Military Engineer Services-MES has published Provision Of Fire Hydrant With Associated Facilities At Sre Complex At Af Stn Thanjavur. Submission Date for this Tender is 17-06-2021. Fire Suppression System Tenders in Thanjavur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

27308422
Corrigendum : Provision Of Fire Hydrant With Associated Facilities At Sre Complex At Af Stn Thanjavur
Open Tender
Indian
Tamil Nadu
Thanjavur
17-06-2021

Tender Details

Provision Of Fire Hydrant With Associated Facilities At Sre Complex At Af Stn Thanjavur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Apr-2021 Postponement1 of tender Date 20-04-2021
2 12-Apr-2021 Postponement 2 of tender Date 27-04-2021
3 20-Apr-2021 POstponement3 of tender Date 30-04-2021
4 22-Apr-2021 Postponement4 of tender Date 06-05-2021
5 29-Apr-2021 Postponement5 Date 14-05-2021
6 06-May-2021 Postponement6 Date 20-05-2021
7 11-May-2021 Postponment7 Date 27-05-2021
8 20-May-2021 Postponement8 of tender Date 03-06-2021
9 27-May-2021 Postponement9 of tender Date 10-06-2021
10 03-Jun-2021 Revision of BOQ BOQ 10-06-2021
11 10-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-06-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 201000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Provn of work services for Fire Hydrant system with associated facility at SRE complex at AFS Thanjavur
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Lump sum price worked out by the contractor for “BUILDING WORKS ” as listed in Sch ‘A’ Part I representing **___________%____________________________ only) *above / below the lump sum price of Rs 1650000.00 inserted by MES for Schedule ‘A’ Part I . 1 Lump sum
2 2 Lump sum price worked out by the contractor for “INTERNAL WATER SUPPLY ” as listed in Sch ‘A’ Part II representing **___________%____________________________ only) *above / below the lump sum price of Rs 3768.50 inserted by MES for Schedule ‘A’ Part II . 1 Lump sum
3 3 Lump sum price worked out by the contractor for “INTERNAL ELECTRIFICATION ” as listed in Sch ‘A’ Part III representing **___________%____________________________ only) *above / below the lump sum price of Rs 15106.10 inserted by MES for Schedule ‘A’ Part III . 1 Lump sum
4 4 Lump sum price worked out by the contractor for “(AREA DRAINAGE) ” as listed in Sch ‘A’ Part IV representing **___________%____________________________ only) *above / below the lump sum price of Rs 62127.03 inserted by MES for Schedule ‘A’ Part IV . 1 Lump sum
5 5 Lump sum price worked out by the contractor for “FIRE FIGHTING / SPRINKLER SYSTEM ” as listed in Sch ‘A’ Part V representing **___________%____________________________ only) *above / below the lump sum price of Rs 1442277.04 inserted by MES for Schedule ‘A’ Part V . 1 Lump sum
6 6 Lump sum price worked out by the contractor for “SITE CLEARENCE AND EARTH WORK ” as listed in Sch ‘A’ Part VI representing **___________%____________________________ only) *above / below the lump sum price of Rs 21410.54 inserted by MES for Schedule ‘A’ Part VI . 1 Lump sum
7 7 Sch 'A' Part- VII - MISCELLANEOUS ITEMS \n(Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
8 8 Supply and fix Foot Valve conforming to IS 4038,1986, Cast Iron body with leather flap sealing clamped on cast iron disc plates of size 150 mm (6”) dia complete all as specified and directed. 3 Each
9 9 S&F Installation of sprinkler valve set (Assembled set) comprising of following (ISI) UL listed items as under:- \n(i) Stop valve -01\n(ii) Alarm valve - 01 \n(iii) Pressure gauges - 02\n(iv) Test valve - 01\n(v) Drain valve - 01\n(vi) Alarm Gong (Water operated motor) - 01 1 Each Job
10 10 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia all as specified and directed. 1 Each
11 11 Masonary valve chamber internal size 75cmx75cmx75cm including 100mm thick PCC (1:4:8) type foundation, Brick work in CM (1:4), plastering internal surfaces completely and external surfaces upto 150mm below ground level, 15mm thick in CM (1:4) 100mm thick PCC (1:2:4) type C1 as in coping , fabricating MS cover made out of 40x40x5mm thick angle iron frame ,5mm thick MS plate, hinges, lifting handle. locking arrangements, complete including grouting in coping concrete, painting steel surfaces with two coats of synthetic enamel paint over one coat of zinc chrome primer complete all as specified and directed. 3 Each
12 12 Design, supply, install, test and commisioning of indoor LT panel confirming to IS-8683) AC 415V 50 Hz 3 phase 4 wire made out of 2mm thick CRCA sheet steel, powder coated,factory made, dust proof,vermine proof, index of protection not less than IP 43, floor mounted front operated cubical, bus bar and panel shuld be suitable for fully automatic operation on 3 phase 415 volts including internal wiring with suitable size PVC insulated copper conductor and accessoreies required for automatic operation of fire fire fighting system complete with the following:- \nIncoming:-\na) MCCB 250 Amps 4 pole 415 volts 35 KA fixed type - 01 No\nBubar:- \n400A TPN copper busbar with insulation sleeves\nMetering Unit:-\na) Digital voltmeter 0-500 volts with selector switch - 01 No. \nb) Digital Ammeter 0 - 400 Amps with selector switch - 01 No \nc) CT ratio 200:5 Amps copper wounded coil type - 01 Set\nd) RYB phase indicator lamps LED type - 01 set\nOutgoing:-\na) MCCB 125 Amps TP 415 volts 25 KA fixed type - 01 No's\nb) MCCB 40 - 63 Amps 4 pole 415 volts 25 KA fixed type - 02 No's\nc) Suitable Star Delta starter for fire pump's including suitable relay's 3 phase 415 V AC - 1 Nos d) 3 Ph DOL starter incl suitable relay for upto 10 HP for Jockey pump -01 No 1 Each
13 13 Supply, laying and testing 3.5 core ,95 Sqmm UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor with jointing accessories like suitable size of lugs and glands etc complete all as directed. Note: Qty of excavation and earthwork and removal of excavated soil shall be measured and paid under Schedule A Part VI 50 RM
14 14 Returning and filling of trenches in two parts (i) using riddled soil obtaine from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note :- (i) Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 8.58 cum
15 15 AUTO SPRINKLER SYSTEM BASED ON CLEAN AGENT LIKE PER-FLUORO-ETHANE/PENTA-FLUORO-ETHANE/HEPTA-FLUORO-PROPANE \nSupply , Installation , Testing and commissioning of Auto sprinkler system based on any of the clean agent like per-fluoro-ethane,penta-fluoro-ethane or hepta-fluoro-propane including fire alarm of following parameters as per customer requirements:\n1. FAS SERIES A-5000 - UL LISTED AEROSOL UNIT -10 Nos\n2. FAS SERIES A-1000 - UL LISTED AEROSOL UNIT- 06 Nos\n3.FAS SERIES A-500 - UL LISTED AEROSOL UNIT - 01 No\n4. FAS SERIES A-200 - UL LISTED AEROSOL UNIT - 01 No\n5. CONVENTIONAL 2ZONE UL LISTED GAS RELEASE PANEL WITH BATTARY BACK UP -04 Nos\n6. WEATHER PROOF HORN STROBE -01 No\n7. HORN STROBE -03Nos\n8. PHOTO ELECTRIC SMOKE DETECTOR WITH FLASHING LED -07 Nos\n9. HEAT DETECTOR WITH FLASHING LED - 07 Nos\n10. 5AMPS POWER SUPPLY PANEL WITH BATTARY BACK UP -04 Nos\n11. WARNING GAS RELEASE SIGNAGE - 04 Nos\n12. MANUAL ABORT SWITCH - 04 Nos\n 1 Each Job
16 15.1 13. MANUAL RELEASE SWITCH -04 Nos\n14. MANUAL CALL POINT - 03 Nos\n15. MANUAL CALL POINT SUITABLE FOR OUTDOOR INSTALLATION -01 No\n16. FRLS CABLE 2CORE X 1.5MM2 - 450 RM\n17. SEQUENTIAL ACTIVATOR - 18 Nos\n18. SYSTEM & COMPONENTS INSTALLATION, COMMISSIONING & INTEGRATION ALONGWITH PANEL TESTING & HANDOVE OF SYSTEM - 04 Nos\n19. Other accessories/Powder coating charges/transport charges - 1 Job
17 16 Trial bore of 200 mm dia upto 200meter depth below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc. 120 RM
18 17 Development of successful bore well by compressor and removing the fine sand ,rock particles and other dust items etc. complete all as specified and as directed. 5 Per Hour
19 18 Development of trial bore by reaming up to 525 mm for 60 RM from ground level including casing pipe of 200mm dia and thickness 8mm and pea gravel all as specified and directed. 60 RM
20 19 Development of trial bore by reaming Reaming up to 525 mm from depth exceeding 60 RM to 200 meter including slotted casing pipe of 200mm dia and thickness 8mm and pea gravel complete all as directed. 61 RM
21 20 Supply & filling of gravel pack provided in fine aquifiers of suitable size around bore well casing pipe upto ground level as directed. 5 cum
22 21 Yield test for the bore well by continuously pumping for 16 hours to determine safe pumping yield all as specified and directed. 1 Each Job
23 22 Supply & fixing of MS reducer, bail plug, well cap, MS strip for centering, MS iron clamps, electric logging and sample strata box complete all as directed. 1 Each Job
24 23 S&F flat submersible cable of size 6 sq mm 3 core PVC insulated and sheathed multistranded 1100 V grade copper conductor all as specified and directed. 100 RM
25 24 Supply, install, and commisioning Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm)complete upto 15 WHP inclusive of 40 metre long submersible cable and starter and directed. 1 Each Job
26 25 S&L flanged Pipe galvanized `Heavy class' complete including all joining accessories of size 65mm with slots cut in the flanges to accommodate submersible cable (for lowering submersible pump set) including flanged joints at every 10 ft of pipe all as specified and directed 90 RM
27 26 Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point , Earth PCC earth pit, RCC cover and earth work and protection pipe and watering pipe complete all as specified or indicated including testing on completion. 6 Each Job
28 27 M & L for Cutting opening in cement concrete walls (any description) for fixing of 100 mm MS pipe and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, and Rendering 10mm thick cement plaster ( 1 : 4 ) on fair faces of brick work or concrete surfaces all as specified and directed. 7 Each Job
29 28 S & F of Dry Chemical Powder Modular Type Automatic Fire Extinguisher 10 Kg Capacity,Powder Coated MS Body, Fitted With Heat Sensitive Glass Bulb Sprinkler, Pressure Gauge, Filled With BC Or ABC Powder Complete With All Accessories installed above the transformer in transformer room. \n 1 EACH
30 29 S & F heavy duty exhaust fan 300mm sweep, speed 1400 RPM, corrossion less mild steel body of motor, plastic/fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, 230/240 volts single phase complete including making opening of suitable size of wall, grouting bolts and making good the distrubed surfaces and connection with 1.5 sqmm copper conductor flexible wire from ceiling rose to fan complete all as specified and directed. 1 EACH
31 30 Supply and fix new energy efficent LED tube lightr 1 x 20 watts 4 feet long CRCA body powder coated white batten type MCL LED type all prewired with LED tube 20 Watt and driver including connection with twin core flexible PVC 0.5 Sqmm complete all as directed. 5 EACH
32 31 Supply & fix energy efficient BLDC ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230volts AC 50 Hz, single phase including provision of fixing arrangement , nut and bolt and flexible 3 core of size 1.5 sqmm not less tha 0.5mtr long with all accessories complete all as specified and as directed. 1 EACH
33 32 Supply and fix high power LED 20 W die-cast aluminium IP66 PDC Security light luminiare including Fabrication and fixing of building light bracket made of 40 mm dia GI tubing light grade, 1.5 metres long, bent to shape fixed to wall with 50mm x 6mm GI clamps incl two run of 1.5 Sqmm PVC insulated sheathed copper conductor cable from ceiling rose to Security light fittings drawn through wall complete all as specified and as directed. . 3 EACH
34 33 Supply & Fix MCB SPN 25Amp, 10 KA repturing capacity, 230 V, 50 Hz AC, complete all as specified and directed. 1 EACH
35 34 Supply & Fix MCB SP 6-32Amp, 10 KA repturing capacity, 230 V, 50 Hz AC, complete all as specified and directed. 6 EACH
36 35 M&L for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate not less than 1.5mtrs below ground level connected with galvanized earth lead 4mm dia by means of bolts, nuts, check nuts and washers of galvnaized iron, etc protected by GI Pipe light grade 15mm bore and 20mm dia GI tubing light grade with funnel for watering connceting to test point,, all as shown in electrical plate No 3 of SSR Part -I incl necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, one provn of test point complete all as specified and directed. 1 EACH
37 36 Supply,Install and testing Jockey pump horizontal end suction centrifugal type, pump directly coupled with motor with proper coupling guard Confirming to IS- 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with non over loading power characteristics for frequent start / stop operations for 440 V, 3 phase, 50 Hz 70 m head 180 LPM discharge,operating speed for the pump shall be 2900RPM. Jockey pump motor shall be totally enclosed fan cooled (TEFC), copper wound for class 'B' insulation mounted as per the OEM direction. 1 EACH
38 37 Supply,Install and testing Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS - 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V, 3 Phase,50 Hz 70m Head, 2280 LPM discharge, operating speed for the pump shall be 2900RPM. Fire pump motor shall be totally enclosed fan cooled (TEFC),copper wound class 'B' insulated mounted as per the OEM direction. 1 EACH
39 38 Supply,Install and testing Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS - 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V, 3 phase, 50 Hz AC supply 70 m Head. 2280 LPM discharge mounted as per the OEM direction. 1 EACH