Numaligarh Refinery Limited has published Erection/Installation Of Odc/Owc Including Multimodal Transportation From Haldia Port/Kolkatta Port To Nrl Site. Submission Date for this Tender is 28-06-2021. Reactor Tenders in Numaligargh Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Apr-2021 | CORRIGENDUM 1 | Date | 20-05-2021 |
2 | 30-Apr-2021 | Corrigendum 2 | Date | 10-06-2021 |
3 | 30-Apr-2021 | Corrigendum 3 | Other | 10-06-2021 |
4 | 20-May-2021 | Corrigendum 4 | Other | 10-06-2021 |
5 | 21-May-2021 | Corrigendum 5 | BOQ | 10-06-2021 |
6 | 22-May-2021 | Corrigendum 6 | Other | 10-06-2021 |
7 | 04-Jun-2021 | Corrigendum 7 | Date | 28-06-2021 |
Name of Work: ERECTION/INSTALLATION OF ODC/OWC INCLUDING MULTIMODAL TRANSPORTATION FROM HALDIA PORT /KOLKATA PORT TO NRL SITE at Numaligarh Refinery Limited | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Transport Engineering and design of Bridge Jumper/Structural at Kaliyani River Crossing(refer scope of work Part-A) | |||
2 | 1.01 | Design the most suitable SPMT configuration for transportation of the aforementioned study subjects, based on the inputs from route survey and design the most suitable SPMT configuration for each type of cargo. Once the design is identified, create transport drawing of the ODC/OWC\nThis design will, at minimum, achieve the axle-load below 15Te/axle due to the road condition.Design the bridge jumper/Structural arrangement for an approximate 75mtr-wide Kaliyani River (bidder to survey at site for the actual width) .This is the only major river crossing of this route. \nSpecify the requirement of the piers for bridge jumper. prepare and submit bridge drawing for bridge jumper/structural girder over across Kaliyani River. Provide a drawing including loads on each piers, nos. of piers, spacing of Piers, size of piers and other technical inputs required for further design and construction of civil structure / piers for supporting the bridge jumper/structural members. Submission of GA drawing of the bridge jumper/Structural configuration.\nNos. of piers shall be minimum as far as possible in view of probable river water flow obstruction during monsoon. Effort shall be to design with two piers. In any case number of piers shall not exceed 03 excluding two abutments.\n(Construction of Approach road on the both sides of the rivers shall be in the scope of NRL) | item1 | 1 | Lump Sum |
3 | 2 | Jetty development works (refer scope of work Part-A) | |||
4 | 2.01 | Jetty modification, New basuin/new jetty construction (if required), modification/construction of facilities required at jetty for performing Ro-Ro- operation,other peripherial job in jetty other than hard stand and approach road . | item2 | 1 | Lump Sum |
5 | 3 | Supply, Erection & dismantling of Bridges | |||
6 | 3.01 | Erection & dismantling of Bridge jumper /structure including supply of bridge jumper/structural member, girder.( refer scope work Part-A) | item3 | 1 | Lump Sum |
7 | 4 | Re-Erection and dismantling of Bridges | |||
8 | 4.01 | Subsequent erection & dismantling of Bridge jumper /structures ( refer scope work Part-A) | item4 | 2 | Lump Sum |
9 | 5 | Taking delivery of ODC/OWC on the river barges from supplier's vessel hook at Haldia Port / Kolkata port , Marine transportation/ water ways transportation, NRL Jetty RO-RO operation, Temporary storage, road transportation , transport inside refinery till erection location at respective NREP units(refer scope of work Part-A) | |||
10 | 5.01 | 1P31-CC-0126 : RPTU HP H2S Absorber 25M (L) x 3.2M (D) x 430MT (Weight) | item5 | 1 | Lump Sum |
11 | 5.02 | 1P30-RB-2221: RPTU EB Reactor 43.0M (L) x 4.76M (D) x 970MT (Weight) . Additional packets of Reactor Internal and Spares Net Weight :100 MT | item6 | 1 | Lump Sum |
12 | 5.03 | 1P30-RB-2222: RPTU EB Reactor 43.0M (L) x 4.75M (D) x 950MT (Weight). Additional Packets of Reactor Internal and spares Net Weight :100MT | item7 | 1 | Lump Sum |
13 | 5.04 | 1P31-RB-2821 :RPTU VGO HDT 27M (L) x 4.5M (D) x 580MT (Weight) Additional Packets of Reactor Internal and spares Net Weight :50MT | item8 | 1 | Lump Sum |
14 | 5.05 | 1P30-VV-2631 :RPTU -LCF HP/HT SEPARATOR 14.5M (L) x 4.5M (D) x 220MT (Weight) | item9 | 1 | Lump Sum |
15 | 5.06 | 1P26-RB-2521:DHT REACTOR 30M (L) x 5.6M (D) x 430MT (Weight). Additional Packets of Reactor Internal and spares Net Weight :45MT | item10 | 1 | Lump Sum |
16 | 5.07 | PFCC C3 splitter 60.0M (L) x 5.5M (D) x 400MT (Weight) | item11 | 4 | Lump Sum |
17 | 5.08 | PFCC Main Fractionator 55M (L) x 8.3M (D) x 421MT (Weight) | item12 | 1 | Lump Sum |
18 | 5.09 | PFCC Stripper 18M (L) x 10.3M (D) x 327 MT (Weight) | item13 | 1 | Lump Sum |
19 | 5.1 | 1P24-CC-0926:MSP ISOM Deisohexanizer 71M (L) x 5.4M (D) x 412 MT (Weight) | item14 | 1 | Lump Sum |
20 | 5.11 | 1P21-CC-0412: CDU Column 70M (L) x 5.6M (D) x 400MT (Weight) | item15 | 1 | Lump Sum |
21 | 5.12 | 1P21-CC-3511 :VDU Column 49M (L) x 10.3M (D) x 550MT (Weight) | item16 | 1 | Lump Sum |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail