Consultancy Of Supply Of Architectural Structural Drawing Design And Preparation Of Boq Estimates And Rate Analysis Provn Of Fire Exit Ladder Around Sre Bldg At 17 Wg Gkp, HQ CWEAFBAMRAULI-Uttar Pradesh

Military Engineer Services-MES has published Consultancy Of Supply Of Architectural Structural Drawing Design And Preparation Of Boq Estimates And Rate Analysis Provn Of Fire Exit Ladder Around Sre Bldg At 17 Wg Gkp. Submission Date for this Tender is 17-04-2021. Bearings Tenders in HQ CWEAFBAMRAULI Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27559381
Corrigendum : Consultancy Of Supply Of Architectural Structural Drawing Design And Preparation Of Boq Estimates And Rate Analysis Provn Of Fire Exit Ladder Around Sre Bldg At 17 Wg Gkp
Open Tender
Indian
Uttar Pradesh
HQ CWEAFBAMRAULI
17-04-2021

Tender Details

Consultancy Of Supply Of Architectural Structural Drawing Design And Preparation Of Boq Estimates And Rate Analysis Provn Of Fire Exit Ladder Around Sre Bldg At 17 Wg Gkp , Supply Of Architectural , Structure Drawing & Design And Preparation Of Boq Estimates And Rate Analysis For Provn Of Fire Exit Ladder Around Sre Buildings At 17 Wing . Brief Scope Of WorkBldg Comprises The Following :- ( A ) Additional Stair Case Adjacent To Existing Sre Bldg Up To Fifth Floor . Maint Stair Case=6 . 40X3 . 20 =20 . 48 ( A ) , Connecting Passage =1 . 20X2 . 50=3 . 00 , ( B ) Total Area Plinth = ( A+B ) X5 ( Floors ) = ( 20 . 48+3 . 00 ) X5=117 . 40 Sqm , Say 118 Sqm ( B ) Construction Of Pump House With Permanent Specification 4Mtrx4mtr=16 Sqm ( C ) Construction Of Top Open Semi Under Ground Sump Of Capacity 80Kl = 01 Nos ( D ) Height Of Bldg From Ffl- 3 . 60Mtrx5=18 Mtr ( Stair Case ) , 3 . 2 Mtr For Pump House . ( E ) Plinth Ht Of Bldg From Existing Dispersal For Stair Case . Brief Specification ( A ) Foundation- To Be Designed For Rcc M-25 ( Design Mix ) , ( B ) Rcc Framed Structure With Rcc Roof Slab Reinforcement Shall Be Tmt Fe 500D , ( C ) Brick Wall Shall Be 230Mm . ( D ) Water Proofing Treatment App Roof Treatment . ( E ) Plastering Internal-15Mm Thk In Cm 1:6 And External 15Mm Thk In Cm 1:4 . ( F ) Soil Bearing Capacity-8 T/M2 ( Tentative ) . Same To Be Reconfirmed From Soil Investigation Report Or Soil Data Provided By Ge . ( G ) Flooring & Skirting- 18-22Mm Th Kota Stone For Starcase , Pcc For Pump House And Rcc Flooring Internal For Ug Sump Out Side Pqc/Hard Standing . ( Ii ) Non-Skid Ceramic Tiles For Toilet . ( Iii ) Glazed Ceramic Tiles For Dado In Toilet ( H ) Joinery Collapsible Door For Stair Case & Other Pressed Steel Framed With Factory Made Panelled Shutter: ( J ) Door & Windows- Panel Door With Fly Proofing And Steel Window With Fly Proofing And Guard Bar Shell Be Provided . Curtain Rods To Be Provided Over Door And Window . ( Ii ) Toilet- Pre Laminated Pvc Door Frame With Shutter , ( Ii ) Finishes External: Cement Base Paint . Internal: White Wash With Primer , ( K ) Plinth Protection: 750Mm Wide 75Mm Thk Pcc 1:3:6 Over 100Mm Thk Hard Core . ( L ) Rcc M-30 For Top Open Semi Ug Sump . Structural AspectProvn Of Supply Of Strucural Design Drawing With Sound Engineering Practice In Auto Cad With Latest Indian Standards Is 456 , Is 800 , Is 816 , Is 1893 , Is 2062 Is 4326 , Is 13920 Etc , Including Design Calculations Folders Alongwith Staad Output File ( Hard And Soft Copy ) And One Set Of Original Tracing Hard Copy ( A1 Size ) On Gateway Brand Tracing Paper Alongwith A Soft Copy Of Drawing . The Design Prepared By One Designer Shall Be Checked By Another Designer And Both The Persons Shall Sign In The Design Calculations And Drawings . The Drawings Will Be Got Vetted By Iit/Mnit/Nit/Govt Engg College Only And Duly Countersigned Before Submission To Department . ( I ) Any Amendment Required During Tender Presentation And On Later During Execution Shall Be Mady By The Consultant And Require Copies Of The Amended Sheets Shall Be Submitted And Free Of Cost Alongwith Clarifications , If Any , During Complete Execution Till Completion Of The Project . ( Ii ) Preparation & Developing Of Preliminary/Final Architectural Design & Drawing ( Line Plan , Elevation & Sections ) Base On Plinth Area And The Same Shall Be Submitted To This Office For The Approval By This Hq . ( Iii ) After The Approval Of The Plan , The Consultant Will Prepare And Submit Structural Designs And Drawings In Auto-Cad For The Above Mentioned Buildings As Per Sound Architectural Practices ( Confirming Basic Code , Provisionss And Other Bldg Bye Laws As Nbc ) And As Per Area & Other Details Mentioned In The Adm Approval/As Directed By Dcwe B/R Of Hq Cwe ( Af ) Bamrauli . ( Iv ) After Approval Of The Structural Drawings , The Consultant Shall Submit The Detailed Estimates Boq Duly Priced On Ssr 2010 , Yard Stick In Requisite Format And Market Rate Analysis . ( V ) Terms And Conditions Of The Agreement Are Given In Appx A

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Apr-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-04-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: QUOTATION Job order for consultancy of Supply of Architectural, Structural Drawing & Design and preparation of BOQ estimates and rate analysis for “PROVN OF FIRE EXIT LADDER AROUND SRE BUILDING AT 17 WG GORAKHPUR ”
Item Description Item Code / Make Quantity Units
1 Supply of Architectural, structure drawing & design and preparation of BOQ estimates and rate analysis for "Provn of Fire Exit Ladder Around SRE buildings at 17 Wing.\nBrief Scope of Work\nBldg comprises the following :- \n(a) Additional stair case adjacent to existing SRE Bldg up to fifth floor. Maint stair case=6.40x3.20 =20.48 (A), connecting passage =1.20x2.50=3.00, (B) Total area plinth = (A+B)x5 (Floors) = (20.48+3.00)x5=117.40 Sqm, Say 118 Sqm\n(b) Construction of Pump House with permanent specification 4mtrx4mtr=16 Sqm\n(c) Construction of top open semi under ground sump of capacity 80kl = 01 Nos \n(d) Height of bldg from FFL- 3.60mtrx5=18 mtr (stair case), 3.2 mtr for Pump House.\n(e) Plinth ht of bldg from existing dispersal for stair case.\nBRIEF SPECIFICATION \n(a) Foundation- to be designed for RCC M-25 (design mix), (b) RCC framed structure with RCC roof slab reinforcement shall be TMT Fe 500D, \n(c) Brick wall shall be 230mm. (d) Water proofing treatment APP roof treatment. (e) Plastering Internal-15mm thk in CM 1:6 and external 15mm thk in CM 1:4. (f) Soil bearing capacity-8 T/M2 (tentative). Same to be reconfirmed from soil investigation report or soil data provided by GE. (g) Flooring & Skirting- 18-22mm th kota stone for starcase, PCC for Pump House and RCC Flooring internal for UG sump out side PQC/Hard Standing. (ii) Non-skid ceramic tiles for toilet. (iii) Glazed ceramic tiles for dado in toilet (h) Joinery Collapsible door for stair case & other pressed steel framed with factory made panelled shutter: (j) Door & Windows- Panel door with fly proofing and steel window with fly proofing and guard bar shell be provided. Curtain rods to be provided over door and window . (ii) Toilet- Pre laminated PVC door frame with shutter, (ii) Finishes external: cement base paint. Internal: white wash with primer, (k) Plinth protection: 750mm wide 75mm thk PCC 1:3:6 over 100mm thk hard core. (l) RCC M-30 for top open semi UG Sump. \nSTRUCTURAL ASPECT\nProvn of supply of strucural design drawing with sound engineering practice in Auto CAD with latest Indian Standards IS 456, IS 800, IS 816, IS 1893, IS 2062 IS 4326, IS 13920 etc, including design calculations folders alongwith STAAD output file (hard and soft copy) and one set of original tracing hard copy (A1 size) on 'Gateway brand tracing paper alongwith a soft copy of drawing. The design prepared by one designer shall be checked by another designer and both the persons shall sign in the design calculations and drawings. The drawings will be got vetted by IIT/MNIT/NIT/Govt Engg College only and duly countersigned before submission to department. \n(i) Any amendment required during tender presentation and on later during execution shall be mady by the consultant and require copies of the amended sheets shall be submitted and free of cost alongwith clarifications, if any, during complete execution till completion of the project. \n(ii) Preparation & developing of Preliminary/Final Architectural Design & Drawing (Line Plan, Elevation & Sections) base on plinth area and the same shall be submitted to this office for the approval by this HQ.\n(iii) After the approval of the plan, the consultant will prepare and submit structural designs and drawings in Auto-CAD for the above mentioned buildings as per sound Architectural practices(confirming basic code, provisionss and other bldg bye laws as NBC) and as per area & other details mentioned in the Adm approval/as directed by DCWE B/R of HQ CWE (AF) Bamrauli. \n(iv) After approval of the structural drawings, the consultant shall submit the detailed estimates BOQ duly priced on SSR 2010, Yard Stick in requisite format and market rate analysis.\n(v) Terms and conditions of the agreement are given in Appx 'A' BI01010001010000000000000515BI0100001113 1 Job