Construction Of Boys Hostel In The Campus Of Ch . Ranbir Singh State Institute Of Engineering And Technology At Village Silani Kesho In Jhajjar District ( Pdg Lan Wifi And Epabx System Only ) , Jhajjar-Haryana

Public Works Department-PWD has published Construction Of Boys Hostel In The Campus Of Ch . Ranbir Singh State Institute Of Engineering And Technology At Village Silani Kesho In Jhajjar District ( Pdg Lan Wifi And Epabx System Only ) . Submission Date for this Tender is 03-03-2021. EPBAX Tenders in Jhajjar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

27114439
Construction Of Boys Hostel In The Campus Of Ch . Ranbir Singh State Institute Of Engineering And Technology At Village Silani Kesho In Jhajjar District ( Pdg Lan Wifi And Epabx System Only )
Open Tender
Indian
Haryana
Jhajjar
03-03-2021

Tender Details

Construction Of Boys Hostel In The Campus Of Ch . Ranbir Singh State Institute Of Engineering And Technology At Village Silani Kesho In Jhajjar District ( Pdg Lan Wifi And Epabx System Only )

Key Value

Document Fees
INR 500 /-
EMD
INR 9960.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of Boys Hostel in the campus of Ch. Ranbir Singh State Institute of Engineering & Technology at village Silani Kesho in Jhajjar District (Pdg LAN WIFI and EPABX System only)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, Installation, Testing & Commissioning of 6 Core, Multi Mode Fibre Armoured, OM3 as complete as required. Make: Molex/ R&M , AMP / Simon BI01010001010000000000000515BI0100001120 650 P.Mtr.
2 2 Supply, Installation, Testing & Commissioning of 6 port multimode loaded LIU with pigtails splite tray, couplers as complete as required. Make: Molex/R&M/Simon BI01010001010000000000000515BI0100001226 2 Each
3 3 Supply and Install IP User Licences Minimum 10 Users Matrix complete in all respect. (Existing exchange is being used) Make: EPABX GE BI01010001010000000000000515BI0100001123 1 Each
4 4 Supply, Installation, Testing & Commissioning of LC - LC MM 0M3 DUPLEX Length- 3m patch cord complete in all respect. Make:R&M/Simon/Molex BI01010001010000000000000515BI0100001124 2 Each
5 5 Supply and Installation of Matrix IP Phone SPARSH VP310E complete in all respect. (Existing exchange is being used) Make Matrix BI01010001010000000000000515BI0100001165 4 Each
6 6 Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work.(Based on H.S.R) \nMake: AKG/Diplast/Ravindra BI01010001010000000000000515BI0100001217
7 6.01 (i) 25 mm dia. BI01010001010000000000000515BI0100001170 100 P.Mtr.
8 7 Supply and erection of UTP CAT6 cable in prelaid PVC conduits / pipes / raceway, but without the cost of raceway or pipe. (The cable is to be drawn from individual workstation/device/desktop area to the networking distribution rack/main rack at central communications/server room (for Data) or to IDF/MDF (for telephones connectivity) complete in all respect. Make: AMP/D-link/Molex BI01010001010000000000000515BI0100001214 300 R/Mtr.
9 8 SITC of CAT6 UTP RJ-45/RJ-45 Patch Cords Solid Conductor 1 Mtr. length complete in all respect. Make Dlink/AMP/Molex BI01010001010000000000000515BI0100001215 15 Each
10 9 SITC of CAT6 UTP RJ-45/RJ-45 Patch Cords Solid Conductor 3Mtr length complete in all respect. Make Dlink/AMP/Molex BI01010001010000000000000515BI0100001216 15 Each
11 10 Supply and Installation of Single UTP CAT6 RJ-45 I/O of specified make including single/dual faceplate and MS backbox assembly, inclusive of termination of CAT6 cable at each IO at workstation area / device / desktop / or at a patch panel inside a rack complete in all respect. Make: Dlink/AMP/Molex BI01010001010000000000000515BI0100001166 15 Each
12 11 Supply and Installation of UTP CAT6 Gigabit Patch Panel for 24 ports in 1U form factor as per the tender specifications, with universal A/B labeling and 110 connector terminations on rear of panel allowing for quick and easy installation of 22 to 24 AWG cable complete in all respect. Make: Dlink/AMP/Molex BI01010001010000000000000515BI0100001167 1 Each
13 12 SITC of 600 mm x 600 mm 6U Free standing cabinet with front locable door, side panels, 2 set of caster wheel, 230V AC 90CFM fan 4, three hardware Packet 1 set (containing 20 No. each of 3), AC power strip combination of 5 A-15 A 12 socket, heavy duty stationary shelf 600w x 600mmD , 2 cable channel 100 mm wide 6 U . one earthing strip 150 mm H, 4 cable manager 1U height complete in all respect. Make: Ritall/Comrack/Dlink BI01010001010000000000000515BI0100001218 1 Each
14 13 24 Port POE Layer 2 Switch Port Standards: IEEE 802.3 10BASE-T Ethernet (twisted pair copper), IEEE 802.3U 100BASE-TX Fast Ethernet (tewisted pair copper), IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper), IEEE 802.3z Gigabit Ethernet (fibre) ANSI/IEEE 802.3, Auto negotiation. IEEE 802.3x Flow Control, Interface:24 10/100/1000 Mbps BASE-TxPoE 4 10/100/1000 BASE T/SFP, PoE Standard. 802.3 al& 802.3 at PoE Power 370watts or Better should have minimum 56 Gbps switching capacity and 41 Mbps certification:- UL ,CE/IC,FCC,ROHS II protocol:- SNMP v1/v2/v3 IGMP v1/MLD V2, DHCP Safety client/Relay Layer 2 and Layer3 ACL Surge protection complete in all respect.\nMake: Juniper / Cisco/Extreme).\n BI01010001010000000000000515BI0100001132 1 Each
15 14 Supply Installation Testing Commissioning of Wireless AP witrh 802.11 a/b/g/n/ac. AP with integrated antennae AP should be dual- radio (l wifi radio plus) Must support 11n 2*2:2+ 11ac 4*4:4 multiple input multiple- output (MIMO) with spatial streams 1x gigabit Ethernet interfaces along with console port ,2.4 GHZ with minimum 400 mbps data rate and 5.1 Ghz with minimum 1730 mbps data rate should support 20,40 and 80 MHZ channels UL 2043 certified, The AP should be capable of working as a virtual controller for the locations where the number of AP is less than 64 and should be supplied with POE injector. Access Points must support minimum operating temprature range from -0 degree to + 45 degree complete in all respect. Make: Cisco AIR AP28021-D-K9/Matrix/Alcatel AP 1221/Extreme BI01010001010000000000000515BI0100001171 4 Each
16 15 Supply and errection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (Based on HSR) (ISI mark) BI01010001010000000000000515BI0100001220
17 15.01 (i) HDPE pipe 63/50 mm outer dia/ inner dia BI01010001010000000000000515BI0100001221 600 P.Mtr.