Supply Of Various Equipments To Electrical And Electronics Dept And Mechanical Dept Supply Of Synchronous Motor And Various Items To Eee And Me Lab, Kottayam-Kerala

Rajiv Gandhi Institute of Technology has published Supply Of Various Equipments To Electrical And Electronics Dept And Mechanical Dept Supply Of Synchronous Motor And Various Items To Eee And Me Lab. Submission Date for this Tender is 02-03-2021. Greases Tenders in Kottayam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26737425
Supply Of Various Equipments To Electrical And Electronics Dept And Mechanical Dept Supply Of Synchronous Motor And Various Items To Eee And Me Lab
Open Tender
Indian
Kerala
Kottayam
02-03-2021

Tender Details

Supply Of Various Equipments To Electrical And Electronics Dept And Mechanical Dept Supply Of Synchronous Motor And Various Items To Eee And Me Lab , Item With Detailed Specification , Permanent Magnet Synchronous Motor- High Speed Permanent Magnet Synchronous Motor For Electric Vehicle ApplicationPower = 6 KwSpeed = High Speed For Electric Vehicle Application ( 4000-12000 Rpm ) Torque = High Torque ( 4 . 7 - 14 . 5 Nm ) With Inbuilt Speed Encoder , Torque Transducer ( Band Width 50 Khz ) And Loading Mechanism , High Temperature And High Thermally Conductive Paste - *Material - Silicone Grease *Continuous Temperature -200Oc ( 392Of ) *Cure - Not Required *Adheres To Most Wets Most Surfaces *Thermal Conductivity ( K ) ( Btu ) ( In ) / ( Hr ) ( Ft^2 ) ( Of ) - Extremely High 16 *Electrical Insultation Very High 10^14 , He-Ne Laser ( Mw ) - Power ( Mw ) : 2 Mw Wavelength ( Nm ) : 543 . 5 1/E2 Beam Diameter ( Mm ) : 0 . 79 Beam Divergence ( Mrad ) : 0 . 88 Mode Polarization : Tem00linear , Ultrasonicator/Ultrasonic Probe - Sample Volume : 0 . 1 - 1000 Ml Power : 200 W Frequency : 24 Khz Amplitude : 20-100% Pulse : 0-100% Power Supply : 230V/60 Hz Set Weight : 2 . 3 Kg . , High Accuracy Liquid Calibration Bath - *Highly Stable Standard Stirred Liquid Bath For Calibrating : Rtds/Thermocouples And Other Temperature Sensors *Temperature Controlled By A Self Tuned Pid Controller *The Medium Used In The Bath : Silicon Oil *Temperature Range : 50 Deg C To 250 Deg C . *Heat Up Time : 50 Deg C To 250 Deg C - 31 Min . *Cool Down Time : 250 Deg C To 50 Deg C - 150 Min . , Digital Thermal Wire Anemometer With Telescopic Probe - The Hot Wire Anemometer Is A Device Used For Measuring The Velocity And Direction Of The Fluid Multi Channel Cta , Air Velocity Range : 0 . 10 - 25 . 0 M/S Air Velocity Resolution : 0 . 01 M/S Air Velocity Accuracy : ( 5% + 0 . 1 M/S ) Dimensions : 198 X 78 X 51 Mm .

Key Value

Document Fees
INR 2803 /-
EMD
INR 12300.0 /-
Tender Value
INR 12.30 Lakhs /-

BOQ Items

Name of Work: Supply of Synchronous Motor and various equipment to Electrical and Electronocs Engg and Mechanical Engg Departments of Rajiv Gandhi Institute of Technology, Kottayam
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Item with detailed specification
2 1.01 Permanent Magnet Synchronous Motor- High Speed Permanent Magnet Synchronous Motor for Electric Vehicle Application\nPower = 6 KW\nSpeed = High Speed for Electric vehicle application (4000-12000 RPM)\nTorque = High Torque (4.7 - 14.5 Nm)\nWith inbuilt Speed encoder, Torque Transducer(band width 50 KHZ) and Loading Mechanism item1 1 Nos
3 1.02 High Temperature and High Thermally Conductive Paste - *Material - Silicone grease *Continuous Temperature -200oC (392oF) *Cure - Not required *Adheres to Most Wets most surfaces *Thermal conductivity (k) (BTU) (in)/(hr) (ft^2) (oF) - Extremely high 16 *Electrical Insultation Very high 10^14 \n item2 8 Nos
4 1.03 He-Ne Laser (mW) - Power (mW) : 2 mw Wavelength (nm) : 543.5 \n 1/e2 Beam Diameter(mm) : 0.79 \n Beam Divergence (mrad) : 0.88 \n Mode Polarization : TEM00Linear item3 1 Nos
5 1.04 Ultrasonicator/Ultrasonic probe - Sample volume : 0.1 - 1000 ml \nPower : 200 W Frequency : 24 kHz Amplitude : 20-100% Pulse : 0-100% Power Supply : 230V/60 Hz Set Weight : 2.3 Kg. item4 1 Nos
6 1.05 High Accuracy Liquid Calibration Bath - *Highly stable standard stirred liquid bath for calibrating : RTDs/Thermocouples and other temperature sensors *Temperature controlled by a self tuned PID controller *The medium used in the bath : Silicon oil *Temperature Range : 50 Deg C to 250 Deg C. *Heat up time : 50 Deg C to 250 Deg C - 31 min. *Cool down time : 250 Deg C to 50 Deg C - 150 min. item5 1 Nos
7 1.06 Digital Thermal Wire Anemometer with telescopic probe - The Hot Wire Anemometer is a device used for measuring the velocity and direction of the fluid Multi Channel CTA, Air Velocity Range : 0.10 - 25.0 M/s Air Velocity Resolution : 0.01 m/s Air Velocity Accuracy : (5% + 0.1 m/s) Dimensions : 198 x 78 x 51 mm. item6 1 Nos