Provision Of Auditorium At Ins Kadamba, Karwar, KARWAR-Karnataka

Military Engineer Services-MES has published Provision Of Auditorium At Ins Kadamba, Karwar. Submission Date for this Tender is 01-06-2021. Auditorium Construction Tenders in KARWAR Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

27341101
Corrigendum : Provision Of Auditorium At Ins Kadamba, Karwar
Open Tender
Indian
Karnataka
KARWAR
01-06-2021

Tender Details

PROVISION OF AUDITORIUM AT INS KADAMBA, KARWAR

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Mar-2021 date amendment 30 Mar 2021 Date 19-04-2021
2 08-Apr-2021 Date amendment 08 Apr 2021 Date 27-04-2021
3 16-Apr-2021 date amendment 16 Apr 2021 Date 03-05-2021
4 20-Apr-2021 Revised/additional tender pages Other 03-05-2021
5 20-Apr-2021 Revised Drawings Other 03-05-2021
6 26-Apr-2021 date amendment 26 Apr 2021 Date 14-05-2021
7 29-Apr-2021 Re Revised BOQ BOQ 14-05-2021
8 06-May-2021 date amendment 06 May 2021 Date 25-05-2021
9 10-May-2021 Re-Re-Revised BOQ BOQ 25-05-2021
10 25-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-06-2021

Key Value

Document Fees
INR 3000 /-
EMD
INR 1175000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVISION OF AUDITORIUM AT INS KADAMBA, KARWAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCH 'A' PART-I "BUILDINGS & STRUCTURES"\nTotal of Sch-'A' Part-I B/F from Serial Page No.27 1 Lump sum
2 2 SCH 'A' PART- II "SITE CLEARANCE, EXCAVATION & EARTH WORK.\nTotal of Sch "A" Part-II B/F from Sl page No 29 1 Lump sum
3 3 SCH 'A' PART-III "INTERNAL WATER SUPPLY"\nTotal of Sch "A" Part-III B/F from Sl page No 30 1 Lump sum
4 4 SCH 'A' PART-IV "INTERNAL ELECTRIFICATION"\nTotal of Sch "A" Part-IV B/F from Serial Page No 34 1 Lump sum
5 5 SCH 'A' PART-V "ROAD/ PATH / CULVERTS"\nTotal of Sch "A" Part-V B/F from Serial Page No 36 1 Lump sum
6 6 SCH 'A' PART-VI "AREA DRAINAGE "\nTotal of Sch "A" Part-VI B/F from Serial Page No 38 1 Lump sum
7 7 SCH 'A' PART-VII "COMPOUND WALL , FENCING AND GATE "\nTotal of Sch "A" Part-VII B/F from Serial Page No 40 1 Lump sum
8 8 SCH 'A' PART- VIII "FIRE DETECTION & FIRE ALARM SYSTEM"\nTotal of Sch "A" Part-VIlI B/F from Serial Page No 45 1 Lump sum
9 9 SCH 'A' PART-IX ""LIGHTIENING PROTECTION""\nTotal of Sch "A" Part-IX B/F from Serial Page No 46 1 Lump sum
10 10 SCH 'A' PART-X "SEWAGE DISPOSAL"\nTotal of Sch "A" Part -X B/F from on Serial Page No 48 1 Lump sum
11 11 SCH 'A' PART-XI "EXTERNAL WATER SUPPLY"\nTotal of Sch "A" Part-XI B/F from Serial Page No 49 1 Lump sum
12 12 SCH 'A' PART-XII "EXTERNAL ELECTRIFICATION"\nTotal of Sch "A" Part-XII B/F from Serial Page No 52 1 Lump sum
13 13 SCH 'A' PART-XIII "AIR CONDITIONING"\nTotal of Sch "A" Part-XVI B/F from Serial Page No 54 1 Lump sum
14 14 SCH 'A' PART-XIV "ARBORICULTURE"\nTotal of Sch "A" Part-XVI B/F from Serial Page No 55 1 Lump sum
15 15 SCH 'A' PART-XV "PILE FOUNDATION"\nTotal of Sch "A" Part-XVI B/F from Serial Page No 56 1 Lump sum
16 16 SCH 'A' PART-XVI Prime Cost Sum for "PA EQUIPMENT AND VIDEO PROJECTION SYSTEM" 1 PRIME COST SUM
17 17 SCH 'A' PART- XVII" MISCELLANEOUS ITEMS"\n
18 18 "PILE FOUNDATION"
19 18.01 M&L for boring / drilling in to any strata other than hard rock for 500mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed. 667 RM
20 18.02 M&L for boring / drilling in hard rock for 500mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed. 47 RM
21 18.03 M&L for boring / drilling in to any strata other than hard rock for 600mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed. 1484 RM
22 18.04 M&L for boring / drilling in Hard rock for 600mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed. 104 RM
23 18.05 M&L for RMC M-30 design mix concrete as in piles using tremie pipe concrete method for 500/600mm dia piles with minimum 400 Kg cement per Cum complete all as specified and directed. 590 Cum
24 18.06 M & L for testing of piles (Initial Test) as per IS 2911 Part 4 up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for 500 mm dia piles complete all as specified and directed through NABL / Goverment approved accredited laboratory. 1 Each Job
25 18.07 M & L for testing of piles (Initial Test) as per IS 2911 Part 4 up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for 600 mm dia piles complete all as specified and directed through NABL / Goverment approved accredited laboratory. 1 Each Job
26 18.08 M&L for testing of piles (Routine Test) as per IS 2911, Part 4, up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for the 500 mm dia piles complete all as specified and directed through NABL / Government approved accredited laboratory. 2 Each Job
27 18.09 M&L for testing of piles (Routine Test) as per IS 2911, Part 4, up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for the 600 mm dia piles complete all as specified and directed through NABL / Government approved accredited laboratory. 2 Each Job
28 18.1 M&L for carrying out integrity test on job piles of 500/600mm dia piles including bringing at site all testing material complete and removing of the same after completion of satisfactory testing of piles complete all as specified and as directed through NABL/Government approved accredited laboratory. 67 Each Job
29 19 "INTERNAL ELECTRIFICATION"
30 19.01 Supply and Fix Lamp holder insulated body with back plate and including LED Lamp 9 Watt for angle holder all as specified. Make: Havells/LEGRAND/Anchor/Leader\n 4 Each
31 19.02 S & F LED light fittings decorative 36/34 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. \nMake- WIPRO /HAVELLS /JAQUAR /PHILLIPS 5 Each
32 19.03 Supply and fixing LED Step light strip of 1 meter long embeded in aluminium extrusion wth acrylic cover and fixed on floor emitting a low light to outline a specific area or used for guideline for step,5 watt per meter including driver in duly powder coated aluminium die cast housing. IP65. Halonix/Crompton/HPL/Philips. 66 Each
33 19.04 Supply and fixing recess mounting accent lighting luminaire with dia cast aluminium heat sink and sand grain finishing refletor with DALI dimmable driver round LED down lighter ,20 watt wide beam , 4000 k ,100 lm/w system .IP 20. havells/ Halonix / HPL/Philips.cat no RS271B LED 20/840 PSD WB WH ( for Main Hall & Stage ) 26 Each
34 19.05 Supply and fixing recess mounting accent lighting luminaire with dia cast aluminium heat sink and sand grain finishing refletor with DALI dimmable driver round LED down lighter ,40 watt wide beam , 4000 k ,100 lm/w system .IP 20. havells/ Halonix / HPL/Philips.cat no RS271B LED 40/840 PSD WB WH ( for Main Hall ) 44 Each
35 19.06 Supply and fixing Track mounted spot accent lighting luminaire with no external gear box and magnetic hinge arrangement for easy aiming and perfect punch in the beam.,20 watt wide beam , 4000 k ,100 lm/w system .IP 20. havells/ Halonix / HPL/Philips.cat no ST916T LED20/940 PSU 1C WB BK IN ( for Stage ) 18 Each
36 19.07 Supply and fixing Surface Mounting Up-Downlight Luminaires wall mounting outdoor type 1x 50 watts made out of Black epoxy powder coated aluminium housing with wall mounting bracket Par light fitting. Bajaj/Crompton/Havells/HPL/Philips. 8 Each
37 19.08 Supply and fixing Flood light fitting LED 200 Watts, energy saving environmental friendly, long life exclusive innovatiive die cast aluminium IP 66 flood light with high power LED as light source suitable for high lighting architectural features or retail spaces FloodTune is easy to use, reliable and cost effective color changing outdoor flood light for creating dynamic lighting effects by just using your smart phone to control lights. ( For stage lighting)\n Make : Bajaj cat n0- BARFEG 200W LED/HAVELLS cat no- JETA PROPLUSFL200WLED757LT G /Cropton Cat no -LSFO-200-CDL/60 12 Each
38 19.09 Supply and fixing Gong Bell 225 mm dia , 230 volts 3 Each
39 19.1 S & F MCB DB VERTICAL TYPE , suitable for RCBO / MCB as incommer,,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door , L&T / LEGRAND / Schneider/ ABB 4 Each
40 19.11 S & F MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incomer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ Schneider/ ABB ( for stage lighting & projection room ) 2 Each
41 19.12 S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps 3 Each
42 19.13 S & F MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating 162 Each
43 19.14 NOTE FOR ITEM NOS. 19.10 TO 19.13 - MAKE OF MCCB & MCB - LEGRAND/HAGER/SCHNEIDER/l&T
44 19.15 S&F Exhaust fan heavy duty of size 225 mm sweep PVC body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. \nMake:- Havells/Crompton Greaves/Bajaj 23 Each
45 19.16 S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. ( for Tech Building & Adm Building ) -Make:- Crompton Greaves/ Bajaj/Orient 30 Each
46 19.17 Supply & fixing wall mounted fan 450 mm sweep high speed, thermally protected motor, heavy duty gear box, 90 degree oscillation for wide coverage conforming to IS-2997-1964 all as specified and directed by Engineer-in-Charge. \nMake:- Havells/Crompton Greaves/Bajaj/Orient 20 Each
47 19.18 Supply and lay 2 pair Telephone Cable copper 0.5 mm dia ATC drawn through conduit. 250 RM
48 19.19 S & F RJ 11 Telephone socket 4 Each
49 19.2 Supply, Installation, test and Commissioning CPRI approved factory fabricated, Indoor type, LT Pannel Board made out of 2.00 mm thick CRCA Sheet dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - Metre room ) 1 Each
50 19.21 (a) MCCB 250 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No. (incoming)
51 19.22 MCCB 125 A 25 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -02 No. (outgoing for stage lighting & projector room)
52 19.23 (b) MCCB 63 A 25 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -02 Nos. (outgoing)
53 19.24 (c) MCCB 40 A 25 KA, 2 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -11 Nos. (outgoing)
54 19.25 (e) Aluminum TPN bus bar 250 Amps - 01 Set
55 19.26 (f ) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 including CT 250X5 Amps 3 Nos & selector switch
56 19.27 (g) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch
57 19.28 (h) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
58 19.29 (j) Electronic energy trivactor meter- 01 No,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240v AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection (in case of wrong electric connection),capability to display & communicate ( in case of absence of main supply), with optical port, deficiency metering with either phase/neutral current, IP 51 protection, as per IS13779 including CT,make of meter -L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalent of secure
59 19.3 S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make-WIPRO /HAVELLS /JAQUAR /PHILLIPS (for green room & other rooms) 42 Each
60 19.31 S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS ( for Toilets) 32 Each
61 19.32 S & F MCB DB VERTICAL TYPE , suitable for RCBO / MCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door. 11 Each
62 19.33 S & F ISI marked RCBO 40 A, 30 mA, 230 V DP for AC applications, conforming to IS 12640 (Part-2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed. 11 Each
63 19.34 S & F ISI marked RCBO 63 A, 30 mA, 230 V DP for AC applications, conforming to IS 12640 (Part-2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed. 4 Each
64 19.35 MCCB TPN 125 Amps , 415Volts, 25KA ,4 POLE , Icu=Ics=100% L&T / LEGRAND / hager / schneider/ ABB 2 Each
65 19.36 Supply & fix PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial 3 core 2.5 sqmm cable, 1100 Volt, conforming to IS 694 Supply & fix PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial 3 core 2.5 sqmm cable, 1100 Volt, conforming to IS 694 ( for stage lighting ) 2200 RM
66 19.37 S & F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps 2 Each
67 19.38 S & F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 40Amps 1 Each
68 19.39 SITC of 12 Channel Signal Dimmer Controller which can support for DALI Broadcas with Instant visual feedback on channel status for all 12 channels. Device should have override option on the control itself. Supply Voltage: 100-240AC, system Output DC current 200mA which can support 10 button panels without any additional power supply. Device should also have dry contact Aux input.Similar to Dynalite DDBC1200 of Philiphs or equivalant of Havells /Crompton/Bajaj 1 Each
69 19.4 SITC of 12-channel controller supports switched loads of up to 20 A per channel, up to a maximum device load of 180 A. DIN-rail mountable device, designed to be installed into the distribution board supplying power to the controlled circuit. Supply Voltage: 100-240AC, system Output DC current 200mA which can support 10 button panels without any additional power supply. Device should also have dry contact Aux input.Similar to Dynalite DDRC1220FR-GL-V3 of Philiphs or equivalant of Havells /Crompton/Bajaj 1 Each
70 19.41 Supply, installation, testing and commissioning of Antumbra Push type 6 key User Interface White with White Rim for workstations, break out areas, training rooms etc with Fully programmable options for Indivuidual control / group control / Scene control / Tasks etc. Wall mounted on 2M (3 X 3 size) modular box. Front cover black with Backlight, built in proximity and Loaded icons like presentation scenario, meeting scenario, master On/ Off, Powersaving mode etc along with a LED indicator for each operations. Custom engraving facility. Operating on 12V DC @ 40-50mA from Dynet network. Philliphs (Item Code: PA6BPE-WW-X + DACM-V2) or equivalant of havells /crompten/Bajaj 2 Each
71 19.42 Supply, installation, testing and commissioning of Philips Dynalite DDNP1501 is a 15 V DC 1.5 A regulated power supply designed to supplement the DyNet network DC supply.The DyNet network is self-powered via built-in DC suppliesintegrated within all mains powered devices. Use of high consumption devices, such as edge-lit touchscreens, can necessitate a requirement for additional power. Make philliphs (Item code: DDNP1501) orequivalant of havells /crompten/Bajaj 1 Each
72 19.43 S&F LED recess mount down light fitting of 18w having System Efficacy of 110 lm/W, system output 2000 lumens, THD <10%, PF >0.95, CRI >80, Body made of piece die cast aluminium housing having PC diffuser, Life L70B50 @ 50k hrs. Cat no: DN296B LED20S 4000K PSD WH of Philliphs or equivalant of Havells/Crompten/Bajaj ( For Front passege & Side passege) 77 Each
73 20 "FIRE DETECTION AND FIRE ALARM SYSTEM"
74 20.01 "FIRE DETECTION SYSTEM"
75 20.02 Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 2280LPM discharge at 90 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main FF) 1 Each Job
76 20.03 Supply install test and commissiong of centrifugal pump set ,diesel driven complete with all accessories suitable for pumping water 2280LPM discharge at 90 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main FF) 1 Each Job
77 20.04 Supply install test and commissiong of centrifugal Jockey pump set ,Electric driven complete with all accessories suitable for pumping water 180LPM discharge at 90 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items (jockey pump) 1 Each Job
78 20.05 Supply install test and commissiong of centrifugal Booster pump set ,Electric driven complete with all accessories suitable for pumping water 450LPM discharge at 36 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items (Booster pump) 1 Each Job
79 20.06 Supply and laying Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9, in any length laid in trenches of size 80mm dia Including rubbur Tytan joint complete all as specified and as directed. 120 RM
80 20.07 Supply and laid spigot/flanged/ socketed DI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 80mm to 300 mm dia.\n 500 KG
81 20.08 Supply and Fixing of CI foot valve of size 150 mm dia with stainer conforming to IS :4038 with gun metal seat (flapper) nuts bolts, gaskets, washers etc. only for negative suction (Normex Make 0 % leakage) 2 Each
82 20.09 Supply and Fixing of CI foot valve of size 100 mm dia with stainer conforming to IS :4038 with gun metal seat (flapper) nuts bolts, gaskets, washers etc only for negative suction (Normex Make 0 % leakage) 1 Each
83 20.1 Supply and fixing of one no brass orifice plate having 6 mm thickness, outer dia is of 160 mm and inner dia suitable to reduce the pressure betwween 3.2 Kg / cm v square to 5.5 Kg /cm square at every single outlet hydrant valve DANFOS make pressure switch with 12/15 mm dia isolation valve GI nipple elbow etc. 12 Each
84 20.11 Supply and fixing of MS priming tank for negative suction only, fabricated from 3 mm MS sheet having capacity 1000 Ltrs with manhole cover float valve 20/25 mm inlet valve and 50 mm outlet valve with necessary GI piping up to delivery of pump, tank should be painted with two coat of red oxdide and two coat of red enamel paint, including MS structure supports. 1 Each
85 20.12 Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 2mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main FF Pump) 1 Each
86 20.13 INCOMING:-\n\n
87 20.14 (a) Incoming MCCB 160 A 35 KA, 4 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no- CM92109OOM1OG / Legrand cat no-420247/ Schneider cat no-LV516343-01 No
88 20.15 (b) Bus bar made out of Aluminium flat of capacity 200 Amps- 4 Nos ( 3 nos for phase and 1 no for neutral)
89 20.16 OUTGOINGS:-\n\n\n
90 20.17 (a) MCCB TP 125 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For main pump)
91 20.18 (b) MCCB TP 32 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For Booster Pump & Jocky Pump & Light Load)
92 20.19 (c)Automatic Starter delta starter for 75 HP pump -01 No (For main pump)
93 20.2 (d) BLANK
94 20.21 (e) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 including CT 200X5 Amps 3 nos & selector switch - 1 no
95 20.22 (f) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch
96 20.23 (g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
97 20.24 (h) Single phasing preventer -02 Nos
98 20.25 Providing and applying one coat of 4mm thick 'PYPKOTE' or COATEK anti rust pipe protection conforming to IS : 10221 including approved primer as per manufactures specificatons and lap of 25mm to made an impermeable layer on M.S.Pipe of size 80mm dia running underground / burried / in trenches complete including surface preparation. 33 SQM
99 20.26 Providing and applying one coat of 4mm thick 'PYPKOTE' or COATEK anti rust pipe protection conforming to IS : 10221 including approved primer as per manufactures specificatons and lap of 25mm to made an impermeable layer on M.S.Pipe of size 150mm dia running underground / burried / in trenches complete including surface preparation. 138 SQM
100 20.27 "FIRE ALARM SYSTEM"
101 20.28 SITC of Intelligent Addressable Fire Alarm Panel, 2 Loop capacity expandable up to 5 loop with minimum 250 addresses on every loop . minumum 160 characters LCD Display, Battery Charger and Power Supply. Complete with all mounting accessories. Furnished with SMF type Lead Acid Battery in above panel for 24 hours backup in case of power failure, and 30 minutes in Alarm Condition. 1 Each Set
102 20.29 SITC of Intelligent Addressable Fire Alarm Repeter Panel, Double Loop capacity expandable up to 5 loop with minimum 250 addresses on every loop . minumum 160 characters LCD Display, Battery Charger and Power Supply. Complete with all mounting accessories. Furnished with SMF type Lead Acid Battery in above panel for 24 hours backup in case of power failure, and 30 minutes in Alarm Condition. 1 Each Set
103 20.3 Supply and erecting of " Fire Ray 2000" Optival Beam Complete with Transmitter, Receiver, Controller & Apolo XP95 Addressable Zone Monitor unit for Addressing. 3 Each
104 20.31 M & L for Fire Extinguisher Dry Chemical powder (ABC) type 5 Kg capacity. Ceasefire 9 Kg fire extinguisher mono Ammonium phosphate powder 50, stored pressure type, pressure Guage, Gross weight 8 Kg, empty weight 3 KG, can height 449 mm, Diameter 150 mm, discharge time less than 15 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C, & electrically started fire A rating 13A, B rating 34B, can construction deep down and CO2 mig welded valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyster powder coating Sheet metal thickness : 1.80 MM, ISI and EN approved, 5 years warranty. Make cease Fire ABC Powder Map 50 5 Kg – 1AB04CF 15 Each
105 20.32 Fire Extinguisher Carbon Dioxide type of 4.5Kg capacity.Ceasefire 4.5kg CO2 Gas typre fire Extinguisher, Trolly mounted, Easy weight management Used Unused Mechanism Squeeze Grip, Gross weight 9.1kg empty weight 14.6kg, Can height 857MM, Diameter 140MM, Discharge timeless than 10secs controllable discharge mechanism Applicable on class B&C fire, B rating 21B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal coating of Can : Not Applicable, External Coating of Can : Spray painting sheet metal thickness 4.5MM, ISI Approved 1 year warranty. Make Cease Fire CO2-4.5Kg - Squeeze Grip - 1CO11CF 15 Each
106 20.33 Fire Extinguisher water type 9 Ltr capacity. Ceasefire 9Ltr Water type Fire Extinguisher, Stored pressure Type, Pressure Gauge,Gross Weight 14.6 Kg, empty Weight 5.6 Kg, Can Height 611MM, Diameter 175MM, Discharge Time less than 120 Secs, Controllable discharge mechanisum, Range minimum 6 mtrs applicable on class a fire a rating 13A, can construction : deep drawn & CO2 Mig welded, valve construction : Forging & machining internal coating of Can : Epoxy p[owder coating, External coating of Can : Epoxy polyster powder coating sheet metal thickness : 2.0MM, ISI and EN Approved, Helium Leak Detection tested, 1 year warranty. Make Cease Fire Water-9 Ltr Stored Pressure - 1CO02CF. 5 Each
107 20.34 Supply and Fixing of Buckets ( 9 Ltrs Capacity ) round bottom painted in red and lettered fire with bracket to hang on wall of pillar as directed. 6 SET
108 20.35 Construction of brick masonary valve chamber of size 1200x 1200x1200 mm (internal dia) suitable for 150 mm dia sluice valve with necessary earth work excavation plain cement concrete 1:4:8 using 40 mm graded stone aggregate 75 mm thick in cement mortar 1:6 15 mm thick plastering 1:6 internally including flooring and externally rep to 15 mm below ground level plain cement concrete 1:4:8 type B1 using 20 mm graded stone aggregate in coping MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement applying two coat of synthetic enamel paint including dismantling removing the existing damage chamber completely removal of debris to a distance not exceeding 50 mtr distance depositing where as directed by Engr-In-Charge. 2 Each
109 20.36 Providing, fixing, testing and commissioning of 150 mm dia cast iron installation control valve assembly (test pressure should not be less than 15.0 Kg/Sq.cm) with flanges, nut, bolts & gasket complete with pad locking arrangement, vertical wet alarm valve with hydroulic alarm motor & gong, 2 nos pressure gauges as per manufacturer recommendation with ball valves, 15mm dia test valves, 50mm dia drain valve with all necessary accessories. 1 Set
110 20.37 Providing & fixing cast iron single acting air valve with screwed inlet 25mm dia including ball valve and all fittings complete all as specified and as directed.\n 1 Each
111 20.38 Providing and fixing inspection & testing assembly/drain assembly consist of following :- 1 Each
112 20.39 a) 25mm dia Inspection Test Valve (Ball Valve)
113 20.4 b) Gun Metal Sight Glass
114 20.41 c) Union
115 20.42 d) 50mm dia drain valve with piping
116 20.43 M & L for Low smoke Zero helogen flame retardent fire alaram cable 2 core, 1.5 mm² copper conductor confirming to BS7629-I , BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performance silicon rubber with electrostatic screen of aluminium fire barrierType LT53 outer sheathconfirming to BS 7655 , red in colourdrawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed.. 500 RM
117 20.44 Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet Dust and Vermin Proof , single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (FF booster pump ) 1 Each Job
118 20.45 (a) Incoming MCCB 32 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No
119 20.46 OUTGOINGS:-
120 20.47 (a) MCB TPN 25 Amps - 1 Nos
121 20.48 (b) DOL Starter for 10 HP Pump set-1 Nos
122 20.49 ( c ) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-1nos
123 20.5 (d) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1no
124 20.51 (e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
125 20.52 (f ) Single phasing preventer -01 No
126 20.53 Supply and fixing of 15 mm ( 1/2 ")dia NBCM body chrome finished quartzoid bulb sprinkler having 57 deg C fixed temperature rating with defletor disc of conventional construction including MS ERW GI pipe conforming to IS: 1259 including fitting and fixture up to & including 50 mmdia pipe ( As shown in drg) cost of pipe including /below 50 mm is included). 56 Each
127 20.54 Cutting the existing CI pipe line 200 mm dia bore and inserting one Tee 250mm x 250mmx 80 mm including connecting pipes, collars etc. complete including necessary excavation and earthwork complete all as specified and directed. 1 Each Job
128 21 "External Water Supply"
129 21.01 Supply install test and commissiong of centrifugal Mono block pump set , electric driven complete with all accessories suitable for pumping water 330 LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building) 2 Each Job
130 21.02 M&L for construction of valve pit chamber 60 cm x 60 cm x 60 cm internal dimension with 10 cm thick foundation using PCC 1:4:8 type D-2 over 10 cm thick hardcore, 20 cm thick PCC block wall built in cement and sand motor 1:4,15 mm thick internal plaster including top of floor in cement and sand motor 1:5, finished even and smooth, with out using extra cement, 1.4 mm thick MS sheet cover with 20x20x4 mm flat iron hold fast, hinges, handle, locking arrangement and applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface including disposal of surplus soil of to a distance of n.exc 50 m complete all as specified and directed. 2 Each Job
131 21.03 Cutting the existing CI pipe line 200 mm dia bore and inserting one Tee 200mm x 200mmx 50 mm including connecting pipes, collars etc. complete including necessary excavation and earthwork complete all as specified and directed. 1 Each Job
132 21.04 Supply and fix Brass foot valve, flanged end and drilled of size 50 mm dia ISI MARKED 2 Each
133 21.05 Supply and fix Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete of size 50 mm dia 2 Each
134 21.06 Supply and fix brass double end flanged and drilled non return valve of size 50 mm dia ISI MARKED 2 Each
135 21.07 Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 2 mm thick CRCA Sheet , single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( main water supply pump ) 1 Each Job
136 21.08 (a) Incoming MCB TPN 32 A, 10 KA, 4 POLE , L&T /Legrand /schneider -01 No
137 21.09 (b) Aluminum TPN bus bar 50 Amps - 01 Set
138 21.1 OUTGOINGS:-
139 21.11 (a) MCB SPN 16 Amps - 2 Nos
140 21.12 (b) DOL Starter for 3 HP Pump set-2 Nos
141 21.13 ( d ) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-1nos
142 21.14 (e) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 Nos.
143 21.15 (f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
144 22 "DG SET"
145 22.01 (a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.\n 1 Each Job
146 22.02 (b)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.\nMake: Kirloskar/ashok leyland/cummins
147 22.03 (a) Radiator with blower fan or heat exchanger with guard.\n(b) Pipe coupling for engine cooling system piping.\n(c ) Corrosion inhibitor coolant\n(d) Paper element filters\n(i) Fuel filter\n(ii) Lube oil filter\n(iii) By pass\n(e) Fly wheel housing and fly wheel to suit alternator.\n(f) Engine bearing mechanism in fly wheel housing.\n(g) Shut off coil with safeties for LLOP/HWT/over speed.\n(h) Dry type air cleaners and vacuum indicators.\n(j) Residential silencers.\n(k) Stainless steel exhaust flexible bellows.\n(l) Motor driven priming pump.\n(m) Battery charging alternator.
148 22.04 (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap.\n(o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of 30 gauge for the entire length of exhaust pipe.\n(p) First fill of oil, coolant and diesel during commissioning and 12 hours testing.\n(q) Interconnecting copper cabling of adequate capacity batteries control.\n(r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot\n(s) Self starter 12 volts DC.\n(t) Electric operated electronic governor.\n(u) Fuel injection pump.
149 22.05 (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:-\n(i) 24V Battery- 2 Nos\n(ii) Water temperature.\n(iii) lubricating oil pressure.\n(iv) Engine speed -1500Rpm\n(v) Engine hours\n(vi) Frequency.\n(vii) Voltage.\n(w) Safety control (Trip and indication).\n(i) High water temperature\n(ii) Low lube oil temperature\n(iii) Overspeed stop\n
150 22.06 (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads.\n(y) Battery:-24 volts(02x12V Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).\n(z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
151 22.07 (c) Alternator: Suitable rated 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof, insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)\nMake: Stampford/Crompton/Kirloskar
152 22.08 (d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-
153 22.09 (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).\n(ii) Outer body : 1.6mm thick CRCA\n(iii) Door : 1.6mm thick CRCA\n(iv) Base frame : ISMC 300\n(v) Inside illumination : 1 No.- 1 x 10 watt LED fitting of Make Phillips/ Bajaj/ Crompton.
154 22.1 (e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
155 22.11 (f) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
156 22.12 (g) Digital load manager : Three phase 4 wire indicating V, I, PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.\n(iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.\n(iv) Bottom gland plate for incoming and outgoing cables.\n(v) Circuit diagram plate.
157 22.13 (h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule.\nNote:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
158 23 "EXTERNAL ELECTRIFICATION"
159 23.01 Supply, install, testing and commisioning of Distribution transformer mounted on massoniry platform step down , 11 KV/0.433 KV, Three Phase complying with IS: 1180(Part-1) 2014 with all latest amendments till date, Outdoor type double copper wound suitable for 50 Hz system of capacity 500 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn 11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %. Losses should be confined to the limits specified as follows : maximum allowable losses at full load (100 %) & Half Load (50 %) shall not be exceeded 1.35 % & 0.93 % respectivly as per GRAHA RATING, Percentage Impedance : 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/technical specifications : -\n 1 Each Job
160 23.02 (a) Lifting lug for transformer and tank.
161 23.03 (b) Earthing terminal rating and diagram plate.
162 23.04 (c ) Air release device.
163 23.05 (d) Oil filling inlet pipe with plug.
164 23.06 (e) Drain outlet pipe with brass gate valve.
165 23.07 (f) Conservator tank with oil level indicator
166 23.08 (g) Silica jel breather
167 23.09 (j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.
168 23.1 (k) Type of connection Delta/Star
169 23.11 (l) Type of cooling: Oil and Natural Air.
170 23.12 (m) Vector group:DYN 11.
171 23.13 (n) Temperature rise over an ambient of 50 °C maximum.
172 23.14 (o) Cable end box on both side for HT/LT cables of suitable size.
173 23.15 (p) Provision of thermometer with pocket.
174 23.16 (q) Provision of oil and winding temperature gauge.
175 23.17 Supply & Fix Battery chargers of sufficient capacity to suit battery sets of 50V, 200 AH Capacity. The battery chargers suitable for 110V-100AH battery sets shall be operative from single phase, 50 Hz, 230 Volts AC supply.The battery charger shall be operative on Thyristor based Silicon Controlled Rectifier (SCR) both for float & boost section. 1 Each
176 23.18 Supply,Installation,Testing and commissionbing `11 KV indoor, 630 Amps, 18.1 KA for 3 Sec HT Vaccum Circuit Breaker for Incommer confirming to the IEC 62271-200,IAC-AFLR-25KA for 3 Sec PM KLSC -2B comprising of the following equipment :- 1 Each
177 23.19 800 Amps continous Bus Bar material shall be of high condiuctiveity electrolytic copper only.All Bus bars shall be insulated with heat shrinkable PVC sleeves and joints shall be covered with bitumen compound followed by HT tape. Phase identification shall be made at the end by coloured tape. Bus bars shall be mounted on integral seal off bushings all inter connection shall be of electrolytic grade copper only with joints silver plated.
178 23.2 Circuit breaker shall be mounted on a with drawable truck which shall roll out horizontally from service position to isolated position with ease and .MAKE: ANDREWYULE/AREVA/SIEMENS/ABB
179 23.21 Motorised Spring charged Mechanism
180 23.22 Separate eartyhing truck shall be provided for bus earthing and cable earthing.
181 23.23 Cast Resin Current Transformer, 11 KV, 50/25/5 A, 15 VA, CI 5P 10, CIO 5 Core II PS Class-03 Nos
182 23.24 Cast Resin Three phase Potentail Transformer 11 KV/ 3/110V/ 3, 200VA, CI 1.0 – 03 Nos with desired capacity PT Fuses.
183 23.25 Accessories like local remote selector switch, Breaker Control Switch (TNC), space Heater with Thermostat, DC & AC Control Ckt through MCB, indicating LEDF lamps for RYB Phases, Spring Charged, DCV Supply helath Breaker ON/OFF, Breaker in service, Test Disconnected position.
184 23.26 Multifunction meter, Digital type (Displaying A,V,PF,Hz,KVA,KW,KVAR,KWh,KVARh etc) Class 0.5 with RS 485 port for commuinication of Modbus protocol Make : : L&T, Conzerve.
185 23.27 SCADA compatible NUMERICAL NON-DIRECTIONAL IDMT four pole 3 O/C + 1 E/F WITH iNSTANTENEOUS OVER CURRENT AND EARTH FAULT PROTECTION Feeder Protection Relay -01 NOS . Make: ASHIDA Model No: ADR241A/equivalent in ABB /areva/ Siemens.
186 23.28 High Speed Master Trip Relay – 1 No . Make ASHIDA Model No : AVAJH 33/ equivalent in ABB or Siemens.
187 23.29 Trip Circuit Supervision Relay (VAX) – 1 No Make ASHIDA Model No : ATSR31A/ equivalent in ABB or Siemens.
188 23.3 Air Insulated rear end Bottom Entry Cable Box suitable for termination of XLPE Cables.
189 23.31 Panel Must Have additional features
190 23.32 (i)  Continous rated closing/tripping coils
191 23.33 (ii)   Sprimg Charging Handle
192 23.34 (iii)    Fully internal Arc tested for 25 KV for 3 Sec
193 23.35 (iv)     Manual closing /tripping of the CB with compartment door closed
194 23.36 (v)   Short time rating for 3 seconds as per IEC 62271-100
195 23.37 (vi)    Mechanical endurance test-M2
196 23.38 Breaker shall be provided with following features
197 23.39 (i)     Auxillaty Switch 6 NO + 1 NC Contacts mounted on the draw out portion of the switchgear
198 23.4 (ii)     Position Cell Switch with 3 NO + 1 NC Contact on each for test position and Service Position.
199 23.41 Digital independent Volt meter and ammeter of suitable ratings- 01 each
200 23.42 Inbuild Power pack battery bank OF 30 volt DC (15 nos + 1 nos Spare) Lead acid VRLA MAINTANANCE FREE battery of 2 volts 100 AH) INCL necessary internal connection , wooden/steel racks suitable for kept at powerhouse including Automatic Floatt cum boost ( 20AMPS) Battery charging equipment SCR controlled suitable for 30Volts 100 AH VRLA batteries
201 23.43 Note- (i) Auxiliary Supply Voltage for the Relay/Close/Trip coil 30 Volt DC. (ii)-proposed VCB shall be fixed with exsisting VCB panel with all necessary extension of busbar chamber . Rate is inclusive of extention of busbar chamber
202 23.44 Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Panel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–\nMake of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER \n(Location - Main Panel near Transformer) 1 Each Job
203 23.45 a) Bus bar made out of Aluminium flat of capacity 1200 Amps- 3 nos for phase and 1200 Amps 1 no for neutral - 01 Set
204 23.46 (b ) Aircircuit breaker 800 amps ,4pole ,breaking capacity 50ka ,ICU=ICS=ICW for 1 sec of total selectivity ,Draw-out type ,EF version inbuilt 6 NO+6NC aux contact,door ceiling frame , manually & electrically operated complete with 240 v shunt trip coil ,closing coil & motor for electrical charging , C power S-1 RANGE ,confirming to IS/IEC 60947-2,microprocessor base relay ,high short time withstand capcity,100% neutralpole,self dignoistic microprocessor based with onload testing through test button with cover ,inbuilt thermal memory,protection relese conform to EMI/EMC standerd,breaker control through MODBUS potocall complete all as specified as per \nL&T MODEL NO-SR18G & CAT NO - SL96072 / LEGRAND MODEL NO-DMX 3 -N2500 & CAT NO -0287 31 or equivalant of SCHNEIDER/ABB-1 NO FOR (I/C)
205 23.47 (c)MCCB 630 A 35 KA, 3 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no-CM94104OOT1OG /Legrand cat no-025540/Schneider cat no-LV540310- 2 nos (AMF Panel (1) & spare)
206 23.48 (d) MCCB 400 A 35 KA, 4 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no-CM98401OOROOG /Legrand cat no-4220 60/Schneider Cat No-LV540309 -01 No. (APFC Panel)
207 23.49 (e) Ammeter Class-1,digital pannal mounting type 96mmx96mm L&T Cat No WDS301FCA00 including CT 1200X5 Amps-3 nos & Selector Switch-1 No
208 23.5 (f) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T Cat No. WDS301FEV00 & Selector Switch- 1 No
209 23.51 (g) Indicator lamp LED (RYB) Cat Part No 1SFA611400R1001 of ABB or equivalent in L&T/Indo Asian/Legrand - 3 Nos
210 23.52 (h) Electronic energy trivactor meter,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240V AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), with optical port,deficiency metering with either phase/netral current, IP 51 protection, as per IS13779,, L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalent of secure - 01 No each.
211 23.53 Supply, Installation, test and Commissioning CPRI approved factory fabricated, outdoor type, LT Pannel Board outdoor type made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and testing after installation including complete all as specified and comprising of the following :– (utility DG Panel ) 1 Each Job
212 23.54 (a) Bus bar made out of Aluminium flat of capacity 1000 Amps- 3 nos for phase and 1000 Amps 1 no for netural - 01 Set
213 23.55 (b) MCCB 630 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94104OOT1OG /Legrand cat no-025540/schneider cat no-LV540310 I- No Incoming
214 23.56 (c) MCCB 400 A 35 KA, 3 POLE ,thermal magnetic release, Ics=100% Icu & L&T /Legrand /Schneider- 2 no (AC Plant & spare)
215 23.57 (d) (i) MCCB TP 250 Amps , 415Volts, 35KA ,3 POLE L&T CAT NO-CM92008OOM1OG/ LEGRAND CAT NO-420087 / equivalent of ABB -01 No. (auditorium buliding Panel) (ii ) MCCB TP 160 Amps , 415Volts, 35KA ,3 POLE L&T CAT NO-CM92008OOM1OG/ LEGRAND CAT NO-420087 / equivalent of ABB -01 No. ( Fire Fighting Panel)
216 23.58 (e) MCCB 32A 415V TP, 10 KA - 03 Nos ( street light , water supply & FF Booster panel)
217 23.59 (f) Ammeter Class-1,digital panel mounting type 96mmx96mm L&T Cat No WDS301FCA00 including CT 1000X5 Amps 3 nos & selector switch 1 no
218 23.6 (g) Voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T Cat No. WDS301FEV00 & selector switch- 1 No
219 23.61 (h) Indicator lamp LED (RYB) Cat Part No 1SFA611400R1001 of ABB or equivalent in L&T/Indo Asian/Legrand - 3 Nos
220 23.62 (j) Astronomical, Multifunctional digital time swithces Cat Part No 2CSM204365R1341 of ABB or equivalent in L&T/Indo Asian/Legrand 1 No
221 23.63 (k) Power contactor ML-3 , 3 pole rating not less than 40 A with 230 coil make L&T/SEIMENS- 1 No.
222 23.64 Supply, installation, testing and commissioning of outdoor type 1200 A sandwich type silver flashed, bi-metal copper contact, aluminium busway (3L + N + PE), with original Mylar insulation from Dupont, 100% neutral, 50 kA for 1 second, 50% integral earth, dual housing complete all as specified and directed.\nMake: Schneider, ABB, Siemens
223 23.65 The busbar trunking system shall conform to the following technical specifications:
224 23.66 [A] General:
225 23.67 [i] The busbar trunking system (BTS), both feeder and plug-in, shall be of sandwich construction. All components and fittings (straight length, elbow, tees, flanged ends, cable tap box and circuit breaker, etc.) shall be in accordance with IEC 61439 Part 6 (2012) or UL857 and from the same manufacturer as the busbar trunking system. Degree of protection of the BTS shall be IP 65 in accordance with IEC 60529.
226 23.68 [ii] Rated operation voltage of the BTS shall be 1 kV. The neutral conductor shall have the same cross-sectional area as the phase conductor. The earth busbar must be one continuous piece without bolting on housing.
227 23.69 [B] Certificate:
228 23.7 [i] The busbar, of full range and each rating, shall pass full type tests specified in IEC 61439-6. The certificate shall be issued by an international independent testing authority (e.g. ASTA, KEMA, UL).
229 23.71 [ii] A product safety mark (e.g. KEMA-KEUR, ASTA DIAMOND, UL) shall be on the product offering a visible assurance to all of full product safety testing, factory inspection and ongoing surveillance under independent authority to ensure the ongoing safety of product.
230 23.72 [iii] The BTS shall pass seismic tests with actual physical product and being certified complying with UBC seismic Zone 4 condition by an international recognized earthquake research body, e.g. Asian Pacific Network of Centers for Earthquake Engineering Research (ANCER).
231 23.73 [C] Short-Circuit Ratings & Tests:
232 23.74 [i] The whole BTS shall be capable of withstanding the short circuit of the electrical installation without undergoing any electrical, mechanical and thermal stress under fault condition at a service voltage of 1 kV at 50 Hz frequency. The minimum rated insulation voltage shall be 1 kV.
233 23.75 [ii] Minimum certified short circuit ratings shall be 198 kA peak and 90 kA for 1 s for 3200 A BTS.
234 23.76 [D] Housing:
235 23.77 [i] The busbar trunking housing shall be constructed of electro galvanized steel and aluminum to reduce hysteresis and eddy current loses and shall be provided with a suitable protective finish of ANSI 49 grey epoxy paint.
236 23.78 [ii] The busbar trunking housing shall be totally enclosed non-ventilated for protection against mechanical damage and dust accumulation. And it shall pass at least 2000 hr salt spray test to ensure the anticorrosion ability.
237 23.79 [iii] The totally enclosed housing shall be manufactured by the busbar trunking manufacturer. Modifications of busbar trunking to make it totally enclosed by housing other than the busbar trunking manufacturer voids the manufacturer’s warranty. Busbar trunking so modified is unacceptable without the written consent of the manufacturer.
238 23.8 [E] Busbars:
239 23.81 [i] Busbars shall be of aluminum with copper cladding utilized Molecular Fusion technology.
240 23.82 [ii] There shall be no bolts passing through the busbars of the busway.
241 23.83 [iii] Each busbar shall be insulated with Class B (130 ?) DuPont Mylar insulation. Epoxy insulation is unacceptable.
242 23.84 [iv] The temperature rise at any point of the busbar trunking enclosure shall not exceed 55° C above the ambient temperature of 40° C when operated at rated current.
243 23.85 [F] Joints:
244 23.86 [i] The busbar trunking joint shall be of the one-bolt type which utilizes a high strength steel bolt(s) and Belleville washers to maintain proper pressure over a large contact surface area.
245 23.87 [ii] The bolt shall be torque indicating and at earth potential.
246 23.88 [iii] The bolt shall be two-headed design to indicate when proper torque has been applied and require only a standard long handle wrench to be properly activated.
247 23.89 [iv] Access shall be required to only one side of the busbar trunking for tightening joint bolts.
248 23.9 [v] It shall be possible to remove any joint connection assembly to allow electrical isolation or physical removal of a busbar trunking length without disturbing adjacent busbar trunking lengths.
249 23.91 [G] Plug-in Openings:
250 23.92 [i] The connecting jaw of the plug-in unit shall plug directly on to the busbar and have full contact with busbar itself. Welded tab at plug-in busbar is unacceptable.
251 23.93 [ii] All contact on joint and plug-in opening should be silver plated copper.
252 23.94 [iii] On plug-in busbar trunking there shall be three dead front, hinged cover type plug-in openings on each side.
253 23.95 [iv] All openings shall be usable simultaneously.
254 23.96 [v] Busbar trunking shall be installed so that plugs are side mounted to permit practical use of all plug-in openings.
255 23.97 [vi] It shall be possible to inspect the plug-in opening and busbars prior to the installation of the plug-in units.
256 23.98 [H] Plug-in Units:
257 23.99 [i] The plug-in jaw shall be spring design composed of different metal to ensure the firm and tight contact with the busbar.
258 24 [ii] Plug-in Units shall be type tested in accordance with IEC 61439-6 (Annex D: Part 1-5 and 9-13).
259 24.01 [iii] The earthing contact of the plug-in unit shall always be made before that of the live conductors and the last to break during removal. And it must connect to the earth bar of busway to ensure the safety.
260 24.02 [iv] Covers of all plug-in units must have interlocks to prevent the cover from being opened when the switch is in the ON position.
261 24.03 [v] Plug-in units (circuit breaker type or fusible switch type) shall be operated with visible blade quick-make and quick-break mechanism.
262 24.04 [vi] Presence of transparent shield shall be inside to avoid direct contact of human.
263 24.05 [vii] The plug-in units shall be equipped with internal barriers to prevent accidental contact of fish tape and conductors with live parts on the line side of the protective device during time of wire pulling.
264 24.06 [J] Supporting Structure:
265 24.07 Indoor feeder and plug-in busbar trunking shall be approved for hanger spacing of up to 3 meters for horizontally mounted run and 4.88 meters for vertically mounted runs. Outdoor feeder busbar trunking shall be approved for spacing of up to 1.5 meters for horizontally or vertically mounted runs.
266 24.08 [K] Voltage Drop:
267 24.09 [i] The 3-phase line to line voltage drop 40% power factor concentrated load shall not exceed 3.4 V per hundred ft.
268 24.1 [ii] The line-to line voltage drop at the load power factor shall not exceed 4.1 V per hundred feet.
269 24.11 Straight feeder 20 RM
270 24.12 90º elbow 2 EACH
271 24.13 Flange end 2 EACH
272 24.14 Copper flexible (braided) 1 Set
273 24.15 Adopter box (local item) 2 EACH
274 24.16 Edge-wise hangers 10 EACH
275 24.17 Straight feeder 10 RM
276 24.18 90º elbow 2 EACH
277 24.19 Flange end 2 EACH
278 24.2 Copper flexible (braided) 1 Set
279 24.21 Adopter box (local item) 2 EACH
280 24.22 Edge-wise hangers 10 EACH
281 24.23 Supply and fixing 60 watt LED roadway luminarie, made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection with high power LEDs as light source and HF electronic driver of 90W capacity including making necessary connection complete all as specified and directed. Make : Bajaj cat No. BRTFG 60W LED I/Havells cat no-ENDURAPEARLPLUSSL60WLED757SASYTOPC/Crompten cat no-LSTP-60-CDL 10 EACH
282 24.24 Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, outdoor type , double door, APFC capacitor bank Panel Board of size as recommended by manufactrer 120 KVAR with 8 steps (25+25+25+12.5+12.5+10+5+5) WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 3.15 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprosing of following. Make of pannel L&T/ SCHNEIDER/ABB 1 EACH Job
283 24.25 Particulars
284 24.26 INCOMER
285 24.27 MCCB 400 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94105OOR1OG /Legrand cat no-025538/schneider cat no-LV540309 -01no
286 24.28 ROM+SPDR - 1 no
287 24.29 Auxiliary 1 c/o +TAC 1 c/o- 1 no
288 24.3 OUTGOING CAPACITOR FEEDERS : -
289 24.31 25 KVAr Capacitor feeder comprising of:- ( 3 Nos. )
290 24.32 80A, BUSSMANN FUSE 80ET,-9 nos
291 24.33 Thyristor switching module 25kVAR, 440V , TSM,LTTSM-3 nos
292 24.34 7% Detuned Aluminium Reactor 25KVAr 440V-3 NOS
293 24.35 Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 30 kVAr,sutable for 480V , LTXL - 3 NOS
294 24.36 Push Button ON/OFF -6nos
295 24.37 Indicating lamps 6 NOS
296 24.38 Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
297 24.39 6A DP MCB , C CURVE 3 NOS
298 24.4 12.5 KVAr Capacitor feeder comprising of:- ( 2 Nos. )
299 24.41 40A, BUSSMANN FUSE- 6 NOS
300 24.42 Thyristor switching module 25kVAR, 440V,TSM,LTTSM - 2 NOS
301 24.43 7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS
302 24.44 Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 15 kVAr,sutable for 480V - 2 NOS
303 24.45 Push Button ON/OFF -4nos
304 24.46 Indicating lamps 4 NOS
305 24.47 Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
306 24.48 6A DP MCB , C CURVE 2 NOS
307 24.49 10 KVAr Capacitor feeder comprising of:- ( 1 No. )
308 24.5 40A, BUSSMANN FUSE- 3 NOS
309 24.51 Thyristor switching module 25kVAR, 440V,TSM,LTTSM -1 NOS
310 24.52 7% Detuned Aluminium Reactor 10 KVAr 440V LTAL,CAT NO-0712B2- 1 NO
311 24.53 Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 12.5 kVAr,sutable for 480V - 1 NO
312 24.54 Push Button ON/OFF -2nos
313 24.55 Indicating lamps 2 NOS
314 24.56 Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 1
315 24.57 6A DP MCB , C CURVE 1NOS
316 24.58 5 KVAr Capacitor feeder comprising of:- (2 Nos. )
317 24.59 16A, BUSSMANN FUSE 6 nos
318 24.6 Thyristor switching module 10kVAR, 440V,TSM,LTTSM - 2nos
319 24.61 7% Detuned Aluminium Reactor 5 KVAr 440V,LTAL,CAT NO-0712B2-2 no
320 24.62 Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 7.5 kVAr,sutable for 480V ,LTXL- 2nos
321 24.63 Push Button ON/OFF -4nos
322 24.64 Indicating lamps 2 NOS
323 24.65 Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
324 24.66 6A DP MCB , C CURVE 2 NOS
325 24.67 Incomer Metering
326 24.68 APFC relay 8 stage {BLR CM – 06T MB } -1 NO\n[230/ 110 V, 1/5A, 50 Hz] \n[Transistor output + Single CT sensing + RS 485 MODBUS]
327 24.69 Digital Voltmeter (3Ph, Class 1) -1 NO
328 24.7 Digital Ameter (3Ph, Class 1, 5A) -1 NO
329 24.71 Metering CT --/5A, Class-1- 3 NOS
330 24.72 SMPS 5A, Input 230V AC Output 24V DC -1 NO
331 24.73 ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
332 24.74 Auxiliary Contactor {4NO} with 24V DC}-3 NOS
333 24.75 Auto Manual selector switch -1 NO
334 24.76 Indicating Lamp(R,Y,B)-3 NOS
335 24.77 6A SP MCB-3 NOS
336 24.78 6A DP MCB
337 24.79 6A FP MCB -1 NO
338 24.8 8" {EBM NADI} Fan -1 NO
339 24.81 S&F decorative type 35/40W LED Post Top Lantern luminaire made of cast aluminium spigot housing with decorative clear opal acrylic diffuser Light fitting IP 65 protection complete includung GI pipe light grade for mounting the fitting all as per directed by Engr-in-Charge Make : Bajaj cat No. -BGCT W4 LED WW / Crompton cat no-LTPO-40CDL / Havells cat no- RUBYPT35WLED757PSYMTOPC/or equivant of Philips.\n 4 EACH
340 24.82 S & F LED Bolard light fittings 8/9/10 Watt integral decorative with opal acrylic cone series ip 65 protection, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size & PCC foundation 30cmx30cmx45cm height etc. Make : Bajaj cat No. -BGBOM6509WLEDW/Crompton cat no-LBLTW10WW/ Havells cat no- CONEBL8WLED757PSYMTOPC/or equivant of Philips. 22 EACH
341 24.83 S&F in repairs FRP cable looping boxes of size 300 mm x 200 mm x 105 mm with TPN aluminium busbar and MCB SP 6 Amp- 01 No, 10 KA breaking capacity, C curve series, factory made with PVC sheet including heavy duty connector for connection of 4 core cable & fixed to pole with suitable size flat iron clamp, nuts & bolts complete all as specified and directed by Engr-in-Charge. \nMake :Sintex or as approved by GE 50 EACH
342 24.84 Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified and directed by Engr-in-Charge. 10 EACH
343 24.85 Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified. 15 EACH
344 24.86 Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified and directed by Engr-in-Charge. 60 EACH
345 24.87 Supply and fixing 60/65 watt LED roadway luminarie, made up of spun aluminium housing for lamp and reflector assembly with clear polycarbonate cover and IP65 protection with high power LEDs as light source and HF electronic driver of 60/65W capacity including decorative hot deeped galvanised mild steel pole 7 meter long with black powder finised making necessary connection complete all as specified and directed. Make : Bajaj cat No. -BNRRL 65 LED /Crompton cat no- LPTE-60-CDL and equivant of Havells/ Philips.\n 16 EACH
346 24.88 S&F decorative type 45/35W LED Post Top Lantern luminaire made of diacast aluminium housing with decorative clear toughned glass difuser Light fitting IP 65 protection complete includung including decorative hot deeped galvanised mild steel pole 3 meter long with black powder finised all as per directed by Engr-in-Charge Make : Bajaj cat No. -BRIL 45 LED NW/Crompton cat no-LPTOI-45CDL/ Havells cat no- ENDURASPRING6PT35LED757PSYMTOTG/or equivant of Philips.\n 2 EACH
347 24.89 Supply and fix M & L Hot dip galvanised Iron octagonal pole of height 6 mtrs minimum galavnising of 70 microns, top 70 mm , bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm foundation bolts, single arm GI bracket of 900x1000 mm for mounting the light fitting at an angle of 120 degree,backelite sheet with one 6 A SP MCB and 16 mm stud type connectors -04 nos inside the pole at the door opening for cable connections,common template s minimum 01 for each 15 poles all fixed and bolted on and incl suitable PCC pedestal as per manufacturers recommendations and specifications all as directed \nMast and pole shaft shall be be as per BSEN 10025,IS 5986, ASTM A572 ,\nFoundation as per IS-2062\nGalvanization as per IS-4759/2629\nMake of pole- Bajaj / Jindal /Crompton/Shubham-\n 10 EACH
348 25 ACOUSTIC SYSTEM & SPECIAL TYPE FACING
349 25.01 ACOUSTIC SYSTEM
350 25.02 Material and labour for providing acoustic system to wall panelling (absorptive) all as specified, shown on drawing and directed by Engineer in Charge 610 SQM
351 25.03 Material and labour for providing acoustic system to False Ceiling (absorptive) all as specified, shown on drawing and directed by Engineer in Charge 380 SQM
352 25.04 Material and labour for providing acoustic system to False Ceiling (reflective) all as specified, shown on drawing and directed by Engineer in Charge 700 SQM
353 25.05 SPECIAL TYPE FACING
354 25.06 Material and labour for providing glass mosaic work plain externally all as specified, shown on drawing and directed by Engineer in Charge 150 SQM
355 25.07 Material and labour for providing glass mosaic work Mural externally all as specified, shown on drawing and directed by Engineer in Charge 100 SQM
356 26 "AIR CONDITIONING SYSYEM"
357 26.01 Supply, Installation, Testing & Commissioning DX type Air Cooled Scroll Chillers/ condensing Unit with Single / Multiple Compressor of Open Type Motor, Starter Panel machine mounted, Air cooled condensor with anti corrosion coating on condensor coil, Insulated Chiller, vibration isolators, integral Refrigerent piping & wiring, accessories Microprocessor Based Control Panel & all mounted on a steel frame complete as per specification capacity as below :- 3 EACH JOB
358 26.02 (a) Motor shall be sutiable for 415V +/- 15%, 50 C/S, 3 Phase, AC supply.
359 26.03 (b) Refrigerent used shall be R134a/ R407c/ R22 as mentioned in specifictions.
360 26.04 (c) Chiller
361 26.05 (d) Chilled Water Inlet Temp. 12o C
362 26.06 (e) Chilled Water Outlet Temp. 7o C
363 26.07 (f) Fouling Factor 0.0005 FPS.
364 26.08 (g) Condenser
365 26.09 (h) Inlet Air Temp to the Condensor. 38o C
366 26.1 (j) Capacity upto 74 TR Each. (2 working+ 1 stand by )
367 26.11 Make : Blue Star Model No XAC2YS-080AR2 Or equivalent model of make : Daikin / Carrier
368 26.12 M & L for Centrifugal back pull out end suction pump set Energy Efficient having cast iron body, bronze impeller, shaft seals, with driven by squirrel cage induction motor suitable for 3 Phase, 415V +/- 10%, 50 Hz power supply mounted on common base frame with required insulation. 3 EACH JOB
369 26.13 (a) Water quantity - 13 LPS @ 24 Mtrs Static Head , Motor rating 7.5 HP
370 26.14 (b) (2 Working + 1 Stand by)\nMake : Kirloskar Model No. KDI 830 or equivalent in CG/ Groundfos
371 26.15 Supply, Installation, Testing and Commissioning of Double Skin Type Floor mounted Air Handling Unit as per specification mentioned below :- 2 EACH JOB
372 26.16 (a) Floor mounting, Cabinet PUF insulated, Sanwich panel of 40mm thick, 40Kg/cum Density, SS drain tray, 6 Row Deep Chilled water Cooling Coil having Coil face velocity which should not exceed more than 500 FPM with coil section, DIDW forward / Backward curved centrifugal fan, door limit switch, non flammable Pre filter of 10 micron as a single stage filter, supply air Damper, vibration isolator, Fan Drive motor, TEFC suitable for 3 Phase, 415 V, 50 c/s, AC supply, Belt Drive package, Flexible Connection etc complete as specified & directed.
373 26.17 (b) Outer skin - 0.63mm thick plain GSS.
374 26.18 (c) Inner skin - 0.63mm thick pre-coated GSS.
375 26.19 (d) 30000 CFM, 50mm TSP Model No. ZDS300 Make ZECO or equivalent of make BlueStar / Carrier.
376 26.2 Supply, Fabrication, Erection, Testing & commissioning of M.S.ERW 'C' Class pipe of 100mm dia conforming to IS : 1239/3589 Heavy Class Including all fittings like Bends, Elbows, tees, anchors fasteners, Pipe Supporting, supported by rigid PUF block / Wooden Gatti etc. The entire chilled water piping shall be insulated with 50mm Thick TF quality Thermocol applied by hbot bitumen and covered by polythene sheet as vapour barier. This Insulation should be Finally covered with Aluminium Cladding of 26 guages Sheet with Self Tapping Screws etc complete as specified & directed. \nMake : Zindal / Tata Steel 42 RM
377 26.21 Supply, Fabrication, Erection, Testing & commissioning of M.S.ERW 'C' Class pipe of 80mm dia conforming to IS : 1239/3589 Heavy Class Including all fittings like Bends, Elbows, tees, anchors fasteners, Pipe Supporting, supported by rigid PUF block / Wooden Gatti etc. The entire chilled water piping shall be insulated with 50mm Thick TF quality Thermocol applied by hbot bitumen and covered by polythene sheet as vapour barier. This Insulation should be Finally covered with Aluminium Cladding of 26 guages Sheet with Self Tapping Screws etc complete as specified & directed. \nMake : Zindal / Tata Steel 60 RM
378 26.22 Supply, Fabrication, Erection, Testing & commissioning of M.S.ERW 'C' Class pipe of 25 mm dia conforming to IS : 1239/3589 Heavy Class Including all fittings like Bends, Elbows, tees, anchors fasteners, Pipe Supporting, supported by rigid PUF block / Wooden Gatti etc. The entire chilled water piping shall be insulated with 50mm Thick TF quality Thermocol applied by hbot bitumen and covered by polythene sheet as vapour barier. This Insulation should be Finally covered with Aluminium Cladding of 26 guages Sheet with Self Tapping Screws etc complete as specified & directed. \nMake : Zindal / Tata Steel 6 RM
379 26.23 Supply and fixing of C-1 Non return Valves 80mm dia with matching flanges gasket hardware etc. duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 26SWG Aluminium sheet cover should be divided into protions etc complete as specified & directed. \nMake : Danfos / Castle / Keystone/Zoloto 22 EACH
380 26.24 Supply and fixing of Balancing valves 80mm dia with matching flanges gasket hardware etc. duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 26SWG Aluminium sheet cover should be divided into protions. \nMake : Danfos / Castle / Keystone/Zoloto 5 EACH
381 26.25 Supply and fixing of 3-Way Mixing valve 65mm dia alongwith modulating actuator, Thermostat, matching flanges gasket hardware etc. duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 26SWG Aluminium sheet cover should be divided into protions. \nMake : Siemens / Sauter 2 EACH
382 26.26 Supply and fixing of CI Y strainers of size 80mm dia with matching flanges gasket hardware duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 20SWG Aluminium sheet cover should be divided into protions. \nMake : Danfos / Castle / Keystone/ Zoloto 5 EACH
383 26.27 Supply and fixing of Expansion Bellow size 80mm dia with matching flanges gasket hardware. 6 EACH
384 26.28 C.I.Ball Valves for Drain Valve of size 32mm Dia. \nMake : Danfos / Castle / Keystone/ Zoloto 4 EACH
385 26.29 C.I.Ball Valves for Drain Valve of size 25mm Dia. \nMake : Danfos / Castle / Keystone/ Zoloto 1 EACH
386 26.3 Supply, Installation, Testing and Commissioning of G.I.B drain piping of size 32mm dia with elbows, bends, tees, cleanouts etc. With elbows, bends, tees, cleanouts etc. with 25mm Thick TF quality Thermocol insulation and covered with 26G Aluminium Cladding. \nMake : Jindal / Tata / Zenith 42 RM
387 26.31 M&L PVC Rigid Drain water piping of size 40mm dia. 40 RM
388 26.32 M&L Auto Air Purge valve 20mm dia. \nMake : Anergy / Rapid Control 4 EACH
389 26.33 M&L Pressure Gauge 4" Dia Dial Type with shut off valve 0 to 10 Kg / Sqcm. \nMake : Waree / H.Guru 16 EACH
390 26.34 M&L Stem type vertical Thermometer Type 0o C to 50o C. \nMake : Emerald / H.Guru / Taylor 10 EACH
391 26.35 Supply and installation of flow Switch at chiller outlet. \nMake : Kele 2 EACH
392 26.36 M&L for HDPE TANK 500 liters, with all accessories, float valve, drain etc. and covered with 50mm Thick TF quality Thermocol and finished with 26G aluminium cladding. \nMake : Sintex / Polycon 1 EACH
393 26.37 Supply and installation of Accoustic insulation on supply air ducts with 25mm glaswool rigid board of 48 kg/cum density, RP tissue paper covered with 0.63mm thick perforated aluminium sheet. 200 SQM
394 26.38 Supply and Installtion Aluminium powder coated supply and return Linear grille. \nMake : Air Master / Air Product / Dynacraft 17 SQM
395 26.39 Supply, Fix and Installatin of Aluminium Box Type Collar Dampers. Make : Air Master / Air Product / Dynacraft 7 SQM
396 26.4 Supply and Installation Volume Control Dampers in GSS construction. Make : Air Master / Air Product / Dynacraft 2 SQM
397 26.41 Supply and Installation Fire damper with necessary arrangement for Fusible Link. \nMake : Air Master / Air Product / Dynacraft 2.5 SQM
398 26.42 M&L Fresh air arrangement comprising volume control damper, cowl piece and with bird screen. \nMake : Air Master / Air Product / Dynacraft 1 EACH
399 26.43 M&L powder coated Electrical panel of size 1900x1900x400mm made of 2 mm CRCA Sheet metal, Cubical type, dust/vermin proof, Floor mounted Shaded IS-7032, powder coated, Protectin IP-5X. 1 EACH
400 26.44 (A) Incoming
401 26.45 (i) 315 A TP MCCB 25KA Type D-Sine, Make L&T-01 No
402 26.46 (ii) 500A TPN copper Busbar-01 No
403 26.47 (iii) 0-500V Volmeter, Type-Digital-01 No
404 26.48 (iv) 200/5A Ammeter, Type-Digital-01 No
405 26.49 (v) 200/5A C.T.'s, Type-Digital-10VA, Qty-3 Nos
406 26.5 (vi) Selector Switch, Type-ASS/VSS-2 Nos
407 26.51 (vii) Controller MCB, Type-SP 2A, Qty-3 Nos
408 26.52 (viii) Indicating Lamps R Y B, Type LED -3 Nos
409 26.53 (B) Outgoing
410 26.54 (i) 60 KW Chiller - 03 Nos (2W + 1 S By)
411 26.55 (ii) 160A TP MCCB 25KA -03 Nos
412 26.56 (iii) Spreader Terminal Link - 03 Nos
413 26.57 (iv) 5.5 KW DOL Pumps - 03 Nos (2W + 1 S By)
414 26.58 (v) 32 A TP MCB, class 'C', 10KA - 03 Nos
415 26.59 (vi) 2 A Control MCB, Type SP - 03 Nos
416 26.6 (vii) 18 A Contractors, Type-MNX 18 - 03 Nos
417 26.61 (viii) Add On Block, Type-MX, Qty - 03 Nos
418 26.62 (ix) Overload Relay (9-15A), Type-MN-2, Qty - 03 Nos
419 26.63 (x) Push button with Elements, Type-22.5D, Qty - 06 Nos
420 26.64 (xi) Indicating Lamps, Type LED, Qty - 06 Nos
421 26.65 (xii) Terminals, Type-Clipon, Qty - 03 Nos
422 26.66 Supplying & Fixing Starter panels for AHUs Size 800x600x200 mm made of 14SWG CRCA Sheet metal, cubical type, dust / vermin proof, Floor mounted shaded IS-7032, Powder coated, Protection IP-5X 2 EACH JOB
423 26.67 (i) 7.5 KW AHU Panel
424 26.68 (ii) 160 A TP MCCB - 01 No
425 26.69 (iii) 2 A Control MCB, Type SP - 01 No
426 26.7 (iv) 22 A Contractors, Type-MNX 80 - 03 Nos
427 26.71 (v) Add On Block, Type-MX, Qty - 03 Nos
428 26.72 (vi) Overload Relay (12-18), Type-MN-1 No
429 26.73 (vii) Timer, Type-800S-1 No
430 26.74 (viii) Control Transformer 30VA, Type-230/24V-1 No
431 26.75 (ix) Push button with Elements, Type-22.5D, Qty - 02 Nos
432 26.76 (x) Indicating Lamps, Type LED, Qty - 03 Nos
433 26.77 (xi) Terminals, Type-Clipon, Qty - 01 No
434 26.78 Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) [ Air Conditioning 6 nos + 8 nos Lightning protection +18 Ext Elect\nNOTE-: GI earth strip shell be measured and paid for separately under relevant item of schedule . 32 EACH SET
435 26.79 Supply & Laying cable from each AHU panel in AHU room to main AC plant panel 3 core x 1.5 sq.mm. 150 RM
436 26.8 S&F welded steel wire cable tray in 50x100mm mesh configuration produced from lateral and longitudinal side walls, steel wire with minimum diameters as specified, with all standard fittings / fixtures / couplers as recommended by the manufacturer and fixed to walls / ceillings as per site requirements of size 150mm wide & 54mm high. Make : Asian / Profab Engineers / Indian 50 RM
437 26.81 Supplying & Fixing Thermal insulation on False celling / wall panelling with 50mm thick, 24Kgs/M3 density Glass Wool in roll form, sealed in polythene bags etc complete as directed. \nMake : Twiga 2000 SQM
438 26.82 Supplying & Fixing Under decl Insulation in 20mm thick pre insulated polyisocyanurate sandwhich panels with density of foam 38kg/M3 & embossed with 60 micron aluminium foil including necessary fittings fixtures etc complete as directed. 2000 SQM
439 27 "AUDITORIUM CHAIR LIGHTS (SPECIAL LIGHTS)"
440 27.01 12V LED power supply for the LED booster amplifier. Make Custom Brand 6 EACH
441 27.02 Supply and fixing LED Step light in white powder coated cast aluminium body with IP-65 protection,3/4 watt in duly powder coated aluminium die cast housing. IP65. Bajaj/Halonix / HPL/Philips. 30 EACH
442 27.03 Supply and fixing Single sided LED signage with built in battery back-up for 2 hrs. LED Entry/ Exit sign light ,3 watt in CRCA powder coated with clear acrylic, screen printed/ etching /deep engraving display. Bajaj/Halonix/havells/HPL/Philips. 10 EACH
443 27.04 LED controller with Remote. \nMake "Illumax" Brand 2 EACH
444 27.05 Supply and fixing chair LED light , suitable for 12v supply with .IP 20. Crompton/Havells/HPL/Philips. 145 EACH
445 28 "STAGE LIGHTING"
446 28.01 MODULAR WIRED FIXED HEAVY-DUTY STAGE LIGHTING BAR SYSTEM MAKES RIGGING LIGHTS QUICK AND EASY WITH POWER OUTLETS BUILT INTO THE BAR FOR LIGHTING APPLICATIONS.:\nOver Head Light Bar fabricated with Steel Rectangular Tube 4" x 4" x 16 Gauge dia pipe of full length interlocked with 2"inch square pipe lincked with 2"inch round pipe for trussing with adequate clamps, bars can be linked together side by side to form a single rigid bar, bar can be hung from wire ropes, chains or hung from an existing grid\n this lighting bar painted in side, outside with zinc chromate primer finally coated with black quick drying enamel paint to mounting for stage lighting, which is suspended from bars above the stage to focus/Wash the stage. Make -Canara/ Stage Works/ Illumitex/ Effectron 3 EACH
447 28.02 Truss FOH “FRONT OF HOUSE” LIGHT BAR: 40NB dia pipe of full length trussing with adequate clamps, this lighting bar painted in side, outside with zinc chromate primer finally coated with black quick drying enamel paint required which is suspended from ceiling in front of stage to focus stage. 36ft Length.Make -Canara/ Stage Works/ Illumitex/ Effectron 1 EACH
448 28.03 Side Ladder: P/f of the side ladders made out of 50x25mm MS tube pipe size: 4x2 ft. 8 EACH
449 28.04 350w17R super beam moving head light\ndouble prisms(rainbow effects), glass gobos.\noltage, AC100-240V 50/60Hz \nPower consumption: 500W \nLight Source: PHILIPS 350W lamp \nBallast: Electronic Ballast \nChannels: OMX 18/22 Channels \nColor wheel: One color wheel, 13 colors + open Gobo wheel: One static gobo wheel, 13 gobos+ open Prism: Two rotating prism, \nOne 16-facet prism and one 32-facet prism \nFrost: Gradually frost, wash angle 5-30 degree Strobe: 0.5-14/c variable strobe effect \nLens: Glass optic lens, linear zoom 0-20 degree Movement: Pan 540 degree, 8/16 bit resolution \nTilt 270 degree, 8/16 bit resolution \nPan/Tilt movement auto repositioning function. \nAuto reset when mis-positioned. \nThree motor makes movement quicker, smoother and more mute. \nIP Grade: IP20 \nMake -Canara/ Stage Works/ Illumitex/ Effectron \n 4 EACH
450 28.05 19x15W LED Zoom Moving Head Wash Light\nZoom: 12-60degree \nVoltage / frequency: AC100-240V, 50-60Hz. \nRated power: 230W. \nLight source: 19 high brightness and high power \n15W LED lamp beads. \nLamp life: about 60,000 hours. \nColor: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216 color changes. Focusing angle: 12-60 degrees. \nControl channel: 16CH. \nOperating mode: voice control, self-propelled, master­slave, DMX512 \nDisplay interface: LCD display in Chinese and English. Dimming: 0-100% linear dimming. \nStrobe: 1-20 times/second ultra-high speed strobe effect. Horizontal scanning 540 degrees (16bit), vertical scanning 270 degrees (16bit), fast, no jitter, no noise, accurate positioning. \nProtection level: IP20. \nPerformance characteristics: a variety of built-in program effects \nMake -Canara/ Stage Works/ Illumitex/ Effectron 4 EACH
451 28.06 54X3W Indoor RGBW slim\nLED Par, Aluminum Die Cast Make -Canara/ Stage Works/ Illumitex/ Effectron 24 EACH
452 28.07 54X3W Indoor Warn White Slim\nLED Par Aluminum Die Cast Make -Canara/ Stage Works/ Illumitex/ Effectron 12 EACH
453 28.08 54X3W Indoor UV slim LED\nPar Aluminum Die Cast Make -Canara/ Stage Works/ Illumitex/ Effectron 6 EACH
454 28.09 200w COB Par LED with barndoor\n1x200W warm white+white 2in1/warm white/white \nVoltage: AC110- 220V, 50-60HZ \nPower: 100W/200W \nLight source: 100W COB/200W COB \nColor: warm white, white \nDimming: 0- 100% \nControl mode: voice, master and slave, \nself-propelled, DMX512 \nChannels: 4 / SCH \nWorking temperature: -30 "C -40 "C \n+RGB Make -Canara/ Stage Works/ Illumitex/ Effectron 12 EACH
455 28.1 200W cob led studio par light with zoom\nInput Voltage: AC100-240V, 50-60Hz \nPower Consumption: 250W \nLED Quantity: 1 PCS 200W cool white or warm white LEDs Color Rendering Index: (CRI) Ra>90 \nZoom angle:10 ° to 90 ° \nControl Signal: DMX512, master-slave, sound, auto mode Control Channels\nMake -Canara/ Stage Works/ Illumitex/ Effectron 12 EACH
456 28.11 4 eyes cob led blinder light 100W\nVoltage / frequency: AC100V-240V/50-60Hz. \nRated power: 430W. \nLight source: 4 ultra-high brightness \nCOB 1 DOW two-in-one LED. \nLamp life: about 50,000 hours. \nColor: Warm white or white or 2-in-1. \nColor temperature: 3200K - 5600K can be adjusted. Control channel: 8 channels. \nLight angle: 35° . \nDimming: 0-100% linear electronic dimming. \nStrobe: Independent high-speed electronic strobe, 1-13 times per second. \nOperating mode: voice control, self-propelled, master­slave, DMX512. \nColor rendering index: Ra>85\nWaterproof rating: IP20 Make -Canara/ Stage Works/ Illumitex/ Effectron 6 EACH
457 28.12 200w fresnel light with barndoor\nInput voltage: AC100-240V, 50/60Hz \nPower: 220W \nLight source:100W/150W/200W high indicates COB LED lamp. \nColor rendering index: Ra>95 \nLight source life: 100000 hours \nColor temperature: 3200K, 5600K optional. \nControl panel: LCD liquid crystal display + four buttons Beam angle: 15-60 degrees Manual zoom \nDimming: 0-100% linear dimming. \nCooling method: copper radiator. \nChannel mode: 1 CH/2CH. \nControl mode: DMX512 control/manual control. \nProtection level: IP20 \nWorking temperature: -25° C- +45° C \nShell Material: Aluminum Alloy \nAccessories : Concealer, power cord, signal cable \nMake -Canara/ Stage Works/ Illumitex/ Effectron 2 EACH
458 28.13 200W LED profils\nInput Voltage: AC100-240V, 50/60Hz \nPower Consumption: 260W \nLED POWER: 200W \nLED Quantity; 1 PCS 200W white or warm white LED \nColor Temperature: 3200K or 5700K color temperature Color Rendering Index: (CRI) Ra>90 \nBeam Angle: 19° (26° /36° also available) \nControl Signal: DMX512, master-slave.auto mode Control Channel: 1/3CH DMX512 channel \nProduct Dimensions: 550•270•185m \nMake -Canara/ Stage Works/ Illumitex/ Effectron 2 EACH
459 28.14 LED 400W Strobe\nVoltage: AC 110 -220V 50-60HZ \nSignal: 512 Controllable Self-propelled \nControl channel: 5 channels \nCan match the brightness of 3000W \nLight source: 8 25W imported lamp beads, \nRGBW optional \nMake -Canara/ Stage Works/ Illumitex/ Effectron 4 EACH
460 28.15 200W LED COB Profile Spot\nBeam angle 15-60 degree optional\nMake -Canara/ Stage Works/ Illumitex/ Effectron 2 EACH
461 28.16 Follow spot 7R\nInput voltage / frequency: AC220V ± 10% / 50-60Hz. Rated power: 250W/280W. \nLight source: Use a 200W/230W cup. \nBeam angle: 15° . \nThe combination of new aluminum alloy and die-cast steel plate is beautiful and elegant. \nManual focus adjustment. \nThe aperture size is adjustable. \nAdjust the strobe manually. \ncolor: White. \nProtection level: IP20. \nMake -Canara/ Stage Works/ Illumitex/ Effectron 1 EACH
462 28.17 6eyes Red Laser Beam Bar Light,\nLaser power: 3000mW (500mW*6PCS)\nInput voltage / frequency: AC100V-240V, 50/60Hz. Rated power: 120W \nLight source: 500mW red laser tube 6 \nLaser color: single red / single blue / single green color optional \nCooling system: low noise air cooling \nOperating mode: voice control, self-propelled, master­slave, OMX512. \nScanning system: stepper motor \nScanning angle: ± 25 degrees \nOperating ambient temperature: 10-35° C \nProtection level: IP20. \nFeatures: long illumination distance, low power consumption, long life, uniform spot, simple operation and dazzling effect. Controllable via OMX \nOut of extraordinary magical lighting effects, 6 beams of light can be alone, horse racing, running water.\nMake -Canara/ Stage Works/ Illumitex/ Effectron 2 EACH
463 28.18 LED 1810W Non-waterproof Dot Matrix\nVoltage / frequency: AC100V-240V/50-60Hz \nRated power: 180W. \nLight source: 18 ultra-high brightness 10W RGBW 4 \nin 1 LED, optional 24, 36. \nLamp life: about 60,000 hours. \nColor: RGBW color mixing, bright colors, rich colors \nand bright, can combine 16,777,216 color changes. \nControl channel: 4/8CH. \nBeam angle: 25 ° , 15, 45 degrees optional. \nDimming: 0-100% linear dimming, no flickering, \nsmoothing and softening. \nStrobe: Independent high-speed electronic strobe, \n1-13 times per second. \nControl mode: DMX512, master-slave control, self­\npropelled, voice control. \nWorking environment temperature -20-45 ° C.\nWaterproof rating: IP64.Make -Canara/ Stage Works/ Illumitex/ Effectron 6 EACH
464 28.19 LED 108Pcs Spot Lights\nVoltage/ frequency: AC100V-240V/50-60Hz Rated power: 324W\nLight source: 108 ultra- high brightness 3W LED. Lamp life: about 60,000 hours.\nColor: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216color changes.\nCmtrol channe:l 6CH.\nBeam angle: 15, 25, 35, 45 degrees optional. Dimming : 0-100% linear dimming, no flickering, smoothing and softening.\nStrobe: Independent high-speed electronic strobe, 1-13 times per second.\nCmtrol mode: DMX512, master-slave control, se -propelled, voice control.\nWorking environment temperature -20-45 ° C.\nWaterproof rating: IP64\nMake -Canara/ Stage Works/ Illumitex/ Effectron 2 EACH
465 28.2 LED54/72/108/120Pcs Non-waterproof Flood Light\nRated power: 250W\nLight source: 54/72/108/120 high brightness and high power 3W LED.\nLamp life: about 50,000 hours.\nColor: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216 color changes.\nDimming: 0-100% linear dimming. Control channel: 6CH.\nBeam angle:15, 25 degrees optional.\nControl mode: DMX512, master-slave control, self­ propelled, voice control.\nProtection level: IP20.\nMake -Canara/ Stage Works/ Illumitex/ Effectron \n 6 EACH
466 28.21 Splitter 8 channel \n4/8 independent amplification driver output.The signal amplifying and shaping !unction, extending the signal \ntransmission distance.To enhance the capacity of data bus access equip men! number. To protect the lighting \nconsole DMX512 output interface.fault isolation, \nimprove the safety and reliability \nof digital lighting Make -Canara/ Stage Works/ Illumitex/ Effectron 3 EACH
467 28.22 Mini pearl 1024 lighting controller with flight case\n1. Audio signal input \n2. MIDI input or output \n3. Via RS 232 \nSystem interface \n4. DMX 512 signal 1024 channel Power supply: 25 V.DC 0.5A Make -Canara/ Stage Works/ Illumitex/ Effectron 1 EACH
468 28.23 DMX 3-Pin Male XLR – 3-Pin Female XLR DMX Cable:\nSupply, Installation, Laying, Testing & Commissioning of DMX Data Signal Point Wiring : Using 2-core PVC insulated 22AWG multi-stranded Cu.Cond. high speed data cable designed for EIA485 ; lowcapacitance, twisted pair shielded ; FHDPE insulation\n- starting from DMX Splitter to each Light Bar - either sides, Side Ladders and Floor Points, as required to be terminated with suitable XLR connectors Make -Canara/ Stage Works/ Illumitex/ Effectron 165 EACH
469 28.24 LIGHTING SAFETY HOOK\nFeatures\nChoose from multiple lengths and safety bond types\nGalvanised steel cable\nBlack PVC coated\nBlack steel cable\nScrew-gate carbine hook\nShackle\nDesigned and manufactured in the UK!\nSpecifications\nCable diameter: 3mm\nWorking Load Limit (WLL): 25kg Make -Canara/ Stage Works/ Illumitex/ Effectron 165 EACH
470 28.25 Black Steel Hook:\nG CLAMP\nStrong metal G clamp fitted with protector strip designed for hanging light effects. Fits on bars up to 50mm diameter.\nMake -Canara/ Stage Works/ Illumitex/ Effectron \n 330 EACH
471 29 "WATER COOLER AND REFRIGERATION"
472 29.01 Supply, install and testing water cooler electric driven (single phase) having storage cap of 150 ltrs and nominal cooling cap of 150 ltrs per hours complete all as per manufacturers instructions and as directed. Make : Blue Star/ Voltas 2 EACH
473 29.02 Supply and install Hi wall split Air conditioning indoor/outdoor complete with cordless remote control unit and within built Air IONISER and plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of 2 TR capacity. Make : Daikin/ Voltas/ Blue Star 2 EACH
474 29.03 Supply and fix voltage stabilizer capacity of 5 KVA for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 volt with output voltage stabilzer at 230 v with accuracy of + 2.5 % including high/low voltage cut out and time delay relay complete all as specified and directed. 2 EACH
475 29.04 Supply and fix voltage stabilizer capacity of 2 KVA for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 volt with output voltage stabilzer at 230 v with accuracy of + 2.5 % including high/low voltage cut out and time delay relay complete all as specified and directed. 2 EACH
476 30 " FURNITURE"
477 30.01 Supply and fix in position chair high back Model Jupiter PCH2342IX of Make: Godrej or equivalent in Durian, Methodex, Fetherlite as approved. 900 EACH
478 31 SERVICES FOR COMPREHENSIVE MAINTENANCE OF AC PLANT
479 31.01 Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of chilled water type central air conditioning plant of capacity 3 x 75 TR installed, comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below: at Auditorium Karwar
480 31.02 1st year after expiry of defect liability period. 12 Per Month
481 31.03 2nd year after expiry of work of Item No 31.02 above 12 Per Month
482 31.04 3rd year after expiry of work of Item No 31.03 above 12 Per Month
483 31.05 SERVICES FOR MANNING & OPERATION OF AC PLANT
484 31.06 Outsourcing of services for 2 shifts ( consisting of two shifts) including Sundays and holidays and operation of Central type air conditioning plant of capacity 3 x75 TR ( Two plants each to be run at a time and one will be kept as stand by) including all connected electrical items such as main switch, starter,change over switch, MCCB, voltmeter, ammeter, panel board etc, cooling tower,condenser or water pump ,valve system,controling system, condenser,refrigerant line,adjusting valve, refrigrant valve, bypass valve, daily checcking, leakage, checking noise, controlling temp. of plant,cleaning of plant and it's surrounding area etc, by one Ref Mech (Skilled) per shift for 02 shifts in a day all as per manufacturers instructions and as specified and directed by Engr-in-charge.
485 31.07 1st year after certified date of completion of work. 11 Per Month
486 31.08 2nd year after completion of work 31.07 mentioned above 11 Per Month
487 31.09 3rd year after after completion of work 31.08 mentioned above 11 Per Month
488 31.1 4th year after after completion of work 31.09 mentioned above 11 Per Month
489 31.11 5 th year after after completion of work 31.10 mentioned above 11 Per Month
490 31.12 6 th year after after completion of work 31.11 mentioned above 5 Per Month
491 31.13 NOTE:- (a) The contractor shall be responsible for periodical/routine maintenance, as per maintenance schedule recommended by manufactur/OEM, including renewal / replacement of parts, fittings / fixtures filling of refrigerant gas etc required for smooth functioning of the plant as per manufacturers instructions.the cost of all parts/componant/Gas required for replacement are considered inclusive in quoted rate
492 31.14 (b) The Contractor shall Employ Refrigeration mechanic having minimum ITI qualification from Govt Recognised institute with adequate knowledge & minimum 2 years experience in maint/operation of AC plants. The operator must competent to carry out the minor maint all as directed. (TOTAL number of operators required per day are 02 nos.)
493 31.15 (c) Contractor shall pay the wages to the employees through e-payment i.e Adhaar linked bank accounts (credit to their bank account). Engineer-in-charge shall ensure that e-payment made to employees and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engr-in-charge and the same shall be kept in record duly verified.
494 31.16 (d) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevailng scales as laid down by Ministry of labour for all operator/helper (as appliable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. The quoted rates shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing scale plus 15 percent. \n
495 31.17 (e) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department. \n
496 31.18 (f) Each shift duration shall be 8 hours & duty timing will be decided by Engr-in-Charge.\n
497 31.19 (g) The unit rate quoted shall deemed to be included for cost of labour for daily routine maintenance for trouble free functioning of installation.\n
498 31.2 (h) In case of any abnormal noise/ complaint the plant should be put off and same should be brought to the notice of Engr-in-charge.\n
499 31.21 (i) The operator employed by the contractor shall be capable of carrying out minor repair/ maintenance & should have well experience in AC plants as applicable.\n\n\n\n\n \n\n\n
500 31.22 (j) The quoted rate is deemed to be inclusive of cotton waste, cleaning material etc & Contractor will ensure general area cleanliness and upkeep of the installation on daily basis.
501 31.23 (k) The quoted rate is deemed to be inclusive of tools & testing instruments required for operation & maintenance of AC plants.
502 31.24 (l) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (spanner sets, hand gloves), a penalty of Rs 3000/- will be recovered and levied
503 31.25 (m) The Contractor shall not employ same tradesman continuously for more than 11 months during the Contract period.
504 31.26 (n) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved. In case of failure, a penalty of Rs 2000/- per uniform will be levied and recovered from their dues.
505 31.27 (o) In case of failure due to absence of operative staff, the contractor shall be liable to pay compensation at twice the cost of a day’s Manning & Operation derived from pro rate of Sch ‘A’ quoted rates.
506 31.28 (p) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly.
507 31.29 (q) The contractor shall provide board at proper location near each installations duly writting the name of operators and Mobile Numbers shifwise.
508 31.3 (r ) In case of non function of AC Plant panel recovery @ 3000 per day shall be effected 24 hrs after the defect is noticed or notified either in writing or through a social media message by GE or his rep.
509 31.31 (s) Any defect in to a motor , Pumps, compressure ,Control Panel ,AHU, Refrigarent Gas , Cooling Tower shall be considered as outstanding defect & Panel charge will be applicable as above in Note (r )