Military Engineer Services-MES has published Repair/Maint Of Water Supply Plant And Machinary , Chemical Treatment Plant Filter Plant , Rain Water Harvesting Plant , Ro Plant , Ug Sumps , Oh Reserviors Water Supply Pipe Line Raising Main , Distribution And Allied Works At Site P Afs Under Ge A. Submission Date for this Tender is 31-05-2021. Water Harvesting Tenders in THANE Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Apr-2021 | DT CORRIGENUM1 | Date | 24-04-2021 |
2 | 19-Apr-2021 | DT CORRIGENUM2 | Date | 27-04-2021 |
3 | 22-Apr-2021 | DT CORRIGENUM3 | Date | 01-05-2021 |
4 | 25-Apr-2021 | DT CORRIGENUM4 | Date | 04-05-2021 |
5 | 29-Apr-2021 | DT CORRIGENUM5 | Date | 06-05-2021 |
6 | 01-May-2021 | DT CORRIGENUM6 | Date | 10-05-2021 |
7 | 04-May-2021 | DT CORRIGENUM7 | Date | 12-05-2021 |
8 | 07-May-2021 | DT CORRIGENDUM8 | Date | 15-05-2021 |
9 | 10-May-2021 | DT CORRIGENDUM 9 | Date | 17-05-2021 |
10 | 12-May-2021 | DT CORRIGENDUM10 | Date | 19-05-2021 |
11 | 14-May-2021 | DT CORRIGENDUM11 | Date | 22-05-2021 |
12 | 17-May-2021 | DT CORRIGENDUM12 | Date | 24-05-2021 |
13 | 18-May-2021 | REVISED AND NEW PAGES UPLOADED | Other | 24-05-2021 |
14 | 24-May-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 31-05-2021 |
Name of Work: REPAIR/MAINTANENCE OF WATER SUPPLY PLANT AND MACHINARY , CHEMICAL TREATMENT PLANT FILTER PLANT, RAIN WATER HARVESTING PLANT ,RO PLANT,UG SUMPS,OH RESERVIORS WATER SUPPLY PIPE LINE RAISING MAIN, DISTRIBUTION CONTROL SYSTEM AND ALLIED WORKS AT SITE P AFS STN UNDER GE AF THANE | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Unnamed: 2 | Quantity | Units | |
1 | 1.01 | Taking up or down steel galvanized water tubing of size 40/50 mm dia with all necessary fittings complete from walls / floor or trenches including cleaning for refixing or removal to store all as directed. | 280 | RM | |
2 | 2 | All as per items no 1 here in before but size of water pipe 25mm dia. | 170 | RM | |
3 | 3 | All as per items no 1 here in before but size of water pipe 20 mm dia. | 170 | RM | |
4 | 4 | All as per items no 1 here in before but size of water pipe 15 mm dia. | 120 | RM | |
5 | 5 | Supply & fixing GI steel tubings of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors of size 15mm dia all as directed. | 100 | RM | |
6 | 6 | All as per items no 5 here in before but size of water pipe 20mm dia. | 150 | RM | |
7 | 7 | All as per items no 5 here in before but size of water pipe 25 mm dia. | 150 | RM | |
8 | 8 | All as per items no 5 here in before but size of water pipe 40 mm dia. | 150 | RM | |
9 | 9 | All as per items no 5 here in before but size of water pipe 50 mm dia. | 100 | RM | |
10 | 10 | Refixing old steel tubing of size 40/50mm and connections including fitting/fixture in new or old position, walls / floor or trenches including cleaning all as directed. | 30 | RM | |
11 | 11 | All as per items no 10 here in before but size of water pipe 25mm dia. | 20 | RM | |
12 | 12 | All as per items no 10 here in before but size of water pipe 20 mm dia. | 20 | RM | |
13 | 13 | All as per items no 10 here in before but size of water pipe 15 mm dia. | 20 | RM | |
14 | 14 | M&L for cutting existing steel tubing for alterations or additions of pipes size 20mm bore all as directed | 10 | Each | |
15 | 15 | M&L for cutting existing steel tubing for alterations or additions of pipes size 25 mm bore all as directed | 10 | Each | |
16 | 16 | M&L for cutting existing steel tubing for alterations or additions of pipes size 40/50 mm bore all as directed | 10 | Each | |
17 | 17 | M&L for cutting existing steel tubing for alterations or additions of pipes size 80/100 mm bore all as directed | 3 | Each | |
18 | 18 | M&L for Screwing existing steel tubing for alterations or additions of pipes size 20mm bore all as directed | 10 | Each | |
19 | 19 | M&L for Screwing existing steel tubing for alterations or additions of pipes size 25 mm bore all as directed | 10 | Each | |
20 | 20 | M&L for Screwing existing steel tubing for alterations or additions of pipes size 40/50 mm bore all as directed | 5 | Each | |
21 | 21 | Taking up the unserviceble gate valve of any type and Supply and fixing the Gate valve 15 mm bore dia. Gun-metal, gate valves, with iron wheel head, screwed both ends on G.I pipes with GI union, including removing old unserviceable ones all as per directed.. | 10 | Each | |
22 | 22 | All as per items no 21 here in before but size of water pipe 20mm dia all as directed. | 10 | Each | |
23 | 23 | All as per items no 21 here in before but size of water pipe 25 mm dia all as directed.. | 10 | Each | |
24 | 24 | All as per items no 21 here in before but size of water pipe 40 mm dia all as directed.. | 10 | Each | |
25 | 25 | All as per items no 21 here in before but size of water pipe 50 mm dia all as directed.. | 5 | Each | |
26 | 26 | Taking up or down Ductil /Cast Iron water mains( Including all fittings) with spigot and socket ends and lead joint/rubber joints complet of size 150 mm for repair and reconnect all as directed. | 100 | RM | |
27 | 27 | Taking up or down Ductil /Cast Iron water mains( Including all fittings) with spigot and socket ends and lead joint/rubber joints complet of size 100 mm for repair and reconnect all as directed. | 30 | RM | |
28 | 28 | Taking up or down Ductil /Cast Iron water mains( Including all fittings) with spigot and socket ends and lead joint/rubber joints complet of size 80 mm for repair and reconnect all as directed. | 30 | RM | |
29 | 29 | Supply & laying DI pipe of 150 mm bore diameter, Class K-9 special complete in same trench or new route or on brick pillar as per site requirenmentall as specified and directed by Engineer-in -Charge.NOTE- (a) After laying the pipe damaged of road/hard standing /tilling to be make as good as existing condition at no extra cost. | 100 | RM | |
30 | 30 | Supply & laying DI pipe of 100 mm bore diameter, Class K-9 special complete in same trench or new route or on brick pillar as per site requirenmentall as specified and directed by Engineer-in -Charge.NOTE- (a) After laying the pipe damaged of road/hard standing /tilling to be make as good as existing condition at no extra cost. | 30 | RM | |
31 | 31 | Supply & laying DI pipe of 80 mm bore diameter, Class K-9 special complete in same trench or new route or on brick pillar as per site requirenmentall as specified and directed by Engineer-in -Charge.NOTE- (a) After laying the pipe damaged of road/hard standing /tilling to be make as good as existing condition at no extra cost. | 30 | RM | |
32 | 32 | Taking up unserviceable CI sluice valve of size 150mm ,including nuts,bolts,packing complet all as directed. | 6 | Each | |
33 | 33 | Taking up unserviceable CI sluice valve of size 100mm ,including nuts,bolts,packing complet all as directed. | 3 | Each | |
34 | 34 | Taking up unserviceable CI sluice valve of size 80mm ,including nuts,bolts,packing complet all as directed. | 3 | Each | |
35 | 35 | Supply & Fixing sluice valve 150mm dia of any type and providing suitable size of nuts and bolts, washer complet all as directed. | 6 | Each | |
36 | 36 | Supply & Fixing sluice valve 100mm dia of any type and providing suitable size of nuts and bolts, washer complet all as directed. | 3 | Each | |
37 | 37 | Supply & Fixing sluice valve 80mm dia of any type and providing suitable size of nuts and bolts, washer complet all as directed. | 3 | Each | |
38 | 38 | Supply & Fixing only JP Jointsuitable for 150mm dia pipe line including providing suitable size of nuts and bolts, washer complet all as directed. | 3 | Each | |
39 | 39 | Supply & Fixing only JP Jointsuitable for 100mm dia pipe line including providing suitable size of nuts and bolts, washer complet all as directed. | 3 | Each | |
40 | 40 | Supply & fixing in replacement unserviceable Butterfly valve of size 150m fixing only the Butterfly valve of size 150mm ,including nuts,bolts,packing complete all as directed. | 3 | Each | |
41 | 41 | Supply & fixing in replacement unserviceable Butterfly valve of size 100m fixing only the Butterfly valve of size 150mm ,including nuts,bolts,packing complet all as directed. | 1 | Each | |
42 | 42 | Supply & fixing in replacement unserviceable Butterfly valve of size 80m fixing only the Butterfly valve of size 150mm ,including nuts,bolts,packing complet all as directed. | 1 | Each | |
43 | 43 | Excavation in trenches n. exc1.5 mtr wide and n.exc. 1.50 mtr depth for laying of pipe or other works and getting out in soft /loose soil all as directed. | 250 | CUM | |
44 | 44 | Returning filling in excavated soil including spreading leveling and well ramming in layers n. exc 25 cm each any type of soil. | 190 | CUM | |
45 | 45 | Removing the excavated materials not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as directed by Engineer-in-Charge | 60 | CUM | |
46 | 46 | M&L for cutting into the existing road/hard standing surfaces to a depth of 60cm and 50cm wide and getting out for laying under ground cable including returning filling in, watering, well ramming in layers not exceeding 25cm in any type of soil and filling the top surface with 15cm thick with PCC 1 : 2 : 4 type B1 using 20mm graded stone aggregate and finished even and fair without using extra cement including disposal of surplus soil all as directed by Engineer in charge. | 10 | RM | |
47 | 47 | Material and labour for CI/DI Special like bends, Tees, collar, Tail piece etc (any type & shape and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for DI pipe upto 150 mm dia. | 80 | Kgs | |
48 | 48 | Material and labour for DI pipe rubber gasket suitable for 150mm K-7/K-9 pipe all as directed. | 20 | Each | |
49 | 49 | Material and labour for DI pipe rubber gasket suitable for 100mm K-7/K-9 pipe all as directed. | 6 | Each | |
50 | 50 | Material and labour for DI pipe rubber gasket suitable for 80mm K-7/K-9 pipe all as directed. | 6 | Each | |
51 | 51 | Supply and providing pipe fitter with helper for attending the brackdown of DI/CI water sypply pipe line up to 80/100 mm dia pipe line. Note: (a)Necessary pipe,fitting,excavation will be measured in respective items. (b) Necessary tools,ladder or providing stagging will be arrange by the contractor in his own cost. | 10 | Each Job | |
52 | 52 | All as per item no- 51 here in above but size150 mm bore diameter pipe line. | 10 | Each Job | |
53 | 53 | Supply and providing pipe fitter with helper for attending the brackdown of GI water sypply pipe line up to 80/100 mm dia pipe line. Note: (a)Necessary pipe,fitting,excavation will be measured in respective items all as directed. (b) Necessary tools,ladder or providing stagging will be arrange by the contractor in his own cost. | 6 | Each Job | |
54 | 54 | All as per item no- 53 here in above but size 50 mm/40mm bore diameter pipe line all as directed. | 10 | Each Job | |
55 | 55 | All as per item no- 53 here in above but size 25 mm/20/15 mm bore diameter pipe line all as directed. | 10 | Each Job | |
56 | 56 | Supply & fix Cross arms,bracings,supports,clamps and back plates,fabricated from structural steel sections including nuts,bolts,washers,welding,bending,cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as directed.MS nut and bolt including washer suitable for fixing sluice valve all as specified and directed. | 0.5 | Per Qntl | |
57 | 57 | Supply. testing ,installation & fixing in replacement of 100 mm dia water meter with flanged joints;including removal of flanged connecting piece, or blank flange (if required) or taking out meter for testing, etc., and fixing a length of flanged connecting pipe (or two blank flanges) and labour only for two flanged joints. | 1 | Each job | |
58 | 58 | Taking up unserviceable non return valve (NRV) and supply with fittings 150 mm dia cast iron non return(reflux) valve with flanged ends Non return with GM working parts IS-5312 heavy duty , drilled for bolts, including necessary rubber gasket joint complete with nuts and boltscomplete all as specified and directed by Engineer-in-Charge | 2 | Each | |
59 | 59 | All as per item No 58 here in before but size of water pipe 100 mm dia all as specified, | 1 | Each | |
60 | 60 | All as per item No 58 here in before but size of water pipe 80 mm dia all as specified, | 2 | Each | |
61 | 61 | Supply only Grade IV ferric alum suitable for drinking water all as directed. | 250 | KG | |
62 | 62 | Supply only Altoch GP (calcuim based granular hypochloride for water treatment packed in 45 Kgs Plastic Drum) complete all as specified and directed by Engineer-in-charge | 225 | KG | |
63 | 63 | Material labour and services for taking sample water in sterlised bottles from water supply point, UG Sump / OH Resorvier for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories:\n(i) Physio Chemical Analysis of Water ( Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride)\n(ii) Microbiological Analysis ( Total Choliforms , Eschirrchea Coli) \nNote : \n1. A certificate of approval / certification of Lab by Goivt Of India / State Govt shall be submitted by the contractor to the deptt. \n2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample \n3. Three samples will be checked in each job \n | 3 | Each Job | |
64 | 64 | M&L for Cleaning of underground RCC sump of capacity 50000 gallon with the following process . \n(i) Dewatering the sump by using submersible and sludge pump which empty the tank up to base level . \n(ii) High pressure jet cleaning:- Cleaning of manhole of the tank, inside wall/ceiling of RCC sump with the help of high pressure rotary jet (Dirt killer) of capacity variable pressure 50-140 bars to remove the calcination (Fungal) layer. (iii) Removing sludge from the tank:- The sludge and infection removed from walls, Ceiling & bottom of the tank have to be remove with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom of the tank have to be sucked with special Industrial Vaccum cleaner. So that the tank is totally dirt free. (iv) Disinfection of the tank:- Cleaning of walls/ceiling with fresh water and biodegradable anti bacterial agent. \n(v) Sterilization of the tank:- After complete cleaning apply ultraviolet sterilizer having a Virocidal wavelength to ensure perfect disinfection of the tank | 5 | Each Job | |
65 | 65 | All as per item no-64 here in above but capacity of Under ground sump 1,00,000 Glns capacity | 2 | Each | |
66 | 66 | Repair of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed. | 6 | Each job | |
67 | 67 | Repair of brick massonry valve pit chamber of inner dimension 50x50x500 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed. | 2 | Each job | |
68 | 68 | Earthing complete with copper earth plate electrode of size 600 x 600 x 3 mm buried directly in ground (earthpit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level,connected to & including copper earth strip of size 20x3 mm dia by means of GI bolts,nuts, washers and connected to other end to main boardduly protected by 15 mm bore GI light grade pipe from earth plate . Earth plate shall be surrounded by packed layer of coal dust 300 mm and common salt 15 cm thick all around bottom and top. Watering pipe 20mm bore of GI medium grade pipe and including funnel, wire mesh,CI cover & frame, PCC (1:3:6) type C2 (using 40 mm garded stone aggregate) as in earthing pit including necessary excavation & earth work all as specified & shown in electrical plate No 5 of SSR-I .Rate are deemed to include 7.5 mtr 20 x 3 mm size copper strip. NOTE:- PCC/HDPE chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting manner . (ii) Earth resistance of earth pit should be less than 2 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & charcoal upto & above 450 mm top of copper plate. (iv) Soil resitance test if required shall be responsbility of contractor without any extra cost. | 3 | Each | |
69 | 69 | Supply and fix in replacement of copper strip of 20x3 mm as roof conductor and down conductor till test point all as specified and directed. Note - Copper sstrip to be jointed through brazing. | 20 | RM | |
70 | 70 | M&L for Cleaning of RCC over head tank of capacity 25000 gallon with the following process . \n(i) Dewatering the sump by using submersible and sludge pump which empty the tank up to base level . \n(ii) High pressure jet cleaning:- Cleaning of manhole of the tank, inside wall/ceiling of RCC sump with the help of high pressure rotary jet (Dirt killer) of capacity variable pressure 50-140 bars to remove the calcination (Fungal) layer. (iii) Removing sludge from the tank:- The sludge and infection removed from walls, Ceiling & bottom of the tank have to be remove with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom of the tank have to be sucked with special Industrial Vaccum cleaner. So that the tank is totally dirt free. (iv) Disinfection of the tank:- Cleaning of walls/ceiling with fresh water and biodegradable anti bacterial agent. (v) Sterilization of the tank:- After complete cleaning apply ultraviolet sterilizer having a Virocidal wavelength to ensure perfect disinfection of the tank | 2 | Each | |
71 | 71 | M&L for Cleaning of RCC over head tank of capacity 50000 gallon with the following process . \n(i) Dewatering the sump by using submersible and sludge pump which empty the tank up to base level . \n(ii) High pressure jet cleaning:- Cleaning of manhole of the tank, inside wall/ceiling of RCC sump with the help of high pressure rotary jet (Dirt killer) of capacity variable pressure 50-140 bars to remove the calcination (Fungal) layer. (iii) Removing sludge from the tank:- The sludge and infection removed from walls, Ceiling & bottom of the tank have to be remove with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom of the tank have to be sucked with special Industrial Vaccum cleaner. So that the tank is totally dirt free. (iv) Disinfection of the tank:- Cleaning of walls/ceiling with fresh water and biodegradable anti bacterial agent. (v) Sterilization of the tank:- After complete cleaning apply ultraviolet sterilizer having a Virocidal wavelength to ensure perfect disinfection of the tank | 2 | Each | |
72 | 72 | Repair/servicing including renewal / replacement of defective parts, servicing/cleaning and checking for any defects for automotion of water pumping installation and kept it in 100% serviceable condition at all times. And carry out under mention works at pump house of AF station thane a) Testing ,Checking and setting if required duty cycle for operation of pumps and set cycles as per pumping timings of installation b) Check of PLC Panels display , for in auto manual operation of Pumps , valve , Actuatoers c)Checking of Push button , ON -OFF switch , Selector switch on PLC Panels for various mode of operation d)checking all the connection of communication cables inside the PLC Panels and at end termination for any damge or Loose connection .e) Checking of Preesure switch , Solenoid valves , water level sensor for their healty operation of Automation system f) Checking of MIMIC Panels for for proper display of water level indication of water level in sump and over head tank .g) Checking of all butter fly valves for smooth operation and water lekage h) Chekcing of PLC realy for healty operation and carry necessary setting if required I) Cheking of moter for smooth operation of actuater and operating mechanisum of butter fly valves J) Checking auto Priming system operation for priming of Pumps | 11 | Month | |
73 | 73 | Servicing of Pressure Switch i.e Cleaning, checking for wear and tear, checking electrical termination and testing as directed by the Engineer-In-Charge.\nNote: Spares if needed is not included in this item. | 6 | Each | |
74 | 74 | Servicing of Solenoide Valve - 10mm/15mm. dia. i.e Removing, Cleaning, Greasing, checking for wear and tear, checking electrical termination and testing as directed by the Engineer-In-Charge.\nNote: Spares if needed is not included in this item. | 5 | Each | |
75 | 75 | Servicing of Magnetic Level Sensor i.e. Cleaning, checking for wear and tear, checking electrical termination and testing as directed by the Engineer-In-Charge.\nNote: Spares if needed is not included in this item. | 10 | Each | |
76 | 76 | Servicing of Motorized Valve of size 80/100/150mm. dia. i.e Removing, Cleaning, Greasing, checking for wear and tear, checking electrical termination and testing as directed by the Engineer-In-Charge.\nNote: Spares if needed is not included in this item. | 5 | Each | |
77 | 77 | Servicing of Butterfly Valve of size 80/100/150mm. dia. i.e Removing, Cleaning, Greasing, checking for wear and tear, checking electrical termination and testing as directed by the Engineer-In-Charge.\nNote: Spares if needed is not included in this item. | 5 | Each | |
78 | 78 | Supply & Fixing of Single Phase Electric Actuator suitable for 150mm. dia. Butterfly valve with disc material of CI with nylon coating, hand wheel for manual operation, Pressure rating of 10 kg/sq cm and having 02 nos. limit switches for Open/Close condition, valve position indicator. \nMake: Marsh/Emtork/Rotork | 2 | Each | |
79 | 79 | Supply & Fixing of Electric Motor for Actuator suitable for 80mm. dia. Butterfly valve.\nMake: Synchrotec/Marsh/Emtork | 1 | Each | |
80 | 80 | Supply & Fixing of Electric Motor for Actuator suitable for 150mm. dia. Butterfly valve.\nMake: Synchrotec/Marsh/Emtork | 1 | Each | |
81 | 81 | Supply & Fixing of Limit Switch for Actuator suitable for 80/100/150mm. dia. Butterfly valve. | 4 | Each | |
82 | 82 | Supply & Fixing of Capacitor for Actuator suitable for 80/100/150mm. dia. Butterfly valve. | 3 | Each | |
83 | 83 | Supply & Fixing of Resistor for Actuator suitable for 80/100/150mm. dia. Butterfly valve. | 3 | Each | |
84 | 84 | Supply & Fixing of Hand Wheel for Actuator suitable for 80/100/150mm. dia. Butterfly valve. | 3 | Each | |
85 | 85 | Supply & Fixing of Magnetic Level Sensor.\nMake: Yogitech/Mahalaxmi/Techsolution | 5 | Each | |
86 | 86 | Supply & Fixing of Water Level Controller (WLC) relay card (05 Level)\nMake: ME/Sai Electrical or Equivalent | 7 | Each | |
87 | 87 | Supply & Fixing of Push Button with LED indicator - 240V AC.\nColor: Red/Yellow/Green.\nMake: Telemecanique/Schneider/Esbee | 10 | Each | |
88 | 88 | Supply & Fixing of LED indicator - 240V AC. Color: Red/Yellow/Green.\nMake: Telemecanique/Schneider/Esbee | 10 | Each | |
89 | 89 | Supply & Fixing of Selector Switch. (2/3 position)\nMake: Telemecanique/Schneider/Esbee | 4 | Each | |
90 | 90 | Supply & Fixing of SMPS - 24V DC/5 A\nMake: Telemecanique/NHP/L & T | 1 | Each | |
91 | 91 | Supply & Fixing of 5 pair 0.5mm. dia. armoured copper cable for sensor. \nMake: Havells/Nicco/Plaza/Polycab | 55 | RM | |
92 | 92 | Supply & Fixing of 2 Core 1.5 sq.mm. PVC sheath, PVC insulated, copper, armoured cable. Make: Havells/Nicco/Plaza/Polycab | 25 | RM | |
93 | 93 | Supply & Fixing of 4 Core 1.5 sq.mm. PVC sheath, PVC insulated, copper, armoured cable. Make: Havells/Nicco/Plaza/Polycab | 35 | RM | |
94 | 94 | Supply & Fixing of 6 Core 1.5 sq.mm. PVC sheath, PVC insulated, copper, armoured cable. Make: Havells/Nicco/Plaza/Polycab | 80 | RM | |
95 | 95 | M&L for overhauling of pump sets of capacity 18.5 KW/25 HP by repair to shaft with metal filling, grinding, machining, finishing and aligning to reqd size and replacing of UNSV nuts, bolts and washers of exisitng/approved make and type including refixing/commissioning at site complete all as directed. | 3 | Each Job | |
96 | 96 | Supply only the following spare parts to incorporate under Sl no 42 all as per existing approved make & Type:- | |||
97 | 97 | (a) Bearing suitable for 25 HP pump set/Motor make : SKF. | 6 | Each | |
98 | 98 | (b) Coupling CI as reqd at site suitable for 25 HP Pump set as per sample | 3 | Per Set | |
99 | 99 | (c) Gland bushing as reqd at site suitable for 25 HP Pump set as per sample. | 2 | Each | |
100 | 100 | (d) Cooling fan suitable for 25 HP motor | 2 | Each | |
101 | 101 | M&L Rewinding of motor of centrifugal pump set capacity 18.5 KW/25 HP by using super enamelled copper wire of suitable gauge to match with the existing including varnishing, drying,and replacement of UNSV parts of existing size/approved make such as bearing of appropriate size, nuts, bolts and washers, packing , etc complete all as directed. | 2 | Each Job | |
102 | 102 | M&L in replacement Automatic Star delta starter suitable for 25 HP, 3 Phase, 415 Volts motor including testing and commissioning all as directed of Make: Siemens/L&T/Havells | 1 | Each | |
103 | 103 | M&L in replacement of contactor 3 pole,32 Amps 415 Volts suitable for 25 HP Auto Star Delta Starter | 3 | Each | |
104 | 104 | M&L in replacement of Overload Relay of range 16 to 22 amps suitable for 3 Phase 25 HP Auto Star Delta Starter | 4 | Each | |
105 | 105 | M&L in replacement of Single phase preventor | 3 | Each | |
106 | 106 | M&L in replacement of timer switch for 3 Phase 25 HP Auto Star Delta Starter | 3 | Each | |
107 | 107 | Repair/ and servicing including renewal / replacement of defective parts, servicing/cleaning and checking for any leakage etc to keep chlorination doser plant 100% serviceable at all times. The plant comprise of complete filled chlorine doser tank of 50 ltrs and 100 ltrs capacity, injector assembly, chlorine liquid pvc pipe assembly,wall mounted and liquid chlorine dozing pump having discharge capacity of 10 ltr/hr chlorine liquid at the Pump house of AF Station thane | 4 | Each Job | |
108 | 108 | Repairing, servicing, cleaning and checking choloring dozing pump and connected design motor, service tank, preparation tank complete system for choloration under water pumping installation and kept it in 100% serviceable condition at all times in and carry out under mention works at AF station thane.\n(a) Testing, checking and setting if required duty cycle for operation of chlorine dozing pump and set cycles as per design rate 10ltr/hr\n(b) Cleaning the preparation tank of capacity 100ltrs\n(c ) Cleaning the water inlet line\n(d) Cleaning the outlet with strainer\n(e) Cleaning the drainage system\n(f) Cleaning the conical bottom of sludge deposition\n(g) Cleaning the pot hole with cover\n(h) Cleaning the level gauge\n(i) Servicing the agitator 120 watt 900rpm 1 phase flange mounted motor with plastic shaft and impeller of Magnetic Level Sensor i.e. Cleaning, checking for wear and tear, checking electrical termination and testing as directed\n(j) The servicing to be done in each month\n(k) Necessary spare for repair to be measured and paid separately in respective items | 11 | Per month | |
109 | 109 | Supply the pump tube for dozing pump with nozzle and necessary fittings suitable for liquid chlorine dozer. Make:-Sathya Sai Aqua Pure Services or equivalent or equivalent | 6 | Each | |
110 | 110 | Supply the suction/discharge tube(3/8") white for dozing pump.Make:-Sathya Sai Aqua Pure Services or equivalent or equivalent | 20 | RM | |
111 | 111 | Supply the injection check valve(3/8" connection) for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent or equivalent | 2 | Each | |
112 | 112 | Supply the foot valve (clay weight-3/8" connection) for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent or equivalent | 4 | Each | |
113 | 113 | Supply the duck bill for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 4 | Each | |
114 | 114 | Supply the motor 220V 50Hz for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 2 | Each | |
115 | 115 | Supply the ferrul for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 4 | Each | |
116 | 116 | Supply the pump head complete for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 1 | Each | |
117 | 117 | Supply the feed rate controller for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 2 | Each | |
118 | 118 | Supply the valve "O" ring for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 6 | Each | |
119 | 119 | Supply the rotor assembly with bearing bracket etc for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 2 | Each | |
120 | 120 | Supply the coil for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 1 | Each | |
121 | 121 | Supply the roller assembly for dozing pump. Make:-Sathya Sai Aqua Pure Services or equivalent | 5 | Each | |
122 | 122 | Taking up unserviceable foot valve of any type after necessary disconnection of suction pipe and supply and fixing gunmetal foot valve of size 100mm bore | 2 | Each |