Military Engineer Services-MES has published Repair / Replacement Maintenance Of Ug Cable Oh Lines Lt Panel Board Transformer Vcbs Panel And Allied Work At Cooch Behar And Ap Telepara Under Ge ( S ) Binnaguri. Submission Date for this Tender is 08-03-2021. Circuit Breakers Tenders in BINNAGURI MIL STN West Bengal. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 01-Mar-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-03-2021 |
Name of Work: REPAIR / REPLACEMENT MAINTENANCE OF UG CABLE, O/H LINES, LT PANEL BOARD, TRANSFORMER, VCBS PANEL AND ALLIED WORK AT COOCH BEHAR AND AP TELEPARA UNDER GE (S) BINNAGURI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Schedule 'A' | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | M&L for dehydration and filtration of transformer oil of various transformers at site using ON-LINE Ultra High Vacuum portable dehydrating machine to remove moisture and carbon content untill achieve desired dielectric strength not less than 50 KV dielectric strengthen 4mm gap,(oil samples of each transformer is to be tested before and after test and test results to be recorded in printed format with embossing date of testing on format and on equipment using synthetic enamel paint and to be produced during claiming RAR's) including disconnecting the HT and LT cables, cleaning the Bus bar surfaces, taking out & refilling oil, and reconnecting the cables by providing copper washers,Bolts,Nuts etc. complete all as specified and as directed.\nNote:- Oil required for topping up shall be measured and paid separately.\nThe quoted rate shall deemed to include for proper cleaning of oil tank to make free from sludge etc.\nThe measured quantity shall be net quantity reused for filling after dehydration having dielectric strength not less than 50 KV in 4mm gap in multipass. | BI01010001010000000000000515BI0100001113 | 800 | LITRES |
3 | 2 | Supply & filling new Transformer oil having Di-electric strength 50 KV with oil testing kit in 4 mm gap, Kinematic viscosity @ 40°C between 9.5-14.5, for topping up to Transformers, VLE type OCB"s complete all as specified and as directed complete all as specified and as directed. | BI01010001010000000000000515BI0100001114 | 200 | LITRES |
4 | 3 | S & F in replacement of Temperature gauge as per existing type/capacity & make including provision of necessary socket cover, pipe etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001115 | 2 | EACH |
5 | 4 | Checking, identifying the defect /faulty point of HT cable using Cable fault locator machine(computerized/primary current injection method) and taking out faulty cables and bricks from the trench upto fault point along cable route and re-laying the same using old bricks & New sand incl returning filling and making good surface as per existing complete all as directed for the following size of cable : 95 sqmm, 3 core Note- (i) Cable fault locator machine with all T&P required for identifying the faulty point will be arrange by contractor and the cost is included in unit rate for finding of fault using cable fault detector machine.\n(ii) Earth work, sand filling, returning filling and removing of soil, cable jointing kit(if required),additional length of cable shall be measured and paid separately. | BI01010001010000000000000515BI0100001116 | 2 | EACH |
6 | 5 | S & F of cable jointing kit for 11 KV grade for indoor use heat shrinkable type (earthed) complete with jointing materials and and accessories suitable for making connection of 95 sqmm 3 core,11000 volt grade cables, meggering & re-storation of electric supply complete all as specified and directed.\n | BI01010001010000000000000515BI0100001117 | 2 | EACH |
7 | 6 | S & F of cable jointing kit for 11 KV grade for outdoor use heat shrinkable type (earthed) complete with jointing materials and and accessories suitable for making connection of 95 sqmm 3 core,11000 volt grade cables, meggering & re-storation of electric supply complete all as specified and directed.\n | BI01010001010000000000000515BI0100001118 | 2 | EACH |
8 | 7 | S & F in replacement of Silica Gel for breather for various capacity of Transformer's in 150 Gms. Pack complete all as specified and directed | BI01010001010000000000000515BI0100001119 | 5 | KG |
9 | 8 | Disconnection, taking down, dismantling complete including necessary testing for insulation for 630 Amps capacity, 11 KV indoor drawout type trolley mounted VCB for necessary repair, replacement work as per the following:-\n(a) Transportation of VCB from Cooch Behar (different Sub Station) to Siligri/Jalpaigri workshop for repair and return after repair.\n(b) Opening up carefully without damaging any part and detecting the fault/defects in manual spring charge ON-OFF mechanisham and testing for proper functioning of breaker for ON-OFF function,sercing of male, female contacts, greasing all the mechanical components and applying dry graphite conductive sealant for contacts,\n(c) Cleaning, Inspecting and testing of HT 11 KV Busbar chamber, checking insulators at input and output for any cracks or damages, checking for cable termination for all three phases, cleaning the copper Busbars,checking the proper insulations and tightening all the Nuts, Bolts and washers of Busbars complete.\n(d) Cleaning, Inspecting and testing of electrical wiring system,Ammeter,Voltmeter,VAF meter, Selector switches, all illuminated indicators for RYB phases,DC supply healthy spring charge, trip circuit healthy etc.\n(e) Cleaning, Inspecting and testing of Over current relay,CT ammeter,PT of Voltmeter for display of voltage 11 KV HT complete .\n(f) Setting of Earth fault relay and Over current relay as per manufacturers instruction complete. Note:- Cost of all the materials,components repairs,elements described above including any missing components to make the VCB in fully functional/ working condition are included in the quoted rate of Item No-09 to 15 here in above except the followings which will measured separately as supply only Rates. | BI01010001010000000000000515BI0100001120 | 2 | EACH JOB |
10 | 9 | Supply only Closing coil for VCB, 11000Volt HT, Type VE-12,30 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001121 | 2 | EACH |
11 | 10 | Supply only Tripping coil for VCB, 11000Volt HT, Type VE-12,30 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001122 | 2 | EACH |
12 | 11 | Supply only Spring charging motor of 230 Volts,0.25 HP,8000 RPM for VCB, 11000Volt HT, Type VE-12,30 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001123 | 2 | EACH |
13 | 12 | Supply only Vaccum interruptor,tube type,VL 35400 od for VCB, 11000Volt HT, Type VE-12,30 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001124 | 2 | EACH |
14 | 13 | Supply only Moving contact top bottom for VCB, 11000Volt HT, Type VE-12,30 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001125 | 2 | EACH |
15 | 14 | Supply only Motor cut off limit switch of VCB charging motor circuit for VCB, 11000Volt HT, Type VE-12,30 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001126 | 2 | EACH |
16 | 15 | Supply only Power pack of standard input supply 110 V and output supply 30 V 200 VA for VCB, 11000Volt HT, Type VE-12,30 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001127 | 2 | EACH |
17 | 16 | S & F in replacement of MCCB, 4 pole 415 Volts, 50 Hz, 400 amps rating, 50 KA breaking capacity, with adjustable thermal and adjustable magnetic setting type including making necessary connection with spreader, link and aluminium lugs complete all as specified and as directed. | BI01010001010000000000000515BI0100001128 | 1 | EACH |
18 | 17 | All as per item No-16.00 here-in-above but 100 Amps rating,25 KA breaking capacity, 4 Pole - ditto - | BI01010001010000000000000515BI0100001129 | 2 | EACH |
19 | 18 | All as per item No-16.00 here-in-above but 160 Amps rating,25 KA breaking capacity, 4 Pole - ditto - | BI01010001010000000000000515BI0100001130 | 2 | EACH |
20 | 19 | All as per item No-16.00 here-in-above but 200 Amps rating,25 KA breaking capacity, 4 Pole - ditto - | BI01010001010000000000000515BI0100001131 | 2 | EACH |
21 | 20 | All as per item No-16.00 here-in-above but 250 Amps rating,25 KA breaking capacity, 4 Pole - ditto - | BI01010001010000000000000515BI0100001132 | 2 | EACH |
22 | 21 | M& L for APFC relay 3 step complete all as specified and directed.\n | BI01010001010000000000000515BI0100001134 | 1 | EACH |
23 | 22 | M&L for Painting of Two pole structure including cross Arms,Channels,Clamps etc.externally above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block and Writing letters 8 cm height, HT and Pole Nos using Black synthetic Enamel paint complete all as specified and directed . | BI01010001010000000000000515BI0100001135 | 3 | EACH |
24 | 23 | All as per Item No-22.00 here-in-above but Four Pole structure -Ditto -. | BI01010001010000000000000515BI0100001136 | 4 | EACH |
25 | 24 | S & Fix in replacement of Danger notice plate of 1.6 mm thick mild steel sheet letters, figures and conventional skull and bones in single red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT pole, of size 25x20cm, complete all as specified and as directed. | BI01010001010000000000000515BI0100001137 | 7 | EACH |
26 | 25 | M & L for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed. | BI01010001010000000000000515BI0100001138 | 0.1 | QTL |
27 | 26 | M & L for spreading crushed/Broken stone ,40mm graded, sand stone aggregated around and under 2 Pole/ 4 Pole structure uniformly levelled in layer n.exc 30cmthick in each layer complete all as specified and as directed.\nNote :- Spread thickness of aggregates shall be measured with deduction of 50% for voids from cubical contents for arriving net quantity. | BI01010001010000000000000515BI0100001139 | 10 | CUM |
28 | 27 | M & L for complete servicing and calibration of HT 11 KV VCB RMU and HT 11 KV RMU relays and tripping mechanism for regulating the fault flow (over current, Earth fault, differential) in sequence from down stream 11 KV distribution VCB's to SF-6 Breaker at switch room of receiving station complete and getting tested and certified by the authorised testing agency/manufacturing agency for accuracy for efficient functioning and servicing and cleaning to VCB trolleys 11 KV,3 pole,630 Amps including repairs to manual charging system of vaccum circuit breaker by servicing the charging mechanism(T1) and Operating mechanism (T2) and electrical connections complete all as specified and as directed. | BI01010001010000000000000515BI0100001140 | 1 | EACH JOB |
29 | 28 | S & F of Switch Air break, Triple pole mechanically gang operated switch mounted on insulators and steel frame, Single break insulator suitable for outdoor vertical mounted,CPRI approved with manual operating mechanism made out of heavy grade G I Pipe,G I arching horns and terminal connectors for ACSR conductors conforming IS-1818/72 and 9921/85 with 3 isolators per pole Capacity 200 Amps for 11 KV Operation and operating mechanism worked from ground level including necessary adjustment and making holes on existing Angle and including drop fuse unit of 100 Amp and testing complete all as specified and as directed. | BI01010001010000000000000515BI0100001141 | 3 | EACH SET OF THREE |
30 | 29 | S & F replacement of Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade HT over head line, complete all as specified and as directed. | BI01010001010000000000000515BI0100001142 | 8 | EACH |
31 | 30 | Dismantling and repairs of defective GOD switch, current rating upto200/400 Amps,11000 Volts grade, including merging of insulators and operating mechanism and replacement of Male and Female contact,handle,arching horn and all rusted GI Nuts, Bolts and washers for proper connection of ACSR conductor/Cables and necessary Greasing etc. to make 100% serviceability and proper functioning of GOD switch including taking down of unserviceable insulators of any type and replace with New Insulators (Insulators shall measured and paid separately) and testing after repair complete all as specified and as directed. | BI01010001010000000000000515BI0100001143 | 2 | EACH JOB |
32 | 31 | Supply only Post type Insulator, Vitreous China,White,Brown for 11000 volt grade, Large size, with overall dimensions 90 x 140mm clearance of hole 25.5mm complete all as specified and as directed. | BI01010001010000000000000515BI0100001144 | 6 | EACH |
33 | 32 | M & L for in replace MS jumper in place of turned and depealed jumper complete all as specified and as directed. | BI01010001010000000000000515BI0100001145 | 4 | EACH |
34 | 33 | M & L for in replace MS hot dipped galvanised Nuts,Bolts,Washers in place of torned and rusted Nuts,Bolts,Washers complete all as specified and as directed. | BI01010001010000000000000515BI0100001146 | 2 | KG |
35 | 34 | Supply, laying, jointing & testing HT cable XLPE Insulated screened, (earthed) PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of cross sectional area 95 Sqmm 3 core complete all as specified and directed. | BI01010001010000000000000515BI0100001147 | 150 | RM |
36 | 35 | Supply, laying & Testing LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using aluminium lugs both end of cable & wrapping PVC tape over XLPE insulation cable complete all as specified and as directed for following size of cables :-\nNOTE 1 : Specification of cable shall be as under:-\n(a) Inner sheathing shall be of extruded PVC.\n(b) Cable shall also be supplied with sequences hall marking at every metre on the luner sheathing.\n(c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification.\n(d) Anti rodent and antitermite compound added.\n(e) PVC compounds of various grades as IS-5831.\n(f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.\nNote 2 :-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately\n\n(a) 10 Sqmm 4 core | BI01010001010000000000000515BI0100001148 | 300 | RM |
37 | 36 | (b) 35 Sqmm 3.5 core | BI01010001010000000000000515BI0100001149 | 200 | RM |
38 | 37 | (c) 50 Sqmm 3.5 core | BI01010001010000000000000515BI0100001150 | 200 | RM |
39 | 38 | (d) 70 Sqmm 3.5 core | BI01010001010000000000000515BI0100001151 | 200 | RM |
40 | 39 | (e) 95 Sqmm 3.5 core | BI01010001010000000000000515BI0100001152 | 200 | RM |
41 | 40 | (f) 120 Sqmm 3.5 core | BI01010001010000000000000515BI0100001153 | 120 | RM |
42 | 41 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying cables/pipe not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified.\nNote:- Excavation shall be made carefully to avoid damage of existing cables and Brick protection. Existing bricks/precast concrete cable cover shall be taken out ,stagged for reuse complete all as specified and as directed. | BI01010001010000000000000515BI0100001154 | 240.53 | CUM |
43 | 42 | Removing surplus soil to a distance not exceeding 50m and depositing where as directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. | BI01010001010000000000000515BI0100001155 | 88.64 | CUM |
44 | 43 | Returning and filling in trenches including spreading, leveling watering and ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed. | BI01010001010000000000000515BI0100001156 | 140.6 | CUM |
45 | 44 | Relaying only bricks/precast concrete cable cover obtained from dismantling here in above laid dry flat for protection of cable complete all as specified and as directed. | BI01010001010000000000000515BI0100001157 | 1500 | EACH |
46 | 45 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr-in-Charge. | BI01010001010000000000000515BI0100001158 | 1400 | EACH |
47 | 46 | Material and labour for sand cushioning for under ground cable 8 cm before laying the cable and 15cm after laying and punned to 18cm including stretching the cable complete all as specified and as directed. | BI01010001010000000000000515BI0100001159 | 75 | CUM |
48 | 47 | Material and labour for Factory made precast concrete cable cover of class HV,Type-I,of size 300mm x 198mm x 40mm, complete all as specified and as directed. | BI01010001010000000000000515BI0100001160 | 700 | EACH |
49 | 48 | M&L (in replacement) for GI tubing 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and as directed for following sizes :-\n\n(a) 50 mm bore | BI01010001010000000000000515BI0100001161 | 50 | RM |
50 | 49 | (b) 40 mm bore | BI01010001010000000000000515BI0100001162 | 30 | RM |
51 | 50 | M & L for in replace Male Contacts/Moving contacts in place of unserviceable Male Contacts/Moving contacts complete all as specified and as directed. | BI01010001010000000000000515BI0100001163 | 3 | EACH |
52 | 51 | M & L for in replace Female Contacts/Moving contacts in place of unserviceable Female Contacts/Moving contacts complete all as specified and as directed. | BI01010001010000000000000515BI0100001164 | 3 | EACH |
53 | 52 | M & L for in replace back connector plate in place of unserviceable back connector plate complete all as specified and as directed. | BI01010001010000000000000515BI0100001165 | 3 | EACH |
54 | 53 | S & F of digital Amp-meter CT operated (excluding CT) of size 144mm x 144mm, suitable for HV panel board 11000 Volt grade ranging 0 to 100/50 Amp complete all as specified and as directed. | BI01010001010000000000000515BI0100001166 | 1 | EACH |
55 | 54 | S & F of digital Amp-meter PT operated (excluding PT) of size 144mm x 144mm, suitable for HV panel board 11000 Volt grade ranging 0 to 15 KV complete all as specified and as directed. | BI01010001010000000000000515BI0100001167 | 2 | EACH |
56 | 55 | S & F in repair of PT rasin cast, three phase,11 KV of ratio 11000/110 Volt, including necessary fuses for metering and protection, connected with HT VCB , meant for incoming VCB, suitable burdon of 15 VA class 0.5, conforming to IS 3156/1992, frequency 50 Hz, voltage factor 1.2 continuous and 1.5 for 30 second, single phase, insulation level 12/28/35/75 KV connection star-star or delta-delta as per site requirement and suitable for ALSTOM or equvailent make VCB complete all as specified and as directed.\nNote :- The quoted rate shall deemed to have been included the cost of insulation oil as required quantity conforming to dielectric strength as per IS : 1866. | BI01010001010000000000000515BI0100001168 | 1 | EACH SET OF THREE |
57 | 56 | M & L for Preparation of surface area of Transformer by removing cleaning of existing painting and removing the dust and dirt, cleaning with sand paper and repainting of transformer 400 KVA indoor/Outdoor type complete with two coats of synthetic enamel paint over a coat of red oxide primer( using spray machine) all as specified and directed (colour of paint to be as per existing colour code norms including necessary Denting/Welding & Writing MES No & SM No with letters 100mm height with white Synthetic enamel paint over black coloured surface). complete all as specified and as directed. | BI01010001010000000000000515BI0100001169 | 1 | EACH |
58 | 57 | Disconnection, taking down, dismantling complete including necessary testing for insulation for up to 200 KVA capacity step down transformer and necessary repair, replacement work as per the following:-\n(a) Transportation of transformer from Telepara/coochbehar (different Sub Station) to Siliguri/Jalpaiguri workshop for repair and return after repair.\n(b) Opening top cover carefully without damaging any part and detecting the fault/defects in complete core by testing of LT/HT side.\n(c) Disconnecting the LT and HT coil and rewinding the same with suitable gauge of super enameled copper conductor as per existing size for the three and four limbs complete..\n(d) Heat varnishing by putting the complete limbs/core assembly into heat chamber.\n(e) Cleaning, decarbonising and dislodging of inner chamber by draining out transformer oil, cleaning all terminal points and leads, explosion vent, silica gel, breather and replacement of unserviceable breather, nut bolt and washers, LV, HV studs, spindles,\nrefilling the container with transformer oil after dehydration/new transformer oil, replacement of cock sheet gasket complete .\n(f) Replacement of LT, HV terminals and studs complete. (g) Preparation of surface area of Transformer by removing cleaning of existing painting and repainting of transformer complete (after reassembling) with two coats of synthetic enamel paint over a coat of red oxide primer( using spray machine) all as specified and directed (colour of paint to be as per existing colour code norms including necessary Denting/Welding & Writing MES No & SM No). \n(h) Reassembling, reinstallation at original location or as directed including restoration of electrical connection, commissioning and testing on load complete all as specified and directed.\nNOTE :-(i) Supply only for super enameled copper conductor(wire/strip), LV terminals/HV terminals, LV studs/HV studs and other spare parts mentioned under Sl item No-62 shall be measured and paid separately under relevant items hereinafter as supply only.\n(ii) OLD serviceable Transformer oil shall be reused after dehydration/Filteration with dielectric strength of 50KV with 4mm gap.\n(iii) Paints, red oxide primer, nuts, bolts, washers etc required for the job shall be deemed to be included in the quoted rate and these items shall not be measured separately.\n(iv) Necessary test of above transformer shall be carried\nout at site as per IS in presence of Engr-in-Charge. | BI01010001010000000000000515BI0100001170 | 2 | EACH |
59 | 58 | All as per Item No-58.00 here-in-above but 250 KVA to 315 KVA - Ditto -. | BI01010001010000000000000515BI0100001171 | 2 | EACH |
60 | 59 | All as per Item No-58.00 here-in-above but 315 KVA to 400 KVA - Ditto -. | BI01010001010000000000000515BI0100001172 | 1 | EACH |
61 | 60 | Supply only High quality Super enameled insulated copper wire conforming to relevant IS for HV winding of transformer upto 400 KVA complete all as specified and as directed.\n\nNote :-The weight of Copper wire before insulation shall be measured for payment purposes and weight shall be taken in presence of Engineer in charge and duly signed by both the parties on the date of measurement. Entries in Mb shall be Taken accordingly based on the joint measurement sheet duly signed by both the parties complete all as specified and as directed. | BI01010001010000000000000515BI0100001173 | 115 | KG |
62 | 61 | Supply only High quality Super enameled insulated copper wire conforming to relevant IS for LV winding of transformer up to 400 KVA complete all as specified and as directed.\n\nNote :-The weight of Copper wire before insulation shall be measured for payment purposes and weight shall be taken in presence of Engineer in charge and duly signed by both the parties on the date of measurement. Entries in Mb shall be Taken accordingly based on the joint measurement sheet duly signed by both the parties complete all as specified and as directed. | BI01010001010000000000000515BI0100001174 | 220 | KG |
63 | 62 | M & L for earthing with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron, GI pipe 40 mm bore light grade for protection of earth strip, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways, 20mm bore watering pipe perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal dust filling, test point made of phosphated bronze with fixing arrangement all as shown in electrical plate No. 3 of MES SSR part-I and making test point including excavation & earth work and connecting the earthing to an earthing point/equipment & testing complete all as specified and as directed.\n(Note - Main earthing lead and its protection pipe upto 7.5 mtr length deemed to be included in the item) | BI01010001010000000000000515BI0100001175 | 6 | EACH JOB |
64 | 63 | Supply only HV Terminals studs with Nuts, Bolts and Washers made out of Copper/Brass suitable for 250 KVA/400 KVA Transformers complete all as specified and as directed. | BI01010001010000000000000515BI0100001176 | 3 | EACH |
65 | 64 | Supply only LV Terminals studs with Nuts, Bolts and Washers made out of Copper/Brass suitable for 100 KVA/250 KVA Transformers complete all as specified and as directed. | BI01010001010000000000000515BI0100001177 | 3 | EACH |
66 | 65 | Supply & fixing in replacement, heavy duty 3 phase,25 KVAr,480 Volt,50Hz tuned capacitor fixed type complete all as specified and as directed.\n | BI01010001010000000000000515BI0100001178 | 3 | EACH |
67 | 66 | Supply, Install, Testing & Commissioning in replacement Self powered, Numerical relay IDMT Type(03 O/C + 01 EF) for 11 KV CSS RMU, rating 5 Amps, with trip setting OC : 20-240 % & EF 10-100% OC HF : 50-3200% in steps of 50% & EF HF : 50-1200%nin steps of 50% in stepped of 50%,OC & EF TMS : x0.01-x1.2, Contacts : 2 C/O Latching Type, Status : 3 Status Input (1 status is assigned to CB NO for cold load function) complete all as directed & as specified.\n | BI01010001010000000000000515BI0100001179 | 1 | EACH |
68 | 67 | Dismantling existing outdoor type feeder pillar box and removing from site and Supply, Installation, testing and commissioning factory fabricated LT Panel board (outdoor type) of size 1.20m(H) x 0.80m(L) x 0.60(W) to house under mentioned items weather dust and vermin proof fabricated out of 1.6mm thick CRCA steel sheet with suitable channel iron supports at the base duly painted with synthetic enamel paint including connection of incoming and outgoing cable with suitable size lugs and gland with the following:-\n(I) Aluminium bus bar for rating 300 amps on insulated support - 04 Nos.\n(ii) MCCB, FP 200 Amps, 36 KA for Incoming - 01 No. \n(iii) MCCB, FP, 160 Amps, 25KA for outgoing - 02 Nos \n(iv) MCCB, FP, 63 Amps, 16KA for outgoing - 02 Nos\n(v) Ampere meter 0-250 amps with suitable size of CTs- 01 No\n(vi) Voltmeter digital type 0-500 volts in built selector- 01 No\n(vii) Indicator Lamps set RYB- 01 No\n(viii) Necessary excavation, earthwork, PCC 1:4:8 type D2 and PCC 1:3:6 type C2 for platform complete as required- 01 No. | BI01010001010000000000000515BI0100001180 | 1 | EACH JOB |
69 | 68 | S&F Lightning arrestors suitable for HT 11KV, expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and as directed. | BI01010001010000000000000515BI0100001181 | 2 | EACH |
70 | 69 | M&L for boring of holes 1.5m below the road / hard surface with trenchless technology with mechanical boring equipment without damaging the existing road / hard surface and getting out in any type of soil and removal to a distance n.exc 50m complete all as specified and as directed. | BI01010001010000000000000515BI0100001182 | 15 | RM |
71 | 70 | Material and labour for applying one coat of primer and apply two coats of weather coat paint abrasion resistance, corrosion resistance, excellent adhesion with superior finish to RCC pole 11 mtr long including cross arms/street light bracket after preparation of existing painted surface including marking the strips of one feet each on pole with red and white Weather coat paint two coat upto 6 feet from the bottom of pole (Total 3 Nos strip of one feet each) and re-numbering of pole approved size of letter (Example : CZ- 001) with synthetic enamel paint on black colour background and white colour lettering complete all as specified and as directed. | BI01010001010000000000000515BI0100001183 | 300 | EACH |
72 | 71 | Material and labour for applying two coats of aluminium paint to steel tubular pole 9.00/9.50 mtr long including cross arms/street light bracket after preparation of existing painted surface including marking the strips of one feet each on pole with red and yellow flourscent synthetic enamel paint two coat upto 4 feet from the bottom of pole (Total 3 Nos strip of one feet each) and re-numbering of pole approved size of letter (Example : CZ- 001) with synthetic enamel paint on black colour background and white colour lettering complete all as specified and directed | BI01010001010000000000000515BI0100001184 | 215 | EACH |
73 | 72 | Material and labour for applying two coats of aluminium paint to steel tubular pole 11 mtr long including cross arms/street light bracket after preparation of existing painted surface including marking the strips of one feet each on pole with red and yellow flourscent synthetic enamel paint two coat upto 4 feet from the bottom of pole (Total 3 Nos strip of one feet each) and re-numbering of pole approved size of letter (Example : CZ- 001) with synthetic enamel paint on black colour background and white colour lettering complete all as specified and directed | BI01010001010000000000000515BI0100001185 | 80 | EACH |