Provision Of Water Drainage Approx 600 Mtr Near T-51 At Chabua , Soakage Pit With Sewage Line For Bldg No T-12 And T-13 At Mohanbari And Spl Repairs Of Bldg No T-02A ( Unit Kote ) At Panitola Under Ge Dinjan, DINJAN MIL STN-Assam

Military Engineer Services-MES has published Provision Of Water Drainage Approx 600 Mtr Near T-51 At Chabua , Soakage Pit With Sewage Line For Bldg No T-12 And T-13 At Mohanbari And Spl Repairs Of Bldg No T-02A ( Unit Kote ) At Panitola Under Ge Dinjan. Submission Date for this Tender is 20-03-2021. Drainage Tenders in DINJAN MIL STN Assam. Bidders can get complete Tender details and download the document.




Tender Notice

27155834
Corrigendum : Provision Of Water Drainage Approx 600 Mtr Near T-51 At Chabua , Soakage Pit With Sewage Line For Bldg No T-12 And T-13 At Mohanbari And Spl Repairs Of Bldg No T-02A ( Unit Kote ) At Panitola Under Ge Dinjan
Open Tender
Indian
Assam
DINJAN MIL STN
20-03-2021

Tender Details

ProvISIOn Of Water Drainage Approx 600 Mtr Near T-51 At Chabua , Soakage Pit With Sewage Line For Bldg No T-12 And T-13 At Mohanbari And Spl Repairs Of Bldg No T-02A ( Unit Kote ) At Panitola Under Ge Dinjan

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 71600.0 /-
Tender Value
INR 35.80 Lakhs /-

BOQ Items

Name of Work: PROVN OF WATER DRAINAGE APPROX 600 MTR NEAR T-51 AT CHABUA, SOAKAGE PIT WITH SEWAGE LINE FOR BLDG NO T-12 AND T-13 AT MOHANBARI AND SPL REPAIRS OF BLDG NO T-02A (UNIT KOTE) AT PANITOLA UNDER GE DINJAN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed. 30 Sqm
2 2 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc area not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. 555 Cum
3 3 Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. 58 Cum
4 4 Removing surplus excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. 502 Cum
5 5 Dismantling of asbestos cement (corrugated or semi corrugated ) sheets in roof covering complete all as specified and as directed. 220 Sqm
6 6 Dismantling timber scantlings 40 Sqcm and over in section and in any position in unframed work complete all as specified and as directed. 2.2 Cum
7 7 Dismantling of timber fillets, rails, posts, rafters, purlins etc. under 40 sqcm in section complete all as specified and as directed. 50 RM
8 8 Dismantling structural steel work including doors, window, gates but excluding framed truss etc. complete all as specified and as directed. 1.5 Qtl
9 9 Dismantling wall and celling board (fibre, pulp, insulation etc.) any thickness including cover fillets complete all as specified and as directed. 110 Sqm
10 10 Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed. 150 Sqm
11 11 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed. 2 Cum
12 12 Demolition of cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed. 5 Cum
13 13 Dismantling floor, hearth or wall tiling including cement mortar bedding (dut not backing), removing rubish of the premises complete all as specified and as directed. 170 Sqm
14 14 Dismantling timber boarding, any description, fixed in any position with nails complete all as specified and as directed. 15 Sqm
15 15 S&F for pre-pinted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 200 Sqm
16 16 S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. 20 Sqm
17 17 M&L for rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and as directed. 150 Kg
18 18 M&L for second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails, cross sectional area exceeding 3 and not exceeding 6 Sqcm complete all as specified and as directed. 40 RM
19 19 M&L for second class hard wood plain fillets, bull nosed, splayed, chamfered or rounded on one edge wrought, fixed with screws, cross sectional area exceeding 3 and not exceeding 6 Sqcm complete all as specified and as directed.\n 20 RM
20 20 M&L for preparing new wood or wood based surfaces of any descriptions exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 25 Sqm
21 21 M&L for preparing new wood or wood based surfaces of any descriptions but not exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 6 10 RM
22 22 M&L for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 60 Sqm
23 23 M&L for preparing surfaces of wood and wood based materials, new of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and as directed. 50 Sqm
24 24 M&L for second class hardwood, scantlings, wrought, timber fixed complete all as specified and as directed. 2.2 Cum
25 25 M&L for second class hard wood plain solid, straight chowkats and frames wrought, frame rebated on solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. 1 Cum
26 26 M&L for galvanised iron wire netting of 0.90mm dia and 12mm mesh lathing to wood or metal studding, joints, etc. in walls, ceilings etc., including all laps, cutting and waste fixed with tinned tacks of wire staples complete all as specified and as directed. 150 Sqm
27 27 M&L for rendering 18mm thick in two layers (12+6mm) on one side of lathing in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. 150 Sqm
28 28 M&L for rendering 12mm thick on other side of lathing in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. 150 Sqm
29 29 M&L for rendering 10 mm thick on fair face of brick work or concrete surface in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. 100 Sqm
30 30 M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar (1:4) and finished even and smoother without using extra cement complete all as specified and as directed. 730 Sqm
31 31 M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar (1:4) admixed with WPC as per manufactureres instruction, finished fair and even complete all as specified and as directed. 200 Sqm
32 32 Supply only integral water proofing compound complete all as specified and as directed. 5 Kg
33 33 M&L for preparation of new plastered surfaces of walls by washing, rubbing down, stopping nail holes, fillings cracks with putty etc and applying two coat of distemper oil emulsion complete all as specified and as directed. 250 Sqm
34 34 M&L for preparation of old distempered surfaces of walls by washing, rubbing down, stopping nail holes, fillings cracks with putty etc and applying two coat of distemper oil emulsion complete all as specified and as directed. 100 Sqm
35 35 M&L for two coat of cement base paint after preparation of new plastered surfaces over a coat of alkali resistant cement primar of walls complete all as specified and as directed. 150 Sqm
36 36 M&L for preparation of old decorated surfaces of walls by washing with water rubbing down etc and applying two coat of cement base paint complete all as specified and as directed. 100 Sqm
37 37 M&L preparing newly plastered surfaces of walls and applying two coats of colour wash over a coat white wash complete all as specified and as directed. 30 Sqm
38 38 M&L for three coat of white wash on newly pastered surface/ceiling boardincluding preparation of surface complete all as specified and as directed. 220 Sqm
39 39 S&F for GI frame work seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 to 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange 0f 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. 110 Sqm
40 40 S&F for hangers 6mm dia GI (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3mm size 60mm long complete all as specified and as directed. 110 Sqm
41 41 M&L for seamless calcium silicate ceiling board 12mm thick made out of 1800 X 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screws having phillips head with under head cutter at 200mm centre to centre, including finishing the joints of face board with specifically formulated jointing compound and 48mm wide fibre tape to provide seam less finish fibre tape to provide eseam less finish (frame work for ceiling shall be measured and paid separately) complete all as specified and as directed. 110 Sqm
42 42 M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed or bedding in cement mortor (1:6) and cutting, polishing complete all as specified and as directed. 2 Sqm
43 43 M&L for non skid coloured tiles 7 to 8mm thick (square/ rectangle) area of each tiles exceeding 0.11Sqm but not exceeding 0.18Sqm in floor etc. inciuding 15 mm thick cement mortar (1:6) screed bed or bedding layer set and joined in neat cement slurry and pointed in white or .coloured cement to match complete all as specified and as directed. 160 Sqm
44 44 M&L for glazed colour tile 300mmx200mmx6-7mm set and jointed in neat cement slurry and pointed in coloured cement to match over 10mm thick backing coat in cement mortar (1:4) complete all as specified and as directed. 10 Sqm
45 45 M&L for chequered cement concrete tiles 20cmx20cmx 25mm thick set and jointed and pointed with grey cement and pig ments in neat cement slurry in floors including 15mm thick secreed bed or bedding in cement mortar (1:6) set and jointed and pointed in neat cement slurry complete all as specified and as directed.\n\n\n 30 Sqm
46 46 M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. 4 RM
47 47 M&L for brick work withsub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in built in cement mortar (1:6) complete all as specified and as directed. 44 Cum
48 48 M&L for brick work withsub class 'B' bricks, straight or curved on plan to any radius in half brick walls built in cement mortar (1:4) complete all as specified and as directed. 35 Sqm
49 49 M&L for brick work with sub class 'B' bricks, laid on flat, in drains, etc bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and as directed. 950 Sqm
50 50 M&L for brick work with sub class 'B' bricks, laid on edge, in floors, drains, etc bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and as directed. 350 Sqm
51 51 Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed. (Inner girth only be measured). 620 RM
52 52 Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto complete all as specified and as directed. 550 RM
53 53 S&F for 20mm thick, second class hard wood boarding, planed one sides with butt joints and fixed complete in position as in eaves board etc. complete all as specified and as directed. 15 Sqm
54 54 Taking down chowkhats or frames with shutter (without taking off shutter from frame) exceeding 1.50Sqm but not exceeding 4.0Sqm in each complete all as specified and as directed. 9 Each
55 55 Taking down chowkhats or frames with shutter (without taking off shutter from frame) not exceeding 1.50Sqm in each complete all as specified and as directed. 14 Each
56 56 M&L for 35mm thick second class hard wood plain, framed, panelled shutters (any number of panels), with panels of timberflat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed. 18 Sqm
57 57 S&F for second class hard wood glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares with plain, chamfered or rounded mitred and rebated sash bars any number & fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) complete all as specified and as directed. 4 Sqm
58 58 M&L for 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded as specified in SSR Part-I Section 8 clause 8.24 (b) complete all as specified and as directed. 18 Sqm
59 59 S&F for 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5Sqm. each pane complete all as specified and as directed.. 10 Sqm
60 60 S&F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed. 20 Sqm
61 61 S&F for 75 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed. 56 Each
62 62 S&F for 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed. 27 Each
63 63 S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section etc complete all as specified and as directed. 18 Each
64 64 S&F for 150mm size, aluminium anodised handle, fabricated type complete all as specified and as directed. 18 Each
65 65 S&F for 100 mm long Aluminium, anodised, barrel tower bolts of extruded section etc complete all as specified and as directed. 56 Each
66 66 S&F for 100mm size, aluminium anodised handle, fabricated type complete all as specified and as directed. 56 Each
67 67 S&F for aluminium alloy anodised sliding door bolt with hasp & staple ( bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 250 mm complete all as specified and as directed. 9 Each
68 68 M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and as directed. 60 Sqm
69 69 M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc. complete all as specified and as directed. 51 Cum
70 70 M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. 25 Cum
71 71 M&L for use and waste the form work to sides of concrete foundation, footings plinth beam etc, vertical or to batter complete all as specified and as directed. 5 Sqm
72 72 M&L for use and waste the form work to sides and soffits of floor or roof beams, beam, lintels, cantilevers etc, fair finished surface complete all as specified and as directed. 10 Sqm
73 73 M&L for use and waste the form work to sides of pillars, posts, struts, piers, columns, fair finished surface complete all as specified and as directed. 10 Sqm
74 74 M&L for use and waste the form work to soffits of suspended slab such as roof slab, landings and similar work (Horizontal or sloping) for fair finished surface not exceeding 200 mm thick complete all as specified and as directed. 10 Sqm
75 75 M&L for RCC (1:2:4) type B1 nominal mix (using 20mm graded aggregate) as in foundation footings, foundation beam,plinth beams and bases of columns basement slabs, and mass concrete complete all as specified and as directed. 3 Cum
76 76 M&L for RCC (1:2:4) type B1, nominal mix (using 20mm graded aggregate) as in beams, cantilevers, bressummers, lintels etc. complete all as specified and as directed. 2.5 Cum
77 77 M&L RCC (1:2:4) type B1 (20 mm graded aggregate) as in slabs supported on walls beam and colums in floors, roofs, landind, deck slabs and shelves and the like complete all as specified and as directed. 2 Cum
78 78 M&L for RCC (1:2:4) type B1 nominal mix (using 20mm graded aggregate) as in columns pillers, piers, posts and struts complete all as specified and as directed. 3 Cum
79 79 M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregates) as in surface channel, drains etc. complete all as specified and as directed. 3 Cum
80 80 M&L for PCC (1:2:4) type B-1 (using 20mm graded aggregate) as in linted upto 1.5m clear span, cills steps sesmic and similar bands plinth course, string (cours lacing courses, parapets coping kneelers, apox stone and the like including weather etc complete all as specified and as directed. 6 Cum
81 81 M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed. 0.2 Cum
82 82 M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in cover slab of manholes, septic tank and the like, set in cement mortar (1:4) complete all as directed. \n 7 Cum
83 83 M&L for 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in sub base complete all as specified and as directed. 30 Sqm
84 84 S&F TMT steel bars 10 mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed. 450 Kg
85 85 S&F TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in, stirrups, nibs, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 250 Kg
86 86 M&L for small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and like, including all necessary labours; articles not exceeding 200 cucm each complete all as specified and as directed. 20 Each
87 87 S&F for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way traps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. 8 Kg
88 88 S&F in repairs vitreous china wash basin, size 630x450 mm, white, flat back, with waste, coupling, chain and plug and porcelean stopper and backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. 1 Each
89 89 S&F in repairs 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete complete all as specified and as directed. 1 Each
90 90 S&F in repairs vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe)including connection to trap, and to flushing pipe, anti-syphonage pipe etccomplete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar all as specified, and making good to floor complete all as specified and as directed. 1 Each
91 91 S&F in repairs for vitreous china urinals, bowl type white (excluding flushing cistern but including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed. 1 Each
92 92 S&F in repairs 15 mm bib taps, cast copper alloy fancy type chromium plated with capstan head screwed down screwed for iron pipe of 15mm boreand fixed complete all as specified and as directed. 2 Each
93 93 S&F for 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot or Cold" with long screwed shanks and fly nuts, screwed for iron pipe etc complete all as specified and as directed. 1 Each
94 94 S&F in repairs 15 mm bore, stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 4 Each
95 95 S&F in repairs, 15mm bore, PVC connecting pipe 450mm long with PTMT nuts at both ends complete all as specified and as directed. 4 Each
96 96 S&F in repairs, towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed. 1 Each
97 97 Taking up or down 15 mm bore steel tubing and connections, including removal to store complete all as specified and as directed. 100 RM
98 98 S&F for steel tubes, galvanised 15 mm bore, medium grade with all fittings and fixed complete to wall and ceiling or laid in floors etc complete as specified and directed including taking down old one complete all as specified and as directed. 100 RM
99 99 Taking up or down 20 mm bore steel tubing and connections, including removal to store complete all as specified and as directed. 20 RM
100 100 S&F for steel tubes, galvanised 20 mm bore, medium grade with all fittings and fixed to wall and ceiling or laid in floors etc complete all as specified and as directed. 20 RM
101 101 Taking up or down 25 mm bore steel tubing and connections, including removal to store complete all as specified and as directed. 80 RM
102 102 M&L for steel water tubing of size 25mm bore galvanised, medium grade with all fittings, laid in trenches or under road etc complete all as specified and as directed. 80 RM
103 103 Dismantling water tanks and removing to store exceeding 500 and not exceeding 1000 litre capacity complete all as specified and as directed. 1 Each
104 104 S&F for 500 litrs rotational moulded polythelene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. 1 Each
105 105 S&F for 20 mm bore, gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. 1 Each
106 106 S&F for 25 mm bore, gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.\n\n 1 Each
107 107 S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screw and cup washer complete all as specified and as directed. 2 Each
108 108 S&F for 150mm dia PVC (SWR) pipes single socketed, in any lenth laid in trenches or in floors including necessary fittings complete all as specified and as directed. 500 RM
109 109 S&F for 110mm dia PVC (SWR) pipes single socketed, in any lenth laid in trenches or in floors with rubber ring joints complete all as specified and as directed. 7 RM
110 110 M&L for concrete bed (1:3:6) type C-2 (using 40mm graded stone aggregate) to 150mm drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 333 RM
111 111 M&L for cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in cement mortar (1:3) to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete (1:2:4) type B-1 finished smooth and reforming benching as required for 150/160mm bore pipe complete all as specified and as directed. 15 Each Pipe
112 112 M&L for cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in cement mortar (1:3) to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete (1:2:4) type B-1 finished smooth and reforming benching as required for 200/225mm bore pipe complete all as specified and as directed. 5 Each Pipe
113 113 M&L for loose filling with broken bricks bats of guage 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed. 15 Cum
114 114 S&F for PVC (SWR) vent cowl 110 mm complete all as specified and as directed. 2 Each
115 115 M&L for sand filling under floors or in foundation including watering and consolidating complete all as specified and as directed. 1 Cum
116 116 Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, including unserviceable fitting such as switches, ceiling roses, pendants, regulators, sockets, etc and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. 31 Point
117 117 M&L for Point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box (sunken type) 3mm thick hylam sheet cover fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. 25 Point
118 118 All as per item No. 117 here-in-above but one 5A, 3 Pin switch socket combination on independent board complete all as specified and as directed. 3 Point
119 119 All as per item No. 117 here-in-above but one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and as directed.\n 3 Point
120 120 S&F for switch piano, flush type, 5/6 Amps, single pole, one way, 240 Volts complete all as specified and as directed. 28 Each
121 121 S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. \n 3 Each
122 122 S&F for switch socket combination 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and as directed. 3 Each
123 123 S&F in repair Stepped type electronic fan regulator flush type 230 volt 5 speed control and connecting up and fix position , complete all as specified and as directed.\nMake : ANCHOR/Legrand/Havells. 3 Each
124 124 S&F for ceiling rose, surface bakelite, 65x50 mm, two to three terminals complete all as specified and as directed. 22 Each
125 125 S&F for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. 3 Each
126 126 S&F for LED Lamp 7 watt complete all as specified and as directed. 3 Each
127 127 S&F for double door MCB distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 1 Each
128 128 S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed.\nMake : Cat No. TSPC6-32 of HPL/Havells/Legrand. 6 Each
129 129 S&F for MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. \nMake : Cat No TFPNC6-32 of HPL/Havells/Legrand. 1 Each
130 130 S&F for 18 W surface and wall mounted LED batten with polycarbonate housing and integrated driver complete all as specified and as directed.\nMake : Cat No. LUMILINEBS18WLED865SPCWH of Havells/Philips/Bajaj. 12 Each
131 131 S&F in repairs 10W,LED, energy saving new generation bulk head luminaire with opal diffuser including lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. \nMake : Cat part no- RUGBYNEONFT10WLED860SSYMTOPC of Havells/Philips/Bajaj. 3 Each
132 132 M&L for spray painting to ceiling fans by one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc upto 1400 mm sweep by dismantling fan blades including writing MES No and alphabets complete all as specified and as directed.\n\n 3 Each
133 133 S&F in repairs 25 W LED building security new generation energy saving and environmental friendly long life LED light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having TOP OPENING seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 with suitable light grade GI bracket complete all as specified and as directed.\nMake : CAT No ENDURAPEARLSL25WSASYTOPC of Havells/Philips/Bajaj. 4 Each
134 134 M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing alongwith submission of test results complete inclduing taking down old earthing as specified and as directed.\n 1 Each
135 135 M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing alongwith submission of test results complete inclduing taking down old earthing complete as specified and as directed. 4 Each
136 136 M&L in replacement of aluminium strip 25 x3mm buried in ground/ passing through protection pipe etcc complete all as specified and as directed.\n\n 80 RM
137 137 S&F for air termination single pointed aluminium rod 12 mm dia 300 mm long in built with GI pipe of midium grade of 25mm dia (1.5 Mtr long) suitable nut, bolts, screws, washers complete as specified and as directed. 6 Each
138 138 S&F for test point terminal block made of gun metal or phosphorus bronze including taking down old one complete all as specified and as directed. 4 Each
139 139 Supply and laying well burnt bricks sub class B bricks laid breath wise along length of cable in trenches for cable protection complete all as specified and as directed. 480 Each
140 140 Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as specified and as directed. 4 Cum
141 141 Supply, laying and testing XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve including taking out existing unserviceable cable of size 25Sqmm 2 core complete all as specified and as directed. \nNote: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.\nMake:- Havells/Polycab/CCI/NICCO/Gloster\n\n 60 RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail