T . T . Palli-Iv R/L Revival And Energisation Of L . I . Project . , T.T. Palli under Aska Block-Odisha

Orissa Lift Irrigation Corporation Limited has published T . T . Palli-Iv R/L Revival And Energisation Of L . I . Project . . Submission Date for this Tender is 17-02-2021. Lift Irrigation Tenders in T.T. Palli under Aska Block Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

26914998
T . T . Palli-Iv R/L Revival And Energisation Of L . I . Project .
Open Tender
Indian
Odisha
T.T. Palli under Aska Block
17-02-2021

Tender Details

Revival & Energisation Of T.T.Palli – Iv R / L L.I. Project Under Aska Block In Ganjam District Out Of State Plan Grant 2020-21

Key Value

Document Fees
INR 6000 /-
EMD
INR 11710.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:- Revival & Energisation of T.T.Palli – IV R/L L.I. Project under Aska Block in Ganjam District out of STATE PLAN Grant 2020-21
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Schedule A ( Civil Works & Supply of Materials)
2 2 Earth work in hard soil for excavation of foundation including dressing and levlling the bed and depositing the soil within 50 mtr. initial lead and 1.5 mtr. initial lift as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001113 311.89 Cum
3 3 Filling in foundation and plinth with sand well watered and rammed including cost of sand as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001114 17.2 Cum
4 4 C.C(1:4:8) with 4 Cm. size H.B.G metal laying and hoisting etc. complete with curing as per direction of Engineer-in-charge BI01010001010000000000000515BI0100001115 1.55 Cum
5 5 Brick work with Fly ash bricks of (23cm x 11 cm x 8 cm ) in cement mortar (1:6) in foundation and plinth with curing etc.complete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001116 4.74 Cum
6 6 Cement concrete (1:2:4) for R.C.C. works with 12mm size h.g.b. chips including hoisting and laying etc. complete with curing as per direction of Engineer-in-charge BI01010001010000000000000515BI0100001117 2.575 Cum
7 7 Providing & supplying of M.S.Rod for for M.S. Reinforcement for R.C.C work including cutting, bending, binding & tying the grills & placing in position including cost of binding wire etc.complete as per direction of Engineer-in-charge BI01010001010000000000000515BI0100001118 1.65 Qntl
8 8 Rigid smooth centering and shuttering for R.C.C. works including false work and dismentling them after casting including cost of materials complete etc. complete for Slab,Column,Beam etc. BI01010001010000000000000515BI0100001119 27.85 Sqm
9 9 Cement concrete (1:2:4) with 12mm size h.g.b. chips including hoisting and laying etc. complete with curing as per direction of Engineer-in-charge BI01010001010000000000000515BI0100001120 0.552 Cum
10 10 12 mm thick cement plastering with cement mortar (1:6)over brick work with curing etc.complete.as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001121 38.08 Sqm
11 11 Filling F & P with excavated materials, earth, moorum including watering and ramming as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001122 311.89 Cum
12 12 Labour charges for conveyance of 160mm dia PVC pipes from stack yard to work site and Laying & fitting of the same as per direction of site Engineer in charge.\n\n BI01010001010000000000000515BI0100001123 402 Mtr
13 13 Cement Punning over Plastering with cost of cement including curing etc.complete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001124 20.85 Sqm
14 14 Cost of painting and lettering the detail salient features of project over the masanory sign board etc. complete as per direction of Engineer-in-Charge BI01010001010000000000000515BI0100001125 1 LIP
15 15 Cost of Installation lowering of Submerssible pump set, delivery fitting ,electrical installation & energisation & water trial etc.with Labour Charges for cutting, threading of G.I.Pipe, cost of cosumable materials such as Nut & Bolt , Rubber Insertion,white lead paint etc. including transportation charges of T&P materials like Chain Pully Block, Tripod pipes, Chain Tounge etc. complete as per direction of site Engineer in-charge. . BI01010001010000000000000515BI0100001126 2 No.
16 16 Providing ,fitting & fixing of M.S. shutter confirming to IS No.6248/7 of size (0.76x0.90) sq.mtr having 32mmx32mm angle iron framed chowkhat and shutter plate with 18SWG MS Sheet including all costs,taxes etc complete with priming & painting as per satisfaction of Engineer-in-Charge. BI01010001010000000000000515BI0100001127 63.84 Sqm
17 17 Labour charges for drilling of perfectly vertical bore of 200 mm dia T/W by hand boring set over the bed, rammed upto 450 mm dia in all type of soil from 0 to 30 mtrs.using bentonite drilling mud & labour charges for lowering of T/W assembly pipes including Well Plug & stanner pipe ,and gravel packing by the side of T/W casing etc. development of the T/W by the Air Compressor to yield sand free water complete. The cost include the cost of pilot bore and transportation of all materials i.e hand boring set. Diesel pump & accessories & digging of mud pit etc. but excluding the cost of casing pipes,,cone & gravel etc .as per direction of site Engineer in charge.\n BI01010001010000000000000515BI0100001128 41.4 mtr
18 18 Labour charges for slotting of 200mm dia PVC Pipe \n BI01010001010000000000000515BI0100001129 12 mtr
19 19 Cost of 200mm dia PVC blank pipe (sch-80) BI01010001010000000000000515BI0100001130 42 mtr
20 20 Cost of 200mm dia PVC cone \n BI01010001010000000000000515BI0100001131 2 No.
21 21 Cost of 200mm dia PVC threaded end cap.\n BI01010001010000000000000515BI0100001132 2 No.
22 22 Supplying all labour, tools and plant and packing the bore with washed gravel (size P-6) around the pipes in good quality including cost of gravel etc all complete as per the direction of the Engineer-in-charge. BI01010001010000000000000515BI0100001133 5.4 cum
23 23 5 H.P.Submmerssible Pump set ( BEE STAR Lebeled Energy efficient ) coupled with totally enclosed squirrel cage induction motor with delivery discharge 500 LPM at 25 mtrs. Head with cable, cable clip, support clamp etc. suitable for operation at 415+6% ,-15% volt,3 phase ,50 Hz, AC power supply with ISI mark and guarantee .\nThe materials of construction as given below.\n(a) Motor casing.. stainless steel AISI 304\n(b) Impeller ... bronze \n(c) Pump shaft... stainless steel\n(d) Sand guard...... bronze.\n(e) Non-return valve... CIFG 200. BI01010001010000000000000515BI0100001134 2 No.
24 24 Auto Star Delta Starter of sheet Steel enclosure suitable for operation of squirrel cage Induction Motor up to 15 HP with 20 MP ( AC/3) duly contactor at 415 Volt + 6% - 15% , 3 phase 50 Hz , A.C supply with Over Load Relay range 8.9 to13.5 Amp and No volt coil with electronic timer suitable for operation at voltage range of 300 -440 volt and to provide dependable protection during over load and single phasing as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001135 2 No.
25 25 Main Switch 63 Amp including fitting and fixing as per IS No.-4064(Part-I & II) with utilisation capacity category AC-22. BI01010001010000000000000515BI0100001136 2 No.
26 26 3 KVAR Capacitor as per ISI Standard specifications BI01010001010000000000000515BI0100001137 2 No.
27 27 3 Core x 10mm² Insulated ( HD ) armoured Electric Cable with Alluminium conductor for use in 3 phase power system of working voltage up to and including 1100 Volts at 50 Hz confirming to IS 1554 (Pt - 5 ) / 1988.with ISI mark & guarantee.as per direction of site Engineer in charge. BI01010001010000000000000515BI0100001138 30 Mtr.
28 28 3 Core X 2.5 Sqmm Submercible flat Cablefor use in 3 phase power system of working voltage up to and including 1100 Volts at 50 Hz confirming to IS 1554 (Pt - 5 ) / 1988.with ISI mark & guarantee.as per direction of site Engineer in charge. BI01010001010000000000000515BI0100001139 20 Mtr.
29 29 80mm dia nominal bore G.I.Pipe having wall thickness 4.5mm electrical resistance welded of medium class conforming to IS - 1239 (part-I/2004) with latest mendments, screwed at both ends as per IS -554 socketed at one end and the other end protected with plastic threaded protector. The socket conforming to IS:1239 (Part-II/1992) with latest Amendments in random length of 4 to 7 mtrs. Each pipe should bear ISI Certification and manufacturers name/trademark . BI01010001010000000000000515BI0100001140 48 Mtr.
30 30 80mm dia G.I.Bend confirming to IS No. 1239 (Pt-II/1992) BI01010001010000000000000515BI0100001141 6 No.
31 31 80mm dia G.I.Screw Boss Flange conforming to IS:No.6392/72 BI01010001010000000000000515BI0100001142 8 No.
32 32 80 mm dia GI Socket BI01010001010000000000000515BI0100001143 4 No.
33 33 100 x 80 mm dia GI Reducer Socket BI01010001010000000000000515BI0100001144 2 No.
34 34 Cost of 100 mm Ø G.I. nipple BI01010001010000000000000515BI0100001145 1 No.
35 35 80 mm dia M.S Clamp BI01010001010000000000000515BI0100001146 2 Pair
36 36 50 mm dia C.I. Air Release Valve (Single Action) confirming to IS 14845 (SI) with all assericies such as Shaddle,pipe etc. BI01010001010000000000000515BI0100001147 1 No.
37 37 200 mmx110 mm PVC Reducer BI01010001010000000000000515BI0100001148 1 No.
38 38 Supply of T& P sets( Hand Gloves,Ring Wrencth, DE Spanner,Sly wrencth etc) BI01010001010000000000000515BI0100001149 1 No.
39 39 Rigid UPVC pipe of 160 mm dia Ivory grey in colour having specific gravity of 1.4 to 1.46 Gm / CC of straight length of 6 M for portable water supplies confirming to IS 4985 / 2000 of BIS - Amendment - 2 Read with Table - I , of IS specification bearing ISI Mark for working presure of 2.5 Kgf/Cm2 as per latest amendment of ISI 4985 including cost of coupler for plain ended pipes or one end plain & other bell ended. The pipe should be tested by CIPET & each pipe should be clearly & indebile marked ink or Stenciled conforming to IS 4985/2000 including transportation and laying at site all complete. (The Rate inclusive of CIPET Testing Charges) BI01010001010000000000000515BI0100001150 402 Mtr.
40 40 160 mm dia PVC End Cap(6Kgf/Cm2) BI01010001010000000000000515BI0100001151 5 No.
41 41 160 mm dia PVC Equal Tee(6Kgf/Cm2) BI01010001010000000000000515BI0100001152 4 No.
42 42 150X150X100mm dia M.S outlet Tee made with 151mm ID and 166mm OD M.S Pipe of 8mm thick 400mm long fitted with 1 mtr long 100mm dia M.S.Pipe welded with 2 nos of 100mm dia M.S.Flange in between the 1 mtr M.S.Pipe and 0.25 mtr long 100 mm dia M.S.Pipe fitted horizentally with 2 mtrs of 100mm dia M.S.Elbow with water locking arrangement made out of 1 no. of 100mm dia open flange and 1 no. of 100mm dia blind flange and with hinges gaskets arrangement that UPVC pipe should be inserted directly 100mm long inside the151mm dia ID M.S.Pipe at the both ends painted with two coats of anti corosive paints in complete set. BI01010001010000000000000515BI0100001153 5 No.
43 43 Schedule B (Electrical Works) BI01010001010000000000000515BI0100001154
44 44 Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation with BIS Energy Level-II transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel (9.2 kg/mtr), Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle(4.5 kg/mtr),, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 6 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 25KVA S/S, G.I.pipe earthing with 25X5mm G.I.Flats including cost of 25 KVA 11/0.4 K.V Transformer , 35 Sqmm 3 ½ Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets etc., including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning. BI01010001010000000000000515BI0100001155 1 No.
45 45 Construction of 3 phase 11 KV line as per REC standard confirming to IE Rules 1956 with 300 kg 9Mtr long PSC Pole(IS: 1678-1998) with 55 mm² AAA Conductor , 11 KV "V" Cross arm (10.2 k.g. each), with required No.of 11 KV T & C Disc. Insulators 70KN in tension point & 11 KV Pin insulators, Couping & Padding of Poles. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc. with a cut point including cost of all materials, labour transportation,inspection & commissioning etc. complete. BI01010001010000000000000515BI0100001156 0.3 Km
46 46 Construction of 3 phase 4 wire Line using 8mtr long 200 kg PSC Poles with LT XLPE AB Cable of (3X50 mmSq.+ 1X35mm sq.) along with all required materials and concreting of stay/poles LT Dead end clamp, suspension clamp with I - hook, stay accessories such as Wire Insulators, clamp etc. to complete power supply as per the field condition (40m Span length). BI01010001010000000000000515BI0100001157 0.2 Km
47 47 Construction and erection of line DP with 400 Amp AB Switch= 1 no. confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors , G.I.pipe earthing with 25X5mm G.I.Flats including all costs couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning. BI01010001010000000000000515BI0100001158 1 No.
48 48 Construction of Boundary wall of (3.70mx 2.5 )Sq.mtr having total inside lenth of 11.20mtr around the sub station by providing 10no of 23cmx23cm pillars and rest walling with brick masonary having proper foundation as per the drawing including Sand filling and metal spreading inside the boundary , Fixing of MS grill gate of size 1.5mx1.5m with 35x35x6mm angles and 25x6mm flats etc. as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001159 1 No.
49 49 Earthing installation with required earthing materials like charcoal, common salt, conduit pipe, soft solder alcaps ,nuts & bolts, cable socket etc. including excavation of earth pits 2 Nos of size 1200mm X1200mm X 3000mm for fixing of earthing pipe 2 Nos of size 30mm dia X 3000 mm length with required slotting in pipes & fittings with 30 mm dia G.I.Flange etc. includidng excavation of earthing trench for laying of earthing G.I.Wire & filling the Trench Pits after fixing of pipes on completion on earthing work and pannel wiring with required 4mm2/2.5mm2 PVC coper wire including supply & transportation of materials to work site as per the direction of site Engineer in-charge. BI01010001010000000000000515BI0100001160 2 Set