Border Security Force-BSF has published Improvement 01 Jawan Barrack At Safdarjung Air Port Bsf Sh Electrification . Improvement Upgradation Of 01 Nos Jawan Barrack At Safdarjung Air Port Under Air Wing Bsf New Delhi Sh Electrification .. Submission Date for this Tender is 03-03-2021. Electrification Work Tenders in SAFDARJUNG AIR PORT NEW DELHI Delhi. Bidders can get complete Tender details and download the document.
Name of Work: Improvement/Upgradation of 01 Nos jawan Barrack at Safdarjung Air port under Air Wing BSF New Delhi.(SH: Electrification). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell\npoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C. Make Anchor Roma /Great white | 25 | Point | |
2 | 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||
3 | 2.1 | 3 x 1.5 sq. mm | 5 | Meter | |
4 | 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required | |||
5 | 3.1 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 35 | Meter | |
6 | 3.2 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 25 | Meter | |
7 | 3.3 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire | 30 | Meter | |
8 | 4 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.. Make Model Anchor | |||
9 | 4.1 | 3 Module (100mmX75mm) | 4 | Each | |
10 | 4.2 | 6 Module (200mmX75mm) | 8 | Each | |
11 | 4.3 | 8 Module (125mmX125mm) | 4 | Each | |
12 | 4.4 | 12 Module (200mmX150mm) | 2 | Each | |
13 | 5 | Supplying and fixing following modular switch/ socket ( Anchor - Roma/Greatwhite ) on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | |||
14 | 5.1 | 5/6 amps switch | 25 | Each | |
15 | 5.2 | 5 pin 5/6 amp socket outlet | 30 | Each | |
16 | 5.3 | 15/16 A switch | 6 | Each | |
17 | 5.4 | 15/16 A Socket | 6 | Each | |
18 | 6 | Supplying and fixing of following sizes of medium class PVC\nconduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required | |||
19 | 6.1 | 25mm | 4 | Meter | |
20 | 7 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing\njunction box/ wooden block including connections etc. as\nrequired. | 20 | Each | |
21 | 8 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | 2 | Each | |
22 | 9 | Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc as required. (but without MCB/ RCCB/Isolator) | |||
23 | 9.1 | (a)16 way, Double Door make Havells / Standard / L&T | 1 | Nos | |
24 | 10 | Supplying and fixing 5A to 32A rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following tables in the existing MCB DB complete with connections, testing and commisioning etc. as required. Make Havells/Standard/C&S | |||
25 | 10.1 | (a) Single Pole | 14 | Nos | |
26 | 11 | Supplying and fixing following rating, double pole, 240 V,\nisolator in the existing MCB DB complete with connections,\ntesting and commissioning etc. as required.. Make Standard/ Havells/C&S | |||
27 | 11.1 | 63 Amp | 1 | Nos | |
28 | 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. | |||
29 | 12.1 | 63 mm dia (OD-63 mm & ID-51 mm nominal) | 10 | mtrs | |
30 | 13 | Providing and fixing of full glow 4' 22/24 Watt 6500 K Decorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient ceilling/Wall mounting, ,complete with connection, testing etc. as reqd. Make Havells model no.LHEXACP7IN1S024 or equivalent of Philips/Havells/wipro/bajaj | 4 | Nos | |
31 | 14 | Supplying Installation Testing Commissioning of 450 mm (18") sweep wall Fan all metal construction heavy duty including fixing of base with the help of fastners etc as required. Make Orient Tornado wall II or equilent in havells/usha/bajaj | 10 | Each | |
32 | 15 | Providing and fixing of 2' x 2' LED slim light along with driver ceilling mounting, recessed type, 34/36 Watt 3000/6000 K, complete with connection, testing etc. as reqd. make Havells Endura slim pro plus or equivalent of Bajaj/CG/Philips | 8 | Each | |
33 | 16 | Supplying ,Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 2 x 25 sq. mm | 10 | mtrs | |
34 | 17 | Supplying, installation of 250mm fresh air/ventilating fan plastic body with louvers/ shutters complete with frame in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Make havells Model no. Ventil Air - DX White or equivalent of Bajaj/CG | 2 | Each |