | 23.64 | CID joints Long collar suitable for DI Pipes with nut bolt complete | BI01010001010000000000000515BI0100002169 | ||
1059 | 23.65 | 80mm | BI01010001010000000000000515BI0100002170 | 75 | No |
1060 | 23.66 | 100mm | BI01010001010000000000000515BI0100002171 | 75 | No |
1061 | 23.67 | 150mm | BI01010001010000000000000515BI0100002172 | 75 | No |
1062 | 23.68 | 200mm | BI01010001010000000000000515BI0100002173 | 75 | No |
1063 | 23.69 | 250mm | BI01010001010000000000000515BI0100002174 | 75 | No |
1064 | 23.7 | 300 mm | BI01010001010000000000000515BI0100002175 | 10 | No |
1065 | 23.71 | 350mm | BI01010001010000000000000515BI0100002176 | 10 | No |
1066 | 23.72 | 400mm | BI01010001010000000000000515BI0100002177 | 10 | No |
1067 | 23.73 | 500 mm | BI01010001010000000000000515BI0100002178 | 5 | No |
1068 | 23.74 | 600mm | BI01010001010000000000000515BI0100002179 | 5 | No |
1069 | 23.75 | 700 mm | BI01010001010000000000000515BI0100002180 | 5 | No |
1070 | 23.76 | Glan cap for sluice valves | BI01010001010000000000000515BI0100002181 | ||
1071 | 23.77 | 100mm | BI01010001010000000000000515BI0100002182 | 12 | No |
1072 | 23.78 | 150mm | BI01010001010000000000000515BI0100002183 | 12 | No |
1073 | 23.79 | 200mm | BI01010001010000000000000515BI0100002184 | 12 | No |
1074 | 23.8 | 250mm | BI01010001010000000000000515BI0100002185 | 12 | No |
1075 | 23.81 | 300mm | BI01010001010000000000000515BI0100002186 | 12 | No |
1076 | 23.82 | 350 mm | BI01010001010000000000000515BI0100002187 | 12 | No |
1077 | 23.83 | 400 mm | BI01010001010000000000000515BI0100002188 | 12 | No |
1078 | 23.84 | 500 mm | BI01010001010000000000000515BI0100002189 | 5 | No |
1079 | 23.85 | 600mm | BI01010001010000000000000515BI0100002190 | 5 | No |
1080 | 23.86 | 700 mm | BI01010001010000000000000515BI0100002191 | 5 | No |
1081 | 23.87 | 800mm | BI01010001010000000000000515BI0100002192 | 5 | No |
1082 | 23.88 | CID joints for HDPE pipes | BI01010001010000000000000515BI0100002193 | ||
1083 | 23.89 | 75 mm | BI01010001010000000000000515BI0100002194 | 300 | No |
1084 | 23.9 | 90 mm | BI01010001010000000000000515BI0100002195 | 300 | No |
1085 | 23.91 | 110 mm | BI01010001010000000000000515BI0100002196 | 250 | No |
1086 | 23.92 | 125 mm | BI01010001010000000000000515BI0100002197 | 150 | No |
1087 | 23.93 | 140 mm | BI01010001010000000000000515BI0100002198 | 150 | No |
1088 | 23.94 | 160 mm | BI01010001010000000000000515BI0100002199 | 100 | No |
1089 | 23.95 | 180 mm | BI01010001010000000000000515BI0100002200 | 25 | No |
1090 | 23.96 | 200 mm | BI01010001010000000000000515BI0100002201 | 10 | No |
1091 | 23.97 | Nuts & bolts (50 kg of each type & size) for CID joints | BI01010001010000000000000515BI0100002202 | 500 | Kg |
1092 | 23.98 | Rubber sheet Neoprine | BI01010001010000000000000515BI0100002203 | 1500 | Kg |
1093 | 23.99 | Supply of tools & tackles | BI01010001010000000000000515BI0100002204 | ||
1094 | 24 | Pipe wrench 10”, 14” 18” and 24" of ISI mark | BI01010001010000000000000515BI0100002205 | 7 | Set |
1095 | 24.01 | Screw Driver set | BI01010001010000000000000515BI0100002206 | 7 | No |
1096 | 24.02 | Flat files of size 8", 10" 12" | BI01010001010000000000000515BI0100002207 | 7 | Set |
1097 | 24.03 | Aluminium folding ledder of 8 meter | BI01010001010000000000000515BI0100002208 | 7 | No |
1098 | 24.04 | Rubber hand gloves 11KV | BI01010001010000000000000515BI0100002209 | 7 | Set |
1099 | 24.05 | Half round files of size 8", 10" 12" | BI01010001010000000000000515BI0100002210 | 7 | Set |
1100 | 24.06 | Hammer of 200gm, 450gm, 1kg & 5kg weight with wooden handle. | BI01010001010000000000000515BI0100002211 | 7 | Set |
1101 | 24.07 | Nose Plier | BI01010001010000000000000515BI0100002212 | 7 | No |
1102 | 24.08 | Plier 8" & 10" | BI01010001010000000000000515BI0100002213 | 7 | Set |
1103 | 24.09 | Hydraulic crimping tool, 25 to 400 sq mm | BI01010001010000000000000515BI0100002214 | 7 | Set |
1104 | 24.1 | Set of Ring spanners & Fixed spanners (covering all sizes) | BI01010001010000000000000515BI0100002215 | 7 | Set |
1105 | 24.11 | Set of Tommy | BI01010001010000000000000515BI0100002216 | 7 | Set |
1106 | 24.12 | Diesel operated Generator Set of Minimum 16 KVA capacity with trolly & welding machine 300 A(double circuit), equipments for repair of DI/MS/HDPE pipe lines | BI01010001010000000000000515BI0100002217 | 7 | lot |
1107 | 24.13 | Hydraulic Welding machine for jointing of HDPE pipe line of all sizes, complete set with all required accessories. | BI01010001010000000000000515BI0100002218 | 7 | Set |
1108 | 24.14 | Hexa Frame with 2 dozen blades | BI01010001010000000000000515BI0100002219 | 7 | lot |
1109 | 24.15 | Honda dewatering set 6 LPS, 10-15 M head | BI01010001010000000000000515BI0100002220 | 14 | No |
1110 | 24.16 | Clamp meter cum tongue tester with accessories of Indian make | BI01010001010000000000000515BI0100002221 | 7 | No |
1111 | 24.17 | Megger 1000 KVA | BI01010001010000000000000515BI0100002222 | 3 | No |
1112 | 24.18 | Megger 5000 KVA | BI01010001010000000000000515BI0100002223 | 3 | No |
1113 | 24.19 | Lawn Mover | BI01010001010000000000000515BI0100002224 | 7 | No |
1114 | 24.2 | Big size Torch for pipeline patrolling purpose | BI01010001010000000000000515BI0100002225 | 7 | No |
1115 | 24.21 | Multimeter for 4-20 mA/0-10 V DC measurement | BI01010001010000000000000515BI0100002226 | 4 | Nos |
1116 | 24.22 | Electrically operated pipe cutter cum grinder of capacity to cut and grind highest diameter of pipe in the project with all accessories and 6 nos. grinding and cutting blades for each size of pipes. | BI01010001010000000000000515BI0100002227 | 7 | lot |
1117 | 25 | PRICE BREAK UP SCHEDULE: B | BI01010001010000000000000515BI0100002228 | ||
1118 | 25.01 | For 10 Year O & M | BI01010001010000000000000515BI0100002229 | ||
1119 | 25.02 | Cost for Basic Service Charges, including all chemicals required, to treat water at WTP, Administration and Management, Running of Office, Staff Quarters, Work Shops, Garage, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Cost of Lubricants, Consumables, Spare Parts as per Scope of Work & terms & conditions of contract. After execution of the project and issuance of completion certificate as per relevant clause in Vol-1, Defect Liability Period shall be of 12 months. During Defect liability period O&M shall be done by contractor for which no payment shall be made separately. O&M period shall commence after expiry of defect liability period. | BI01010001010000000000000515BI0100002230 | ||
1120 | 25.03 | For Year 1 of O&M | BI01010001010000000000000515BI0100002231 | ||
1121 | 25.04 | O&M Charges | BI01010001010000000000000515BI0100002232 | 1 | lot |
1122 | 25.05 | Chemical Charges | BI01010001010000000000000515BI0100002233 | 1 | lot |
1123 | 25.06 | For Year 2 of O&M | BI01010001010000000000000515BI0100002234 | ||
1124 | 25.07 | O&M Charges | BI01010001010000000000000515BI0100002235 | 1 | lot |
1125 | 25.08 | Chemical Charges | BI01010001010000000000000515BI0100002236 | 1 | lot |
1126 | 25.09 | For Year 3 of O&M | BI01010001010000000000000515BI0100002237 | ||
1127 | 25.1 | O&M Charges | BI01010001010000000000000515BI0100002238 | 1 | lot |
1128 | 25.11 | Chemical Charges | BI01010001010000000000000515BI0100002239 | 1 | lot |
1129 | 25.12 | For Year 4 of O&M | BI01010001010000000000000515BI0100002240 | ||
1130 | 25.13 | O&M Charges | BI01010001010000000000000515BI0100002241 | 1 | lot |
1131 | 25.14 | Chemical Charges | BI01010001010000000000000515BI0100002242 | 1 | lot |
1132 | 25.15 | For Year 5 of O&M | BI01010001010000000000000515BI0100002243 | ||
1133 | 25.16 | O&M Charges | BI01010001010000000000000515BI0100002244 | 1 | lot |
1134 | 25.17 | Chemical Charges | BI01010001010000000000000515BI0100002245 | 1 | lot |
1135 | 25.18 | For Year 6 of O&M | BI01010001010000000000000515BI0100002246 | ||
1136 | 25.19 | O&M Charges | BI01010001010000000000000515BI0100002247 | 1 | lot |
1137 | 25.2 | Chemical Charges | BI01010001010000000000000515BI0100002248 | 1 | lot |
1138 | 25.21 | For Year 7 of O&M | BI01010001010000000000000515BI0100002249 | ||
1139 | 25.22 | O&M Charges | BI01010001010000000000000515BI0100002250 | 1 | lot |
1140 | 25.23 | Chemical Charges | BI01010001010000000000000515BI0100002251 | 1 | lot |
1141 | 25.24 | For Year 8 of O&M | BI01010001010000000000000515BI0100002252 | ||
1142 | 25.25 | O&M Charges | BI01010001010000000000000515BI0100002253 | 1 | lot |
1143 | 25.26 | Chemical Charges | BI01010001010000000000000515BI0100002254 | 1 | lot |
1144 | 25.27 | For Year 9 of O&M | BI01010001010000000000000515BI0100002255 | ||
1145 | 25.28 | O&M Charges | BI01010001010000000000000515BI0100002256 | 1 | lot |
1146 | 25.29 | Chemical Charges | BI01010001010000000000000515BI0100002257 | 1 | lot |
1147 | 25.3 | For Year 10 of O&M | BI01010001010000000000000515BI0100002258 | ||
1148 | 25.31 | O&M Charges | BI01010001010000000000000515BI0100002259 | 1 | lot |
1149 | 25.32 | Chemical Charges | BI01010001010000000000000515BI0100002260 | 1 | lot |