Repair / Maint And Overhauling Of Lt Servo Type Voltage Stabilizers , Lt Air Circuit Breakers Ups And Allied Works At Different Otm Accn / Technical Building In Army Area Jodhpur Under Ge ( Army ) Utility Jodhpur, GARRISON ENGINEER ARMY UTILITY MULTAN LINE JODHPUR-Rajasthan

Military Engineer Services-MES has published Repair / Maint And Overhauling Of Lt Servo Type Voltage Stabilizers , Lt Air Circuit Breakers Ups And Allied Works At Different Otm Accn / Technical Building In Army Area Jodhpur Under Ge ( Army ) Utility Jodhpur. Submission Date for this Tender is 12-03-2021. Air Circuit Breaker Tenders in GARRISON ENGINEER ARMY UTILITY MULTAN LINE JODHPUR Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

27019325
Corrigendum : Repair / Maint And Overhauling Of Lt Servo Type Voltage Stabilizers , Lt Air Circuit Breakers Ups And Allied Works At Different Otm Accn / Technical Building In Army Area Jodhpur Under Ge ( Army ) Utility Jodhpur
National Competitive Bid
Indian
Rajasthan
GARRISON ENGINEER ARMY UTILITY MULTAN LINE JODHPUR
12-03-2021

Tender Details

Repair / Maint And Overhauling Of Lt Servo Type Voltage Stabilizers , Lt Air Circuit Breakers Ups And Allied Works At Different Otm Accn / Technical Building In Army Area Jodhpur Under Ge ( Army ) Utility Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 17900.0 /-
Tender Value
INR 8.95 Lakhs /-

BOQ Items

Name of Work: Repair / Maint and overhauling of LT Servo Type Voltage Stabilizers, LT Air Circuit Breakers UPS and allied works at different OTM Accn / Technical Building in Army Area Jodhpur under GE (Army) Utility Jodhpur
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for disconnecting electric connection from incoming and out going of servo voltage stabilizer 3 phase balanced/ unbalanced load type, opening and dismantling the complete unit of Servo Controlled voltage stabilizer of capacity 250 KVA to 300 KVA 3 phase 50 C/S AC supply of any make complete including taking out insulation oil and keep aside Fault detection, repairing and rectification of defects servicing all moveable and static parts and accessories including repairing/replacing all defective parts such as old sleeves, bolts, nuts washers/wires, hooks etc including tightening of all loose connections and repair to all other minor accessories as required at site Re-assembling / commissioning/ testing the servo conrolled stabilizer unit complete after required repairs and fixing the various parts assembly in housing/tank, making complete internal electric/mechanical connections, replacement of unserviceable metering instruments, selector switches etc all as specified and as directed including painting the stabilizer by scrapping the old paint and preparing old surface and applying two coats of synthetic enameled existing colour paint externally over a coat of red oxide primer paint and writing SM/MES Nos and capacity of stabilizer and connecting including cutting existing cable preparation of cable ends, providing aluminium/copper cable lugs of suitable size and all as directed by Engr-in-Charge .Note: Spare parts will be measured and paid separately under relevant "supply and fixing" items. 2 Each job
2 2 Supply and fixing of spare parts for 250 KVA/300 KVA servo controlled stabilizer for repair/overhauling under Sl item No.1 above.\n(a) Servo motor single phase, 50 Hz, 240 volts, 10 kg torque, 60 RPM. 6 Each
3 2.01 (b) Carbon brush with holder complete 12 Each
4 2.02 (c) Electronic sensing card (PCB) 6 Each
5 2.03 (d) RC Net work set 6 Each
6 2.04 (e) PCB connector 6 Each
7 2.05 (f) Variac Gear 4 Each
8 2.06 (g) Carbon brush fingers 12 Each
9 2.07 (h) Variac Control CT 6 Each
10 2.08 (j) Main Bushing with brass rod (insulator & rod) 4 Each
11 2.09 (k) High low cut off relay 4 Each
12 2.1 (l) Electronic sensing transformer 2 Each
13 2.11 (m) Wiring Set complete 2 Each
14 2.12 (n) Motor Gear 6 Each
15 2.13 (o) Variac(dimmerstat) assy copper wound (continuously variable voltage auto transformer) for 250 KVA/300 KVA servo voltage stabilizer oil cooled, input voltage 300 to 440 volts out put 415 volts + 1% as per existing r all as directed by engineer in charge 1 Each
16 3 All as per Sl item No 2 but of capacity 100 to 150 KVA 3 phase 50 C/S AC supply of any make complete all as directed by Engr-in-Charge. 3 Each Job
17 4 Supply and fixing spare parts for 100 to 150 KVA servo controlled stabilizer for repair/overhauling under Sl item No3 above.\n(a) Servo motor single phase, 50 Hz, 240 volts, 10 kg torque, 60 RPM 9 Each
18 4.01 (b) Variac(dimmerstat) assy copper wound (continuously variable voltage auto transformer) for 100/150 KVA servo voltage stabilizer oil cooled input voltage 300 to 440 volts out put 415 volts + 1% as per existing all as directed by engineer in charge 1 Each
19 4.02 (c) Carbon brush with holder complete 9 Each
20 4.03 (d) Electronic sensing card (PCB) 3 Each
21 4.04 (e) RC Net work set 3 Each
22 4.05 (f) PCB connector 6 Each
23 4.06 (g) Variac Gear 9 Each
24 4.07 (h) Carbon brush fingers 9 Each
25 4.08 (j) Variac Control CT 6 Each
26 4.09 (k) Main Bushing with brass rod (insulator & rod) 12 Each
27 4.1 (l) High low cut off relay 3 Each
28 4.11 (m) Electronic sensing transformer 3 Each
29 4.12 (n) Wiring Set complete 3 Each
30 4.13 (o) Motor Gear 6 Each
31 5 S&F Aluminium lugs of size 16 Sqmm 24 Each
32 6 S&F Aluminium lugs of size 25 Sqmm 24 Each
33 7 S&F Aluminium lugs of size 35 Sqmm 24 Each
34 8 S&F Aluminium lugs of size 50 Sqmm 24 Each
35 9 S&F Aluminium lugs of size 70 Sqmm 16 Each
36 10 S&F Aluminium lugs of size 95 Sqmm 16 Each
37 11 S&F Aluminium lugs of size 120 Sqmm 16 Each
38 12 S&F Aluminium lugs of size 150 Sqmm 16 Each
39 13 S&F Aluminium lugs of size 185 Sqmm 16 Each
40 14 S&F Aluminium Lugs of size 240 Sqmm 16 Each
41 15 S&F Push switch for manual voltage regulation 5 Each
42 16 S&F Volt meter 0 to 500 Volts (Digital Type 96x96 mm flush monitoring) 4 Each
43 17 S&F Amp meter 0- 200 Amps (Digital Type 96x96 mm flush monitoring) 4 Each
44 18 S&F Volt meter 0 to 300 Volts for measuring single phase voltage (Analogue Type 60x60 mm flush monitoring) 6 Each
45 19 S&F Voltage Selector switch 6 Each
46 20 S&F Amp Selector switch 6 Each
47 21 S&F Limit switch 5 Each
48 22 S&F CT of ratio 400/5 9 Each
49 23 S&F CT of ratio 200/5 9 Each
50 24 S&F Toggle swith for Auto manual operation 10 Each
51 25 M & L for repair/ Servicing to Online UPS of rating 25 KVA Capacity suitable for 415 Volts, AC, 50 Hz, three phase complete of any make/type all as specified and directed including cleaning and segregation of serviceable and unserviceable components. 1 Each Job
52 26 M&L for in replacement of Electronic sensing card (PCB) for Online UPS 25 KVA, 415 Volts, AC, 50 Hz, three phase complete as specified and directed 1 Each Job
53 27 M & L for repair/ Servicing to Online UPS 15 KVA Capacity suitable for 415 Volts, AC, 50 Hz,Single phase complete as specified and directed 1 Each Job
54 28 M&L for in replacement of Electronic sensing card (PCB) for Online UPS 15 KVA, 415 Volts, AC, 50 Hz, Single phase complete as specified and directed 1 Each Job
55 29 M & L for repair to battery bank by replacement of lead acid batteries dry type each of 12 Volts, 75 AH complete connected in series suitable for 25 KVA on line UPS with battery input voltage 360V DC. Type: Powersafe plus, EP-75-12 Make: Exide or equivalent 30 Each
56 30 M & L for repair to battery bank by replacement of lead acid batteries each of 12 Volts, 18 AH complete connected in series suitable for 15 KVA on line UPS with battery input voltage 360V DC Type: Powersafe plus, EP-18-12 Make: Exide or equivalent 30 Each
57 31 M&L for carrying out filtration of insulation oil to bring the dielectric strength of oil upto 50 KV and removing of sludge and filling in the voltage stabilizer taken all as specified and directed by Engr-in-Charge. 1200 Ltrs
58 32 Supply and filling of insulation oil confirming to IS-335 having dielectric strength 55-60KV for topping up voltage stabilizer all as specified and directed by Engr-in-Charge. 418 Ltrs
59 33 Taking out LT 3 phase 1000 amp rating Air Circuit Breaker from LT panel board by disconnecting incoming and out going cables for necessary repair.Dismantling of complete ACB, segregation of serviceable and unserviceable components, carrying out cleaning of all parts using CRC, air blower, carrying out minor repair to serviceable components and replacement of following unseviceable spares and assembling, testing and re installation and connection in LT panle board all as specified and directed by Engr-in-Charge.\n(a) S & F Jaw Contact\n(b) S & F Cradle Terminal\n(c) S & F Cradle Base\n(d) S & F Safety Shutter\n(e) S & F Maintenance Kit 1 Each Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail