Upgradation Of Lift At Carriappa Vihar And Intercom System At Rangpuri Under Ge ( U ) Plant And Machinery , Delhi Cantt-10, DELHI CANTT-Delhi

Military Engineer Services-MES has published Upgradation Of Lift At Carriappa Vihar And Intercom System At Rangpuri Under Ge ( U ) Plant And Machinery , Delhi Cantt-10. Submission Date for this Tender is 04-10-2021. Passenger Lift Tenders in DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

27383053
Corrigendum : Upgradation Of Lift At Carriappa Vihar And Intercom System At Rangpuri Under Ge ( U ) Plant And Machinery , Delhi Cantt-10
Open Tender
Indian
Delhi
DELHI CANTT
04-10-2021

Tender Details

Upgradation Of Lift At Carriappa Vihar And Intercom System At Rangpuri Under Ge ( U ) Plant And Machinery , Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Mar-2021 Amendment No. 1 Date 20-04-2021
2 10-Apr-2021 Amendment No 2 Date 30-04-2021
3 22-Apr-2021 Amendment No. 3 Other 30-04-2021
4 22-Apr-2021 Amendment No. 3 BOQ 30-04-2021
5 23-Apr-2021 AMENDMENT NO. 4 Date 08-05-2021
6 30-Apr-2021 Amendment No 05 Date 15-05-2021
7 07-May-2021 Amendment N0 06 Date 22-05-2021
8 07-May-2021 AMENDMENT NO 05 Other 07-08-2021
9 15-May-2021 Amendment No 07 Date 02-06-2021
10 24-May-2021 Amendment No 08 Date 12-06-2021
11 03-Jun-2021 AMENDMENT NO. 8 Date 08-07-2021
12 29-Jun-2021 Amendment No 09 Date 07-08-2021
13 31-Jul-2021 Amendment No. 10 Date 28-08-2021
14 21-Aug-2021 Amendment No. 11 Date 20-09-2021
15 11-Sep-2021 Amendment No. 12 Date 04-10-2021

Key Value

Document Fees
INR 2000 /-
EMD
INR 396000.0 /-
Tender Value
INR 3.21 Crore /-

BOQ Items

Name of Work : UPGRADATION OF LIFT AT CARRIAPPA VIHAR AND INTERCOM SYSTEM AT RANGPURI UNDER GE (U) PLANT & MACHINERY, DELHI CANTT-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Part-I (LIFT WORKS) \n(Note:- Lift works and its related works are to be executed through MOU as per clause mentioned in Schedule 'A' notes)
2 2 Dismantling of existing electric passenger lift capacity 10 Passenger/1000 kgs googs lift with simplex type selective collective control catering of basement plus six floor comprises of car cabin enclosures, lift door, AC Motor, Control Panel, Traveling Cable, Hoist Way Rope, Main Driving Sheave installed in cariappa vihar.\nNote:-(i ) contractor will making good, incase of any damage caused to surface of lift shaft & machine room during the dismantling at his own cost and no seprate payment will be made on this account for civil work as directed by Engr-in-charge\n(ii) Contractor/OEM should ensure that all safety condition/accessories as per latest IS/safety instruction on elevator are catered while quoting. Block Nos 14 to 18 passenger Lift at Carriappa Vihar, Delhi cantt. BI01010001010000000000000515BI0100001134 10 Each Job
3 3 Supply, install, testing & commissioning 10 Passengers Lift suitable to serve G+6 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories conforming to IS : 14665, simplex collective selective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system with hand set(03 Nos, one each in car & near Ground floor landing door and one in machine room).complete all as specified below and as directed:- BI01010001010000000000000515BI0100001135 5 Each
4 3.01 NOTE :-\nLift OEM to submit detailed specification/design parameters, construction drg of all components of lifts as per IS-14665 and as per latest ammendement for approval of GE before execution of work. Engr-in-Charge shall ensure that detail drg shall be forwarded to GE for approval with recommendation within one month of issue of W.O\n(a) Type of Lifts: Passenger\n(b) No. of Passengers & Load capacity: 10 Nos. & 680 Kgs \n(c) Speed: 1.5 mtr/sec with single speed motor \n(d) Power Supply : 415 volts, 3 phase AC, 50 Hz\n(e) Type of Drive: Regenerated AC variable voltage & variable frequency drive alongwith converter unit. The regenerated power shall be used to charge the battery of UPS & ARD & Emergency light.\n(f) Type of Machine: Gearless permanent magnet & directly coupled Horizontal traction machine\n
5 3.02 (g) Car size (Inside): Not less than 1.61 sqm.\n(h) Car and landing door at all floors : Automatic centre opening with VVVF door drive opening size not less than 800x2000 mm and sliding type fabricated by stainless steel sheet not less than 16 gauge having hair line finish (N-304) the car and landing doors shall be fire resistance rating of 01 hrs.\n(j) Car enclosure: manufactured with stainless steel frame not less than 16 gauge with Hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with LED light fitting complete internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill wire mesh for protection as per OEM design. \n(k) Terminal buffers: Metal special spring buffers as per manufacturer specifications. \n
6 3.03 (l) Door opening (Inside): protected by centre opening stainless steel doors with hairline finish doors with clear opening of size not less than 800x2000 mm. \n(m) Counter weight shall be of cast iron as recommended by OEM.\n(n) Car & counter weight Guide: Guide rails of `T' Section Mild steel as per OEM design.\n(o) Flooring: Aluminum chequred plate 5mm thick complete\n(p) Signals :-\n(i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floors.\n(ii) Vacuum Filled Display (LCD/VFD ) for car position indicator of stainless steel \n(iii) One No. car operating panel with Luminous buttons in car (stainless steel).\n(iv) Car direction indicator in car & Landing.\n(v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system shall be separate from ARD batteries).\n
7 3.04 (vi) Overload warning feature in car cabin.(Display and announcing type both)\n(vii) Fireman’s switch one No per lift to be installed at Ground Floor near landing door.\n(viii) All signal fixture & car operating panel on hair line stainless steel face plate with hair line finish.\n(ix) Infra red door sensor safety edge of door for entire height.\n(x) Built in announcing system with hand set(03 Nos, one each in car & near Ground floor landing door and one in machine room).\n(xi) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/exit door is open or closed.
8 3.05 (q) Stops & Opening :7( All opening on same side).\n(r) Safety device : (i) Automatic rescue device (ARD)/automatic landing device to be operating with maintenance free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of Regenerative drive.\n(ii) The ARD actuation time should be less than ten second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.\n(s) Operation: Simplex, full collective selective automatic operation with and without attendant.\n
9 3.06 (t) Machine room: Located above the hoist way .\n(u) Hoist way Constn; existing RCC structure with brick wall construction as existing at site. Total height from G/L to slab of Machine room can be seen at site.\n(v) Control system shall be closed loop type.\n(w) Door shall have ACVVVF controlled door operator.\n(x) Faceplate shape shall be Rectangular and of stainless steel in hairline finish.\n(y) Civil work : Necessary Civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc and one coat of white wash shall be applied on the lift shaft after completion of lift installation.
10 3.07 (aa) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking,connect to complete cell and provn of through & other accessories.
11 3.08 (ab) Provn of governor and governor rope of suitable size ,buffer springs as per manufacture's design,car cabin having powered doors and inspection box at top of the car cabin.
12 3.09 (ac)Provn of safety guarding equipments such as 02 Nos Pit switches controller guarding pit pulley,guarding pit ladders,facia plate to cover free space between car cabin and hoist way & switches.
13 3.1 (ad) Door sensor 81 beam,2D infra red full length .
14 3.11 (ae) provn of ''Press and Speak'' system to be connected with lift complaint cell compatible with exchange.
15 3.12 (af)Do's & Don'ts chart on stainless steel to be installed inside the car cabin.
16 4 Supply, install, testing & commissioning 1000 kgs goods Lift suitable to serve G+6 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories conforming to IS : 14665, simplex collective selective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system with hand set(03 Nos, one each in car & near Ground floor landing door and one in machine room).complete all as specified below and as directed:- BI01010001010000000000000515BI0100001136 5 Each
17 4.01 NOTE :-\nLift OEM to submit detailed specification/design parameters, construction drg of all components of lifts as per IS-14665 and as per latest ammendement for approval of GE before execution of work. Engr-in-Charge shall ensure that detail drg shall be forwarded to GE for approval with recommendation within one month of issue of W.O\n(a) Type of Lifts: Passenger\n(b) No. of Passengers & Load capacity: 1000 kgs \n(c) Speed: 1.5 mtr/sec with single speed motor \n(d) Power Supply : 415 volts, 3 phase AC, 50 Hz\n(e) Type of Drive: Regenerated AC variable voltage & variable frequency drive alongwith converter unit. The regenerated power shall be used to charge the battery of UPS & ARD & Emergency light.\n(f) Type of Machine: Gearless permanent magnet & directly coupled Horizontal traction machine\n
18 4.02 (g) Car size (Inside): Not less than 2.35 sqm.\n(h) Car and landing door at all floors : Automatic centre opening with VVVF door drive opening size not less than 1400x2000 mm and sliding type fabricated by stainless steel sheet not less than 16 gauge having hair line finish (N-304) the car and landing doors shall be fire resistance rating of 01 hrs.\n(j) Car enclosure: manufactured with stainless steel frame not less than 16 gauge with Hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with LED light fitting complete internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill wire mesh for protection as per OEM design. \n(k) Terminal buffers: Metal special spring buffers as per manufacturer specifications. \n
19 4.03 (l) Door opening (Inside): protected by centre opening stainless steel doors with hairline finish doors with clear opening of size not less than 1400x2000 mm. \n(m) Counter weight shall be of cast iron as recommended by OEM.\n(n) Car & counter weight Guide: Guide rails of `T' Section Mild steel as per OEM design.\n(o) Flooring: Aluminum chequred plate 5mm thick complete\n(p) Signals :-\n(i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floors.\n(ii) Vacuum Filled Display (LCD/VFD ) for car position indicator of stainless steel \n(iii) One No. car operating panel with Luminous buttons in car (stainless steel).\n(iv) Car direction indicator in car & Landing.\n(v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system shall be separate from ARD batteries).\n
20 4.04 (vi) Overload warning feature in car cabin.(Display and announcing type both)\n(vii) Fireman’s switch one No per lift to be installed at Ground Floor near landing door.\n(viii) All signal fixture & car operating panel on hair line stainless steel face plate with hair line finish.\n(ix) Infra red door sensor safety edge of door for entire height.\n(x) Built in announcing system with hand set(03 Nos, one each in car & near Ground floor landing door and one in machine room).\n(xi) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/exit door is open or closed.
21 4.05 (q) Stops & Opening :7( All opening on same side).\n(r) Safety device : (i) Automatic rescue device (ARD)/automatic landing device to be operating with maintenance free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of Regenerative drive.\n(ii) The ARD actuation time should be less than ten second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.\n(s) Operation: Simplex, full collective selective automatic operation with and without attendant.\n
22 4.06 (t) Machine room: Located above the hoist way .\n(u) Hoist way Constn; existing RCC structure with brick wall construction as existing at site. Total height from G/L to slab of Machine room can be seen at site.\n(v) Control system shall be closed loop type.\n(w) Door shall have ACVVVF controlled door operator.\n(x) Faceplate shape shall be Rectangular and of stainless steel in hairline finish.\n(y) Civil work : Necessary Civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc and one coat of white wash shall be applied on the lift shaft after completion of lift installation.
23 4.07 (aa) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking,connect to complete cell and provn of through & other accessories.
24 4.08 (ab) Provn of governor and governor rope of suitable size ,buffer springs as per manufacture's design,car cabin having powered doors and inspection box at top of the car cabin.
25 4.09 (ac)Provn of safety guarding equipments such as 02 Nos Pit switches controller guarding pit pulley,guarding pit ladders,facia plate to cover free space between car cabin and hoist way & switches.
26 4.1 (ad) Door sensor 81 beam,2D infra red full length .
27 4.11 (ae) provn of ''Press and Speak'' system to be connected with lift complaint cell compatible with exchange.
28 4.12 (af)Do's & Don'ts chart on stainless steel to be installed inside the car cabin.
29 5 Material & Labour in replacement for earthing with galvanized steel earth plate electrode of size 60cmx60cmx6mm thick bured directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanized earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel using GI or steel strip 32X6mm dia as earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 80mm thick made of RCC (1:1:5:3) type A1 duly reinforced with 8mm dia TMT bar @ 100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs, etc, mest, charcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable earth plate complete all as specified & directed by Engr-in-Charge. BI01010001010000000000000515BI0100001137 50 Each
30 6 Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core including taking down of old complete all as specified and as directed,\n BI01010001010000000000000515BI0100001113 500 RM
31 7 Supply & fix in replacement of GI strip 32 x 6 m complete from machine room equipment to earth pit including taking down of old complete all as specified and as directed. BI01010001010000000000000515BI0100001114 450 RM
32 8 Supply, installing, testing and commissioning in replacement of factory made and tested Indoor type Phase Sequence Corrector of capacity 25 HP , 3 Phase 4 Wire, 415 volts, 50 Hz, wall mounted. The Phase Sequence Corrector shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick CRCA mild steel sheet, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035 including taking down of old complete all as specified and as directed. BI01010001010000000000000515BI0100001115 10 Each
33 9 Taking down carefully existing surface/ concealed unserviceable aluminum/ copper point wiring (light, fan, socket, power or sunken box) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc. and making good to disturbed surfaces of walls, floors, ceilings, etc. where required and finished the existing surfaces after complete of new point wiring as specified here-in-after complete all as specified and as directed. BI01010001010000000000000515BI0100001116 150 Per Point
34 10 M & L for point wiring (concealed complete) using 1.50 sqmm size FRLS, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn into and including surface laying of non metallic rigid PVC conduit medium grade (not less than 20 mm dia) for wall and 25mm PVC medium grading grade casing and caping in the ceiling wherever required with and including its all necessary fittings and accessories fixed concealed sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size FRLS stranded copper conductor cable as in earth wire and connecting all metal parts to common earth dolly for one light / exhaust fan point controlled by one, one way switch complete all as specified & directed by Engr-in-Charge \n{Notes:- (i) Switches and sockets to be measured and paid for separately under relevent items.} BI01010001010000000000000515BI0100001117 90 Per Point
35 11 All as per item No. 10 above but one 5/ 6 Amps socket outlet point on the same board with other switches complete all as specified and as directed. BI01010001010000000000000515BI0100001118 10 Per Point
36 12 All as per item No. 10 above but for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. BI01010001010000000000000515BI0100001119 10 Per Point
37 13 All as per item No 10 above but for point wiring with 2.5 sqmm single core multi sranted copper consductor PVC insulated and unsheathed (FRLS) cable 1100 volts grade and 2.5 sqmm PVC insulated and unsheathed (FRLS) cable 1100 volts grade with multistranded copper conductor as earth wire for 15/16 Amps multi purpose socket combination controlled by one, one way switch on independent board complete all as specified and as directed. BI01010001010000000000000515BI0100001120 40 Per Point
38 14 Supply and fixing of switch piano, flush type, ivory finish 5/6 Ampere single pole, one way complete, all as specified and directed by Engr-in-Charge. \n BI01010001010000000000000515BI0100001121 110 Each
39 15 Supply and fixing of socket out let 2 in 1, 3 pin 5/6 Ampere 230V AC flush type complete all as specified and directed by Engr-in-Charge. \n BI01010001010000000000000515BI0100001122 20 Each
40 16 Supply and fixing of switch piano, flush type, ivory finish 15/16 Ampere single pole, one way complete, all as specified and as directed by Engr-in-Charge. \n BI01010001010000000000000515BI0100001123 40 Each
41 17 Supply and fixing of socket out let 2 in 1, 3 Pin suitable for 5/6 Ampere and 3 Pin suitable 15/16 Ampere flush type complete all as specified and as directed by Engr-in-Charge. \n \n BI01010001010000000000000515BI0100001124 40 Each
42 18 Supply and fixing ceiling rose PVC/ polycarbonate, isolated body 63.5x23.5mm, 3 terminals complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001125 89 Each
43 19 supply and fixing in replacemet of exhaust fan 450 mm sweep mettalic body with louver shutter, 230 Volts AC supply complete with fixing arrangement using fastener and necessary electrical connections from ceiling rose to fan with 23/0.0076 Three core PVC Flexible cable etc including taking down of existing old complete all as specified and as directed. BI01010001010000000000000515BI0100001126 10 Each
44 20 Supply and fixing in replacement of Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver LED tube light fitting 18 watt including LED tube, 230 volt including taking down of old one complete all as specified and directed by Engr-in-charge. \n BI01010001010000000000000515BI0100001127 80 Each
45 21 S&F of Electrical Insulating Mats for voltage upto 3.3 KV electrical purpose CONFIRMING TO IS 15652 / 2006, size 2m x lm x 19 mm complete all as specified and as directed, BI01010001010000000000000515BI0100001128 30 Each
46 22 Supply and fixing of MCB SPN 8 way, double door, 240 volts Metalic Distributition board, concealed flush to wall for mounting MCBs factory made , conforming to IS : 13032 fabricated out of CRCA sheet not less than 1.20mm thick fitted with DIN channel, neutral link and 200 Amps rated bus bar DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature , between powder paint process to ensure smooth finish and protection against corrsion atmosphere. the DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified, the DBs shall be of IP 42 protection class including taking down complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001129 10 Each
47 23 Supply and fixing of Miniature Circuit Breaker (MCB, SPN) single pole and neutral, 240 volts 40 Amps current rating 'B' curve 10 KA breaking capacity with thermal overload as well as magnetic short circuit tripping device with quick break trip free mechanism robust design and terminals having heat resistant moulding including taking down old one complete all as specified and directed by Engr-in-Charge. \n BI01010001010000000000000515BI0100001130 10 Each
48 24 All as per item No. 23 above but MCB SP 6-32 Amps complete all as specified and directed by Engr-in-Charge. \n BI01010001010000000000000515BI0100001131 41 Each
49 25 Supply, install, testing and commissioning cubical type CPRI approved dust and vermin proof factory made LT panel board indoor type front opening (double shutter) with locking arrangement of suitable size made out of 2.0mm thick CRCA sheet (IS-8623) with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring, thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1) of suitable size as per panel board 0.5 Mtr above ground level grouting and bottom portion of enclosure shall be minimum 30 cm above ground level of legs of angle iron and supply & comprising of the following including internal pre-wiring complete:- \n400 Amps capacity copper bus bar strip - 4 Nos. of suitable length. \nINCOMING\n(i) MCCB FP 100 Amps, capacity 25kA, 4 pole, 3 phase, 415 volts with thermal magnetic release (Ics = 100% Icu) - 01 No.\n(ii) Voltmeter 0-500 V with selector switch (Digital type) - 01 set. \n(iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set\n(iv) Indicator lamp neon/ LED type RBY -01 Set of three.\nOUTGOING:\n(i) MCCB FP 63 Amps, capacity 25kA, 4 pole, 3 phase, 415 volts - 02 Nos.\n(ii) MCB SPN 40 amps capacity 10 KA single phase - 02 Nos\n BI01010001010000000000000515BI0100001132 5 Each
50 26 All as per item no 24 above but fallowing description\nINCOMING\n(i) MCCB FP 250 Amps, capacity 35kA, 4 pole, 3 phase, 415 volts with thermal magnetic release (Ics = 100% Icu) - 01 No. \n(ii) Voltmeter 0-500 V with selector switch (Digital type) - 01 set.\n(iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set.\n(iv) Indicator lamp neon/ LED type RBY -01 Set of three.\nOUTGOING:\n(i) MCCB FP 150 Amps, capacity 25kA, 4 pole, 3 phase, 415 volts - 01 Nos.\n \n BI01010001010000000000000515BI0100001133 5 Each
51 27 Intercom wifi system
52 28 Supply, fixing and Commissioning of Server Based IPPBX System with 100\nSIP licenses\na) Should support caller line identification\nb) Should support Internal/External hotline\nc) Should support 3way/5way call conference\nd) Should support multiple call handling at operator\ne) Should be able to support minimum 10 operators simultaniously\nf) Should support external call forrward on mobile\ng) Should support voice as well as video calls\nh) Should be expandable upto 4000 ports, BI01010001010000000000000515BI0100001138 1 Each
53 29 Supply, fixing and commissioning of 1KVA Online UPS with (12V,42AH x\n3) battery back-up for supplying power for Server, Network Switch and Radio Transmitters at control room in case of mains fail. The Back up time should be minimum of 2 hours. \n BI01010001010000000000000515BI0100001139 1 Each
54 30 Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity as shown.at server room to protect server and accessories from excess heat and dust, inclding civil work, having specifications\na) Must have 1.5T cooling capacity\nb) Must come with anti-dust filter to prevent even smallest dust particle from passing through it\nc) Must come with LCD remote control with buttons that have glowing lights helps in controlling the AC\nd) Must have Turbo colling mode\ne) It must have 3star rating from BEE for its power saving compressor\nLocation :- Server Room. BI01010001010000000000000515BI0100001140 1 Each
55 31 Supply, fixing and commissioning Wi-Fi Radio transmitters PTMP mode having Specifications.\na) Integrated 18dBi dual polarized 90 degree sector antenna\nb) Smart polling data transmission protocol (iPoll-3)\nc) Meets IP-66 specification\nd) High output power 29dBm radio\ne) Upto 170 Mbps Capacity\n BI01010001010000000000000515BI0100001141 4 Each
56 32 Supply, testing and commissioning of SIP IP Phones for operators at control room, having features\na) 6 Lines\nb) 4.3" (480X272) TFT Colour LCD Display\nc) 5 Programmable soft Keys\nd) 5-way Conference\ne) 24 Programmable Multi-Purpose Keys\nMake - Creative / Polycom / Grandstream BI01010001010000000000000515BI0100001142 2 Each
57 33 Supply, fixing and commissioning of 8 Ports PoE network switch at control room to supply power to SIP Phones, Radios Servers etc.\n BI01010001010000000000000515BI0100001143 1 Each
58 34 Supply, testing and commissioning of 8 Ports network switch at lift\nmachine room to connect radio transmitters and receivers\n BI01010001010000000000000515BI0100001144 1 Each
59 35 Supply, testing and commissioning of 5 Ports network switch at lift\nmachine room to connect radio transmitters and receivers\n\n BI01010001010000000000000515BI0100001145 15 Each
60 36 Supply, fixing and commissioning of wall amount 12U MS-Rack having\nPDU, trays, exhaust fan etc. for mounting SIP server, PoE switch etc. as required.\n\n BI01010001010000000000000515BI0100001146 1 Each
61 37 Supply, fixing and commissioning of Wi-Fi Radio receiver PTP mode having specifications\na) Integrated directional 15dBi panel antenna\nb) Smart polling data transmission protocol (iPoll-3)\nc) Meets IP-66 specification\nd) High output power 29dBm radio\ne) Upto 170 Mbps Capacity\n BI01010001010000000000000515BI0100001147 33 Each
62 38 Supply, fixing, testing and commissioning of 2-Ports FXS gateway at each machine rooms and Security Gate to provide connectivity to lift phone\n BI01010001010000000000000515BI0100001148 1 Each
63 39 Supply, testing and commissioning of customized power supply 600VA UPS with battery back-up at each machine room and Security Gate to provide power to Wi-Fi Radio receivers, FXS gateway ect. in case of mains\nfail. \n BI01010001010000000000000515BI0100001149 17 Each
64 40 Supply, testing, fixing and commissioning of wi-fi handfree lift phone at each lift with high performance amplifier enclosed in SS box with lock\nfacility. \n BI01010001010000000000000515BI0100001150 16 Each
65 41 Supply and commissoning of Analog corded telephone set at Security Gate having specifications\na) FSK/DTMF caller ID compatibility\nb) Minimum 16 digits LCD Display\nc) Realtime clock with date, month & year display\nd) Minimum 30 incoming memory and 5 outgoing memory\ne) Tone/Pulse progammable\nf) Adjustable Ringer volume control\ng) Handfree speaker phone\nh) Visual ringer display\n\n BI01010001010000000000000515BI0100001151 1 Each
66 42 Supply, laying and testing of standard CAT-6 cable of size 0.59 mm x 4 pair that should confirm specifications TIA/EIA-568-A standard for connecting and providing power to Wi-Fi radio transmitters from control room/machine room to\nroof-top and as req.\n\n BI01010001010000000000000515BI0100001152 440 RM
67 43 Supply and fixing of 1" PVC pipe from control room to Wi-Fi transmitter and machine room to Wi-Fi receivers to protect CAT-6 cables running\nthrough it. \n BI01010001010000000000000515BI0100001153 360 RM
68 44 Supply and installation of enclosure for FXS Gateway, Adaptors, Rosette\nbox etc. at lift machine rooms and Security Gate. \n BI01010001010000000000000515BI0100001154 17 Each
69 45 Supply and fixing of 2" GI pipe Medium grade at roof-top providing support to Wi-Fi antennas at roof-top of all buildings including civil work if required.\n BI01010001010000000000000515BI0100001155 26 RM
70 46 Supply and fixing of PDU (3+1) to provide AC power to FXS gateway, Wi-Fi\nadaptor, UPS etc. at machine room. \n BI01010001010000000000000515BI0100001156 18 Each
71 47 Supply and fixing sheet metal enclosure single pole and neutral with two pin earth plug and socket complete with one single pole MCB 20 Amp 240 volts half grouting on wall all as specified and directed. \n BI01010001010000000000000515BI0100001157 1 Each
72 48 Supply and fixing of emergency calling gateway including of all accessories complete all as directed by Engr-In-Charge. BI01010001010000000000000515BI0100001158 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail