Public Health Engineering Department-PHED has published Procurement Of Some Equipments Materials ( Including All Taxes ) For Central Water Testing Laboratory New Town Kolkata Water Treatment Plant Campus Division-I , P . H . E . Dte .. Submission Date for this Tender is 06-02-2021. Packaging Material Tenders in Action Area-I West Bengal. Bidders can get complete Tender details and download the document.
Name of Work:- Procurement of some equipments & materials (including all Taxes) for Central Water Testing Laboratory New Town Kolkata Water Treatment Plant Campus Division-I, P.H.E. Dte. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Ice Box Capacity-6Litres(Milton) \n | 1 | 1 | No. |
2 | 2 | Labolene neutral pH-5Litre \n | 2 | 1 | No. |
3 | 3 | Ammonia Buffer Solution (500 ml)(Merck/Thermofishers) \n | 3 | 5 | Nos. |
4 | 4 | Arsenic Test Kit, Method : colorimetric with test strips and reagent (contains Malonic acid),0.005-0.010-0.025-0.05-0.10-0.25-0.50 mg/L As (100 Test) (Merck) \n | 4 | 1 | No. |
5 | 5 | Reagent Bottle(1000ml) (White)(Borosil) | 5 | 1 | No. |
6 | 6 | Reagent Bottle(1000ml) ( Amber)(Borosil) | 6 | 1 | No. |
7 | 7 | Reagent Bottle(250ml) (White)(Borosil) \n | 7 | 2 | Nos. |
8 | 8 | Reagent Bottle(250ml) (Amber)(Borosil) | 8 | 2 | Nos. |
9 | 9 | Reagent Bottle(25ml) (White)(Borosil) \n | 9 | 2 | Nos. |
10 | 10 | Reagent Bottle(25ml) (Amber)(Borosil) | 10 | 2 | Nos. |
11 | 11 | Filter Paper No:42,125 mm ,Whatman | 11 | 4 | Nos. |
12 | 12 | Total Ionic Strength Buffer Solution-III (TISAB-III) (475 ml)(Thermo Scientific) \n | 12 | 2 | Nos. |
13 | 13 | Silver Nitrate, Analytical grade, (50 gm)(Merck) \n | 13 | 1 | No. |
14 | 14 | Silver Diethyl Dithio Carbmate, For Arsenic analysis ACS,Assay: 99% min,(10 gm)(Merck/Lovibond/VWR Chem) \n | 14 | 1 | No. |
15 | 15 | Chloroform,Analytical grade,Dry solvent,Water content: max 0.01%,(1000 ml)(Merck) \n | 15 | 2 | Nos. |
16 | 16 | Phenolphthalein Indicator Solution (Between pH 8.0-10.0) (125 ml)(Merck) | 16 | 1 | No. |
17 | 17 | Methyl Orange Indicator Solution (Between pH 2.8-4.6) (125 ml)(Thermo Scientific) | 17 | 1 | No. |
18 | 18 | Uv Safety Goggles | 18 | 1 | No. |
19 | 19 | Hydroxylamine Hydrochloride,Analytical grade, Specification : Assay-98%, pH value (5% water)-2.5-3.5, Acidity -0.25meg/g, (500 mg)(Merck) \n | 19 | 2 | Nos. |
20 | 20 | 1-10 Phananthroline, monohydrate, (100 gm)(Merck) | 20 | 1 | No. |
21 | 21 | Potassium Chromate, Analytical grade,Assay-min 99.5%,pH of 5% Soln-9.02-9.8 (500 gm)(Merck) \n | 21 | 1 | No. |
22 | 22 | Potassium Iodide, Analytical Grade,Assay- min 99.8%, (200 gm)(Merck) \n | 22 | 2 | Nos. |
23 | 23 | Stannous Chloride Dihydrate, Analytical grade,Solubility: 10% soln in Dilute HCl should be clear & Assay : min 99% (200gm)(Merck) | 23 | 1 | No. |
24 | 24 | Morpholine ACS,(500 ml)(Merck) | 24 | 1 | No. |
25 | 25 | Sodium Thiosulphate Pentahydrate (500 gm)(Fisher Scientific) \n | 25 | 1 | No. |
26 | 26 | Erichrome Black-T (50 gm)(Merck) \n | 26 | 1 | No. |
27 | 27 | Filter paper NO; 542(GE health LifeScience) \n | 27 | 2 | Nos. |
28 | 28 | Hydrochloric Acid 35%( 500ml)(Merck) \n | 28 | 4 | Nos. |
29 | 29 | Ammonium Acetate(500 g)(Merck) \n | 29 | 1 | No |
30 | 30 | Sodium Acetate(500 g)(Merck)(Merk) \n | 30 | 2 | Nos. |
31 | 31 | HPLC Water (1 lit) \n | 31 | 2 | Nos. |
32 | 32 | Potassium Chromate(Merck) | 32 | 1 | No |
33 | 33 | Sulphuric Acid (Merck) | 33 | 2 | Nos. |
34 | 34 | Lead Acetate(Merck) | 34 | 1 | No |
35 | 35 | Zinc metal(Merck) \n | 35 | 1 | No |
36 | 36 | Acetone(Merck) \n | 36 | 4 | Nos. |
37 | 37 | Sodium Thiosulphate(Merck) \n | 37 | 1 | No |
38 | 38 | Acetic Acid Glacial,500g(Merck) \n | 38 | 3 | Nos. |
39 | 39 | EDTA-disodium salt,100g(Merck) | 39 | 2 | Nos. |
40 | 40 | Manganese (Mn) Test Kit:( Method- Photometric)(0.010- 10 mg/L)(50 Tests )(Merck) \n | 40 | 1 | No |
41 | 41 | Iron (Fe) Test Kit (Method:Photometric contains:Thioglycolic acid,Ammonium thioglycolate.(0.05 -5.00mg/L)(250Testts ) (Merck) \n | 41 | 1 | No |
42 | 42 | Lead (pb) Test Kit (Photometric Method)(0.010-5.00mg/L Pb)( 50 Tests)(Merck) | 42 | 1 | No |
43 | 43 | Cadmium(Cd) Test Kit(photometric method)(0.002-0.500 mg/L)(50 Tests )(Merck) \n | 43 | 1 | No |
44 | 44 | Chromium (Cr) Test Kit (Photometric method)(0.010-3.00 mg/L)(50 Tests )(Merck) \n | 44 | 1 | No |
45 | 45 | Copper (Cu) Test kit ( Photometric method)(0.02-6.00mg/L) ( 50 Tests)(Merck) \n | 45 | 1 | No |
46 | 46 | Tissu Paper \n | 46 | 20 | Rolls |
47 | 47 | Digital thermometer with sensor for Refrigerator \n | 47 | 3 | Nos. |
48 | 48 | Silica Test Kit for water Sample \n | 48 | 1 | No |
49 | 49 | Electrode for pH meter Model No. pH 700 (UTECH INSTRUMENT) \n | 49 | 1 | No |
50 | 50 | 50 ml Volumetric Flask with Certificate \n | 50 | 1 | pc |
51 | 51 | 5ml Volumetric Flask with Certificate \n | 51 | 1 | pc |
52 | 52 | 50 ml Measuring Cylinder with Certificate | 52 | 1 | pc |
53 | 53 | 100 ml Measuring Cylinder with Certificate \n | 53 | 1 | pc |
54 | 54 | 250 ml Measuring Cylinder with Certificate | 54 | 1 | pc |
55 | 55 | Conductivity Standard Solution (1413 us/cm @ 25° C)(NIST Traceable)- Thermo Scientific (480ml)/ Reagecon | 55 | 2 | pc |
56 | 56 | Xylenol Orange Indicator(125ml)-(Sigma Aldrich/Merck/Fisher Scientific) \n | 56 | 1 | pc |
57 | 57 | Zinc Sulfate (500 grm) - (Plus pharma/RPI) \n | 57 | 1 | pc |
58 | 58 | 1000 NTU Non Ratio turbidity Standard (NIST Traceable)- Reagecon (100 ml)/ Merck Fisher Scientific \n | 58 | 2 | pc |
59 | 59 | Aluminium Foil | 59 | 60 | Nos. |
60 | 60 | Petri dish with Triple vented Radiation Sterile(460062) 60x15mm pack of 250Nos (High Media) \n | 60 | 10 | Boxes |
61 | 61 | Chromocult Agar (500g) for Microbiolog (High Media) \n | 61 | 1 | No. |
62 | 62 | Iso-Propyl alcohol, Analytical grade,(500 ml) (Merck) \n | 62 | 4 | Nos. |
63 | 63 | Calcium carbonate volumetric standard, secondary reference material for complexometry, traceable to NIST SRM (80 gm) (Merck) | 63 | 1 | No. |
64 | 64 | Iron standard solution traceable to NIST SRM 1000 mg/l Fe, (500 ml)(Merck) | 64 | 1 | No. |
65 | 65 | Arsenic standard solution traceable to SRM from NIST 1000 mg/l As (500ml)(Merck) | 65 | 1 | No. |
66 | 66 | OEM of Turbidity Meter(WTW) \n | 66 | 2 | Nos. |
67 | 67 | Absorbant Pads(sterile)(100 Nos )(Axiva) \n | 67 | 20 | Boxes |
68 | 68 | Sterile Membrane Filter paper(0.45µ)(100 Nos )(Highmedia) \n | 68 | 15 | Boxes |
69 | 69 | Sterile container for Microbiology(100ml) (Himedia) \n | 69 | 1500 | Nos. |
70 | 70 | pH Buffers - 25°C : pH: 2.00 ±0.02@25°C,NIST traceable(Inorganic Venture) \n | 70 | 1 | No |
71 | 71 | pH Buffers - 25°C : pH: 4.00 ±0.02@25°C,NIST traceable(Inorganic Venture \n | 71 | 1 | No |
72 | 72 | pH Buffers - 25°C :, pH: 7.00 ±0.01@25°C,NIST traceable(Inorganic Venture \n | 72 | 1 | No |
73 | 73 | pH Buffers - 25°C , pH: 10.00 ±0.01@25°C,NIST traceable(Inorganic Venture \n | 73 | 1 | No |
74 | 74 | Ethanol Alcohol 95% (High Media) \n | 74 | 4 | Nos. |
75 | 75 | Sodium chloride volumetric standard, secondary reference material for argentometry, traceable to NIST standard reference material. (80 gm)(Merck) | 75 | 1 | No. |
76 | 76 | Fluoride standard solution 1000 mg/l F¯, NIST Traceable- Certified (500 ml)(Merck) \n | 76 | 2 | Nos. |
77 | 77 | Cupric Sulphate(100g)(Merck) \n | 77 | 1 | No. |