Wapcos Limited has published Hvac At Districtdrugwarehousemanjeri Hvac At District Drug Warehouse Manjeri. Submission Date for this Tender is 03-05-2021. HVAC Tenders in Manjeri Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 05-Mar-2021 | fee corrigendum | Fee | 13-03-2021 |
2 | 09-Mar-2021 | Date Corrigendum2 | Date | 29-03-2021 |
3 | 27-Mar-2021 | date Corrigendum | Date | 07-04-2021 |
4 | 07-Apr-2021 | Date Corrigendum3 | Date | 14-04-2021 |
5 | 13-Apr-2021 | date | Date | 20-04-2021 |
6 | 20-Apr-2021 | Corrigendum 5 | Date | 27-04-2021 |
7 | 27-Apr-2021 | Corrigendum 6 | Date | 03-05-2021 |
Work Name : Installation of HVAC at District Drug Warehouse, Manjeri Malappuram | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | HIGH SIDE PART -A | BI01010001010000000000000515BI0100001113 | ||
2 | 1.01 | od209235/2020_2021 : Supply of ceiling suspended air cooled ductable split air-conditioners each complete with BLDC Motors for indoor unit, Inverter scroll compressor, air cooled condenser with black fin coating and epoxy coating all the coatings to be covered under manufacture warranty, GSS casing, filters, cooling coils, R410 A refrigernet DC fan motors, corded remote with fan speed and ESP setting Electronic expansion valve refrigerant controls and accessories complete for following unit. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%,3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5<br><br>11 TR, 4400 CFM HIGH STATIC INVERTER DUCTABLE SPLIT UNIT | BI01010001010000000000000515BI0100001114 | 4 | no |
3 | 2 | LOW SIDE - PART B | BI01010001010000000000000515BI0100001115 | ||
4 | 2.01 | od209236/2020_2021 : Installation, testing, and commissioning of 11 TR High static Ductable Air conditioner | BI01010001010000000000000515BI0100001116 | 4 | no |
5 | 2.02 | od209237/2020_2021 : Supply installation testing and commissioning including vaccumization and nitrogen testing of Hard drawn copper refrigerant piping interconnecting evaporator and condensing units, complete with all fittings, duly insuated with antimicrobial class O closed cell elastomeric nitrile rubber tubular sleeve of 19mm thickness for suction and discharge line. Density of insulation material shall be 40 to 55 kg/m3 and thermal conductivity shall not exceed 0.035 w/(m.K.) Refrigerant pipe size should be selected as per equipment manufacturer's recommendations. | BI01010001010000000000000515BI0100001117 | 26 | RM |
6 | 2.03 | od209238/2020_2021 : Supply, installation and testing of uPVC sch.40 condensate drain piping with thermal insulation of 9mm thick class O anti-microbial nitrile rubber | BI01010001010000000000000515BI0100001118 | 20 | RM |
7 | 2.04 | od209239/2020_2021 : Electrical control cabling<br>Control wiring between indoor and outdoor units with copper/ aluminium cabling. | BI01010001010000000000000515BI0100001119 | 42 | RM |
8 | 2.05 | od209240/2020_2021 : <br>Supply of MS support stand for 11 TR Outdoor units with proper clamping | BI01010001010000000000000515BI0100001120 | 4 | no |
9 | 2.06 | 16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. | BI01010001010000000000000515BI0100001121 | 3.5 | sqm |
10 | 2.07 | od333516/2020_2021 : Supply installation testing and commissioning of Fresh Air louvers with bird screen with VCD. | BI01010001010000000000000515BI0100001122 | 0.5 | sqm |
11 | 2.08 | od209241/2020_2021 : Supply of Support stand for indoor units & duct of MS with proper clamping | BI01010001010000000000000515BI0100001123 | 4 | set |
12 | 2.09 | od209242/2020_2021 : Supply, installation, testing and commissioning of GSS rectangular duct as per drawings. complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter, dampers, indoors, transformation pieces etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs.(only hitech supports shall be used). Thickness - 24 Gauge | BI01010001010000000000000515BI0100001124 | 214 | sqm |
13 | 2.1 | od209243/2020_2021 : GSS DuctingCanvas Connection | BI01010001010000000000000515BI0100001125 | 4 | no |
14 | 2.11 | od209244/2020_2021 : Supply , installation, testing & commissioning of 9mm thick duly laminated aluminium foil of mat finish closed cell anti-microbial Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber.The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Density of insulation material shall be between 40 to 55 Kg/m3 and and thermal conductivity shall not exceed 0.035 w/(m.K. ) | BI01010001010000000000000515BI0100001126 | 155.5 | sqm |
15 | 2.12 | od209245/2020_2021 : Supply , installation, testing & commissioning of 10mm thick, Class 1 rated open cell anti-microbial Nitrile rubber for acoustic insulation of ducts using suitable adhesive as per the recommendation of the insulation manufacturer. Density of insulation material shall be between 140 to 180 Kg/m3 and and thermal conductivity shall not exceed 0.047 w/(m.K.) | BI01010001010000000000000515BI0100001127 | 60 | sqm |
16 | 2.13 | od209246/2020_2021 : Additional Refrigerant gas R410A | BI01010001010000000000000515BI0100001128 | 5.4 | kg |
17 | 3 | PARTITION WORKS | BI01010001010000000000000515BI0100001129 | ||
18 | 3.01 | od210050/2020_2021 : Double Skin Aluminium Panel Partition :<br>Providing and fixing in position factory made sandwich panels made of light weight insulated sandwiched panel of 0.5 mm thickness for aluminium sheets. Injected polyurethene foam of 50mm thickness and 40 kg/m3 density to be sandwiched between composite panels with necessary supports, accessories required to support the panels rigidly | BI01010001010000000000000515BI0100001130 | 37 | sqm |