Public Works Department-PWD has published Computerization And Air Conditioning Of Common Computer Facility Lab , Robotics Lab , Hard Ware Lab , Software Lab And Seminar Hall At Ezhukone Poly Technique College For The Continuation Of Aicte Affiliation Computerization And Air Conditioning Of Com. Submission Date for this Tender is 27-02-2021. Air Conditioner Tenders in Government poly technique college Ezhukone Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Feb-2021 | Extension of time | Date | 27-02-2021 |
Work Name : Computerization and Air conditioning of Common Computer Facility lab ,Robotics lab,Hard ware lab,Software lab and Seminar hall at Ezhukone poly technique college for the continuation of AICTE Affiliation. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Part-I Electrification | BI01010001010000000000000515BI0100001113 | ||
2 | 1.01 | 90.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | BI01010001010000000000000515BI0100001114 | 3 | point |
3 | 1.02 | 90.2.1.4 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | BI01010001010000000000000515BI0100001115 | 4 | point |
4 | 1.03 | 90.2.1.7 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point | BI01010001010000000000000515BI0100001116 | 1 | each |
5 | 1.04 | 90.3.20.3 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | BI01010001010000000000000515BI0100001117 | 13 | each |
6 | 1.05 | 90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | BI01010001010000000000000515BI0100001118 | 4 | each |
7 | 1.06 | 90.4.5.4 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm down rod , 2 number canopies, shackele kit, Copper winding, 3 number blades and all remaining accessories including safety pin, nut bolts, washers suitable for 230V/240V single phase AC supply etc. complete as required | BI01010001010000000000000515BI0100001119 | 5 | each |
8 | 1.07 | 90.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm | BI01010001010000000000000515BI0100001120 | 415 | metre |
9 | 1.08 | 90.6.10.2 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm | BI01010001010000000000000515BI0100001121 | 282 | metre |
10 | 1.09 | 90.6.10.3 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm | BI01010001010000000000000515BI0100001122 | 5 | metre |
11 | 1.1 | od1639/2019_2020 : Supply and fixing 20 mm dia PVC flexible conduit with accessories on surface of wall making good the damages etc as required. | BI01010001010000000000000515BI0100001123 | 20 | metre |
12 | 1.11 | od1641/2019_2020 : Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required. 32mm dia | BI01010001010000000000000515BI0100001124 | 20 | metre |
13 | 1.12 | 90.9.2.1 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid | BI01010001010000000000000515BI0100001125 | 60 | metre |
14 | 1.13 | 90.9.2.2 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider | BI01010001010000000000000515BI0100001126 | 120 | metre |
15 | 1.14 | 90.9.2.3 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree | BI01010001010000000000000515BI0100001130 | 10 | each |
16 | 1.15 | 90.9.2.7 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat cross | BI01010001010000000000000515BI0100001147 | 10 | each |
17 | 1.16 | 90.9.2.9 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flanged coupler | BI01010001010000000000000515BI0100001116 | 10 | each |
18 | 1.17 | 90.9.2.11 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer | BI01010001010000000000000515BI0100001117 | 10 | each |
19 | 1.18 | 90.9.2.4 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree | BI01010001010000000000000515BI0100001118 | 6 | each |
20 | 1.19 | 90.9.2.5 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree | BI01010001010000000000000515BI0100001119 | 4 | each |
21 | 1.2 | 90.9.2.6 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal coupler | BI01010001010000000000000515BI0100001120 | 2 | each |
22 | 1.21 | 90.9.2.8 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap | BI01010001010000000000000515BI0100001121 | 8 | each |
23 | 1.22 | 90.9.2.10 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover | BI01010001010000000000000515BI0100001122 | 2 | each |
24 | 1.23 | 90.9.2.14 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box | BI01010001010000000000000515BI0100001123 | 70 | each |
25 | 1.24 | 90.9.2.16 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Wall plate for internal angle | BI01010001010000000000000515BI0100001124 | 4 | each |
26 | 1.25 | 90.6.4.2 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 2 Run | BI01010001010000000000000515BI0100001125 | 25 | metre |
27 | 1.26 | 90.6.4.4 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 4 Run | BI01010001010000000000000515BI0100001126 | 40 | metre |
28 | 1.27 | 1.17.2 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm | BI01010001010000000000000515BI0100001130 | 108 | metre |
29 | 1.28 | 1.17.4 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm | BI01010001010000000000000515BI0100001161 | 124 | metre |
30 | 1.29 | 1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | BI01010001010000000000000515BI0100001162 | 135 | metre |
31 | 1.3 | 1.17.8 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm | BI01010001010000000000000515BI0100001163 | 38 | metre |
32 | 1.31 | 1.17.10 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.10 x 1.5 sq. mm | BI01010001010000000000000515BI0100001164 | 54 | metre |
33 | 1.32 | 1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm | BI01010001010000000000000515BI0100001165 | 80 | metre |
34 | 1.33 | 1.17.13 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm | BI01010001010000000000000515BI0100001166 | 2 | metre |
35 | 1.34 | 1.17.20 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm | BI01010001010000000000000515BI0100001167 | 41 | metre |
36 | 1.35 | 1.17.22 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm | BI01010001010000000000000515BI0100001168 | 265 | metre |
37 | 1.36 | 1.17.29 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm | BI01010001010000000000000515BI0100001169 | 56 | metre |
38 | 1.37 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | BI01010001010000000000000515BI0100001170 | 338 | each |
39 | 1.38 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | BI01010001010000000000000515BI0100001171 | 507 | each |
40 | 1.39 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | BI01010001010000000000000515BI0100001172 | 6 | each |
41 | 1.4 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | BI01010001010000000000000515BI0100001130 | 6 | each |
42 | 1.41 | 2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001147 | 8 | each |
43 | 1.42 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001149 | 6 | each |
44 | 1.43 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | BI01010001010000000000000515BI0100001150 | 1 | each |
45 | 1.44 | 90.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface | BI01010001010000000000000515BI0100001151 | 30 | each |
46 | 1.45 | 1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module | BI01010001010000000000000515BI0100001152 | 100 | each |
47 | 1.46 | 1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) | BI01010001010000000000000515BI0100001153 | 69 | each |
48 | 1.47 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | BI01010001010000000000000515BI0100001154 | 9 | each |
49 | 1.48 | 90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001155 | 1 | each |
50 | 1.49 | 90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001156 | 1 | each |
51 | 1.5 | 2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001157 | 9 | each |
52 | 1.51 | od1924/2019_2020 : Supplying and fixing following way, sheet steel, MCB enclosure suitable for 4 pole MCB, 240 volts, on surface/ recess, complete with powder painted including earthing etc. as required. (But without MCB/RCCB/ isolator)4 way, Single door | BI01010001010000000000000515BI0100001158 | 9 | each |
53 | 1.52 | 90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL | BI01010001010000000000000515BI0100001159 | 1 | no |
54 | 1.53 | 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001160 | 10 | each |
55 | 1.54 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001161 | 9 | each |
56 | 1.55 | 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001162 | 1 | each |
57 | 1.56 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001163 | 1 | each |
58 | 1.57 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001164 | 80 | each |
59 | 1.58 | 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole | BI01010001010000000000000515BI0100001165 | 9 | each |
60 | 1.59 | od1966/2019_2020 : Supplying and fixing 40 A, TP MCB (C curve), 10 kA breaking capacity rating, 240/415 volts,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole | BI01010001010000000000000515BI0100001166 | 1 | each |
61 | 1.6 | 2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | BI01010001010000000000000515BI0100001167 | 30 | each |
62 | 1.61 | od56036/2020_2021 : Suply & fixing the following multi-function meters in the panel assemblyThree phase multifunction meters to read V, A and F, accuracy class 0.5 | BI01010001010000000000000515BI0100001168 | 2 | each |
63 | 1.62 | 90.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp | BI01010001010000000000000515BI0100001169 | 75 | metre |
64 | 1.63 | 90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp | BI01010001010000000000000515BI0100001170 | 60 | metre |
65 | 1.64 | 9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm) | BI01010001010000000000000515BI0100001171 | 2 | set |
66 | 1.65 | 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) | BI01010001010000000000000515BI0100001172 | 2 | set |
67 | 1.66 | od56032/2020_2021 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.4SQMM TO16SQMM | BI01010001010000000000000515BI0100001180 | 2 | each |
68 | 1.67 | od56034/2020_2021 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for cables 25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip as required. | BI01010001010000000000000515BI0100001180 | 2 | each |
69 | 1.68 | 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001181 | 2 | set |
70 | 1.69 | od1405/2019_2020 : Supply and providing test joint for the earthing system using 2 NOs of the following sizes of strips including cutting and bending to shape ,drilling necessary holes and fixed to the watering pipe etc as required 2x25x3 mm tinned copper strip | BI01010001010000000000000515BI0100001182 | 1.5 | metre |
71 | 1.7 | 90.16.1.1 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) | BI01010001010000000000000515BI0100001183 | 696 | metre |
72 | 1.71 | 90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | BI01010001010000000000000515BI0100001184 | 755 | metre |
73 | 1.72 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | BI01010001010000000000000515BI0100001185 | 250 | metre |
74 | 1.73 | 90.16.2.1 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) | BI01010001010000000000000515BI0100001186 | 12 | metre |
75 | 1.74 | 90.16.5.1 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) | BI01010001010000000000000515BI0100001187 | 900 | each |
76 | 1.75 | 90.16.5.2 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) | BI01010001010000000000000515BI0100001188 | 60 | each |
77 | 1.76 | 90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) | BI01010001010000000000000515BI0100001189 | 30 | each |
78 | 1.77 | od1409/2019_2020 : Supply and providing 25x3mm brass nut and bolt etc. as required. | BI01010001010000000000000515BI0100001190 | 225 | each |
79 | 1.78 | od1410/2019_2020 : Supply and providing 25x6mm brass nut and bolt etc. as required. | BI01010001010000000000000515BI0100001191 | 30 | each |
80 | 1.79 | od1423/2019_2020 : Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as required | BI01010001010000000000000515BI0100001192 | 25 | each |
81 | 1.8 | od103856/2019_2020 : S & F following HRC fuses2 -80A, DIN type fuse link of size 000 | BI01010001010000000000000515BI0100001193 | 9 | each |