Delhi Development Authority-DDA has published M/O Project Office Manglapuri . M/O Ei Dg Sets At Dda Office Complex Manglapuri --Armo Of 160 Kva Dg Set , Pump Set , Internal Electrical Installation And Compound Lighting Along With Repairing And Servicing Of Air Conditioner , Desert Cooler , Fan. Submission Date for this Tender is 01-02-2021. CCTV System Tenders in EE(E)/ELD-10/DDA Delhi. Bidders can get complete Tender details and download the document.
Name of Work: M/o project office Manglapuri. SH: M/o EI & DG sets at DDA office complex Manglapuri --ARMO of 160 KVA DG set ,pump set, Internal electrical installation and compound lighting along with Repairing and servicing of Air Conditioner, Desert cooler ,Fans and S/I/T/C of CCTV System. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Operation & Maintenance of DG set ,pump set,desert cooler ,air conditioner along with IEI control Panel & compound lighting as per inventory terms and condition attached. | BI01010001010000000000000515BI0100001112 | 12 | Per Month |
2 | 2 | Supplying and fixing following Modular type switch/socket on the existing Modular plate & switch box including connections but excluding Modular plate etc. as required. a)5/6 A Switch | BI01010001010000000000000515BI0100001113 | 65 | Each |
3 | 2.01 | b)5/6 A Socket outlet | BI01010001010000000000000515BI0100001114 | 65 | Each |
4 | 2.02 | c) 15/16 A Switch | BI01010001010000000000000515BI0100001115 | 55 | Each |
5 | 2.03 | d) 15/16 A socket outlet | BI01010001010000000000000515BI0100001116 | 55 | Each |
6 | 3 | Supplying and fixing following Piano type switch/socket on the existing Modular plate & switch box including connections but excluding Modular plate etc. as required. a)5/6 A Switch | BI01010001010000000000000515BI0100001117 | 85 | Each |
7 | 3.01 | b)5/6 A Socket outlet | BI01010001010000000000000515BI0100001118 | 85 | Each |
8 | 3.02 | c) 15/16 A Switch | BI01010001010000000000000515BI0100001121 | 75 | Each |
9 | 3.03 | d) 15/16 A socket outlet | BI01010001010000000000000515BI0100001122 | 75 | Each |
10 | 4 | Supplying and replacement 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole & Neutral | BI01010001010000000000000515BI0100001123 | 70 | Each |
11 | 4.01 | (c) Three Pole & Neutral | BI01010001010000000000000515BI0100001124 | 2 | Each |
12 | 5 | Providing and fixing of the standard make offload changeover switch (side handle ) with following rating suitable for 415 V ,3-phase,50 Hz AC supply i/c dismantling the existing burnt change over with same rating i/c connection,testing and commissioning etc. complete as required. a) 100 A | BI01010001010000000000000515BI0100001120 | 1 | set |
13 | 5.01 | b) 200 A | BI01010001010000000000000515BI0100001121 | 3 | set |
14 | 6 | Supply and replacement of following accessories i/c testing etc complete as required. a) 40 A SPN MCB,16 KA, C curve | BI01010001010000000000000515BI0100001122 | 10 | Each |
15 | 6.01 | b) 40 A TPN MCB,16 KA, C curve | BI01010001010000000000000515BI0100001123 | 10 | Each |
16 | 6.02 | c) 63 A SPN MCB,16 KA, C curve | BI01010001010000000000000515BI0100001124 | 8 | Each |
17 | 6.03 | d) 100A FP MCCB,30 kA, C curve | BI01010001010000000000000515BI0100001125 | 1 | Each |
18 | 6.04 | e) 63 A TPN MCCB,16 KA, C curve | BI01010001010000000000000515BI0100001126 | 5 | Each |
19 | 6.05 | f)call bell/buzzer ,single phase | BI01010001010000000000000515BI0100001127 | 20 | Each |
20 | 6.06 | g)bell push, piano type | BI01010001010000000000000515BI0100001112 | 20 | Each |
21 | 6.07 | h)Stepped type electronic fan regulator | BI01010001010000000000000515BI0100001113 | 25 | Each |
22 | 6.08 | i)20 watt 4 ft light LED batten Complete fitting. | BI01010001010000000000000515BI0100001114 | 150 | Each |
23 | 6.09 | j)20 Watt 4 ft light LED Rod | BI01010001010000000000000515BI0100001115 | 90 | Each |
24 | 6.1 | h)PVC batten 40 mm | BI01010001010000000000000515BI0100001116 | 90 | Mtr |
25 | 7 | Supplying and drawing following sizes of FRLS PVC insulated\ncopper conductor, single core cable in the existing surface/\nrecessed steel/ PVC conduit as required:- a) 3 x 1.5 sq. mm | BI01010001010000000000000515BI0100001117 | 360 | Mtr |
26 | 7.01 | b) 3 x 2.5 sq. mm | BI01010001010000000000000515BI0100001118 | 270 | Mtr |
27 | 7.02 | b) 3 x 4 sq. mm | BI01010001010000000000000515BI0100001119 | 180 | Mtr |
28 | 8 | supplying and fixing of following size of steel conduit along with accessories in surface /recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required. a) 25mm | BI01010001010000000000000515BI0100001120 | 50 | Mtr |
29 | 9 | Repairing & rewinding of 3 HP submersible pump set (Three phase) of Kirloskar make i/c painting, connection, testing etc. complete as reqd:- \nRewinding of motor \nGun Metal bearing bush \nRotor sleeve turning, grinding, etc.\nThrust Plate \nWater seal \nGun Metal Neck Ring \nE P Impeller \nE P Bowl/ Diffuser \nDOL Bush DOL sleeve\n | BI01010001010000000000000515BI0100001121 | 1 | Each |
30 | 10 | Repairing & rewinding of 5 HP Sewage submersible pump set (Three phase) of Kirloskar make i/c painting, connection, testing etc. complete as reqd:-\nRewinding of motor \nRadial ball bearing upper & lower side \nMechanical seal upper & lower side\n"O' ring set \nLubricant oil\n\n | BI01010001010000000000000515BI0100001122 | 1 | Each |
31 | 11 | Dismantling the existing damaged /burn out ceiling fan of 1200 mm sweep and rewinding the same with copper winding and replacement of ball bearing etc. and fixing the ceiling fan i/c connection, testing complete as required | BI01010001010000000000000515BI0100001123 | 45 | Each |
32 | 12 | Dismantling the existing damaged /burn out wall fan of 400 mm sweep and rewinding the same with copper winding and replacement of ball bearing etc. and fixing the ceiling fan i/c connection, testing complete as required | BI01010001010000000000000515BI0100001124 | 25 | Each |
33 | 13 | Lifting of submersible pump sets along with G.I. pipes and accessories the existing borewall i/c dismantling of pump set from delivery line etc. complete as reqd. | BI01010001010000000000000515BI0100001125 | 1 | Each |
34 | 14 | Lowering of submersible pump set in the existing bore with G.I. pipes i/c replacement of existing nuts & bolts, connections of delivery line, valves cable jointing, testing etc. completed as reqd. | BI01010001010000000000000515BI0100001126 | 1 | Each |
35 | 15 | Supplying of following sizes of XLPE insulated of 1.1 KV Grade Al. cond. armoured power cable including connection, testing etc. as required.\na) 2C x16 sq. mm. | BI01010001010000000000000515BI0100001127 | 90 | Mtr |
36 | 16 | Supplying & Replacement of LED Flood light fitting (IP 65 protection) of 70 W complete in all respect i/c making connections , earthing the same and to meet the requirement as per technical specifications etc. as required. | BI01010001010000000000000515BI0100001128 | 6 | Each |
37 | 17 | Supplying, Installation, Testing and Commissioning of high effiveincy 2x2 ft recess/Ceiling flat panel with high brightness 34/36W LED for glare free homogenous illumination i/c making connections with existing PVC insulated copper conductor single core cable, earthing the same and to meet the requirement as per technical specifications etc. as required. | BI01010001010000000000000515BI0100001129 | 15 | Each |
38 | 18 | Servicing of window/ split type air conditioners of 1.5 ton/2 ton capacity i/c cleaning with chemical of condenser coil, evaporation coil, lubricating & washing of complete A.C. with front grill and Replacement of air filter Pads, re-installation of air conditioner in the position testing etc. as required. | BI01010001010000000000000515BI0100001130 | 21 | Each |
39 | 19 | Servicing of water cooler 100/ 120 ltrs. Capacity oiling of fan, cleaning of Base plate with chemical and cleaning of water tank, and painting etc. complete as required. | BI01010001010000000000000515BI0100001131 | 4 | Each |
40 | 20 | Supplying and replacement of burnt compressor of the following items i/c gas charging, testing of pressure and commissioning etc. as required. A)1.5 ton /2 ton window/ split air conditioners | BI01010001010000000000000515BI0100001132 | 8 | Each |
41 | 20.01 | b) 100/ 120 ltrs water coolers | BI01010001010000000000000515BI0100001133 | 2 | Each |
42 | 21 | Supplying and replacement of following parts of water coolers/ air conditioners i/c connection, testing etc. as required. a) Running capacitor 36 mfd | BI01010001010000000000000515BI0100001134 | 5 | Each |
43 | 21.01 | b) Running capacitor 15 mfd | BI01010001010000000000000515BI0100001135 | 10 | Each |
44 | 21.02 | c) Starting capacitor 80/100 mfd | BI01010001010000000000000515BI0100001136 | 10 | Each |
45 | 21.03 | d) Overload Protectector/overload relay | BI01010001010000000000000515BI0100001137 | 10 | Each |
46 | 21.04 | e) Thermostate | BI01010001010000000000000515BI0100001138 | 8 | Each |
47 | 21.05 | f) Front grill | BI01010001010000000000000515BI0100001139 | 8 | Each |
48 | 21.06 | g) Air filter pads | BI01010001010000000000000515BI0100001140 | 12 | Each |
49 | 21.07 | h) PCB repair | BI01010001010000000000000515BI0100001141 | 10 | Each |
50 | 22 | Supplying & replacement of fan motor i/c connection testing complete as required. a) Window type air conditioner 1.5 ton | BI01010001010000000000000515BI0100001142 | 9 | Each |
51 | 22.01 | b) Split type air conditioner 2 ton | BI01010001010000000000000515BI0100001143 | 4 | Each |
52 | 22.02 | c) 100/ 120 ltrs water coolers | BI01010001010000000000000515BI0100001144 | 2 | Each |
53 | 23 | Supplying and Replacement with regulator cooler kit (motor) suitable for 18"/20" size desert cooler i/c dismantling of existing desert cooler kit (motor), connection, testing etc. | BI01010001010000000000000515BI0100001145 | 40 | Each |
54 | 24 | Supplying and Replacement of desert cooler body of size for 18"/20" cooler fan. Upper cover, Lower tank and support should be made of 18 SWG GI sheet, Parde should be made of 20 SWG GI sheet and depth of tank should be minimum 7", with switches complete etc. as required. | BI01010001010000000000000515BI0100001146 | 5 | Each |
55 | 25 | Supplying and fixing of wood wool pad set (set of 3 pieces) with steel wire jali, suitable for 18"/20" desert cooler i/c disposing the existing pad, cleaning of water tank compete etc. as reqd. | BI01010001010000000000000515BI0100001147 | 90 | Each |
56 | 26 | Cleaning, denting and painting of following Items i/c supplying of cleaning materials, checking of nuts, bolts & safety pins/keys making them good in proper condition , numbering, testing etc. as reqd. a) Desert Cooler | BI01010001010000000000000515BI0100001148 | 90 | Each |
57 | 26.01 | b) Cooler Stand | BI01010001010000000000000515BI0100001149 | 90 | Each |
58 | 27 | Supplying and Replacement of Submersible pump set suitable for 18”/20” desert cooler i/c dismantling, refixing, connection, testing etc complete as required. | BI01010001010000000000000515BI0100001150 | 70 | Each |
59 | 28 | Supply, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. | BI01010001010000000000000515BI0100001151 | 12 | Each |
60 | 29 | Supply, fixing and replacement of wall fan 400 mm sweep i/c connection, testing etc. complete as reqd. | BI01010001010000000000000515BI0100001152 | 10 | Each |
61 | 30 | Supplying and fixing of 450 mm sweep size exhaust fan with complete in all respec with louvers suitable for single phase 230 volt,50 Hz AC supply i/c connection, testing etc. complete as reqd. | BI01010001010000000000000515BI0100001153 | 5 | Each |
62 | 31 | Supplying and fixing of following capacity of capacitor in the existing desert cooler/fans i/c connection, testing etc complete as reqd. a) 4 MFD | BI01010001010000000000000515BI0100001154 | 25 | Each |
63 | 31.01 | b) 3.15 MFD | BI01010001010000000000000515BI0100001155 | 45 | Each |
64 | 32 | Supplying and Replacement of suitable plastic air blade in the existing 18”/20” desert cooler i/c dismantling, refixing, connection, testing etc complete as required. | BI01010001010000000000000515BI0100001156 | 30 | Each |
65 | 33 | Supplying and Replacement of three core copper 1.5 sq.mm wire in the existing 18”/20” desert cooler i/c dismantling, refixing, connection, testing etc complete as required. | BI01010001010000000000000515BI0100001157 | 140 | Mtr |
66 | 34 | Supplying and Fixing the 3 Pin top in the existing desert cooler wire i/c connection, testing etc. complete as reqd. | BI01010001010000000000000515BI0100001158 | 60 | Each |
67 | 35 | Supply and replacement of existing starter of booster pump sets with motor starter(MK-I,DOL) i/c dismantling, refixing, connection, testing etc complete as required. | BI01010001010000000000000515BI0100001159 | 1 | Each |
68 | 36 | Servicing of 160 KVA DG set i/c supply & replacement of following parts i/c connection & testing etc.complete as reqd. \ni) B check Kit - 1 set ii) Air Element …..1 Set \niii) Engine Oil ---30 ltrs iv)Radiator Descaling----- 1 Job | BI01010001010000000000000515BI0100001160 | 1 | Job |
69 | 37 | SITC of 2 MP (In door/Out Door IP Camera)n IP LED NIGHT VISION with 3.6 or 6mm LENS, 1080P Resolution, Coverage up to 20 Metrs. | BI01010001010000000000000515BI0100001161 | 8 | Each |
70 | 38 | Supply, Installation, Testing and Commissiong of Video networked Recoder for 08 IP Camera inputs which shall support up to 5 MP recording resolution , min.12 TB inuilt capability to accommodate surveillance grade SATA hard Disk Drives, multipule resolution recording options, shall have BNC, HDMI & VGA outputs, The unit shall have 10/100/1000 MBPS self-adaptive Ethernet interface through RJ-45 Port. The NVR shall have, USB interface, RS-232 interface & RTS-485 interface. | BI01010001010000000000000515BI0100001162 | 1 | No. |
71 | 39 | Supply, Installation, Testing and Commissiong of 4 Pair category 6 cable consisting of 24 AWG solid copper conductors and as per the specification. | BI01010001010000000000000515BI0100001163 | 300 | Mtr. |
72 | 40 | Suppling and fixing of 09 U rack of CRCA power coated MS sheet material 1mm thickness, approxX1.00 m length with glass front door with locking arragement , 5 NO. of 5 pin A/C sockets, cooling fans, lighting arragement etc complete as required. | BI01010001010000000000000515BI0100001165 | 1 | No. |
73 | 41 | Supply,Installation,testing and commissioning of 08 Port Net Work Switch | BI01010001010000000000000515BI0100001166 | 1 | No. |
74 | 42 | SITC of SMPS 12 Volt 10 AMP . | BI01010001010000000000000515BI0100001166 | 1 | No. |
75 | 43 | SITC of 02 TB HDD for 10-15 Days Recoding . | BI01010001010000000000000515BI0100001167 | 1 | No. |
76 | 44 | Supply, Installation, testing & commissioning of LED Monitor with 350 NITS Brightness (Monitors Size: 19 Inches) | BI01010001010000000000000515BI0100001168 | 1 | No. |
77 | 45 | Supply and drawing of following pair of 0.5mm dia FRLS PVC insulated annealed copper conductor un armoured telephone cable in the existing surface/recessed steel /PV conduit as reqired. 1. 2 Pair (DSR2018_1.18.2) | BI01010001010000000000000515BI0100001164 | 250 | Mtr. |
78 | 46 | Supplying and fixing of following 25 mm sizes of medium Class PVC Conduit along with accossories in surface/recess including cuttng the wall and making good the same in case of recessed conduit as required. (DSR) | BI01010001010000000000000515BI0100001165 | 200 | Mtr. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy