Repair Replacement Of Unserviceable Loft Tanks Pvc Water Storage Tank Of Various Capacity Cleaning And Allied Works At Old Navy Nagar Under Ge Nw Navy Nagar Colaba Mumbai, GE (NW) Navy Nagar, Colaba, Mumbai-Maharashtra

Military Engineer Services-MES has published Repair Replacement Of Unserviceable Loft Tanks Pvc Water Storage Tank Of Various Capacity Cleaning And Allied Works At Old Navy Nagar Under Ge Nw Navy Nagar Colaba Mumbai. Submission Date for this Tender is 22-02-2021. Water Tank Tenders in GE (NW) Navy Nagar, Colaba, Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

26710312
Corrigendum : Repair Replacement Of Unserviceable Loft Tanks Pvc Water Storage Tank Of Various Capacity Cleaning And Allied Works At Old Navy Nagar Under Ge Nw Navy Nagar Colaba Mumbai
National Competitive Bid
Indian
Maharashtra
GE (NW) Navy Nagar, Colaba, Mumbai
22-02-2021

Tender Details

Repair Replacement Of Unserviceable Loft Tanks Pvc Water Storage Tank Of Various Capacity Cleaning And Allied Works At Old Navy Nagar Under Ge Nw Navy Nagar Colaba Mumbai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Feb-2021 Other corrigendum Other 15-02-2021
2 15-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR/ REPLACEMENT OF UNSERVICEABLE LOFT TANKS, PVC WATER STORAGE TANK OF VARIOUS CAPACITY, CLEANING AND ALLIED WORKS AT OLD NAVY NAGAR UNDER GE (NW) NAVY NAGAR, COLABA, MUMBAI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Cleaning of underground sump of any capacity cleaning the floors, wall and ceiling portion of sump etc by Mechnical high pressure spray and steel wire brush to remove Algae/dirt/foreign dirt completely and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land distance exc 5 kms & n.exc 10 kms and applying spray of approved chemical etc. complete all as specified and as directed by Engineer-in-charge . Note :- Rates deemed to be included for pumping out water left below foot valve.\nNote: Rate include the painting of two coats of enamal paint with visible colour about date of cleaning and due date for cleaning complete all as specified.
2 1.01 Sump capacity of approximately 9,20,000 liters 4 Each
3 1.02 Sump capacity of approximately 16,00,000 liters 1 Each
4 1.03 Sump capacity of approximately 14,00,000 liters 2 Each
5 1.04 Sump capacity of approximately 4,50,000 Liters 2 Each
6 1.05 Sump capacity of approximately 3,20,000 Liters 2 Each
7 1.06 Sump capacity of approximately 2,00,000 Liters 2 Each
8 1.07 Sump capacity of approximately 2,50,000 Liters 1 Each
9 1.08 Sump capacity of approximately 1,50,000 Liters 2 Each
10 2 Cleaning of PVC and RCC water storage tank in low and high rising buildings(G+14) by mechanical high pressure spray and remove all foreign matter completly and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land and complete all as specified and as directed by Engineer-in-charge . \nNote: Rate include the painting of two coats of enamal paint with visible colour about date of cleaning and due date for cleaning complete all as specified.
11 2.01 OH Tank of capacity 5000 Litres 260 Each
12 2.02 OH Tank of capacity 3000 Litres 70 Each
13 2.03 OH Tank of capacity 10000 Litres 50 Each
14 3 Cleaning the vegetation including grass, bushes small trees and all vegetation growth complete including uprooting of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris to a distance n.exc.50m complete all as specified and directed. 3000 Sqm
15 4 S&F in repairs FRP lid cover for PVC water storage tank complete accessory for closing and locking arrangement suitable for various capacitys as approved by BMC
16 4.01 For capacity of 5000 litres 200 Each
17 4.02 For capacity of 3000 litres 150 Each
18 5 Demolition of cement concrete(unreniforced) and removing debries away from MD land all as specfied. 20 Cum
19 6 M&L cement concrete 1:2:4 ,type B-2 (using 40mm graded stone aggregate) of 15cm of height of foundation for supporting PVC tank all as specfied and directed. 20 Cum
20 7 Supply and fix in repairs CP stop cock, brass, screwed down with crutch or butterfly handle suitable for GI or PVC tubing 15 mm dia bore including necessary clamp & saddles all as specified . 500 Each
21 8 Supply and fix in repairs long body CP bib cock brass with crutch or butterfly handle screwed both ends for GI or pvc tubing 15 mm dia bore including necessary clamp & saddles etc all as specified. 1000 Each
22 9 Supply and fix in repairs long body CP bib cock with aerator screwed both ends for GI or pvc tubing 15 mm dia bore including necessary clamp & saddles etc all as specified. 500 Each
23 10 Supply/Fixing in repair/replacement of internal steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge. \nNOTE:Clamping of above line with suitable size of stainless steel saddles at 2 meter apart and work should be done in shaft of high rise building(G+14) and quoted rate should be include necessary Scaffolding and clamping materials\n
24 10.01 40 mm bore 250 RM
25 10.02 50mm bore 300 RM
26 10.03 80mm bore 220 RM
27 11 Supply/Fixing in repair/replacement of internal steel water tubing with CPVC pipes SDR 11 & PlainCPVC SDR 11 fittings in wall and shafts including necessary saddling and and work to be done in high rise building up to 15 th floor short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.supply\n
28 11.01 20 mm nominal outside dia 1500 RM
29 11.02 25mm nominal outside dia 1000 RM
30 12 S&F stainless steel mosquito net(corrision resistance ) for Air vent pipes on various OHT and sumps completley all as directed. 5 Sqm
31 13 Supply & Fixing in repairs Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250) including one coat of red oxide primer and two coats of synthetic enamel paint. \nNote:Contractor should survey each quarter in old and new navy nagar and highly rusted angle should be change accordingly. 4000 Kg
32 14 M& L for Cleaning of loft tanks of capacity 170 to 275 ltrs in existing position by mechanised pressure, cleaning using PVC tank cleaning solution and draining out the water by wet vaccum pump, rinsing with clean drinking water and providing sticker showing the date of cleaning complete all as specified.\nNote : Any damage to pipe and PVC tank during cleaning shall be made good by the contractor at his own cost. 3000 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail