Public Health Engineering Department-PHED has published Supply Erection Testing Commissioning 250 Kva Transformerand 200 Kva Dg Set And Construction Of Dg Platform Shed For Dg Set Elec Mech . Instr . Work Required From Transformer And Dg Set To Ht Lt Room Of Mps And Stp For Running And O And M 12 Months. Submission Date for this Tender is 01-02-2021. Diesel Generators Tenders in Karnal Haryana. Bidders can get complete Tender details and download the document.
Name of Work: Supplying, Erection, testing and commissioning of 250KVA Transformer, 200KVA DG set, construction of Transformer & DG set platform, Shed For DG Set, Electrical, Mechanical, instrumentation work required from Transformer and DG set to HT/LT panel room of MPS & STP for proper running/functioning of MPS/STP complete in all respect and all other works contingent thereto at 2.0MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor technology including Operation & Maintenance for 12months during defect liability period after trial run of 3months and 10years thereafter in Village KACHHWA, Distt. Karnal (HARYANA). Amount - 30.90 Lacs | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply, Erection, Testing & Commissioning of 1 NO. copper wound ester oil filled Transformer of 250KVA on load tap changer or suitable capacity on higher side (at 2 MLD STP in village Kachhwa), with servo stabilizer of standard make outdoor type, VCB Panel, G.O. Switch, H.T. Metering Panels, APFC Panels along with for each Transformer, 11KV Substation, entire cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel, Earthing, safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer including Operation & Maintenance during 1year of defect liability period after 3 months of satisfactory trial run and 10 years thereafter | Item 1 | 1 | Complete job |
2 | 2 | Supply, Erection, Testing & Commissioning of 1 Nos. Silent DG Set of 200 KVA or suitable capacity on higher side (at STP) capacity each with Acoustic Canopy, AMF Panel and Copper Earthing of suitable rate with change over switch & synchronizing panel (CPCB norms compliance), Shed for DG set and any other contingent thereto complete in all respect as per DNIT including Operation & Maintenance during 1year of defect liability period after 3 months of satisfactory trial run and 10 years thereafter. | Item 2 | 1 | complete job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail