Comprehensive Br Maintenance And Repair Of Otm Md Accn And Internal Electric Supply Connected Work At Ebs Babugarh Under Age Br Ii And Age Em I Of Ge North Meerut Cantt, Meerut-Uttar Pradesh

Military Engineer Services-MES has published Comprehensive Br Maintenance And Repair Of Otm Md Accn And Internal Electric Supply Connected Work At Ebs Babugarh Under Age Br Ii And Age Em I Of Ge North Meerut Cantt. Submission Date for this Tender is 20-02-2021. Electrification Work Tenders in Meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26699093
Corrigendum : Comprehensive Br Maintenance And Repair Of Otm Md Accn And Internal Electric Supply Connected Work At Ebs Babugarh Under Age Br Ii And Age Em I Of Ge North Meerut Cantt
Open Tender
Indian
Uttar Pradesh
Meerut
20-02-2021

Tender Details

Comprehensive Br Maintenance And Repair Of Otm Md Accn And Internal Electric Supply Connected Work At Ebs Babugarh Under Age Br Ii And Age Em I Of Ge North Meerut Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 49960.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : COMPREHENSIVE B/R MAINTENANCE AND REPAIR OF OTM / MD ACCN AND INTERNAL ELECTRIC SUPPLY & CONNECTED WORK AT EBS BABUGARH UNDER AGE B/R-II AND AGE E/M-I OF GE (NORTH) MEERUT CANTT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M& L for providing Cement concrete 1:5:10 Type E 2 (using 40 mm graded crushed stone aggregate ,in foundations, filling and mass concrete complete all as specified and directed. BI01010001010000000000000515BI0100001112 3 Cum
2 2 M&L for providing cement concrete 1:2:4 Type B 1 (using 20 mm graded crushed stone aggregates) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs hold fast water troughs, filling in pressed steel door frame and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed. BI01010001010000000000000515BI0100001113 1 Cum
3 3 M&L for providing precast RCC 1:2:4 type B-1 using 20mm graded stone aggrigate) as in manhole cover, cover slab, chullah hoods, chajjas, water troughs, shelves or similar works set & jointed in CM 1:4 complete all as specified and directed. BI01010001010000000000000515BI0100001114 2 Cum
4 4 M &L for Brickwork with fly ash bricks old size bricks straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed.\n BI01010001010000000000000515BI0100001115 5 Cum
5 5 All as per Srl item No 04 here-in-before but except bricks BI01010001010000000000000515BI0100001116 2 Cum
6 6 S&F factory made glazed, gauzed and skeleton shutters 35 mm thick 2nd class hardwood (SAL/ CHAMP / HOLLOCK) open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); for doors and fitted to chowkats complete all as specified and directed. BI01010001010000000000000515BI0100001117 20 Sqm
7 7 S&F plain, framed, panelled shutters (any number of panels), of 2nd class Hardwood (HOLLOCK / CHAMP / SAL) 35mm thick with panels of timber flaton both sides (feather edges), or of veneered particle board medium density, wood particle board with commercial face veneers; and fitted to chowkats complete all as specified and directed. BI01010001010000000000000515BI0100001118 20 Sqm
8 8 S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood facepanels, commercial type on both sides, complete all as specified and directed. BI01010001010000000000000515BI0100001119 10 Sqm
9 9 Taking down chowkats or frames with shutters (without taking off shutter and builders hard ware fittings from frames) not exc. 1.5 sqm each, complete all as specified and directed.\nNote :- Rate also incuding in this item for necessary cutting down / taking out hold fasts from the existing concrete / brick work and making good the disturbed surfaces with match existing surfaces. BI01010001010000000000000515BI0100001120 5 Each
10 10 All as per Srl item No 09 here-in-before exc 1.5 sqm but n.exc 4.00 Sqm BI01010001010000000000000515BI0100001121 20 Each
11 11 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame at site as per specification & drawing on srl page No 156 of SSR Part-II complete all as specified and directed. BI01010001010000000000000515BI0100001122 20 Sqm
12 12 S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing shown on page 160 of SSR Part-II complete all as specified and directed. BI01010001010000000000000515BI0100001123 50 RM
13 13 S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame with 5mm PVC fillet as per specifications and drawing shown on page No 162 of SSR Part-II and as directed. BI01010001010000000000000515BI0100001124 230 Sqm
14 14 S&F 200mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt having shoot / dia of bolt not less than 10mm complete all as specified and directed. BI01010001010000000000000515BI0100001125 50 Each
15 15 S&F 250 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed. BI01010001010000000000000515BI0100001126 25 Each
16 16 S&F stainless steel butt hinges of 100 mm size, complete all as specified and directed. BI01010001010000000000000515BI0100001127 39 Each
17 17 S&F butt hinges of 100 mm size, Medium weight, cold rolled mild steel. complete all as specified and directed. BI01010001010000000000000515BI0100001128 75 Each
18 18 S&F Butt hinges of 100 mm size, Medium weight, cold rolled mild steel and fixed, complete all as specified and directed. BI01010001010000000000000515BI0100001129 100 Each
19 19 S&F 125mm size Mild steel pressed handles, oval type, stove enamelled black, complete all as specified and directed. BI01010001010000000000000515BI0100001130 50 Each
20 20 S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples including necessary beadings complete all as specified and directed. BI01010001010000000000000515BI0100001131 18 Sqm
21 21 S&F in repairs galvanised mild steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples including necessary beadings complete all as specified and directed. BI01010001010000000000000515BI0100001132 60 Sqm
22 22 S&F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to Fe-290 (Gde E-165) complete all as specified and directed. BI01010001010000000000000515BI0100001133 150 Kg
23 23 Applying two coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm each coat including cleaning surfaces complete all as specified and directed. BI01010001010000000000000515BI0100001134 60 Sqm
24 24 M&L for bitumastic gola, with 80/25 bitumenand coarse sand mixture 1:3 by weight 8cm x 8cm at the junction of roofing to vertical surfaces specified and directed BI01010001010000000000000515BI0100001135 50 RM
25 25 Supplied and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dip galvanised self dirilling and self tapping screws neoprene and EPDM washers complete all as specified, directed and as per manufacturer's instructions BI01010001010000000000000515BI0100001136 250 Sqm
26 26 Supplied and fixed pre- painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws neoprene and EPDM washers complete all as specified, directed and as per manufacturer's instructions BI01010001010000000000000515BI0100001137 15 Sqm
27 27 Supplied and fixed Tee grid suspension system of size 600 mm x600 mm type-1 made out of rolled framed hot dipped galvanised steel zinc coated of not less than 120 gm/sqm ,main runner shall be 0.3 mm thick of section 24 mmX33 mm cross runner 0.3 mm thickof section 24 mmx25 mm,wall angle shall be 0.63 mm thick of section 24 mmx24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod ,system exposed portion shall be pre painted polyster coated in off white/white in colour complete with material,fixing, jointing etc all as per manufactures instructions and directed. ( Make:- METROC or METACIL or any other equivalent make as approved by GE. BI01010001010000000000000515BI0100001138 220 Sqm
28 28 Supplied and fixed fibre cement coloured textured designer ceiling board 4mm thick of size 595x595 mm conforming to IS : 14862 & IS : 2380 Part-XIV fixed to timber / GI / Aluminium frame work with screws/clips complete all as per manufactures instructions and as directed.\nMake : Everest, Charminar, UPAL. BI01010001010000000000000515BI0100001139 80 Sqm
29 29 M&L for MS angle as in rafter rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces cleats etc conforming to Fe-410 W (Gde E-250) quality complete all as specified and directed BI01010001010000000000000515BI0100001140 200 Kg
30 30 M&L for 18-20 mm thick machine cut Kota stone slabs of size 580mm x 580mm in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the stone slabs, including necessary grinding rubbing rounding to exposed edges and polising in granite finish complete all as specified and directed. BI01010001010000000000000515BI0100001141 80 Sqm
31 31 All as per Srl item No 30 here-in-before but on vertical surfaces BI01010001010000000000000515BI0100001142 2 Sqm
32 32 M& L for mirror polishing (granite polishing) to stone slabs any type in floors and vertical surfaces includig minor repair to stone slabs wherever required complete all as specified and directed. BI01010001010000000000000515BI0100001143 70 Sqm
33 33 M&L for providing coloured designer tiling, exterior grade (ENDURA or equivalent as approved by GE) 10 to 12 mm thick set, jointed & pointed in neat cement slurry with gray cement and pigment to match shade / colour / matrix of tiles in floors complete all as specified and directed. BI01010001010000000000000515BI0100001144 30 Sqm
34 34 M & L for laying Non Skid ceramic tiles 7 to 8 mm thick, (square / rectangular) jointless area of each tile exc 0.11sqm but n.exc 0.18 sqm first quality coloured of grade B II (a) /B II (b) and of abrasion resistance - PE I -III or above , in floors etc, set in neat cement slurry over CM screed (screed shall be measured and paid for separately under respective item), jointed and grouted with tile epoxy grout complete all as specified and directed". BI01010001010000000000000515BI0100001145 30 Sqm
35 35 M & L for light shade vitrified tiles 10mm thick (minimum), (square / rectangular) polished, area of each tiles exceeding 0.36 Sqm (including 600mmx600mm size) but not exceeding 0.42 Sqm, in skirting / dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the clour of tiles and over CM screed bed (screed shall be measured and paid for separately under respective item) complete all as specified and directed". BI01010001010000000000000515BI0100001146 20 Sqm
36 36 M & L for light shade vitrified tiles 10mm thick (minimum), (square / rectangular) polished, area of each tiles exceeding 0.36 Sqm (including 600mmx600mm size) but not exceeding 0.42 Sqm, floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the clour of tiles and over CM screed bed (screed shall be measured and paid for separately under respective item) complete all as specified and directed". BI01010001010000000000000515BI0100001147 20 Sqm
37 37 M&L for Glazed ceramic tiles coloured 300mmx 450mm X 7 mm thick first quality of grade B tiles on vertical surface such as skirting / dados etc set in neat cement slurry over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and and directed BI01010001010000000000000515BI0100001148 30 Sqm
38 38 M&L for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in floor/plinth protection , finish even & smooth without using extra cement complete all as specified and directed. BI01010001010000000000000515BI0100001149 70 Sqm
39 39 M&L for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed. BI01010001010000000000000515BI0100001150 30 Sqm
40 40 Dismantling of floor, hearth or wall tiles / terrazzo including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises, complete all as specified and directed. BI01010001010000000000000515BI0100001151 212 Sqm
41 41 M&L in repair for laying 60 mm thick machine pressed precast PCC coloured interlocking paver block moulded in PVC frame / mould any shape and size conforming to IS 15658-2006 of M-35 grade of approved design with gray cement and pigment to match shade / colour / matrix of tiles set and bedded over and including 50mm thick fine river washed sand duly compacted with surface vibrator laid over compacted sub soil in flooring complete all as specified and directed.\nMake : NITCO, Mumbai ; Redsun tiles & Pavers, panchkula ; Star Tiles & Industries, Rama Devi, Kanpur ; Mayur tiles & Interlocking Pavers, Lucknow ; Mehatab tiles, indore ; Tulip Infrastructure, Saharanpur (U.P) BI01010001010000000000000515BI0100001152 30 Sqm
42 42 M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. BI01010001010000000000000515BI0100001153 230 Sqm
43 43 M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or one side of lathing on stone masonary surfaces concrete surface, finished even & smooth without using extra cement complete all as specified and directed. BI01010001010000000000000515BI0100001154 150 Sqm
44 44 M&L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. BI01010001010000000000000515BI0100001155 32 Sqm
45 45 M&L for screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. BI01010001010000000000000515BI0100001156 160 Sqm
46 46 Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and directed. BI01010001010000000000000515BI0100001157 380 Sqm
47 47 M&L for preparing the new plastered surfaces and applying three coats of white lime washing on walls complete all as specified and direcrted. BI01010001010000000000000515BI0100001158 380 Sqm
48 48 M&L preparation of newly plastered surface of wall and applying two coat of oil emulsion distemper over a coat of chalk whiting complete all as specified and directed BI01010001010000000000000515BI0100001159 380 Sqm
49 49 M&L for complete removal of existing treatment and preparing of old decorated surfaces of walls ( plastered or un plastered ) including cornices etc and applying 2mm thick wall care putty complete all as specified and directed BI01010001010000000000000515BI0100001160 300 Sqm
50 50 M&F for preparation of old surfaces of wall including scraping down smoke soots,moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or un plastered surfaces) and applying one coat of white (lime) wash complete all as specified and directed BI01010001010000000000000515BI0100001161 500 Sqm
51 51 M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm in width or girth and applying two coat of white / tinted synthetic enamel paint over a coat of pink primer complete all as specified and directed. BI01010001010000000000000515BI0100001162 108 Sqm
52 52 M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 in cm width or girth and applying two coats of white / tinted synthetic enamel paint complete all as specified and directed . BI01010001010000000000000515BI0100001163 20 Sqm
53 53 M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. BI01010001010000000000000515BI0100001164 20 Sqm
54 54 M&L for preparation of old painted steel surface of any description over 10 cm in width or girth and applying two coats of white / tinted synthetic enamel paint complete all as specified and directed BI01010001010000000000000515BI0100001165 50 Sqm
55 55 M&L for 3 mm thick sheet glass, ordinary quality and glazing with oil putty or glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed. BI01010001010000000000000515BI0100001166 40 Sqm
56 56 Hacking out old broken glass (any thickness, size,quality or description) from metal frames including punching or drilling out old glazed pins / spring clip and rubbish off the premises complete all as specified and directed. BI01010001010000000000000515BI0100001167 40 Sqm
57 57 Taking up or down GI water tubing 15mm bore and connection including cleaning serviceable pipes for refixing and unserviceable removal from the site complete all as secified and directed BI01010001010000000000000515BI0100001168 18 RM
58 58 Taking up or down GI water tubing 20mm bore and connection including cleaning serviceable pipes for refixing and unserviceable removal from the site complete all as secified and directed BI01010001010000000000000515BI0100001169 18 RM
59 59 Supplied and fixed GI water tubing 15 mm bore medium grade with all fittings fixed to walls and ceiling or laid in floors including cutting screwing and waste etc complete all as specified and directed. BI01010001010000000000000515BI0100001170 18 RM
60 60 Supplied and fixed GI water tubing 20 mm bore medium grade with all fittings fixed to walls and ceiling or laid in floors including cutting screwing and waste etc complete all as specified and directed. BI01010001010000000000000515BI0100001171 18 RM
61 61 M&L for 1mm thick MS plain sheet for making modified lid of water tank and fixed with 04 nuts and bolts for water tanks for water capacity n.exc 750 ltr complete all as specified and directed BI01010001010000000000000515BI0100001172 40 Each job
62 62 Dismantling of old water tank exc 250 ltr & n.exc 500 ltr capacity and Supplied, hoisted and fixed in position rotational moulded polyethylence water storage tanks IS : 12701 - 1996 marked (cylindrical vertical with closed top) of 500 Ltrs capacity with and including 20mm dia Ball valve high pressure of PTMT with apoxy aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and directed. BI01010001010000000000000515BI0100001173 4 Each
63 63 S&F in repairs 15mm bore dia Ball valve high pressure of PTMT with epoxy aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 142 gms Make - 'Prayag' / Polytuff complete all as specified and directed. BI01010001010000000000000515BI0100001174 30 Each
64 64 S&F in repairs bib tap, C P cast copper alloy fency type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed. BI01010001010000000000000515BI0100001175 50 Each
65 65 S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and of 20 mm bore and fixed complete all as specified and directed. BI01010001010000000000000515BI0100001176 20 Each
66 66 S&F bib tap standard of PTMT any colour high pressure screwed for iron pipe of 15 mm bore and fixed (Minimum weight 15mm - 90gms complete all as specified and directed. BI01010001010000000000000515BI0100001177 50 Each
67 67 S&F in repair stop valve of PTMT any colour high pressure screwed for iron pipe of 15 mm bore and fixed. (Minimum weight 15mm- 90gms/20mm-92gms) complete all as specified and directed. BI01010001010000000000000515BI0100001178 25 Each
68 68 S&F PVC connections 15mm size with brass check nuts and PVC washers at both ends of length 300mm complete all as specified and directed BI01010001010000000000000515BI0100001179 30 Each
69 69 Supplied and fixed 110mm bore UPVC(SWR) pipes (pressure rating 6 kgf / sqcm) single socketed in any length with rubber ring joint, fixed to walls complete all as specified and directed. BI01010001010000000000000515BI0100001180 12 RM
70 70 Supplied and fixed 75 mm bore UPVC(SWR) pipes single socketed in any length with rubber ring joint laid in trenches/under floor complete all as specified and directed. BI01010001010000000000000515BI0100001181 12 RM
71 71 Supplied and fixed UPVC (SWR) floor trap 75 mm bore including jointing to waste pipe fixed in cement concrete complete all as specified and directed BI01010001010000000000000515BI0100001182 6 Each
72 72 Supplied and fixed PVC (SWR) gully trap 125/100 mm bore setting and jointing with solvent cement complete all as specified and directed BI01010001010000000000000515BI0100001183 6 Each
73 73 Supplied and fixed in repair vitreous china WHB white flat back size 550x400mm including Supplied and fixed angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed. BI01010001010000000000000515BI0100001184 2 Each
74 74 Supply and fixing vitreous china squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of lime concrete bedding and making connection with & including PVC "P" Trap including breaking up existing damaged WC seat etc complete all as specified and directed. BI01010001010000000000000515BI0100001185 3 Each
75 75 Supply and fixing in repairs PVC low level flushing cistern of 10 Ltr capacity syphonic action type with inlet ball valve, float and handle including PVC brackets for mounting of cistern complete all as specified and directed. BI01010001010000000000000515BI0100001186 7 Each
76 76 S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. BI01010001010000000000000515BI0100001187 5 Each
77 77 Supplied and fixed Bevelled edge looking mirror of size 600mmx450mmx4.8 to 5mm thick selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified & directed. BI01010001010000000000000515BI0100001188 3 Each
78 78 Demolition and breaking up drain pipes ( SGSW, AC or reinforced concrete) or PVC pipe set in cement mortar for 75mm / 100mm / 110mm internal dia of pipe and including removal from the site complete all as specified and directed. BI01010001010000000000000515BI0100001189 24 RM
79 79 Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and directed. BI01010001010000000000000515BI0100001190 7 Cum
80 80 Demolition of cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) and including removal of debris & rubbish from the site complete all as specified and directed.\nNote : Stone slabs / tiles and hard core of any description shall not be measured & paid under this item. BI01010001010000000000000515BI0100001191 60.25 Cum
81 81 Dismantling AC sheet corrugated or semi corrugated sheet of any description as in roof and including removal from the site complete all as specified and directed. BI01010001010000000000000515BI0100001192 250 Sqm
82 82 Dismantling of wall or ceiling board (fiber,pulp,insulation etc) any thickness including cover fillets and removal from the site complete all as specified and directed. BI01010001010000000000000515BI0100001193 80 Sqm
83 83 Dismantling of aluminium false ceiling snap grid of any description complete all as specified and directed BI01010001010000000000000515BI0100001194 80 Sqm
84 84 S&F in repairs 32mm dia PVC waste pipe for WHB / urinal 60cm long with union complete all as specified and directed. BI01010001010000000000000515BI0100001195 60 Each
85 85 S&F PTMT tower bolts 200mm size fixed with machine screws, make : Symit complete all as specified and directed BI01010001010000000000000515BI0100001196 13 Each
86 86 S&F PTMT Bow Handles 150 mm size fixed with machine screws, Make : Symit complete all as specified and directed BI01010001010000000000000515BI0100001197 13 Each
87 87 S&F in repair gate valve 15mm cast copper alloy chromium plated fancy type with capstan heads screwed doen high pressure with crutch or butterfly handle screwed for 15mm bore iron fixed complete all as specified and directed BI01010001010000000000000515BI0100001198 8 Each
88 88 S&F in repair gate valve 20mm cast copper alloy chromium plated fancy type with capstan heads screwed doen high pressure with crutch or butterfly handle screwed for 20mm bore iron fixed complete all as specified and directed BI01010001010000000000000515BI0100001199 8 Each
89 89 S&F in repair internal syphon kit (complete with all fittings) for PVC low level flushing cistern complete all as specified and directed BI01010001010000000000000515BI0100001200 20 Each set
90 90 S&F in repair PVC flushing cistern handle / knob only complete all as specified and directed BI01010001010000000000000515BI0100001201 7 Each
91 91 S&F in repair PVC flushing cistern float valve 15mm bore complete complete all as specified and directed BI01010001010000000000000515BI0100001202 7 Each
92 92 S&F in repair 15mm PTMT push cock of any colour high pressure screwed for iron pipe and fixed (Min weight 15mm - 90 Gm) Make Prayag / Pearl complete all as specified and directed BI01010001010000000000000515BI0100001203 25 Each
93 93 S&F in repair PVC connection fiber, reinforced 300mm long with brass check nut and PVC washers at both ends complete all as specified and directed BI01010001010000000000000515BI0100001204 30 Each
94 94 Taking down copper/aluminium point wiring (ligh, fan, bell, socket or power etc.) complete with all accessories like switches, sockets, regulators, ceiling roses, light fittings etc. for taking credit and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floors / ceiling etc all as specified. BI01010001010000000000000515BI0100001205 812 Per point
95 95 Taking down carefully all type of sub main wiring any core including batten / conduit and making good to disturbed surface as matching to existing complete all as specified and directed. BI01010001010000000000000515BI0100001206 250 RM
96 96 M&L for concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, Fire Retardant, conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunken zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly including cutting holes in or through the walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as directed for one light / fan / bell point controlled by one, one way switch / bell push button. BI01010001010000000000000515BI0100001207 400 Per point
97 97 All as per Srl item No 96 here-in-before but one out let socket point 3pin 5 amps on independent board. BI01010001010000000000000515BI0100001208 50 Per point
98 98 All as per Srl item No 96 here-in-before but on the same board with other switches BI01010001010000000000000515BI0100001209 50 Per point
99 99 All as per Srl item No 96 here-in-before but using 2.5 sqmm copper conductor for with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed. BI01010001010000000000000515BI0100001210 25 Per point
100 100 All as per Srl item No 96 here-in-before but using 4 sqmm copper conductor for with 4 sqmm earth wire for one 20 amps socket outlet on independent board all as directed. BI01010001010000000000000515BI0100001211 10 Per point
101 101 All as per Srl item No 96 here-in-before but for supply and drawing 1.5 sqmm copper conductor cable with one 1.5 sqmm continuous earth wire into existing conduit after taking out the existing wiring including replacement of required size of terminal box with 3mm thick bakelite sheet cover fixed with brass screws all as directed for One light/fan/bell point wiring controlled by one, one way switch/bell push button. BI01010001010000000000000515BI0100001212 150 Per point
102 102 All as per Srl item No 101 here-in-before but one out let socket point 3pin 5 amps on independent board. BI01010001010000000000000515BI0100001213 20 Per point
103 103 All as per Srl item No 101 here-in-before but on the same board with other switches BI01010001010000000000000515BI0100001214 20 Per point
104 104 All as per Srl item No 101 here-in-before but using 2.5 sqmm copper conductor and with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed. BI01010001010000000000000515BI0100001215 15 Per point
105 105 All as per Srl item No 101here-in-before but using 4 sqmm copper conductor and with 4 sqmm earth wire for one 20 Amps socket outlet on independent board all as directed. BI01010001010000000000000515BI0100001216 5 Per point
106 106 All as per Srl item No 101 here-in-before but with sunk zinc coated pressed steel terminal boxes suitable for modular fixtures including suitable Modular box, base plate and outer plate all as directed for One light/fan/bell point controlled by one, one way modular switch 06 Amps. BI01010001010000000000000515BI0100001217 40 Per point
107 107 All as per Srl item No 101 here-in-before but One 06 Amps socket outlet point on independent board controlled by one, one way modular switch 06 Amps. BI01010001010000000000000515BI0100001218 10 Per point
108 108 All as per Srl item No 101 here-in-before but One 06 Amps socket outlet point on same board controlled by one, one way modular switch 6 Amps. BI01010001010000000000000515BI0100001219 10 Per point
109 109 All as per Srl item No 101 here-in-before but with 2.5 Sqmm nominal cross sectional area copper conductor cable with earth wire 2.5 sqmm for one 16 Amps socket outlet point on independent board. BI01010001010000000000000515BI0100001220 5 Per point
110 110 All as per Srl item No 101 here-in-before but with 4 Sqmm FR PVC insulated and FR PVC unsheathed stranded copper conductor cable for and 4 Sqmm used as earth wire for indpendent 20 Amps socket point on independent board. BI01010001010000000000000515BI0100001221 2 Per point
111 111 S&F in repairs switch piano flush type, 5A, AC, 240V, one way ISI Marked all as specified.. BI01010001010000000000000515BI0100001222 1400 Each
112 112 S&F in repairs switch piano flush type,15A, AC, 240V, one way ISI Marked and as specified BI01010001010000000000000515BI0100001223 150 Each
113 113 S&F in repairs Bell Push, Flush type, 5A, AC, 240V, ISI Marked and as specified BI01010001010000000000000515BI0100001224 25 Each
114 114 S&F in repairs socket flush type, 5A, 5pin, AC, 240V ISI Marked and as specified BI01010001010000000000000515BI0100001225 350 Each
115 115 S&F in repairs socket flush type, 15A, 6pin, AC, 240V ISI Marked and as specified BI01010001010000000000000515BI0100001226 150 Each
116 116 S&F in repairs Electronic Step type socket size Fan Regulator, 240V, AC, 240V, ISI Marked and as specified BI01010001010000000000000515BI0100001227 60 Each
117 117 S&F in repairs Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and as specified. BI01010001010000000000000515BI0100001228 75 Each
118 118 S&F in repairs Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked and as specified. BI01010001010000000000000515BI0100001229 15 Each
119 119 S&F in repairs Modular Bell Push, 1 module, 6A, AC, 240V, ISI Marked and as specified. BI01010001010000000000000515BI0100001230 3 Each
120 120 S&F in repairs Modular Step Fan Regulator, 2 module, 120W, AC, 240V, ISI Marked and as specified. BI01010001010000000000000515BI0100001231 10 Each
121 121 S&F in repairs Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and as specified. BI01010001010000000000000515BI0100001232 25 Each
122 122 S&F in repairs Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and as specified. BI01010001010000000000000515BI0100001233 15 Each
123 123 S&F in repairs Modular Power Switch and Socket Unit with factory made poly carbonate modular box, 20A, 3pin, AC, 240V incl 20A MCB SP and Plug Top ISI Marked all as directed. Make: Havells / IndoAsian / Legrand BI01010001010000000000000515BI0100001234 25 Each
124 124 S&F in repairs lamp holder, Polycarbonate, Angle / Straight batten back plate, AC, 240V, Pin type, ISI marked all as specified. BI01010001010000000000000515BI0100001235 400 Each
125 125 S&F in repairs Ceiling rose surface Bakelite 65x50mm, 3 terminals, AC, 240V, ISI Marked all as specified. BI01010001010000000000000515BI0100001236 250 Each
126 126 S&F in repairs Call Bell, AC, 240V, SP, ISI Marked all as specified. BI01010001010000000000000515BI0100001237 50 Each
127 127 S&F in repairs fan Condenser or Capacitor 2.5 mfd 240 Volts ISI marked all as specified. BI01010001010000000000000515BI0100001238 100 Each
128 128 All as per Srl item No 127 here-in-before but 4.0 mfd BI01010001010000000000000515BI0100001239 10 Each
129 129 S&F in repairs high lumen (Minimum 100 Lum/Watt) LED pre wired ceiling panel light fitting, Recess mounted, 2'x2', 36 watts, AC, 240V, 6500K with control driver unit all as specified. BI01010001010000000000000515BI0100001240 40 Each.
130 130 S&F in repairs, LED pre wired Wall mounting fancy light fitting with polycarbonate diffuser prewired incl high lumen (Minimum 100 Lum/Watt) B22 9 Watts 6500K LED lamp, Make: Havells, Model: Beetle or equivalent model of Make: Philips / Wipro all as directed. BI01010001010000000000000515BI0100001241 20 Each
131 131 S&F in repairs die-cast alluminium housing high lumen (Minimum 100 Lum/Watt) 10/12 Watts, 6500K, 240V, AC, LED flush or surface mounting pre wired down light luminaire square or round with control driver all as directed. Make: Havells / Philips / Wipro BI01010001010000000000000515BI0100001242 10 Each
132 132 S&F in repairs integrated high lumen (Minimum 100 Lum/Watt) LED tube light fitting, pre wired, surface mounting, Poly carbonate batten, 4 foot, 240V, AC, T5, 20 Watt all as directed. BI01010001010000000000000515BI0100001243 450 Each
133 133 All as per Srl item No 132 here-in-before but 2 foot, 9 Watt BI01010001010000000000000515BI0100001244 25 Each
134 134 S&F in repairs high lumen (Minimum 100 Lum/Watt) T-8 poly carbonate diffuser type 20 watt single end LED retrofit tube rod, 4 foot, 240V, AC all as directed. BI01010001010000000000000515BI0100001245 400 Each
135 135 S&F in repairs, IP65, Post Top, energy saving spun Aluminium landscape luminaire with 15 Watts high power LEDs of Make: Havells Model: Ruby (Clear) / Coral (Opal) or equivalent model of Make: Philips / Wipro complete all as directed. BI01010001010000000000000515BI0100001246 5 Each
136 136 S&F in repairs high lumen (Minimum 100 Lum/Watt) 25 Watt, 240V pewired LED street light luminaire having minimum 5KV surge protector incl 32mm OD GI pipe bracket, two nos suitable size mounting anchoring bolts with nuts and washers complete all as directed. BI01010001010000000000000515BI0100001247 5 Each
137 137 S&F in repairs high lumen (Minimum 100 Lum/Watt) 45 Watt prewired LED Flood light luminaire incl two nos suitable size mounting anchoring bolts with nuts and washers complete all as directed. BI01010001010000000000000515BI0100001248 5 Each
138 138 S&F in repairs LED control Driver suitable for any make or model LED street / ceiling panel light fitting 24 to 50 Watts, 240V all as directed BI01010001010000000000000515BI0100001249 20 Each
139 139 All as per Srl item No 138 here-in-before but suitable for 7 to 15 Watts down light luminaire BI01010001010000000000000515BI0100001250 5 Each
140 140 S&F in repair high lumen (Minimum 100 Lum/Watt) LED lamp, 12 Watts, 6500K, 2 pin with B22 base, clear acrylic diffuser all as directed BI01010001010000000000000515BI0100001251 400 Each
141 141 All as per Srl item No 140 here-in-before but 9 Watts BI01010001010000000000000515BI0100001252 400 Each
142 142 All as per Srl item No 140 here-in-before but 5 Watts BI01010001010000000000000515BI0100001253 200 Each
143 143 S&F in repair Metallic Enclosure, SPN DB, 240V, AC, single door 2 way, ISI Marked all as directed BI01010001010000000000000515BI0100001254 2 Each
144 144 All as per Srl item No 143 here-in-before but double door 4 way with 200Amps rated busbar BI01010001010000000000000515BI0100001255 2 Each
145 145 All as per Srl item No 143 here-in-before but double door 8 way with 200Amps rated busbar BI01010001010000000000000515BI0100001256 10 Each
146 146 All as per Srl item No 143 here-in-before but double door 12 way with 200Amps rated busbar BI01010001010000000000000515BI0100001257 10 Each
147 147 All as per Srl item No 143 here-in-before but double door TPN DB, 415V, 4way with 200Amps rated busbar BI01010001010000000000000515BI0100001258 2 Each
148 148 All as per Srl item No 143 here-in-before but double door TPN DB, vertical mounting with incomer for MCCB, 415V, 4way with 200Amps rated busbar BI01010001010000000000000515BI0100001259 1 Each
149 149 S&F in repair MCB SP 6 to 32 A, AC, 240V, 10KA, ISI Marked all as specified. BI01010001010000000000000515BI0100001260 300 Each
150 150 S&F in repair Isolator DP, 40A, AC, 240V, ISI Marked all as specified. BI01010001010000000000000515BI0100001261 50 Each
151 151 S&F in repair Isolator 4P, 63A, AC, 415V, ISI Marked all as specified. BI01010001010000000000000515BI0100001262 5 Each
152 152 S&F in repair Isolator 4P, 100A, AC, 415V, ISI Marked all as specified. BI01010001010000000000000515BI0100001263 5 Each
153 153 S&F in repair RCCB / ELCB, DP, AC, 40A, 30mA, 240V ISI Marked all as specified. BI01010001010000000000000515BI0100001264 2 Each
154 154 S&F in repair RCCB / ELCB, 4P, AC, 63A, 30mA, 415V ISI Marked all as specified. BI01010001010000000000000515BI0100001265 2 Each
155 155 S&F in repairs, 4 Pole MCCB 63 Amp, 50 Hz, 415 V, 18KA with adjustable Thermal - Magnetic Release BI01010001010000000000000515BI0100001266 2 Each
156 156 All as per Srl item No 155 here-in-before but 100Amps. BI01010001010000000000000515BI0100001267 2 Each
157 157 All as per Srl item No 155 here-in-before but 125Amps, 25KA BI01010001010000000000000515BI0100001268 1 Each
158 158 All as per Srl item No 155 here-in-before but 160Amps BI01010001010000000000000515BI0100001269 1 Each
159 159 All as per Srl item No 155 here-in-before but 200Amps BI01010001010000000000000515BI0100001270 1 Each
160 160 S&Fix in repairs, tamper proof Electronic KWh meter with LCD/LED display, 1Ø, 5-30A incl T/D old u/s one and depositing to MES. BI01010001010000000000000515BI0100001271 10 Each
161 161 All as per Srl item No 160 here-in-before but 3 phase 10 - 60 A. BI01010001010000000000000515BI0100001272 2 Each
162 162 S&Fix in repairs, 1100V grade PVC insulated flexible twisted twin core Fire Retardant cable with multistranded copper conductor of size 1.5Sqmm, ISI Marked BI01010001010000000000000515BI0100001273 180 RM
163 163 S&Fix in repairs, 1100V grade overall PVC sheathed, PVC insulated flexible two core Fire Retardant cable with multistranded copper conductor of size 1.5Sqmm, ISI Marked BI01010001010000000000000515BI0100001274 90 RM
164 164 All as per Srl item No 163 here-in-before but 3 core 2.50Sqmm BI01010001010000000000000515BI0100001275 90 RM
165 165 S&Fix in repair copper cable 1.5 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed. BI01010001010000000000000515BI0100001276 360 RM
166 166 S&Fix in repair copper cable 2.5 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed. BI01010001010000000000000515BI0100001277 270 RM
167 167 S&Fix in repair copper cable 4 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed. BI01010001010000000000000515BI0100001278 270 RM
168 168 S&Fix in repair copper cable 6 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed. BI01010001010000000000000515BI0100001279 180 RM
169 169 S&F in repairs, 1100 volts grade heavy duty PVC sheathed stranded Aluminium conductor twin core cable flat or circular of size 10 Sqmm. BI01010001010000000000000515BI0100001280 200 RM
170 170 Supply only insulation tape roll 20 mm wide 7 Mtr long ISI mared all as directed. Make: Steelgrip / Kinjal / Anchor BI01010001010000000000000515BI0100001281 50 Roll
171 171 S&Fix in repairs, ceiling fan, 1200mm sweep, AC, 240V incl T/D old u/s one and depositing to MES all as directed. Make: Havells / Orient / Crompton / Usha BI01010001010000000000000515BI0100001282 2 Each
172 172 All as per Srl item No 171 here-in-before but 1400mm sweep BI01010001010000000000000515BI0100001283 2 Each
173 173 S&Fix in repairs, Wall fan, 450mm sweep, AC, 240V incl T/D old u/s one and depositing to MES all as directed. Make: Havells / Orient / Crompton / Usha BI01010001010000000000000515BI0100001284 2 Each
174 174 S&Fix in repairs, PVC fresh air fan, 250mm sweep with lovers, AC, 240V incl T/D old u/s one and depositing to MES all as directed. Make: Havells / Orient / Crompton / Usha BI01010001010000000000000515BI0100001285 2 Each
175 175 All as per Srl item No 174 here-in-before but 200mm. BI01010001010000000000000515BI0100001286 2 Each
176 176 S&Fix in repairs, Heavy Duty Metallic Exhaust fan, 450mm sweep, AC, 240V incl T/D old u/s one and depositing to MES all as directed. Make: Havells / Orient / Crompton / Usha BI01010001010000000000000515BI0100001287 2 Each
177 177 Supply, Install, Test & Commissioniong, Water Resistant / Splash Proof (IPX-4), Whirlflow technology, Electric Water Storage Heater (Geyser) 25 Ltrs capacity, AC, 230V, Vertical Type, 5 Star Rated, ISI Marked, Energy Efficient, having Feroglass coated / Anode Rod protected inner container / Tank, Incoloy Glass Coated Heating Element, High Density PUF insulated, Multi Function Safety Valve, Fire Retardant ISI Marked Heavy duty 3 core cable with shock Resistant Plug Top, Temperature Sensitive LED indicators, Adjustable Temperature Setting, 0.8MPa high working Pressure, Complete including suitable size Anchoring / Grouting Bolts with Nuts & Washers, necessary grouting in PCC incl earthing testing for the Geyser, Colour : White, Make : Venus / Havells / Racold incl T/D old u/s one and depositing to MES complete all as directed BI01010001010000000000000515BI0100001288 2 Each
178 178 All as per Srl item No 177 here-in-before but 50 Ltrs BI01010001010000000000000515BI0100001289 1 Each
179 179 S&F in repairs, Heating element, 1.5KW, ISI Marked with heat resistant heavy duty rubber washer, long or medium size, round, triangular or square type, suitable for any model / make geyser, 240V, AC all as directed. Make: Bajaj / Havells / Venus / Racold BI01010001010000000000000515BI0100001290 25 Each
180 180 All as per Srl item No 179 here-in-before but 2.0KW BI01010001010000000000000515BI0100001291 5 Each
181 181 S&F in repairs, Heating element of 3.0KW, B.S.P threaded with thermostat pocket and metal cap suitable for any model / make / capacity solar water heater all as per existing one and as directed. BI01010001010000000000000515BI0100001292 5 Each
182 182 S&F in repairs, Thermostat control unit, any shape, long or medium size, suitable for any model / make / capacity geyser or solar water heater, 30-90 degree rating, 240V, AC, ISI Marked all as directed. Make: Bajaj / Havells / Venus / Racold BI01010001010000000000000515BI0100001293 5 Each
183 183 S&F in repairs, low density polyethlyne pipe 16 mm dia (outer), heavy duty, 450mm long suitable for Hot water application complete with threaded brass union, teflone washers on both sides to suit 15 mm dia fittings. Make: WaterTec / Havells / Parryware BI01010001010000000000000515BI0100001294 40 Each
184 184 S&F in repairs, 3 Brass Pin Plug Top with Backelite body, Heavy duty, 15A, 240V, AC, ISI Marked all as directed. Make: Havells / Anchor / Orpat / Kinjal BI01010001010000000000000515BI0100001295 20 Each
185 185 M/L for round opening in the wall for fixing exhaust fan 200 to 250mm, PCC / plastering work, making good the surfaces as directed. BI01010001010000000000000515BI0100001296 4 Each Job
186 186 Material and labour for 3 phase sub main wiring with 06 Sqmm nominal cross sectional area, four run of single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FR- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including two run of continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 32mm dia, medium grade with all PVC conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note:- One meter of conduit along with 6x6 Sqmm cable shall be measured as one unit length. BI01010001010000000000000515BI0100001297 50 RM
187 187 All as per Srl item No 186 here-in-before but single phase sub main wiring with 2 run 6Sqmm + 1run 6Sqmm earth in 25mm conduit (3x6Sqmm - one unit length) BI01010001010000000000000515BI0100001298 200 RM
188 188 Carrying out Electrical maint work of day to day Internal Electric or Fans or Geysers or Solar Water Heaters complaints such as repair / rectification / replacement of defective items like wiring, cables, switches, sockets, holders, c/rose, call bells, condensers, tube rods, fitting, fixtures, LED drivers, MCB's, MCCB's, DB's, Heating Elements, Thermostats, Hot water connections etc. by providing skilled Electrician at any location under GE (North) Meerut AoR all as specified and directed by Engr-in-Charge. (Store required will be provided seperately) BI01010001010000000000000515BI0100001299 3000 Each Job
189 189 M/L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level GI / steel earth plate and GI wire 4mm dia upto 7.50 Mtr length connected by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel, GI protection pipe 15mm bore light grade upto DB all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, 2 Mtr 50 mm dia medium grade GI watering pipe with GI female socket and GI male Plug including testing on completion complete all as directed. BI01010001010000000000000515BI0100001300 10 Each Job