Supply Of Spect Ct Scanner , Spect Ct Equipment ( Rate Offered Shall Include All Items Mentioned In The Specifications Except Those Items For Which Seperate Price Is Requested Below ) , Additional Work Station , Ups , Desktop Pc , Public Address System , Cctv Cameras , Safety And Warning Gadgets , Office Pc With Laser Printer Scanner Copier , Fume Hood 1500X900x1900mm , Radiation Fume Hood 4X4x3 Feet , Isotope Calibrator , L Bench , Ventillation Perfusion Stand ( Aerosol Generator ) , Flood Phantom , Survey Meters , Contamination Monitor , Gun Monitor , Area Monitor , Pocket Dosimeter , Iodine Uptake Probe , Tmt , Lead Bricks , Qc Generator , Syringe Holder , Syringe Dose Carrier , Lead Bin Foot Operated , Decay Drums , Forceps , Laptop , Lead Apron , Laser Printer , Dry Film Printer , Television 21 , Television 52 , Water Purifier With Hot Water Facility , Medical Grade Glass Door Refrigerator With External Temperature Controls 30 Litre , Refrigerator 165 Litres , Patient Examination Couch , Foot Steps , Washing Machine 8 Litres , Iron Box , Ironing Board , Source For Calibration , Projector With Screen , Collapsible Wheel Chair , Vial Decapper , Kidney Tray , Tray Rectangular With Lid , Lead Goggles , Steel Tray With Cover Small , Glucometer , Digital Bp Apparatus , Digital Thermometer , Nebuliser , Emergency Trolley , Waste Bin Foot Operated , Induction Cooker , Tissue Paper Dispenser , Height Measuring Scale , Aluminium Ladder 5 Steps With Support , Covered Shoe Rack 20 Pair Capacity , Radiation Emergency Kit , Iv Infusion Stand , Consumables - Tissue Paper , Absorbant Sheet , Diposable Apron , Edta , Pottasium Permanganate As Per Spec , Demolishing R . C . C . Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge . , Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge . In Cement Mortar , Dismantling Doors , Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats , Architrave , Holdfasts Etc . Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq . Metres And Below , Dismantling Doors , Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats , Architrave , Holdfasts Etc . Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq . Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead . For Thickness Of Tiles 10 Mm To 25 Mm , Dismantling Aluminium / Gypsum Partitions , Doors , Windows , Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified . Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7 . 5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc . Complete:With Chlorpyriphos / Lindane E . C . 20% With 1% Concentration , Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure , Upto 25 Metre Height , Above Ground Level , Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site , Made With 40 Mm Dia M . S . Tube , Placed 1 . 5 Metre Centre To Centre , Horizontal & Vertical Tubes Joint With Cup & Lock System With M . S . Tubes , M . S . Tube Chakkus , M . S . Clamps And Staircase System In The Scaffolding For Working Platform Etc . And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter . The Scaffolding System Shall Be Stiffened With Bracings , Runners , Connecting With The Building Etc , Wherever Required , If Feasible , For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc . , Complete As Per Directions And Approval Of Engineer-In-Charge . Note: - ( 1 ) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose , ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works . , Filling With Contractors Own Earth ( Excluding Rock ) In Trenches , Plinth , Sides Of Foundations Etc . In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Ramming And Watering , Lead Up To 50 M And Lift Up To 1 . 5 M As Per Direction Of Site Engineer-In-Charge , Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12 . 5 Mm Nominal Size ) Up To Floor Five Level Excluding The Cost Of Centering , Shuttering , Finishing For Leveling Coarse Of Floor And Roof Etc . , Reinforced Cement Concrete Work In Arches , Archribs , Domes , Vaults , Shells , Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering , Shuttering , Finishing And Reinforcement With 1:1 . 5:3 ( 1 Cement : 1 . 5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work , Using Cement Content As Per Approved Design Mix , Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering , Shuttering , Finishing And Reinforcement , Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate , Retard Setting Of Concrete , Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge . Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum . Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately . All Work Above Plinth Level Upto Floor V Level , Steel Reinforcement For R . C . C Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1 . 5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1 . 5 M , Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , Brick Work With Common Burnt Clay Selected F . P . S ( Non Modular ) Bricks Of Class Designation 7 . 5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Above Plinth Level And Upto Floor V Level , Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete . , Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) , 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand ) , Providing And Fixing I St Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make , In All Colours , Shades Except Burgundy , Bottle