Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Overhauling Of High Pressure Valves And Safety Valves Of Critical Piping And Other Associated Works Of Boiler Unit 7, Dtps, Anpara. Submission Date for this Tender is 12-03-2021. Safety Valves Tenders in DTPS,ANPARA. Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Mar-2021 | Extension of last date for submitting the bid | Date | 12-03-2021 |
Name of Work: Overhauling of high pressure valves and safety valves of critical piping and other associated works of Boiler unit 7, DTPS, Anpara. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Servicing /Revisioning of Main steam stop Valve (MSV-1&2). Nb - 500 mm, Design Pr. - 191.5 Kg/ sq.cm. | 1 | 2 | Nos. |
2 | 2 | Servicing/ Revisioning of Economizer Inlet Isolating gate Valve. Nb - 450 mm, Design Pr. - 320 Kg/ sq.cm. | 2 | 1 | Nos. |
3 | 3 | Servicing/ Revisioning of Economizer non return flap Valve. Nb - 450 mm, Design Pr. - 320 Kg/ sq. cm. | 3 | 1 | Nos. |
4 | 4 | Servicing/ Revisioning of SH Spray outlet Isolating valves and NRVs. Nb -125 mm, Np - 356 Kg/ sq.cm. | 4 | 6 | Nos. |
5 | 5 | Servicing/ Revisioning of High Pressure Hand operated Valves and NRVs . Nb – 10 to 100 mm. | 5 | 7000 | mm |
6 | 6 | Servicing/ Revisioning of High Pressure Hand operated Valves. Nb – 150 to 250 mm. | 6 | 3000 | mm |
7 | 7 | Servicing/ Revisioning of Motor operated High Pressure. Nb -20 to 100 mm. | 7 | 7000 | mm |
8 | 8 | Servicing/ Revisioning of Motor operated High Pressure valves. Nb -150 to 250 mm. | 8 | 3000 | mm |
9 | 9 | Servicing/ Revisioning of Boiler Drum Safety valves. Nb – 3”/6”, Design Pr. - 209 to 216 Kg/ sq. cm. | 9 | 6 | Nos. |
10 | 10 | Servicing/ Revisioning of MS line Safety valves. Nb – 3”/6”, Np - 185.5 Kg/ sq. cm. | 10 | 1 | Nos. |
11 | 11 | Servicing/ Revisioning of MS line Electromatic relief valves. Nb – 2.5”/4”, Np – 185 to 187 Kg/ sq. cm. Temp. - 540 deg. C | 11 | 5 | Nos. |
12 | 12 | Servicing/ Revisioning of Hot Re-heat & Cold Re-heat Safety valves. (a) CRH - Nb -6”/10”, Design Pr – 52.4 to 54 Kg/ sq. cm. (b) HRH – Nb -6”/8”, Design Pr – 49 to 50.5 Kg/ sq. cm. | 12 | 8 | Nos. |
13 | 13 | Servicing/ Revisioning of CBD Tank Safety valve. Nb – 150, Np - 16 Kg/ sq. cm. | 13 | 1 | Nos. |
14 | 14 | Servicing/ Revisioning of Soot blower PRV outlet Safety valves. Nb – 2.5”/4”, Np - 40 Kg/sq. cm. | 14 | 1 | Nos. |
15 | 15 | Servicing/revisioning of pneumatically operated control valve | 15 | 3 | Nos. |
16 | 16 | Replacement of gaskets of flanges and bonnets of valves. | 16 | 3500 | mm |
17 | 17 | Replacement of gland packing of High pressure valves. | 17 | 5000 | mm |
18 | 18 | Attending leakage of pipelines and headers etc. of Main Boiler | 18 | 500 | mm |
19 | 19 | Cleaning of Oil Strainer of Fuel Oil Station on firing floor. | 19 | 1 | Nos. |
20 | 20 | Servicing of Gear Box of Hand operated HP valves of Main Steam line, BCP, ERV etc. | 20 | 3 | Nos. |
21 | 21 | Replacement of Safety Valve of critical piping such As Boiler Drum, Main Steam line, Reheater line etc. | 21 | 1 | Jobs |
22 | 22 | Replacement of High pressure valve (motor operated/Hand operated) of critical piping of Boiler of size 10 - 25 mm. | 22 | 45 | Jobs |
23 | 23 | Replacement of High pressure valve (motor operated/Hand operated) of critical piping of Boiler of size 40 - 50 mm. | 23 | 10 | Jobs |
24 | 24 | Replacement of High pressure valve (motor operated) hand operated) of critical piping such as Main Steam, Final Super Heater, Primary Super Heater, CBD etc. of size 65 - 150 | 24 | 4 | Jobs |
25 | 25 | Servicing/ Revisioning of Heavy & Light Oil valves (pneumatic operated ) as HOTV, LOTV,HOCV,LOCV,HORTV,LORTV Nb –40-100 mm, Working Pr. -15/ 22 Kg/sq. cm. | 25 | 10 | Nos. |
26 | 26 | Servicing/replacement of Air/HFO/LFO/Steam pneumatically operated Trip valves at all elevations | 26 | 4 | Nos. |
27 | 27 | Servicing/replacement of Air/HFO/LFO/Steam lines valves and NRVs at all elevations | 27 | 1500 | mm |
28 | 28 | Servicing/ Revisioning of Hot Re-heat Electromatic relief valves. Nb – 6”/8”, Np – 48 to 48.5 Kg/ sq. cm. Temp. - 540 deg. C | 28 | 4 | Nos. |
29 | 29 | Servicing/ Revisioning of blow down valve Motor operated Valves .Nb – 40 mm , Design Pr.-210.8 kg/cm2. | 29 | 2 | Nos. |
30 | 30 | Servicing/ Revisioning of Diaphram Actuated Head valve DAHV( pneumatic) .Nb – 50 mm , Design Pr.-40 kg/cm2. | 30 | 2 | Nos. |
31 | 31 | Blanking of Hot reheat and cold reheat isolating device ( Dia. 660 mm) by blanking device and normalising the same. | 31 | 4 | Nos. |
32 | 32 | Servicing/ Revisioning of pneumatically operated block Valve & Control Valve of Super heater attemparation line. Nb – 125 to 200 mm, Design Pr. –356 Kg/ sq.cm. | 32 | 9 | Nos. |
33 | 33 | Servicing/ Revisioning of pneumatically operated block Valve & Control Valve of Reheater attemparation line. Nb – 65 to 100 mm, Design Pr. – 176 Kg/ sq.cm. | 33 | 9 | Nos. |
34 | 34 | Servicing/ Revisioning of RH Spray outlet Isolating valves. Nb -65 mm, Np - 176 Kg/ sq.cm. | 34 | 4 | Nos. |
35 | 35 | Servicing/ Revisioning of Soot blowing PRV and other similar valve . Nb 50 to 100 mm, Np – 198.9 Kg/ sq.cm | 35 | 1 | Nos. |
36 | 36 | Servicing/ Revisioning of pneumatically operated Thermal drain valve and other similar valves. Nb – 25, Design Pr.- 40 Kg/cm2 | 36 | 2 | Nos. |
37 | 37 | Servicing / Revisioning of Boiler Circulation Pump Elbow down stop check valve, Nb – 350/300 mm, Design Pr. – 213.8 Kg/sq.cm | 37 | 6 | Nos. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail