Name of Work: PROVN OF ETP AND ASSOCIATED WORKS AT 7 AFH KANPUR CANTT | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Lumpsum price worked out by the contractor for"BUILDING &STRUCTURES”as listed in Sch ‘A’ Part I on Sl. Page No.18 (Price to be quoted by contractor base on drgs and specification). Brief discription of works to be executed at site are comprising as followings :-\n(a) Supply, installation, commissioning and testing of effulent treatment plant based on principle of aerobic attached growth non clogging randomly moving bed bioreactor having capacity 220Cum/hours including all civil/mechanical/electromechanical/electrical and other miscellaneous works as specified herewith and particular specifications so as to achieve the parameters mentioned elsewhere in the tender documents from any one of the OEMs civil work in the item include ETP, plant room and sludge drainage bed as described in drawing and here in after.( Make : (a) Thermax Ltd. (b) Fontus water Ltd. (c) Hydrotech paryavaran (d) Optimus Enviropro Pvt. Ltd. (e) Nitasha Constructions (f) M/s SIMA Labs Pvt. Ltd. New Delhi (g) M/s Sombanshi (SEEPL) as approved by GE). \n\n\n | 1 | EACH \nBLOCK | |
2 | 1.01 | (b) DESIGN DATA: (A) . EFFLUENT TYPE: Description Parameters: Type of waste Domestic waste\nTotal waste 200KLD, Operation Hour 20 Hour, Stage of treatment 03(Primary, secondary, tertiary), Use of treated water Gardening Firefighting\n | |||
3 | 1.02 | (B). INLET EFFULENT PARAMETERS : Description Parameters PH 6.5-8.5, TSS 200-350 mg/l, Oil & Grease 30-40 mg/l, BOD 200-450 mg/l, COD 400-800mg/l, FC MPN as per design criteria\n | |||
4 | 1.03 | (C). DESIRED TREATED WATER : Description Parameters PH 6.5-8.5, TSS <10 mg/l, Oil & Grease <5 mg/l, BOD <10 mg/l, COD <100 mg/l, FC MPN <230/100 ml, Helminth egg <1 egg/l\n | |||
5 | 1.04 | (D) PROCESS DESCRIPTIONS : In order to conserve water, the treatment plant shall be verified to ensure that treated effluent (water) characteristics are well below the permissible limits, even under varying flow conditions which are typical for such systems. This implies that the selected process shall be able to withstand the stock load situation. It is proposed to use aerobic treatment system working on the principle of attached growth concept using MBBR bioreactors. The treatment plant shall be designed with a capacity to handle 200 KL/day of wastewater. Wastewater will flow via pumping system from an existing sewage well into setling tank. Sewage will be discharge from setling tank to the bar screen chamber by gravity. Automatic level controller shall be provided in the sewage collection sump pit to turn the pump off at the low sewage level in the sump pit and to start the pump automatically when water level is high in the sump pit in case water level in sump pit continues to increase. The second submersible pump shall start automatically till the water level in the sump pit attains normal level. In case the sewer is collected first in the sewage collection sump pit instead of equalization tank, a continuous increase in water level(in case of failure of pumps) will trigger a high level alarm, indicating pumping problems.\n | |||
6 | 1.05 | (E) BAR SCREEN : Bar screen should be so designed that it can be cleaned manually there shall be minimum two bar screen to facilitate the cleaning of the bar at designed interval of time. The raw sewage from bar tank waste water from bar screen chamber shall flow by gravity into equalization tank. In equalizing tank the variations in flow and characteristics are dampened, which otherwise can lead to operational problems and moreover it allows a constant flow condition by means of coarse air bubble diffusion.The equalized sewage from equalization tank shall be then pumped into the MBBR(Moving Bed Bio Reactor where BOD/COD reduction is achieved by virtue of aerobic microbial activities ). The oxygen required will be supplied through coarse air bubble diffusers.\nFrom the MBBR reactors this effluent passes into the secondary tube settler/clarifier. Though the use of baffles the liquid in the tube settler/clarifier tank is maintained in quiescent condition, which allows the solids to settle to the bottom for collection for the moving bed media system\n | |||
7 | 1.06 | (F) MEDIA SYSTEM : The accumulating solids known as “Sludge” shall flow at periodic intervals through the pumps from the clarifier tank bottom to the sludge drying bed. The primary and secondary tube settler/clarifier as per design requirement shall be provided with overflow weir to collect the treated effluent and scum baffle shall keep any floating matter from passing out in the final treated water for the fixed media system. The tube settler to be designed in fin on the basis of rate velocity of 2CUM/hour and 12MWC in clarifier. (Self priming C-type) treated water form secondary clarifier shall over flow into baffled chlorine contact tank where hypochlorite solution shall be added to disinfect the treated water. From sludge drying bed Waste water will be sent to raw sewage well through GI pipe 100mm/dia channel heavy duty. | |||
8 | 1.07 | (G) BLOWERS AND AERATION SYSTEM :The treatment plant shall be provided with rotary positive displacement blowers with a common base and a central electric control panel belt drive system drip proof induction type electric motor necessary valves and intake and discharge silencing. Each blower motor unit shall be housed in an enclosure. All piping and related accessories necessary to connect the blowers to the plant air header shall be provided by the plant manufacturer. All air piping from the blower motor unit to the air header shall be approved G.I pipe the dia of G.I.Pipe from pump to header shall be 80 mm heavy grade. The further air distribution pipe shall be stainless steel 304 grade 40mm dia the space between coarse/fine bubble diffuser shall be such that entire surface of tank should be covered. The air piping form the blowers shall be connected to the diffusers placed at the bottom of the Bio Reactors/Sump Pit if required /equalization Tank/Sludge holding tank/ Flushing water holding tank | |||
9 | 1.08 | (H) ELECTRICAL CONTROLS : The control system shall include circuit breakers, motor, starter and timers all housed in a weatherproof chubicle type panel board. | |||
10 | 1.09 | (J) CABLES (LT/HT) : Cables from DB to motors shall be PVC insulated amored cables to be laid in trays. All wiring shall be sized according to the National Electric code standards. No splice shall be permitted in the service wire. It shall also be the responsibility of the contractor to furnish and install all required exterior disconnects, switching mechanisms, alarm or control conduit and wiring. The specifications of the control panel/DB would be as per tender specifications or manufacturer’s design subject to approval. The branch circuit shall be short circuit protected by thermal magnetic air circuit breakers. All control circuit breaker. A magnetic across the line starter with overload heaters in each phase and common trip contact set shall be provided for each blower motor to give positive protection against single phasing motor insulation shall be class ‘B’ insulation and the design shall be such that the maximum permissible temperature for the insulation is not exceeding when the motor operates at service factor load in 45’C ambient on full load condition. All motors shall have anti-friction ball bearing sized an average life of at least as per motor manufacturer ltd under V-Belt loading conditions the control equipment starters, circuit breakers and switches shall be installed in an IP-42 enclosure with a suitable door latch. The mechanical/electrical system shall be designed to withstand ambient temperature range 45’C. | |||
11 | 1.1 | (K) FLOW DIAGRAM : Incoming sewage : Effluent transported by sewer lines into sump well, Bar screen chamber, Equalization tank, Flash mixer & flouculator, Anoxic tank, Primary settling tank, MBBR Reactor I & MBBR Reactor II Secondary tube settler->, Buffer tank followed by tertiary treatment by ACF, MGF & Ultrafilteration (Incase refused treated water), Disinfection treatment by 03 nation, Treated water tank, for reuse & disposal (as per norms) | |||
12 | 1.11 | (L) ELECTRO-MECHANICAL EQUIPMENTS : Effluent treatment plant (ETP) based on attached growth concept (with air diffuser membrane system) MBBR with 2 reactors in series with sewage handling capacity of 200 m3/day. The raw sewage comprises of effluent from entire residential and official campus of 7 AF Hospital Kanpur cantt for which a common ETP has to be designed. The stilling tank with bar screen shall be a part of the ETP. The ETP shall be designed as water retaining structures in RCC with RCC top structure and M.S epoxy coated. Non-skid type. Removable manholes covers including piping, valves, necessary chemical dosing as required by the manufacturer’s design. All the equipments, piping, pumps, air blowers and electrical are to be housed in a plant room underground/over ground including MS puddle flange/insert need to be hot dipped galvanized, inlet, outlet, overflow, vents, MS covers, drain channel with MS gratings etc. | |||
13 | 1.12 | The ETP shall be designed based on the following parameters :\n(A) INLET EFFLUENT PARAMETERS: Description Parameters : PH 6.5-7.0, TSS 200 mg/l, Oil & Grease 40-50 mg/l, BOD 400 mg/l, COD 200mg/l, FC MPN very design | |||
14 | 1.13 | (B) DESIRED TREATED WATER : Description Parameters : PH 6.5-8.5, TSS <10 mg/l, Oil & Grease <5 mg/l, BOD <10 mg/l, COD <100 mg/l, FC MPN <230/100 ml, Helminth egg <1 egg/l,\nNOTE: however the plant should be able to perform at lower range of above parameters | |||
15 | 1.14 | (C) ETP UNITS : The ETP shall consist of following units but not limited to these units as may be required by the manufacturer’s design:\n(i) Stilling chamber to reduce the velocity after being received from pump.\n(ii) Bar screen cum Grit chamber for the incoming sewerage from building SS frame. Manually cleaned SS bar screen. Having provision for lifting, etc.\n(iii) Oil & Grease Trap for kitchen waste to remove O & G with baffles need to be provided including MS manhole cover for total effluent of 200 KLD.\n(iv) Main Equalization Tank for collection of total effluent including effluent waste. Housing the pumps provision for aeration shall be kept to avoid any smell problem.\n(v) Moving bed bioreactor with PVC media including air diffusers at the bottom, sewage distribution header & baffle wall towards the outlet of the reactor.\n(vi) Settling Tank suitable for 200cum/Day fitted with PVC plates or tube deck media in series at 60 deg. Angle increasing the settling area and removal of the particles effectively in a smaller plan area.\n(vii) Chlorine contact cum filter feed tank for chlorine mixing and desired minimum volume.\n(viii) PVC hypochlorine solution tank (cap 100 litres) with dosing pump of suitable capacity adjustable metering type\n(ix) suitable size of treated water (flushing/irrigation) soft water and sludge holding trank.\n(x) Air diffusion system with 2 nos twin –type rotary air blowers (1 working + 1 standby) of suitable ETP capacity for 200 m3/day and necessary piping including air dispersion grid as given in specification for MBBR reactors and equalization Tank | |||
16 | 1.15 | (D) BAR SCREEN : Providing and fixing 2 nos SS Bar Screens in the Screen Chamber of the sewage treatment plant- 01 set size 500mm x 600mm (approx) or as per drawing mesh size 8mm & 10 mm. | |||
17 | 1.16 | (E) PUDDLE FLANGES & INSERTS : Supplying, installation testing and fixing of MS Puddle flange/Inserts plates need to be hot dipped galvanized shall be in the scope of the sewerage treatment contractor- 01 set | |||
18 | 1.17 | (F) SEWAGE TRANSFER PUMPS (COLLECTION. PIT) : Providing and fixing non-clog. Open impeller type fully submersible pumps in the existing collection pit. The pump shall be complete in CI construction with cutter arrangement including lifting arrangement for the pumps including piping, valves on the discharge of pumps, level controllers, probes cable etc, including connection to ETP. | |||
19 | 1.18 | (G) SUBMERSIBLE PUMPS OF OF COLLECTION PIT : Submersible Pumps- 30 m3/hr @ 15 mtrs head- 02 nos ( 1 working + 1 standby) complete with star delta starter, overload protection single phase preventer with each pump set. | |||
20 | 1.19 | (H) SEWAGE TRANSFER PUMPS (EQUALIZATION TANK) : Providing and fixing non-clog, open impeller type fully submersible pumps in the equalization tank. The pump shall be complete in CI construction with cutter arrangement including lifting arrangement for the pumps including piping, valves on the discharge of pumps, level controllers, probes, cable, etc. including connection to ETP. | |||
21 | 1.2 | (J) SUBMERSIBLE PUMPS OF OR EQUALIZATION TANK : Submersible pumps 10 m3/hr@ 12 mtrs head (I working +1 standby)-02 nos complete with star delta starter overload protection, single phase preventer with each pump set | |||
22 | 1.21 | (K) AIR DISPERSION SYSTEM : (i) Twin Rotatory Air Blower Head- 0.5 Kg/cm2 Capacity as per requirement (min- 300.0cum/hr) with motor driven through ‘V’ belt or directly coupled through flexible coupling to a TEFC motor of suitable HP suitable for 415 + 10% volts, 3 phase, 50 cycles A/C- 02 Nos complete with star delta starter, overload protection, single phase preventer with each pump set.\n(ii) Provision of Coarse Bubble Diffuser non clog type air dispersion system capable of handling. Air dispersion system shall be provided for raw sewage equalization tank & sludge holding tank. 20 Nos.\n(iii) Provision of Fine Bubble Diffuser non clog type air dispersion system capable of handling desired cfm of air. Air dispersion system shall be provided for raw sewage equalization tank & sludge holding tank 32 Nos. | |||
23 | 1.22 | (L) FITTER FEED PUMPS : Providing and fixing Horizontal centrifugal pumping set for filter feed pumps and discharging into the treated water tank. The pumps shall have CI casing Bronze impeller- EN 8 shaft with key with mechanical rotary shaft seal connected by a flexible tier type coupling to a TEFC induction induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia pressure gauge, GM isolation cock, suitable vibration eliminator, pads of approved design motor to be suitable for 400/440V, 3 phase, 50 cycles AC power supply, including all necessary piping, valves and other accessories from ETP to filtration units and treated water tanks.\n(i) capacity 15.0m3/h @ 30-35 mtr head- 02 Nos | |||
24 | 1.23 | (M) SLUDGE TRANSFER SUITABLE FOR MBBR SYSTEM :Providing and fixing horizontal, centrifugal sludge lifting pump to transfer sludge form SST to sludge drying bed. The pumps shall have CI casing impeller- shaft with mechanical rotary shaft seal connected by a flexible tier type coupling to a TEFC induction motor mounted on a common channel base- plate with coupling guard, 150mm dia pressure gauge, GM isolation cock, suitable vibration eliminator, pads of approved design Motor to be suitable for 400/400V, 3 phase, 50 cycles AC power supply. Including all necessary piping from pump to outside of suitable size 50mtr (approx) length of suitable size to unload the sludge into a tanker as instructed by site-in-charge complete in all respect.\n(i) Capacity : 5.0 m3/hr @20m head for MBBR System- 02 Nos | |||
25 | 1.24 | (N) MULTI GRADE SAND FILTER: (SUITABLE FOR 200.0M3/DAY) : Providing, fixing, testing & commissioning of vertical pressure sand filter fabricated from MS sheet with rubber lining as per manufacturer’s specification with GI frontal piping including vlaves to providing service, backwash and rinsing operation. Complete with initial charge of filter media. Including Anthracite-01 set \nshell Thickness- 06mm, Dish end- 8mm, Filtration rate- 15m3/hr/m2, Test pressure- 5.5 Kg/cm2, Capacity 15000Ltr/Hr | |||
26 | 1.25 | (O) ACTIVATED CARBON FILTER: (SUITABLE FOR 200.0m3/DAY) : Providing and fixing vertical MS make activated carbon filter with rubber lining of (Iodine value not less than 1000) as filter media. The shell shall be complete with initial charge of filter media GI frontal piping, complete including valve for service, rinse & backwash alongwith other accessories-01 set\nShell Thickness – 6 to 8 mm, Dish end - 8 to 10 mm, Filtration Rate - 12m3/hr./m2, Test pressure - 5.5Kg/cm2, Capacity - 15000ltr/hr | |||
27 | 1.26 | (P) ALL INTERCONNECTING PIPELINES, FITTINGS AND ISOLATION : control valves for making the system complete – 01 Nos, Hypo Dosing Pumps having capacity of 0-6 LPH metering type with dosing tanks of 100 lits- 02 Nos | |||
28 | 1.27 | (Q) CONSTRUCTION OF CONTROL PANEL ROOM : Construction of control panel room with duty room & toilet Contruction of control panel room with duty room & toilet complete all as shown on drgs and all as specified - 01 Each Block | |||
29 | 1.28 | (R) CONSTRUCTION OF RCC SUMP : Contruction of RCC sump for storage of capacity 45000 litres complete all as specified and shown on drgs - 01 each Block. | |||
30 | 1.29 | (S) MBBR Technology : Supply, installation, testing & commissioning of random, media for attached growth process (MBBR Technology) MOC= PVC, Specific Gravity= 0.93- 0.95, surface area= 500 sqr.mtr/cum.mtr- 15 cum in each tank- 02 Nos | |||
31 | 1.3 | (T) PVC TUBE DECK SETTLING MEDIA : Supply, installation, testing and commissioning of PVC tube deck settling media to be installed in secondary settling tank-7.50 Cum Pump for treated water 02 Nos. | |||
32 | 1.31 | (U) FRP COATING : 4 mm thick FRP coating shall be provided in both faces of baffle wall/partitions and equalization tank as per standard specification and conforming to IS. | |||
33 | 2 | Lumpsum price worked out by the contractor for “SITE CLEARANCE, EXCAVATION & EARTHWORK ” as listed in Sch ‘A' part II representing above / below the lumpsum price of Rs. 4,72,865.72 as inserted by MES for Sch ‘A’ Part II on Sl. Page No 35. | 1 | EACH | |
34 | 3 | Lumpsum price worked out by the contractor for“ROAD & PATH ” as listed inSch ‘A' Part III representing above / below the lump sum price of Rs 87,692.10 as inserted by MES for Sch ‘A’ Part III on Sl Page No.36 | 1 | EACH | |
35 | 4 | Lumpsum price worked out by the contractor for 'EXTERNAL WATER SUPPLY' as listed in Sch ‘A' Part IV repersenting above/below the lump sum price of Rs 34,605.52 as inserted by MES for Sch ‘A’ Part IV on Sl Page No 37 . | 1 | EACH | |
36 | 5 | Lumpsum price worked out by the contractor for 'EXTERNAL ELECTRIC SUPPLY" as listed in Sch ‘A' Part V repersenting above/below the lump sum price of Rs73,947.02 as inserted by MES for Sch ‘A’ Part V on Sl Page No 38 . | 1 | EACH | |
37 | 6 | Lumpsum price worked out by the contractor for 'EXTERNAL SEWAGE DISPOSAL ' as listed in Sch ‘A' Part VI repersenting above/below the lump sum price of Rs 17,112.95 as inserted by MES for Sch ‘A’ Part VI on Sl Page No 39 . | 1 | EACH | |
38 | 7 | Lumpsum price worked out by the contractor for 'AREA DRAINAGE ' as listed in Sch ‘A' Part VII repersenting above/below the lump sum price of Rs 20,957.96 as inserted by MES for Sch ‘A’ Part VII on Sl Page No 40 . | 1 | EACH | |
39 | 8 | Lumpsum price worked out by the contractor for 'SECURITY FENCING AND GATE ' as listed in Sch ‘A' Part VIII repersenting above/below the lump sum price of Rs 46,203.88 as inserted by MES for Sch ‘A’ Part VIII on Sl Page No 41 . | 1 | EACH | |
40 | 9 | Lumpsum price worked out by the contractor for 'INTERNAL WATER SUPPLY ' as listed in Sch ‘A' Part IX repersenting above/below the lump sum price of Rs 9,483.00 as inserted by MES for Sch ‘A’ Part IX on Sl Page No 42 . | 1 | EACH | |
41 | 10 | Lumpsum price worked out by the contractor for 'INTERNAL ELECTRIFICATION ' as listed in Sch ‘A' Part X repersenting above/below the lump sum price of Rs 6,429.50 as inserted by MES for Sch ‘A’ Part X on Sl Page No 43 . | 1 | EACH | |
42 | 11 | SCH'A' PART-XI ( MISC E&M AND B&R ITEMS)\nM&L MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 6 KA, 6 to 32 Amp complete all as specified. | 4 | EACH | |
43 | 12 | M&L MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, 16 to 32 Amp complete all as specified. | 1 | EACH | |
44 | 13 | S&F Exhaust fan 300 mm sweep, heavy duty, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed in position by using 4 Nos suitable size fasteners complete all as specified. | 1 | EACH | |
45 | 14 | S&F Exhaust fan 600 mm sweep, heavy duty, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed in position by using 4 Nos suitable size fasteners complete all as specified. | 1 | EACH | |
46 | 15 | S&F LED tube light fitting 1 x 18 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 1700 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin. complete all as specified. | 1 | EACH | |
47 | 16 | S&F LED light fitting 1 x 3 watt including LED tube complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 351 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin.complete all as specified. | 3 | EACH | |
48 | 17 | S&F LED light fitting 1 x 25 watt including LED tube complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 351 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified. . | 1 | EACH | |
49 | 18 | M & L construction of valves chamber 75 x 75 x 75 cm internal dimension, 6mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40x40x6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6) 230 mm thick, PCC bed (1:4:8) type D2 150mm thick, cement plastering, finishing 15 mm thick in CM(1:4) and applying a coat of black bituminous paint to the steel surfaces all specified and directed. | 1 | EACH JOB | |
50 | 19 | M & L Earthing complete with galvanised iron earth plate electrode of size 60 x 60 x 0.60 cm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32 X 6 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I complete. | 1 | EACH SET | |
51 | 20 | M & L Earthing complete with copper earth plate electrode of size 60 x 60 x 0.60 cm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including Cu strip 20 X 3 mm (upto the body of equipment) by means of Cu bolts/nuts/washers, protected by 40 mm bore Cu light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore Cu light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I complete. | 2 | EACH SET | |
52 | 21 | M & L Earthing complete with galvanised iron earth plate electrode of size 60 x 60 x 0.60 cm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 25 X 4 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I commplete\n \n | 2 | EACH SET | |
53 | 22 | M&L laying jointing & testing HDPE DWCP (SN*) conforming to IS016098 150 mm nominal bore 172 mm OD) complete laid in trenches and jointed including testing alongwith necessary jointing material sockets ring & aditive etc | 216 | RM | |
54 | 23 | M & L 15 mm thick cement plaster in cement mortar (1:3) with water proofing compound @ 3 % by weight of cement two or more coats of epoxy coating on all internal surfaces of RCC walls complete all as specified & directed by Engineer-in-charge. | 127.96 | SQM | |
55 | 24 | M & L 15 mm thick cement plaster in cement and sand mortar (1:4) in two layer i:e first layer shall be 10 mm thick & other layer shall be 5 mm thick with water proofing compound @ 3 % by weight of cement shall be provided to external surfaces of all buildings unless other-wise specified complete all as directed by Engineer-in-charge. | 29.04 | SQM | |
56 | 25 | S&F SFRC FOOT REST made out in PCC 1:2:4 type B- 0 using 12.5 mm graded stone aggregate of size 350 X 230 X 150 mm completed all as specified and directed by Engineer-in-charged. | 25 | Each | |
57 | 26 | M & L Design suppply and fixing of manual cleaning contineous rake type coarse Bar Screen suitable for site. Bar to bar gap will be 28mm C/C & 20mmC?C, Thickness of bar will be 8mm sq bar with ISA 14*14*6 mm SS Angle and 3mm thick SS perforated sheet as per desing complete in all respect. Moc-SS304 (For Sump well)\n(i) 28 mm C/C bar size 1000x650 01 set (ii) 20 mm C/C bar size 1000 x 650 01 set | 1 | Each | |
58 | 27 | Supply and fixing testing & commissioning including following but not limited to, complete in all respect, PRE MOULDED FRP tank of capacity 50,000 litres capacity with minimum thickness of 10 mm including 03 nos 550 Internal Dia Shaft with Main Hole Cover ( Tanks For 01 Equalization Tank & 02 Treated water Tank)\n(A) Material of Construction : FRP (B) The pump shall be consist of following features : With supportive plate form and necessary steel structure complete.\n | 1 | Each | |
59 | 28 | S&F Providing, fixing, testing & commissioning of fully submersible, centrifugal non-clog type sewage handling pump capable of handling solids upto 30-35mm for raw sewage transfer from sumpwell to EQT tanks and by pass the sewage to municipal sewer at the time of maintenance . The pump shall have construction (C.I casing & C.I impeller, SS shaft), TEFC induction motor including pressure gauge, lifting arrangement for the pump, all necessary piping (flexible pipe with coupling), delivery header valves, level controller, probes, cable, control panel etc. and other accessories as required (1 working+ 1 standby) at Sump Well, Capacity/Flow Rate - 30.0 M3/Hr, Head - 15 m Note: Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the contractor complete. | 2 | Each | |
60 | 29 | Supply, fixing, testing & commissioning of fully submersible, centrifugal non-clog type sewage handling pump capable of handling solids upto 15-20 mm for raw sewage transfer from EQT to Flsh Mixer . The pump shall have construction (C.I casing & C.I impeller, SS shaft), TEFC induction motor including pressure gauge, lifting arrangement for the pump, all necessary piping (flexible pipe with coupling), delivery header valves, level controller, probes, cable control panel etc. and other accessories as required (1 working+ 1 standby) at Equlization Tank Capacity/Flow Rate - 10.0 M3/Hr, Head - 12 m Note: Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the contractor complete. | 1 | Each | |
61 | 30 | Supply, fixing, testing & commissioning of fully submersible, centrifugal non-clog type sewage handling pump capable of handling solids upto 15-20 mm for raw sewage transfer from EQT to Flsh Mixer . The pump shall have construction (C.I casing & C.I impeller, SS shaft), TEFC induction motor including pressure gauge, lifting arrangement for the pump, all necessary piping (flexible pipe with coupling), delivery header valves, level controller, probes, cable control panel etc. and other accessories as required (1 working+ 1 standby) at Equlization Tank Capacity/Flow Rate - 10.0 M3/Hr, Head - 12 m Note: Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the contractor complete. | 2 | Each | |
62 | 31 | Supply, fixing, testing & commissioning of fully submersible, Open well type clear water pump for feed clear to MGF and ACF from filter feed tank . The pump shall have construction (C.I casing & C.I impeller, SS shaft), TEFC induction motor including pressure gauge, lifting arrangement for the pump, all necessary piping , delivery header valves, level controller, probes, cable control panel etc. and other accessories as required (1 working+ 1 standby) at Filter Feed Tank Capacity/Flow Rate - 12.0 M3/Hr, Head - 35 m Note: Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the contractor complete. | 2 | Each | |
63 | 32 | Supply fixing, testing & commissioning of fully submersible, Open well type clear water pump for water supply from treated water tank . The pump shall have construction (C.I casing & C.I impeller, SS shaft), TEFC induction motor including pressure gauge, lifting arrangement for the pump, all necessary piping , delivery header valves, level controller, probes, cablecontrol panel etc. and other accessories as required (1 working+ 1 standby) at Treated Water Tank Capacity/Flow Rate - 20.0 M3/Hr, Head - 55 m Note: Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the contractor complete. | 1 | Each | |
64 | 33 | Supplying of Self Priming Non-Clog Pump Sludge Recirculation coupled with motor of C.I. Parts and mechanical seal complete with isolation and non-return valves ,(C.I casing & C.I impeller, SS shaft), including TEFC induction motor pressure gauge, delivery header valves, level controller, cable control panel, wether cover etc. and other accessories as required (1 working + 1 standby) Capacity/Flow Rate - 1.5 M3/Hr, Head - 12M Location Near Tube Settler complete. | 2 | Each | |
65 | 34 | Supply, installation, testing & commissioning of Positive Displacement Type Screw Slurry Pump with M.S Casing, S.S-Strator with internal Rubber Lining, Gland Packing Seal, Solid handling capacity upto 7 to 10% of the effective percentage of Sludge and direct drive with Motor. including TEFC induction motor pressure gauge, delivery header valves, level controller, cable control panel, wether cover etc. and other accessories as required (1 working + 1 standby) Capacity : 1.5 m3/hr Head : 40 mtrs complete. | 2 | Each | |
66 | 35 | Supply and fixing testing & commissioning including following but not limited to, complete in all respect, ,Srew Press including TEFC induction motor, pressure gauge, cable control panel, wether cover etc. and other accessories as required \nOut Put: 1 – 2 m³/h\n20 – 30 kgDR/h\nPolymer demand: 3 kg/t; 1:1 mix of powder/liquid\nDewatering results: 24 – 27 % DR\nSeparation degree: > 97 %\nScrew rotation speed: 0.3 - 0.4 rpm\nPower consumption: 0.5 – 0.8 kW\n | 1 | Each Job | |
67 | 36 | Supply and fixing testing & commissioning including following but not limited to, complete in all respect, (A) Agitator \nType of Agitator : Pitched Blade Axial Flow Impeller\nImpeller Dia : 570 mm\nGear Box Type : Worm Gear Reducer\nGear Box Ratio : 15 : 1\nAgitator RPM : 200 RPM (Approx)\n(B) Motor : .5 HP\nType : TEFC, Squirrel Cage\nSpeed : 1500 RPM (Approx)\nInsulation : Class F\nIngress Protection : IP-55\nVoltage/Phase/Frequency : 415V (±10%)/3Ph/50Hz (±5%)\nMounting : Horizontal Foot Mounting\n(C) MATERIAL OF CONSTRUCTION\n1 Drive Shaft : SS 304\n2 Impeller : SS 304\n3 Base Frame for Drive Unit : MSEP\n4 Rigid Coupling : CS\n(D) ANCHOR BOLTS & FASTENERS\n1 Under Water : SS 304\n2 Above Water : GI\n | 1 | Each Job | |
68 | 37 | Supply and fixing testing & commissioning including following but not limited to, complete in all respect complete all as specified.\n (A) Agitator \nType of Agitator : Pitched Blade Axial Flow Impeller\nImpeller Dia : 570 mm\nGear Box Type : Worm Gear Reducer\nGear Box Ratio : 15 : 1\nAgitator RPM : 200 RPM (Approx)\nMotor : .50 HP\nType : TEFC, Squirrel Cage\nSpeed : 1500 RPM (Approx)\nInsulation : Class F\nIngress Protection : IP-55\nVoltage/Phase/Frequency : 415V (±10%)/3Ph/50Hz (±5%)\nMounting : Horizontal Foot Mounting\n(C) MATERIAL OF CONSTRUCTION\n1 Drive Shaft : SS 304\n2 Impeller : SS 304\n3 Base Frame for Drive Unit : MSEP\n4 Rigid Coupling : CS\n(D) ANCHOR BOLTS & FASTENERS\n1 Under Water : SS 304\n2 Above Water : GI\n | 1 | Each Job | |
69 | 38 | Supply & filling lime/alum/polyelectrolyte dosing system consisting of ABS dosing pump (0-10 lph) with 100 lit HDPE tank including all piping from the dozer to the reaction tank etc. complete in all respects\n (alum/lime/polyelectrolyte) in flash mixer & Floculator complete all as specified.\n | 3 | Each | |
70 | 39 | Supply and fixing testing & commissioning including following but not limited to, complete in all respect, Air blower including Acoustic Hood Cover & Eletric Motor of capacity 220 Cu.m/hour at 0.45 meter head, 415 V, 3 Phase 50 Hz complete all as specified inclusive of NRV, Air Filter, Cleaner etc complete in all respect.d hole with nuts, bolts, washers and rubber gaskets etc complete all as specified. | 2 | Each | |
71 | 40 | Supply and fixing of tublar air diffusers of 1000mm length and ø90mm for fine bubble of aeration with retrachable arrangement inclusive of proper hanger and ropes need to be provided for pulling of diffusers in future for maintancence. For Sludge Holding Tank, MBBR 1 & 2 complete all as specified. | 18 | Each | |
72 | 41 | Supply and fixing of Slicon Disc air Diffuser size ø150 mm ø for Course bubble of aeration with retrachable arrangement inclusive of proper hanger and ropes need to be provided for pulling of diffusers in future for maintancence. For Equalization Tank complete all as specified. | 12 | Each | |
73 | 42 | Supply and fixing testing & commissioning including following but not limited to, complete in all respect, Tube Settler Tube TS 120 based Hexagonal Chevron Shape,Vertical Height. complete all as Tube Settler modules made of PVC complete all as specified.(For Settling Tank) | 17 | Cum | |
74 | 43 | Supply and fixing of MBBR media made of poly propylene with virgin plastic UV stabilized milky white specific gravity 0.95 to 0.98 complete all as specified. | 18 | Cum | |
75 | 44 | Supply & Providing Chamical & Culture for Start of ETP including Supervisory Staff complete in all respect all as specified. | 1 | Each Job | |
76 | 45 | Supply factory fabricated multi media filter (MMF), cylinderical shape mild steel construction, epoxy coated of capacity 12 Cu.m/hour at 15 metre head with supporting layers of pebbles and graded quartz gravels as filter media with & including suitable staging as per manufacturers instructions complete. Nominal Flow Rate of 15 cum/sqm. cross section complete all as specified.. | 1 | Each | |
77 | 46 | Supply, fixing and commissioning factory fabricated activated carbon filter (ACF), cylinderical shape mild steel construction, epoxy coated of capacity 12 Cu.m/hour at 15 metre head with activate carbon of 800 Iodine Valve with maximum contact time of 26 minutes, layers as filter media with & including suitable staging as per manufacturers instructionscomplete all as specified. | 1 | Each | |
78 | 47 | Supply and fixing testing & commissioning including following but not limited to, complete in all respect,,Ozone Generator 40-50gm/hr, Oxygen Concentrator 5lpm inclued Venturi Injector 1”, Teflon Tube 6mm, Polyurethane Tube 10mm, SS Static Mixer 1 complete all as specified.\n | 1 | Each | |
79 | 48 | Design, Supply and fixing LT panel cubical type of suitable size SCADA based, 415 volts, factory made dust proof vermin proof (Kiosk type) for outdoor use with following specifications:- (For ETP Control Room)\n(A) MAIN PANEL\nMade of 16 SWG CRCA sheet, coated with one coat of primer and two coat of enamel painted/Power coated with S.S. lock, conatins :\n(B) INCOMING :-\n(i) MCCB,100A, 3POLE, of rupturing capacity 25 KA - 01 No\n(ii) MCCB,100A, 3POLE, of rupturing capacity 25 KA - 01 No\n(iii) MCCB,50A, 3POLE, of rupturing capacity 25 KA - 03 Nos\n(iv) ONLOAD FRONT HANDLE OPRATED CHANGEOVER SWITCH FOUR POLE, 100A, of rupturing capacity 25KA - 04 Nos\n(v) Meeting comprises of Ammeter 0-500A with selector switch, voltmeter 0-500 Volts with selector switch with multifunction meter (mfm), indication Lamps for R/Y/B-(For Mains power)\n(C) OUTGOING: Outgoing with following feeders :-\n(i) 150A, ALUMINIUM, BUSBAR (25 X 10-250Sqmm MM) - 02 Set\n(ii) MCB, 25A, 3P, c-curve - 07 Nos\n(iii) MCB, 25A, 3P, c-curve - 04 Nos\n(iv) MCB, 16A, 3P/2P, c-curve - 03 Nos\n(v) MCB, 10A, 2P, c-curve - 08 Nos\n(vi) MCB, 6A, 2P, c-curve - 03 Nos\n(vii) Power factor Panel 97.5 KVAR with three phase capacitor and with (APFC) RELAY - 01 Set\n(viii) Design, Supply and fixing PLC Control System complete all as specified and directed by Engineer-in-charge including all wiring, identifications & civil works - 01 No\n\n | 1 | Each Job | |
80 | 49 | Design , Supply,Installation,commissiong and testing but not limited to Non Contect Type, Transit Type Sensor,Flow (Bi-direction) & Accuracy upm to 01 % to Disply flow rate at point of use and transmit data to PLC complete in all respect and all as directed by Engineer-in-charge size 50 mm to 100 mm dia | 5 | Each | |
81 | 50 | M&L 15 mm thick cement plaster in cement and sand mortar (1:4) in two layer i:e first layer shall be 10 mm thick & other layer shall be 5 mm thick with water proofing compound @ 3 % by weight of cement shall be provided to external surfaces of all buildings unless other-wise all as directed by Engineer-in-charge. | 162.33 | SQM | |
82 | 51 | S&F 2.00 mm thick FRP coating over FRP effulent tank 50000 litres capacity as per ISI specifiecation design including all accessories and T&P for tanks capable of handling chemicals like ARDOX 633A-2526-6025, ORION 68, ZL 37-27A-2C-10B, CHROMIC ACID, RDP etc. The tank shall be equipped with openable type cover of suitable size for maintenance purpose complete all as specified and directed.\nNote:- Measurements of 2mm thick FRP coating shall be net and in sqm area.\n | 535.05 | SQM | |
83 | 52 | Suppy & Filling of chemical and other Accessories reqd for smooth functioning of ETP complete all as directed by Engineer-in-charge | 24 | Per Calender Months | |
84 | 53 | Supply & Fixing of Factory made precast cement concrete man holes Covers including frame as per IS standerd (Heavy Duty) EHD-35 560 MM DIA complete all as specified and directed. | 3 | EACH | |
85 | 54 | Manning Operation & maintanace of the ETP plants of capacity 200KLD for found the clock (in three shift) complete with connected all items of electrical and mechanical eqpt including material and labour for supply and charging of material and chemical as reqd for smooth functioning of ETP plant to achieved desired parameters complete all as specified and directed by Engineer in charge. | 24 | Per Calender Months |