Replacement Of 600Mm I/D Flow Sensor And Recalibration Of New Flow Sensor With Existing Electronic Signal Convertors Ifc-021 Alongwith Lpu/Cvts Signal And Power Cables Inlet Line From Water Works Sector-52 Chandigarh, Works-Chandigarh

Municipal Corporation-MC has published Replacement Of 600Mm I/D Flow Sensor And Recalibration Of New Flow Sensor With Existing Electronic Signal Convertors Ifc-021 Alongwith Lpu/Cvts Signal And Power Cables Inlet Line From Water Works Sector-52 Chandigarh. Submission Date for this Tender is 02-03-2021. Power Cable Tenders in Works Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

27073136
Replacement Of 600Mm I/D Flow Sensor And Recalibration Of New Flow Sensor With Existing Electronic Signal Convertors Ifc-021 Alongwith Lpu/Cvts Signal And Power Cables Inlet Line From Water Works Sector-52 Chandigarh
Open Tender
Indian
Chandigarh
Works
02-03-2021

Tender Details

Replacement Of 600Mm I/D Flow Sensor And Recalibration Of New Flow Sensor With Existing Electronic Signal Convertors Ifc-021 Alongwith Lpu/Cvts Signal And Power Cables Inlet Line From Water Works Sector-52 Chandigarh

Key Value

Document Fees
INR 1000 /-
EMD
INR 23841.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPLACEMENT OF 600MM I/D FLOW SENSOR & RE-CALIBRATION OF NEW FLOW SENSOR WITH EXISTING ELECTRONIC SIGNAL CONVERTORS IFC-021 ALONGWITH LPU/CVT's, SIGNAL & POWER CABLES ETC. INLET LINE FROM WATER WORKS, SECTOR-52, CHANDIGARH. (Ch. To : Revenue Head). APPROX. AMOUNT : RS. 11.92 Lakh; EMD : RS. 23,841/- ; TIME LIMIT : THREE MONTHS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Replacement of Power Supply Cable for Krohne Marshall Make: flow sensor as per design of manufacturer from supply line to convertor & from convertor to Flow sensor (NSI) BI01010001010000000000000515BI0100001113 20 P.mtr.
2 2 Replacement of Instrumentation cable for Krohne Marshall make flow sensor as per design of manufacturer for flow convertor to flow sensor (NSI) BI01010001010000000000000515BI0100001114 20 P.mtr.
3 3 Replacement of re-setting of Lightening Protection Unit for protection o flow eter consisting of 1 No. AC power surge protection devices and 1 No. Analogue I/P SPD complete with enclosure for mounting of LPU's and making arrangement for connection with flow meter as per specification of the manufacturer. Make: MTL/Pepperl & Fuchs\nMaximum leakage current: <1?A at working voltage\nWorking voltage: DC - 32V\nMaximum continuous operating voltage: DC-36V\nIn line Resistance per loop : 4 Ohm\nAmbient temperature limits: -40ºC to +70ºC (working)\nLimiting voltage: <38V@1kV/us,\nCase Flammability : UL94-V0 (NSI) BI01010001010000000000000515BI0100001115 1 P.set
4 4 Replacement of Constant Voltage Transformer as per speciications given as under including cost of cable etc. complete in all respect. \na) INPUT VOLTAE: 180 TO 260V, AC/1PH/50±2HZ\nb) OUTPUT VOLTAGE: 200VAC/230V AC±1%\nc) Frequency Effect: Approx. 1.5% change in output voltage, for 1% change in input frequency.\nd) Efficiency: 90% typical at full load Common-Mode-Noise attnuation: 1:3000, typical (10KHZ to 5 MHZ; 85 to 21DB, type)\ne) Output Wave Form: Sinsodial type harmonic distrotion\nf) Output Voltage correction: 2 Cycle (max) for no load to full load operating.\nh) Make: ELNOVA/PACE/LOGITECH (NSI) BI01010001010000000000000515BI0100001116 1 Each
5 5 Supplying and laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc. confirming to IS 14930, Part-II complete with fitting an cutting, jointing etc. in the existing trench complete as required. (NSI)\n BI01010001010000000000000515BI0100001117
6 5.01 40mm dia (OD-40mm & ID-32mm) nominal BI01010001010000000000000515BI0100001118 20 P.mtr.
7 6 Replacement and Re-calibratin of Flow Sensor DN 600 Model, Type Electro Magnetic in SS304 Steel Sheet with hard rubber liner having SS316 Electrodes with grounding rings of SS 316, Flanged to ANSI 150 # CS SORF non-hazardous with M20x1.5 cable entry in protection Class IP67 t mae it compatible with existing Signal converter of Krohne Marshall Model IFC-021 for Electro Magnetic Flow Sensor Model Aquaflux of Krohne Marshall: IFC-021 Type Microprocessor based accuracy: +0.5% of measured value Max Load: 500 Ohms display: Large back lit LCD Display Parameters Actual flow rate, totalized flow, flow velocity (at constant density) Diagnostics: Empty pipe Detection Local Indication: Programmable Power Supply: 85-250VAC, 48-63Hz. Protection Class: IP/67 without Housing to be compatible with existing SCADA system through manufacturer (NSI) BI01010001010000000000000515BI0100001119 1 Each
8 7 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (As per DSR I. No. 2.8.1) BI01010001010000000000000515BI0100001120 57 P.cum
9 8 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. All kinds of soil. (As per DSR I. No. 2.25) BI01010001010000000000000515BI0100001121 57 P.cum
10 9 Providing, fixing, testing and commissioning MCB 6 Amp. 2 pole, as per IS specifications complete with enclosure (NSI) BI01010001010000000000000515BI0100001122 1 Each
11 10 Providing, laying, testing and commissioning of 2.5mmx2 core armoured cable for main incoming connection from panel to flow meter for Electro Magnetic Flow sensors of make: Krohne Marshall (NSI) BI01010001010000000000000515BI0100001123 15 P.mtr.
12 11 Credit against Old defective material:- BI01010001010000000000000515BI0100001124
13 11.01 Old flow sensor size 600mm BI01010001010000000000000515BI0100001125 1 Each
14 11.02 Constant voltage transformer BI01010001010000000000000515BI0100001126 1 Each
15 11.03 Lightning Protection Unit BI01010001010000000000000515BI0100001127 1 Each