Supply Erection Testing And Commissioning Of New 30Mtr Hot Dipped Galvanized High Mast Pole With 350Watt Led Flood Light And Repair With Replacement And Fixing Of 350Watt Led Fixture Power Cable And Panel At 30Mtr Of 9Nos Existing High Mast Of Rsp, Rudri-Chhattisgarh

Water Resources Department-WRD has published Supply Erection Testing And Commissioning Of New 30Mtr Hot Dipped Galvanized High Mast Pole With 350Watt Led Flood Light And Repair With Replacement And Fixing Of 350Watt Led Fixture Power Cable And Panel At 30Mtr Of 9Nos Existing High Mast Of Rsp. Submission Date for this Tender is 28-06-2021. Halogen Light Tenders in Rudri Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

27543532
Corrigendum : Supply Erection Testing And Commissioning Of New 30Mtr Hot Dipped Galvanized High Mast Pole With 350Watt Led Flood Light And Repair With Replacement And Fixing Of 350Watt Led Fixture Power Cable And Panel At 30Mtr Of 9Nos Existing High Mast Of Rsp
Open Tender
Indian
Chhattisgarh
Rudri
28-06-2021

Tender Details

Supply Erection Testing And Commissioning Of New 30Mtr Hot Dipped Galvanized High Mast Pole With 350Watt Led Flood Light And Repair With Replacement And Fixing Of 350Watt Led Fixture Power Cable And Panel At 30Mtr Of 9Nos Existing High Mast Of Rsp

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Apr-2021 Corrigendum 1 Technical Bid 20-05-2021
2 05-May-2021 Corrigendum 3 Date 10-06-2021
3 31-May-2021 corrigendum 4 Date 28-06-2021
4 15-Jun-2021 Corrigendum 5 attachment Other 28-06-2021

Key Value

Document Fees
INR 2000 /-
EMD
INR 83000.0 /-
Tender Value
INR 1.10 Crore /-

BOQ Items

Name of Work: : Supply erection testing & commissioning of new 30mtr Hot dipped galvanized high mast pole with 350watt LED flood light and repair with replacement and fixing of 350watt LED fixture power cable and panel at 30mtr of 9 nos existing high mast of RSP Gangrel Dam.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in hard rock including controlled blasting permitted 50m lead and 1.5 m lift with lead, lift, cost of all materials, arrangement, transportation and labour charges etc. as per specification of water resources department and as directed by engineer – in – charge . code1 120 cum
2 2 Designing and providing suitable and approved size RCC foundation Size of - 3800 mm x2300 mm x1100mm for 15-30 meter high mast including steel reinforcement (minimum 90 kg per cum.), from work, embedding 2 nos. 50 mm dia PVC pipe for cable entry in each foundation excavation disposal of surplus soil and curing etc. as required including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as required. with lead, lift, cost of all materials, arrangement, transportation and labour charges etc. as per specification of water resources department and as directed by engineer – in – charge . code2 30.52 cum
3 3 Supplying, erection, testing, and commissioning of hot dipped galvanized(single dipped 86 micron) 30 meter high mast pole on existing RCC foundation with all accessories and equipments. detailed as below to with stand wind pressure up to 180 km/hrs and minimum following specification and IS0-1461 with reputed and approved make. A.      HM shaft made of not more than 3 section of suitable lengths with telescopic stress fit joints between sections without any circumpherencial welding, sheet thickness 4 mm top ,middle and bottom section, nominal dia 600 mm on bottom and 150 mm on top base base plate 32 mm thick 840 mm dia PCD of foundation bolts 740 mm B .Double drum which for lowering & raising of lantern carriage on high mast with opratable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage. C. Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box.D. Top pulley assembly with weather proof cover E. 3Nos. suitable length and size stainless steel wire ropes (minimum 6 mm dia and 7/19 construction) for lowering & rising of lantern carriage. F. Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm) G. Hinged service door in base section.H. Base plate earthing terminal. I. Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast.J. Lighting conductor final made of 25 mm dia 300 mm long GI tube having K Anchor plate of size 840 mm x840 mm x6 mm ,ten plates 3 mm thick GI foundation bolts 16 nos.of 30 mm dia 850 mm long (EN 8 Grade) along with washers etc. (RCC Foundation and luminaries will be paid separately) with lead, lift, cost of all materials, arrangement, transportation and labour charges , Test and Trail etc. as per specification of water resources department and as directed by engineer – in – charge code3 4 each
4 4 Supplying and Laying of 120 Sqmm,1100volts, grade 3.5 Core PVC insulated heavy duty armoured cables (conforming to IS 1554-1964) of approved make in existing prepared trench with lead, lift, cost of all materials, arrangement, transportation and labour charges, etc. as per specification of water resources department and as directed by engineer – in – charge . code4 1875 M
5 5 Supplying and Laying of 35 Sqmm ,1100 Volts, grade 3.5 core PVC insulated heavy duty armoured cables (conforming to IS 1554-1964) of approved make in existing prepared trench with lead, lift, cost of all materials, dismantling cable deposited to E/M store, arrangement, transportation and labour charges, etc. as per specification of water resources department and as directed by engineer – in – charge . code5 2800 M
6 6 Supplying and fixing of outdoor stand mounted feeder piller with 63 amp TPN MCB Incomer, bus bar neutral link, din bar suitable for incorporating M.C.B. surface /flush mounting type. single dial time switch 45 A TP contactor for the automatic switching of luminaries, power tool control with 2 no. 9A contactors and raise lower push button, incoming 35 sqmm and outgoing 16&25 sqmm terminals, as per latest ISO and IEC 60898 with reputed and approved make with lead, lift, cost of all materials, dismantling electrical accessories deposite to E/M store, arrangement, transportation and labour charges, etc. as per specification of water resources department and as directed by engineer – in – charge . code6 13 each
7 7 Supplying, installation, testing and commissioning of 350 watt LED flood light luminaries extruded aluminum heat sink, designed to act as efficient heat dissipater important for LED luminaries, pressure die cast aluminum cover on both sides for holding of extruded aluminum heat sink, luminaries provided with heat resistance toughened glass,, LEDs are provided with secondary lens optics to get optimum optical performance, Luminaries is provided with a mounting bracket fixed on pressure die cast aluminum cover for aiming adjustment, IP 66 with 5KV Internal &10KV external surge protection as per specification and IS-10322,Part -5/SEC-1:2012 certification mark and reputed and approved make with lead, lift, cost of all materials, dismantling old MH light fixture deposite to E/M store, arrangement, transportation and labour charges, etc. as per specification of water resources department and as directed by engineer – in – charge. code7 156 NO
8 8 Providing and fixing of 200 amp 3 phase 4 way water tight junction box (Bus Bar) made of 1.6 mm thick MS sheet with detachable, gland plate in bottom hinged front open able ,rubber gasket, heavy 4 No. tinned copper bus bar as per specification, with latest ISO Code and as per IEC-60898. including fixing with 50mm x50mmx5mm angle iron frame with duly embedded in masonry including cable connection and other required material complete with lead, lift, cost of all materials, dismantling old MH light fixture deposite to E/M store, arrangement, transportation and labour charges, etc. as per specification of water resources department and as directed by engineer – in – charge code8 7 NO
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail