Public Works Department-PWD has published Maintenance Of Electrical Installation And Fans , Rmo Pump Sets , Compound Light At Delhi Archive Building , Qutab Institutional Area , New Delhi . ( Sh- Operation And Maintenance Of Substation And Dg Set , Lift , Various Ei And Fans And Fire Alar. Submission Date for this Tender is 12-04-2021. Completion Equipments Tenders in at Delhi Archive Building Delhi. Bidders can get complete Tender details and download the document.
Name of Work: MOEI & Fans, RMO Pump Sets, Compound Light at Delhi Archive Building, Qutab Institutional Area, New Delhi. (SH:- Operation and maintenance of Substation & DG Set, Lift, various EI & Fans and Fire Alarm System, CO2 Flooding bank System) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Sub Head -I (EI )\nRoutine maintenance of EI and fans, street lights main boards & DBs, submain/circuit wiring, complete with allied fixtures. In all days of the month except Sundays and holidays. Terms and conditions as specified.\na) Wireman – 1 No.\nb) Khallasi- 1 No.\n | 12 | Months | |
2 | 2 | Sub Head -II ( Substation)\nOperation and routine maintenance of 500 KVA 11 KV/415 Volts electric sub station and allied equipment i/c HT & LT switch gears, cables & D.G. set, protective equipment on all days i/c Sundays and holidays by providing following minimum staff and in accordance with the scope of work, as per terms & conditions as specified.\nInventory :\ni) HT Panel - 1 No.\nii) LT Panel - 1 No.\niii) 500 KVA oil type - 2 Nos. transformer.\niv) Cable switch gear etc.\nv) 160 KVA D.G. Set.- 1 No.\nvi) 30 KVA D.G. Set.- 2 Nos.\na) DG Set Operator/Wireman – 3 Nos.\nb) Khallasi – 1 No.\n | 12 | Months | |
3 | 3 | Sub Head -III (Operation of Lift)\nOperation of following Lifts on all days of the month excluding Sundays & Holidays as per terms & conditions attached and by providing following minimum staff : \na) 13 Passengers Lift -2 Nos. \nb) Dump Waiter – 1 No.\nLift operator-2 Nos. (9 AM to 5 PM)\n | 12 | Months | |
4 | 4 | Sub Head -IV (Operation of Fire Fighting System)\nRoutine maintenance and operation of following fire fighting and fire detection installation i/c routine testing of all equipments upkeeping all installation in operational and tiddy conditions on all days i/c Saturday Sunday and holidays as per terms and conditions attached\ni) Wet riser system complete with all associated installation such as hose reel, hose drum, main fire pumping set, pressurization pumping set, diesel engine driven, pumpin sets along with panel board and associated accessories.\nii) Conventional fire alarm system complete with heat/ smoke detector along with there associated accessories etc.\nii) CO2 flooding separation system comprising with 32 x 45 kg. CO2 fire cylinder and fire cylinder etc.\n(a) Fire Operator – 3 Nos.\n(b) Khallasi – 1 No.\n | 12 | Months | |
5 | 5 | Sub Head -V (Supply of Material)\nFollowing material shall be supplied by agency and existing manpower shall be used for replacement on day to day maintenance works | |||
6 | 5.01 | 5/6 Amp Switch (Piano Type) | 100 | Nos | |
7 | 5.02 | 3 Pin 5/6 Amp Socket Outlet (Piano Type) | 50 | Nos | |
8 | 5.03 | 15/16 Amp Switch (Piano Type) | 150 | Nos | |
9 | 5.04 | 15/16 Amp Socket (Piano Type) | 150 | Nos | |
10 | 5.05 | 5/6 Amp Switch (Modular Type) | 200 | Nos | |
11 | 5.06 | 3 Pin 5/6 Amp Socket Outlet (Modular Type) | 200 | Nos | |
12 | 5.07 | 15/16 Amp Switch (Modular Type) | 200 | Nos | |
13 | 5.08 | 15/16 Amp Socket (Modular Type) | 200 | Nos | |
14 | 5.09 | 6 to 32 Amp SP MCB 'C' Curve | 200 | Nos | |
15 | 5.1 | 100 Amp. TP MCCB 16 KA | 20 | Nos | |
16 | 5.11 | 1.5 Sq.mm FRLS PVC insulated cu. Wire | 500 | Mtrs | |
17 | 5.12 | 4 sq.mm FRLS PVC insulated cu. Wire | 250 | Mtrs | |
18 | 5.13 | 6 sq.mm FRLS PVC insulated cu. Wire | 100 | Mtrs | |
19 | 6 | Supplying of 1200mm sweep ceiling fan with BEE rating of 5 star i/c the down rod of standard length (upto 30cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required. | 60 | Nos | |
20 | 7 | Supply of surface/wall mounted, Not more than 18-20 W LED Batten with a system lumen output of 2200 lumens and a minimum system efficacy of 110 lumen/watt. The luminaire shall have a CRI of greater than or equal to 80. The luminaire is made of pre die cast housing and B17 Input voltage range 140-270V, CCT-- 5700, P.F>0.95, CRI>80,, LED Service life 50000 operating hoursat L70 i/c connection with 1.5 sq. mm copper conductor, single core cable and earthing etc as reqd. | 100 | Nos | |
21 | 8 | Supplying of 900 rpm 300mm sweep exhaust fan metal body complete with louvers/ shutters in the existing opening i/c making the hole to suit the size of the above fan making good the damage & connections i/c less credit of old dismental material as and where basis etc. as reqd. | 25 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy