Provision Of Semi Underground Sump Along With Allied Works Services In Mes Tinali Residence Mes Complex At Dinjan Mil Stn Under Ge Dinjan, DINJAN-Assam

Military Engineer Services-MES has published Provision Of Semi Underground Sump Along With Allied Works Services In Mes Tinali Residence Mes Complex At Dinjan Mil Stn Under Ge Dinjan. Submission Date for this Tender is 22-02-2021. Sump Tenders in DINJAN Assam. Bidders can get complete Tender details and download the document.




Tender Notice

26736525
Corrigendum : Provision Of Semi Underground Sump Along With Allied Works Services In Mes Tinali Residence Mes Complex At Dinjan Mil Stn Under Ge Dinjan
Open Tender
Indian
Assam
DINJAN
22-02-2021

Tender Details

Provision Of Semi Underground Sump Along With Allied Works Services In Mes Tinali Residence Mes Complex At Dinjan Mil Stn Under Ge Dinjan

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-02-2021
2 17-Feb-2021 83039AmendmentI Date 22-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 28400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVN OF SEMI UNDERGROUND SUMP ALONG WITH ALLIED WORKS SERVICES IN MES TENALI RESIDENCE MES COMPLEX AT DINJAN MIL STN UNDER GE DINJAN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
2 2 SCH A PART I (BUILDING/STRUCTURES)
3 3 Construction of RCC UG Sump 15000 Galon capacity with all fitting and fixture complete all as spesified and as per drawing No TD/SZ/372 dated 27 Sep 1988 W0001C 1 Lump-sum
4 4 SCH A PART II (MISC WORK)
5 5 Supply, install, testing and commissioning of 5 HP/3.7 KW three phase centrigugal monoblock pump set 16 mtr head complete all as specified and directed by Engr-in-charge. 18513A 1 Each
6 6 Supplying, installing, testing and commissioning horizontal monoblock pump single stage, suction and delivery size 80 mm X 65 mm, discharge 17.9 litres per second at 28 m head, 10 HP capacity suitable for working voltage 415 volts, 3 phase as per Kirloskar model No. KDS 1040+ including fully automatic star delta starter as per catalogue No. SS94362 of L&T including all necessary electric connection from starter to pump including 3 core multi stranded copper conductor of size 4 sqmm of 10 running metre with lugs complete all as specified and as directed. 60005A 2 Each
7 7 Supply , installation, commissioning and testing in repair of outdoor type, LT panel board of size 1000 mm X 600 mm X 500 mm metre, CPRI approved factory made, powder coated suitable for 3 phase 4 wire 415 V, 50 Hz and provided with suitable 'U' type gasket to make it dust/vermin proof & general construction confirming to IS: 8623/93, floor block mounting type made out of 2 mm thick CRCA sheet with using 45 mm X 45 mm X 5 mm angle iron frame, factory fabricated duly compartmentalized for each control gear with front & back openable, lockable / operable by keys from both sides louvers & air vent gasket for natural flow of air and to accommodate incoming/ outgoing MCCBs and TPN aluminium bus bar 400 Amp and alike complete including fixing of undermentioned MCBs and alike as under:-\n (i) Incoming: -\n(a) MCCB, 63 Amps, 4 pole, 35 kA, 415 Volts- 01 No\n(b) Ammeter size 96 mm X 96 mm, flush mounted digital type, three phase of class 1.0 including selector switch and CT- 01 No.\n(c) LED Indicator lamp RYB- 01 No\n(d) Voltmeter size 96 mm X 96 mm, flush mounted digital type, three phase, class 1.0 including selector switch and CT- 01 No.\n(ii) out going: -\n(a) MCCB, 40 Amps, 3 pole, 25 KA, 415 Volts-06 Nos\n(b) Timer switch 8/16 Amps 250 V- 01 Nos\n(c) Contactor ML-2, 230 Volts, AC Supply\n(Note: The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.) 19604I 1 Each
8 8 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. 19473A 2 Each
9 9 M & L for 3- layer PP-R (Polypropylene random copolymer) pipes 110 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random laid in trenches/floor at places where directed complete all as specified and directed. 18073J 35 Running Metre
10 10 M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 150 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed. 27034B 1 Each
11 11 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 19244C 35 Running Metre
12 12 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 19241D 30 Running Metre
13 13 M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed. 27034C 2 Each
14 14 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 03006A 25 Cum
15 15 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 03009A 16 Cum
16 16 Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point 03029A 9 Cum
17 17 M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed. 03029A 470 Each
18 18 Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly. 03029A 6 Cum
19 19 M & L for construction of new valve chamber of size 900 mm X 900 mm X 900 mm including necessary earth work in any type of soil, PPC foundation (1:3:6) type C-2 40 mm grade stone aggregate as in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40 mm X 40 mm X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide prime on all metal works & three coats of white wash on all plastered surfaces of valve chambers complete all as specified & directed by Engineer-in-Charge. 03029A 2 Each
Disclaimer :