Construction Of Rcc 3 ( Three ) Storied Fire Station Building , Under Ground Reservoir ( 1 . 00 Lakh Ltr . Capacity ) , Boundary Wall And Security Fencing With Heavy Duty Iron Gate Etc . At Salbari In Baska Dist, Salbari in Baska Dist-Assam

Department Of Fire Services has published Construction Of Rcc 3 ( Three ) Storied Fire Station Building , Under Ground Reservoir ( 1 . 00 Lakh Ltr . Capacity ) , Boundary Wall And Security Fencing With Heavy Duty Iron Gate Etc . At Salbari In Baska Dist. Submission Date for this Tender is 11-02-2021. Building Work Tenders in Salbari in Baska Dist Assam. Bidders can get complete Tender details and download the document.




Tender Notice

26741934
Corrigendum : Construction Of Rcc 3 ( Three ) Storied Fire Station Building , Under Ground Reservoir ( 1 . 00 Lakh Ltr . Capacity ) , Boundary Wall And Security Fencing With Heavy Duty Iron Gate Etc . At Salbari In Baska Dist
Open Tender
Indian
Assam
Salbari in Baska Dist
11-02-2021

Tender Details

Construction Of Rcc 3 ( Three ) Storied Fire Station Building , Under Ground Reservoir ( 1 . 00 Lakh Ltr . Capacity ) , Boundary Wall And Security Fencing With Heavy Duty Iron Gate Etc . At Salbari In Baska Dist

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Feb-2021 Corrigendum1 Other 10-02-2021
2 10-Feb-2021 Corrigendum2 Date 11-02-2021

Key Value

Document Fees
INR 2000 /-
EMD
INR 385385.0 /-
Tender Value
INR 1.92 Crore /-

BOQ Items

Name of Work:Construction of RCC 3(Three) storied Fire station Building , Under Ground Reservoir (1.00 lakh ltr.Capacity) Boundary Wall and Security Fencing with Heavy Duty Iron Gate etc. at Salbari in Baksa District.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Construction of Main Building (Civil Works) a1
2 1.01 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\nI) Upto a depth of 2.00 m below the existing ground level\na) In ordinary soil a2 367.53 m3
3 1.02 (B)Extra over item no.1.1(A) above for each 1.00 m depth or part thereof beyond the initial depth of 2.00 m a3 150.55 m3
4 1.03 Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered)\n(a) Upto a depth of 1.5 metre a4 439.74 m3
5 1.04 (b) Above 1.5m up to 3.00m a5 379.12 m3
6 1.05 Providing brick soling in foundation and under floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete\n(a) Brick on flat soling. a6 747.96 m2
7 1.06 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop. 1:3: 6 (1 cement : 3 coarse sand : 6 coarse aggregate by volume (using mixture machine) a7 40.38 m3
8 1.07 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.00 m and removal of the same for in-situ reinforced concrete and plain concrete work in:\n(3.1.1.1) Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(ii) Using 25mm thick plank a8 47.08 m2
9 1.08 (3.1.1.2) Sides of tie beams, grade beams etc. at or below ground level\n(ii) Using 25mm thick plank a9 405.2 m2
10 1.09 (3.1.1.3) Columns, pillars, posts and strut\nSquare, rectangular, polygonal in plan or any shape like Tee / L etc. having plane vertical face\n(ii) Using 25mm thick plank a10 481.34 m2
11 1.1 (3.1.1.4) Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties\n(a) For depth not exceeding 1.00 m\n(ii) Using 25mm thick plank a11 495.18 m2
12 1.11 (3.1.1.5) Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like\n(a) Floors etc. upto 200 mm in thickness\n(ii) Using 25mm thick plank a12 916.41 m2
13 1.12 F/F & above a13 334.13 m2
14 1.13 S/F & above a14 77.94 m2
15 1.14 (3.1.1.10) Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38 mm thick plank) a15 51.17 m2
16 1.15 Providing and laying plain / reinforced cement croncrete works cement with coarse sand and 20 mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately).\n(I)Using mixture machine\nA) In sub structure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\n(a) M20 or Proportion 1:1.5:3 a16 121.84 m3
17 1.16 (B) In super-structure from plinth level upto 1st floor level.\n(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\n(a) M20or Proportion 1:1.5:3 a17 241.67 m3
18 1.17 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(b) In proportion 1:4 a18 51.89 m3
19 1.18 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding MS rod / Tor steel of column to be embeded in cement mortar and will be measured and paid separately). 112 mm thick Brick wall\nIn cement mortar in proportion 1:4 (1 cement : 4 sand) a19 812.83 m2
20 1.19 Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed\nIn superstructure above plinth level upto 1st Level\n(b) In proportion 1:4 (1 cement : 4 sand) a20 11.9 m3
21 1.2 Providing and laying 25 mm thick damp proof course with cement concrete in proportion 1:1.5:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. a21 14.33 m2
22 1.21 Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, headand steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed togather by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be field up with 1:4:8 P.C.C. After fitting the frame with brick/concreteworks etc. complete as directed by the department for all levels.\n(b) 1.6mm thick sheet\n(iii) size125mmx60mm (single rebate) a22 142.05 RM
23 1.22 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered plywood face panels conforming to relevent IS code including oxidised iron butt hinges (100 mm x 75 mm x 3.5 mm) 6 nos. with necessary wood screws.\n(b) Non decorative type and block board core\n(i) 40 mm thick a23 40.99 m2
24 1.23 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. \n(b)3 Track sliding window\n(i)6mm clear glass a24 95.41 m2
25 1.24 (a)2 Track sliding window\n(ii) 5 mm frosted glass a25 11.34 m2
26 1.25 Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. \na) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998 a26 21.98 Qntl
27 1.26 Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement\nv) 0.60 mm thick a27 201.68 m2
28 1.27 Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete.\nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement\n(iv) 0.60 mm thick a28 37.5 Rm
29 1.28 Earth / sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c )With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. a29 429.58 m3
30 1.29 Supplying, fitting and fixing in position reinforcement bars conforming to relevant IS code for RCC work / RB walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level).\na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) a30 340.62 Qntl
31 1.3 c) ISI approved MS rod a31 5.09 Qntl
32 1.31 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nB) On fair side (backing coat 10 mm and finishing coat 10mm thick) b) In cement mortar 1:4 a32 1658.37 m2
33 1.32 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed.\nA) On rough side (backing coat 15 mm and finishing coat 5mm thick)\nb) In cement mortar 1:4 a33 435.24 m2
34 1.33 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete / mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5 mm).\ni) Thickness = 1.50 mm thick a34 2093.49 m2
35 1.34 (a) Applying one coat of cement primer of approved brand and manufacture on wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth a35 1543.81 m2
36 1.35 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint / Berger paint / ICI paint / J&N paint / Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) a36 1543.81 m2
37 1.36 Extra over item no 13.4.1 above for every suibsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (asian paint/Berger paint /ICI paint/J&N paint /Nerolac) \n(i).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac a37 1543.81 m2
38 1.37 (b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials a38 435.24 m2
39 1.38 Finishing old / new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish of Sandex Matt brand of Snowcem India Ltd. of required shade after clering and clearing the surfaces etc. including scaffolding complete as directed at all levels (two coats). a39 435.24 m2
40 1.39 Applying primary coat over new steel and other metal surface over 100 m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\n(a) With ready mixed "red-lead/ red oxide" primer. a40 194.18 m2
41 1.4 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian Paint / Berger Paint / ICI Paint / J&N Paint / Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i) Surfaces over 100 mm in width or girth\n(b) High gloss (Asian paint / Berger paint / ICI paint / J & N paint / Nerolac) a41 194.18 m2
42 1.41 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\na) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make\nii) Of size 600mmx600mm and above a42 358.96 m2
43 1.42 Providing ANTISKID tiles of approved quality size ,shape not less than 8 mm on floor skiting over a cement mortar bed 15 mm thick of 1:3(1cement:3 coarse sand ) of approved make fix with fix with fix-A-tile (chocksey/sika/pedilite /rouf /white cement complete at all level as specified and directed \n(A) CERAMIC\n i)Normal range (Sizes 300 mm x 300mm and above\n (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate a43 105.7 m2
44 1.43 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).\na) Normal range \nSomany/ Orient/Nitco/Asian Make\nii) Of size 200mmx300mm and above a44 94.32 m2
45 1.44 Providing, fitting and fixing MS grill of requiredpattern for windows / clerestory windows / opening with MS flats at required spacing in frame all round, square or round MS bars with round headed bolts and nuts or screws.\n(ii) Ornamental grill\n(c ) Fixed to Brick work / PCC / RCC a45 5572.13 kg
46 1.45 Pre construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\n(a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. a46 270.83 m2
47 1.46 Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the Department up to a depth of 300 mm making rod holes along the line @ 150 mm apart to a depth of 300 mm and applying emulsion @ 4.50 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\n(a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. a47 95.24 m2
48 1.47 Pre construction anti-termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450 mm and width 300 mm (when required refill in 200 mm thick layers) applying the emulsion @ 5 (five) litres per sqm towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\n(a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. a48 34.56 m2
49 1.48 Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in proportion 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey / Sika / Pedelite / Rouf) / white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).\n (i) Normal Quality\n(i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) a49 3.61 m2
50 1.49 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt and satin finished).\n(e) Butt hinge (ii) 75mm x 45mm x 3.20 a50 54 Nos
51 1.5 (a) Sliding Tower bolts (i) 300mm x 16mm a51 54 Nos
52 1.51 (b)Tower bolts (i) 300mm x 12mm a52 54 Nos
53 1.52 (ic)Door handle (iii) 150mmm a53 54 Nos
54 1.53 SIDE DRAIN a54
55 1.54 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(i) Upto a depth of 2.00 m below the existing ground level\n(a) In ordinary soil a55 140.77 m3
56 1.55 Providing brick soling in foundation and under floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a) Brick on flat soling a56 239.27 m2
57 1.56 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately)\n(a) In prop. 1:3: 6 (1 cement : 3 coarse sand : 6 coarse aggregate by volume (using mixture machine) . a57 20.46 m3
58 1.57 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed in super-structure above plinth level up to 1st floor level. \n(b) In proportion 1:4 a58 34.16 m3
59 1.58 15 mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed.A) On rough side\n(a) In cement mortar 1:4 a59 195.21 m2
60 1.59 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nB) On fair side (backing coat 10 mm and finishing coat 10mm thick) b) In cement mortar 1:4 a60 245.94 m2
61 1.6 Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantityetc. complete as directed and specified, including forest royality within a distance of 8.00 km (Forest royality shall be reimbrushed on production of necessary certificate from the forest authority duly countersigned by DFO concerned).\n(b) Other than Guwahati city a61 2523.09 m3
62 1.61 Construction of RCC pavement specification and design as directed by concern department………… a62 277 m2
63 1.62 Constuction of RCC approach road specification and design as directed by concern department……… a63 25 RM
64 1.63 Construction of Boundary Wall a64 247.2 RM
65 1.64 Construction of Heavy Duty Iron Gate a65 1 Nos
66 2 SANITARY WORKS a66
67 2.01 Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make a) White (i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover) a67 7 Nos
68 2.02 Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (ii) Deluxe Single Flush (Cat. No. C8091/C8057) a68 7 Nos
69 2.03 Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\n PEDESTAL BASIN (with pedestal)(A) Parryware Make (a) White (v) Cascade NXT 550 x 440 with short Pedestal and spring set (Cat. No.C0404/C0379/C8298) a69 8 Nos
70 2.04 Providing fitting and fixing stainless steel kitchen sink with drain board of Nirali (Regular Range) make with coupling and strainer of same make, CI brackets, PVC waste pipe including painting of fittings, cutting and making good the walls wherever required.(B) Nirali\n(vii) Super Deluxe Big (Bowl Size - 410 x 410 x 190) Glossy a70 1 Nos
71 2.05 Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.(B) Hindware Make\n(a) White\n(v) Half Stall Olympus (Cat. No.60006) a71 8 Nos
72 2.06 Supplying, fitting and fixing PVC pipes of 6.00 kg / cm² (Supreme / Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below G/L as directed and specified.\n(A) In exposed surfaces or in trenches\n(I) 160 mm diametre a72 25 RM
73 2.07 (A) In exposed surfaces or in trenches\n(II) 110 mm diametre a73 140 RM
74 2.08 (IV) 75 mm diametre a74 90.75 RM
75 2.09 Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc.as necessary complete at all levels including below G/L as directed and specified.\n(A) In exposed surfaces or in trenches\n(II) 110 mm diametre a75 6 Nos
76 2.1 Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc.as necessary complete at all levels including below G/L as directed and specified.\n(A) In exposed surfaces or in trenches\n(III) 110 mm diametre a76 17 Nos
77 2.11 (IV) 75 mm diametre a77 30 Nos
78 2.12 Supplying fiting and fixing PVC plain single tee of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G/L as directed and specified.\n(A) In exposed surfaces or in trenches\n(III) 110 mm diametre a78 11 Nos
79 2.13 (IV) 75 mm diametre a79 16 Nos
80 2.14 Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats / charcoal covered with earth over a layer of AC plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table). a80 4.41 m3
81 2.15 Providing fitting and fixing 75 mm dia. PVC cowel of ISI make complete as directed and specified. a81 2 Nos
82 2.16 Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. a82 2 Nos
83 2.17 Construction of a septic tank and soak pit (As per detailed estimate) a83 1 Nos
84 2.18 Providing fitting and fixing decorative mirror complete as directed and specified.\n(A) Parryware Make\n(b) Size 600mm x 450mm a84 8 Nos
85 2.19 Providing, fitting and fixing soap dish of Parryware Make complete as specified and directed.\n(ii) Wall Soap tray (Cat. No.C9951) a85 16 Nos
86 2.2 Providing, fitting and fixing chrome plated (CP) towel rail of Agmeco make complete as specified and directed.\n(c) Parryware make (cat.No.C9948)\n(d) Agmeco Made\n(i) Cubin 600mm long (Cat. No.CB-00202) a86 8 Nos
87 2.21 Providing, fitting and fixing chrome plated (CP) towel ring of Jaquar make complete as specified and directed.\n(a) Jaquar make \n(ii) Continental Accessories a87 7 Nos
88 3 WATER SUPPLY WORKS a88
89 3.01 Supplying fitting and fixing GI pipes of following sizes, with all necessary 'R' brand or similar approved GI fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, HW clamps etc. complete at all levels including below G/L as directed and specified.\n(I) Exposed or in trenches\n(a) 50 mm diametre\n(i) Using Tata (Medium) a89 20 RM
90 3.02 (b) 40 mm diametre\n(i) Using Tata (Medium) a90 25 RM
91 3.03 (d) 25 mm diametre\n(i) Using Tata (Medium) a91 65.43 RM
92 3.04 (II) Concelled\n(f) 15 mm diametre\n(i) Using Tata (Medium) a92 69.91 RM
93 3.05 Supplying fitting and fixing CP bib cock 15 mm dia. of approved brand directed and specified. (GI and CP pipes will be measured separately).\n(II) Jaguar make\n(b)Continental\n(ii) Bib cock long thread a93 22 Nos
94 3.06 Supplying fitting and fixing chrome plated (CP) stop-cock of approved brand and size as mentioned below as directed and specified. (GI and CP pipes will be measured and paid separately).\n(II) Jaguar make\n(a)Continental / Clarion\n(iv) 15 mm diametre (Angular stop cock with long thread)\n a94 19 Nos
95 3.07 Supplying and fitting fixing CP pillar cock of 15 mm diametre of approved brand as specified and directed.\n(II) Jaguar make\n(b) Long neck with areator a95 7 Nos
96 3.08 Supplying fitting and fixing Chrome Plated (CP) sink cock of approved brand as directed and specified. (GI and CP pipes will be measured and paid separately). \n(V) Jaquar brand\n(a) Continental / Clarion\n(ii) Sink cock with raised 'J' shaped swinging spout a96 1 Nos
97 3.09 Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately)\n(iii) Jaquar brand\n(a) Continental \n(ii) Shadow arm 190 mm long heavy coated body with wall flanges\n a97 7 Nos
98 3.1 Supplying fitting and placing plastic cylindrical vretical claused topd(PCVC)tank of sintex make .over the stagging with manhole cover with looking and cleanine arrangement including providing pads size as required for inlet and out let pipes \n(i) 2000Lt capacity a98 4 Nos
99 3.11 Taurus make FRP composite stuructural vessel Iron removal filters of 100% rust proof vessels complete with Top& Bottom Stairners, Multiport Valves ,Quality filter media -e.g Treated Sand, Mno2, Barakar Sand Gravels & Pebbles.ISO NSF certified \n(i) 4000Lt capacity a99 2 Nos
100 4 Construction of under Ground Water Reservoir a100
101 4.01 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(I)Upto a depth of 2.00 m below the existing ground level\n(a)In ordinary soil a101 106.58 m3
102 4.02 (B)Extra over item no.1.1(A) above for each 1.00 m depth or part thereof beyond the initial depth of 2.00 m a102 40.83 m3
103 4.03 Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered)\n(A)Upto a depth of 1.50 m a103 79.94 m3
104 4.04 Providing brick soling in foundation and under floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a)Brick on flat soling a104 59.45 m2
105 4.05 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a)In prop. 1:3: 6 (1 cement : 3 coarse sand : 6 coarse aggregate by volume (using mixture machine) a105 5.871 m3
106 4.06 Supplying, fitting and fixing in position reinforcement bars conforming to relevant IS code for RCC work / RB walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level).\n(b)ISI approved super ductile TMT Ba\n(ii)Other ISI marked a106 41.34 Qntl
107 4.07 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.00 m and removal of the same for in-situ reinforced concrete and plain concrete work in:\n(3.1.1.1) Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(ii)Using 25mm thick plank a107 9.28 m2
108 4.08 (3.1.1.2) Sides of tie beams, grade beams etc. at or below ground level\n(ii)Using 25mm thick plank a108 13.35 m2
109 4.09 (3.1.1.3) Columns, pillars, posts and strut\n(a)Square, rectangular, polygonal in plan or any shape like Tee / L etc. \n(ii)Using 25mm thick plank a109 21.68 m2
110 4.1 (3.1.1.4) Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties\n(a)For depth not exceeding 1.00 m\n(ii)Using 25mm thick plank a110 20.11 m2
111 4.11 (3.1.1.5) Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like\n(a)Floors etc. upto 200 mm in thickness\n(ii)Using 25mm thick plank a111 30.91 m2
112 4.12 (3.1.1.8) Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like. a112 122.76 m2
113 4.13 Providing and laying plain / reinforced cement concrete work in proportion 1:1:2 including dewatering if necessary and curing complete but, excluding cost of form work and plain / reinforcement for RCC.\n(i)In sub structure upto plinth level a113 9.13 m3
114 4.14 (ii)In super structure from plinth level\n(a)Wall (thickness not less than 10 mm) including attached piller, tee, butress, plinth and string course etc.b) M20 grade concrete or Prop. 1:1.5:3 a114 17.76 m3
115 4.15 15 mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed.\n(b)In cement mortar 1:4 a115 94.49 m2
116 4.16 20 mm thick cement plaster in two coats, backing coat 10 mm and finishing coat 10 mm thick on fair side of brick / stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles,not exceeding 80 mm girth and finished even and smooth including curing complete as directed.\n(a)In cement mortar 1:3 a116 151.22 m2
117 4.17 Extra for providing and mixing Integral waterproofing liquid admixture & plasticiser Conplast X421 IC of Fosroc Chemicals @ 100 ml per bag of cement in concrete for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. as specified and directed by the Department complete at all levels.\nA In concrete proportion:\n(iii)In 1:1:2 (1 cement : 1 coarse sand : 2 aggregate) or M-25 grade a117 26.89 m2
118 4.18 Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub-structure up to plinth level.\n(b)In proportion 1:4 a118 1.323 m3
119 4.19 15 mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed.\n(a)In cement mortar 1:3 a119 6.43 m2
120 5 Deep tube well a120
121 5.01 Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. vi) Bore hole of 200mm diameter a121 200 Rm
122 5.02 Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. II PVC PIPE SUPREME vii) 160mm diameter a122 200 Rm
123 5.03 Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.\nB) PVC PIPE iv) 50mm diameter a123 90 Rm
124 5.04 Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt.\n Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 3 HP STAGE 7 to 40 with MCB controlled Submersible motor pump set control panel. a124 1 Nos
125 6 Internal Electrical a125
126 6.01 Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. \n (a)Short point up to 3.00 metre. length. a126 11 point
127 6.02 (b)Medium point upto 6.00 m length a127 64 point
128 6.03 (c ) Long point upto 10.00 m length a128 23 point
129 6.04 Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.\n (b) Medium point up to 6.00 metre. Length. a129 16 point
130 6.05 Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, with 2 way 5/ 6 amp F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) . \n Long point up to 10.00 metre. Length. a130 3 point
131 6.06 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete..\n(c ) Long point upto 10.00 m length a131 7 Nos
132 6.07 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\n(With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. a132 325 RM
133 6.08 With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. a133 95 RM
134 6.09 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface with flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.\nWith 3 x 6 sq. mm. + earth continuity with2x 4 sq. mm. cable in flat 25 mm ISI marked casing 'n' capping system. a134 40 RM
135 6.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 4.00 Sq.mm 2 Core armoured U.G. cable a135 40 RM
136 6.11 Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp a136 76 each
137 6.12 Supplying and fitting of 15/18 watt LED lamp in the existing bracket holder as specified and directed by the Department. a137 76 each
138 6.13 Supplying with fitting & fixing of the following Street light luminaries complete with lamp in the existing pole including making necessary connection as approved by the Deptt.)with 2 ×1.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable as specified and directed by the department.\nPhilips make) Type TRC033 2xTL-D36W IC For lamp 2xTL-D36W/TL-40W./ Wipro make) : WSF 15240 For lamp 2x36/40W FTL (T8) / Crompton Greaves make) SFE1624HSBN For lamp 2x36/40W FTL / Havells make): LHRF 14204011 For lamp 2x36/40W FTL a138 6 each
139 6.14 Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . a139 1 each
140 6.15 Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt . a140 1 each
141 6.16 Supplying & laying of 8 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. a141 10 RM
142 6.17 Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt. a142 2 each
143 6.18 Supply, fitting & fixing 20 mmx3 mm Copper strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of Brass Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode copper strips and Lightning Arrestor etc. as specified and directed by the deptt. a143 42 each
144 6.19 Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1400 mm Sweep. (ORIENT PSPO make) /Premium model 1400 mm Sweep SS-390 Deco. Havells make) a144 19 each
145 6.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Trans Air 300 mm sweep (Crompton make) a145 5 each
146 6.21 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \n 4 way TPN (4+12) double door a146 5 each
147 6.22 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \n(b) 8 way SPN double door a147 2 each
148 6.23 Supplying with fitting and fixing single pole 10 KA 240/415 V, 50 Hz MCB of the following capacity complete with necessary connection as specified and directed by the Department.\n6A a148 25 each
149 6.24 C series 32 A a149 2 each
150 6.25 C series 40 A a150 2 each
151 6.26 Supplying including fitting and fixing bus bar chamber ( HPL/ GECO / or equivalent make) with 4 strips bus bar of length 350/450/600/900 mm made of aluminium alloy or wrought aluminium suitable for 100 amp capacity complete with all accessories including connection etc. as required complete a151 1 each
152 6.27 Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider, legrand, L&T make)\n63A a152 1 each
153 6.28 Supplying including installation, connection as approved by the Deptt.)with 2x2.5 sq mm copper FR cable, testing and commissioning of following post top lantern/ WALL LIGHT on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt.\nSPC101/ HPC 101/102/104/106/110/111/ 112, 1X HPLN-125W E, Philips make) . or equivalent (Equivalent will be selected by the deptt considering the mother items rate) WIPRO/ JAQUAR make.\n a153 3 each
154 6.29 Supplying and installation and commising of out door type sub station complete with transformer LT line with all fittings etc . a154 1 unit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail