Public Works Department-PWD has published Maintenance Of Electrical Installation And Fans And Rmo Pump Sets Installed At Employment Office , Labour Commissioning Offices , Aero Offices , Pwd Offices Under Ae ( E ) Sub Division -Iii , R . K . Puram Section , Pwd Emd South West , New Delhi . Submission Date for this Tender is 15-03-2021. Electrical Maintenance Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-Mar-2021 | Other | Other | 15-03-2021 |
Name of Work : MOEI & Fans and RMO pump sets installed at Employment office, Labour Commissioning offices, AERO offices, PWD offices under AE(E) Sub Division -III, R.K. Puram Section, PWD EMD South West, New Delhi. (SH:- SITC of LED lights and other miscellaneous elctrical work). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | |||
2 | 1.01 | Group C | 20 | Pts | |
3 | 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. | |||
4 | 2.01 | Group C | 100 | Pts | |
5 | 3 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:- ABB, Schneider, Legrand) | |||
6 | 3.01 | 63 A | 2 | Nos | |
7 | 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. \n | |||
8 | 4.01 | 3 x 1.5 sq. mm | 200 | Mtr | |
9 | 4.02 | 3 x 4 sq. mm | 200 | Mtr | |
10 | 4.03 | 3 x 6 sq. mm | 100 | Mtr | |
11 | 5 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | |||
12 | 5.01 | 25 mm | 80 | Mtr | |
13 | 6 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. | 10 | Nos | |
14 | 7 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. | |||
15 | 7.01 | 5/6 A switch | 20 | Nos | |
16 | 7.02 | 15/16 A switch | 30 | Nos | |
17 | 7.03 | 6 pin 15/16 A socket outlet | 30 | Nos | |
18 | 7.04 | 3 mm thick phinolic laminated sheet | 500 | Sqinch | |
19 | 8 | Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. | |||
20 | 8.01 | 5/6 A switch | 100 | Nos | |
21 | 8.02 | 15/16 A switch | 120 | Nos | |
22 | 8.03 | 6 pin 15/16 A socket outlet | 120 | Nos | |
23 | 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
24 | 9.01 | Single pole | 10 | Nos | |
25 | 10 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
26 | 10.1 | 63 A | 2 | Nos | |
27 | 11 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
28 | 11.01 | 63 A | 2 | Nos | |
29 | 11.02 | 100 A | 1 | Nos | |
30 | 12 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. | |||
31 | 12.01 | 100 A, 16 kA,TPMCCB | 2 | Nos | |
32 | 12.02 | 125 A, 16 kA,TPMCCB | 2 | Nos | |
33 | 12.03 | 150 A, 16 kA,TPMCCB | 1 | Nos | |
34 | 13 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. | 10 | Nos | |
35 | 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 10 | Nos | |
36 | 15 | Supplying Installation, testing and commissioning of 1200 mm sweep ceiling fan with copper binding including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, complete etc. as required. | 5 | Nos | |
37 | 16 | SITC of 1400mm nominal size ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. | 15 | Nos | |
38 | 17 | SITC of 15-18 watt surface mounted Square Downlighter LED fittings size 1 ft x 1 ft. having minimum system efficacy of 100 lumens/watt and colour temperture of 5500-6500 kelvin and CRI of >80 and having power factor of >0.95, THD <10% i/c fixing on the surface with the help of suitble size of screw and fastners i/c connections with 3x1.5 Sq mm FRLS PVC Insulated copper conductor cable etc. complete as reqd. | 15 | Nos | |
39 | 18 | Supplying and fixing of 300 mm sweep 900 RPM exhaust fan complete with louvers and shutters in the existing opening i/c making the hole to suit the size of above fan, making good the damages, connection, testing, commissioning etc. as reqd. | 2 | Nos | |
40 | 19 | Supplying ,installation & testing & commissioning of ventilation fan 250 mm with suitable size louver complete with frame in the existing opening, including making the hole to suit the size of above fan and making good the damage, connection, testing, commissioning etc. as required. | 4 | Nos | |
41 | 20 | Supplying, installation, testing &Commissioning of surface/wallmounted 38W to 40W integrated LED 4 feet fitting with epoxy powder coated white/greyextrudedaluminium channel housing for efficient heatissipation. Total system Lumen of 38W to 40W Led should be 3600 or above in cool daylight(5700K to 6500K), powerfactor>0.95, CRI>80, complete with mounting brackets & accessories asrequired with connections. | 40 | Nos | |
42 | 21 | Supplying, installation, testing & Commissioning of surface type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 600X600mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3400 or above in Cool day Light(5600K to 6500K), Power factor>0.95, CRI (Ra) >80, LED Lamp Make- Cree, Nichia,PhilipsLumiled, Osram, Edison, LED Lamp Efficacy>130 Lm/W. Complete with all accessories as required with connections etc. complete as reqd. | 15 | Nos | |
43 | 22 | Supplying, installation, testing & Commissioning of recessed type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 600X600mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3400 or above in Cool day Light(5600K to 6500K), Power factor>0.95, CRI (Ra) >80, LED Lamp Make- Cree, Nichia,PhilipsLumiled, Osram, Edison, LED Lamp Efficacy>130 Lm/W. Complete with all accessories as required for hanging with ceiling and connections etc. complete as reqd. | 80 | Nos | |
44 | 23 | Supplying installation testing and commissioning of IP65 Surface mounted Led bulkhead type fitting 10-12watt in 5000-6000 K CCT including mounting on surface with help of MS clamps etc including connections ,earthing etc as reqd. | 10 | Nos | |
45 | 24 | Supplying, installation, testing & commissioning of flood light fitting LED made of pressure die cast aluminum with high power LED of 50 watt (intergral type) with having following features: Luminous efficcacy >120 lm/watt, CCT = 3000K, CRI>70, Surge protection device = 5KV, Secondary optics with lens, IP 66 housing, electronic driver, on the existing cove / wall in underpass including suitable sized wiremesh cage etc as per as per specification given in terms and conditions etc. complete as required. | 10 | Nos | |
46 | 25 | Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium cable of following size on wall surface as required. | |||
47 | 25.01 | 3 x 10 sqmm | 120 | Mtr | |
48 | 26 | Credit/Buyback for old dismantle material as and where basis etc as reqd. | |||
49 | 26.01 | Old assorted wire copper | 2.5 | Kg | |
50 | 26.02 | Old assorted MCB/DP/TPN | 20 | Nos | |
51 | 26.03 | Old assorted MCCB 100 A/125 A | 4 | Nos | |
52 | 26.04 | Old assorted MCCB 150A | 1 | Nos | |
53 | 26.05 | 5/6 A switch/Socket piano type | 20 | Nos | |
54 | 26.06 | 15/16 A switch/Socket piano type | 60 | Nos | |
55 | 26.07 | 5/6 A Switch modular | 100 | Nos | |
56 | 26.08 | 15/16 A Switch/Socket modular | 240 | Nos | |
57 | 26.09 | 1200 mm Ceiling Fan | 5 | Nos | |
58 | 26.1 | 1400 mm Ceiling Fan | 15 | Nos | |
59 | 26.11 | 300 mm Exhaust Fan | 2 | Nos | |
60 | 26.12 | 250 mm Ventilation Fan | 4 | Nos | |
61 | 26.13 | Old assorted Fluroscent tube fittings | 120 | Nos |