Special Repairs To Bldg No Xxvii At Offrs Mess Guest Rooms Under Ge Wellington, WELLINGTON-Tamil Nadu

Military Engineer Services-MES has published Special Repairs To Bldg No Xxvii At Offrs Mess Guest Rooms Under Ge Wellington. Submission Date for this Tender is 13-02-2021. Building Repair Tenders in WELLINGTON Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

26699047
Corrigendum : Special Repairs To Bldg No Xxvii At Offrs Mess Guest Rooms Under Ge Wellington
National Competitive Bid
Indian
Tamil Nadu
WELLINGTON
13-02-2021

Tender Details

Special Repairs To Bldg No Xxvii At Offrs Mess Guest Rooms Under Ge Wellington

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIRS TO BLDG NO XXVII AT OFFRS MESS GUEST ROOMS UNDER GE WELLINGTON
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down the complete existing water proofing treatment of any description over roof slab etc., all as specified and directed.\nNotes on :-\n1. The unit rate shall be deemed to included the cost of removing the vegetaion like plants, grass, etc, demolished materials if any on roof slab and cleaning the blockage in rain water pipes if any as required and as directed.\n2. The unit rate shall be deemed includeing the cost of removing the demolished maretials to a diatance exceeding 50m but not exceeding 250m. 300 SQM
2 2 M&L Demolition of existing cement concrete and provision for 25 mm thick, plain cement concrete type B0, 1:2:4 (using 12.5 mm graded aggregate) as in roof padding/leveling coarse kerbs, or chamfered on edges finished even and smooth using extra cement and mixed with water proofing compound complete all as specified and directed.\nNote:- The cost of supply only the integral water proofing compound shall be measured and paid separately. 300 SQM
3 3 M&L for roughning surface on roof slab and provision of rendering 20 mm thick in cement mortor 1:3 using integral water proofing compound on fair face of concrete surfaces of roof slab and finished even and fair without using extra cement complete all as specified and as directed.\nNote:- The cost of supply only the integral water proofing compound shall be measured and paid separately. 300 SQM
4 4 M&L for APP modified prefabricated polymeric membrane 4mm thick and weighing not less than 4.5 kg/sqm reinforced with non woven polyster matt black finished weighing not less than 100 gm /sqm having softning point not less than 140 degree celsius longitudinal tensile strength not less than 300N/Sqcm, side lap & end lap 10 cm with torch application of membrane, over compatible primer @0.40 Ltr/Sqm and finishing with aluminium paint applied @ 0.10 Kg/Sqm finished complete all as specified and directed.\nNote: The work shall be carried out by authorised applicator of manufacturer 300 SQM
5 5 Supply only Integral Water proofing compound complete all as specified and as directed. 130.43 KG
6 6 Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed. 10.5 CUM
7 7 M&L for brick work in CM 1:6 with sub class 'B' bricks, old size, straight or curved on plan exceeding 6m in mean radius complete all as specified and directed. 10.5 CUM
8 8 Taking down cement plaster on brick or stone walls or ceiling etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. 200 SQM
9 9 M&L for rendering 15 mm thick in cement mortar 1:6 finished even and smooth without using extra cement on fair faces of brick work/concrete / RR Masory surfaces complete all as specified and directed. 50 SQM
10 10 M&L for rendering 15 mm thick in cement mortar 1:4 finished even and smooth without using extra cement on fair faces of brick work/concrete wall surfaces complete all as specified and directed. 150 SQM
11 11 Dismantling water tank of capacity exceeding 250 and not exceeding 500 ltr and removing to stores complete all as specified and directed. 4 EACH
12 12 Dismantling water tank of capacity exceeding 1000 ltr and not exceeding 2000 ltr and removing to stores complete all as specified and directed. 4 EACH
13 13 S&F rotational moulded polythene water storage tanks, 2000 Ltr capacity, cylindrical, vertical with closed top, hoisted and fixed in position complete all as specified and as directed. 6 EACH
14 14 Taking up or down 20mm bore steel tubing and connection including cleaning for refixing or removal to store complete all as specified and as directed. 50 RM
15 15 Taking up or down 15mm bore steel tubing and connection including cleaning for refixing or removal to store complete all as specified and as directed. 100 RM
16 16 S&F 15 mm bore, galvanised steel water tubes, medium grade with all fittings and fixed to wall, celing, floors and concelaed complete all as specified and as directed. 50 RM
17 17 S&F 20 mm bore, galvanised steel water tubes, medium grade with all fittings and fixed to wall, celing, floors and concelaed complete all as specified and as directed. 50 RM
18 18 S&F concealed steel water tubing with 15mm bore galvanised steel water tubes, medium grade with all fittings and fixed to wall, celing or laid in floors and complete all as specified and as directed. 50 RM
19 19 M&L for filling surface cracks upto 5mm width with crack fill and wider cracks beyond 5mm trated with polymer modified mortar using LATEX or techno commercially equivalent complete all as per manufacturers instructions complete all as specified and as directed. 25 SQM
20 20 S&F in repairs PVC readymade bath room cabinet of size 450x550 with mirror shutters, fixed to wall with necessary screws and lugs complete all as specified and as directed. 6 EACH
21 21 S&F in repairs sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. \n(Make:- Cat No CAN-1173 of Jaquar make or techno commerically equal.) 6 EACH
22 22 Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed. 43.5 CUM
23 23 Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 360 SQM
24 24 M&L for coloured non skid ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4, as in floors etc. complete all as speicified and directed. 50 SQM
25 25 M&L for Vitrified tiles (Square/rectengular) dark shade 10mm thick, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick rendering in CM 1:4, as in floors complete all as speicified and directed. 260 SQM
26 26 M&L for glazed ceramic coloured tiles of size 450mm x350mmX7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in cement mortar 1:3, as in vertical surfaces such as dado, skirting etc complete all as directed. 50 SQM
27 27 Dismantling asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings complete all as specified and directed. 10 SQM
28 28 M&L for prepainted 0.5mm thick galvalume aluminum zinc coating GI based corrugated steel cloured having tensile strength of 550 Mpa as in roof covering & on chajjas fixed with self tapping screws as complete all as specified and directed. 10 SQM
29 29 Dismantling unframed timber scantlings 40 sqcm and over in section, as in any position/ tile batterns in roofing complete all as specified and directed. 0.2 CUM
30 30 S&F rolled mild steel works such as in main and cross beams, hip and jack rafters, purlins where connected to column rafters fixed with angle cleats or other connecting plates etc. conforming to Fe-290-Gde (Gde E-165) quality-A complete all as specified and directed. 50 KG
31 31 S&F in repair vitreous china wash hand basin Oval shape counter type, white, size 450mm x 300mm, excluding tap, but including fixing to wall with brackets or errecting stand complete all as specified and as directed. 6 EACH
32 32 S&F in repairs vitreous China wash down water closet pan (pedestal pattern), white, including seat cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. \n(Make;- Cat No. CNS-WHT-WSO2 of Jaquar or techno commercially equvilant ) 6 EACH
33 33 S&F in repairs 10 Ltr capacity PVC valve less syphonic action type flushing cistern low level with inlet, ball valve float and handle including brackets complete all as specified and as directed. 6 EACH
34 34 M&L 75mm dia PVC (SWR) floor trap/Nahani trap, plain with grating including jointing with solvent cement complete all as specified and directed. 12 EACH
35 35 S&F in repairs central hole basin mixer for mixing hot & cold water without popup waste system with 450mm long braided hose scrwed down for iron pipe 15mm bore complete all as specified and as directed. \n 6 EACH
36 36 S&F in repairs Brass CP wall mixer for mixing hot & cold water withprovision of over head shower with 115mm long bend pipe on upper side connecting legs and wall flanges scrwed down for iron pipe 15mm bore complete all as specified and as directed. \n(Make:- Cat No CQT-23273UPR of Jaquar or techno commercially equivalent.) 6 EACH
37 37 S&F in repairs 15 mm bore, angular/ stop valve, fancy type, chromium plated, cast copper alloy, high pressure, screwed down both side for iron pipe or for unions and fixed complete all as specified and as directed. 30 EACH
38 38 S&F in repair 15mm size PVC connection 450mm long with PTMT nuts complete all as directed and specified. 24 EACH
39 39 S&F in repairs chromium plated over head shower 150 x 150mm square shape single flow (body & face plate) fixed to steel pipe or union of 15mm bore complete all as specified and as directed. 6 EACH
40 40 S&F in repairs shower arm 20mm bore, 300mm long round shape with 90 degree bend for wall mointed showers with wall flanges chromium plated, complete all as specified and as directed. 6 EACH
41 41 S&F in repairs 15 mm bore bib taps with crutch or butter fly handle chromium plated cast copper alloy,screwed down for iron pipe or for brass ferrule complete all as specified and as directed. 12 EACH
42 42 S&F in repairs health faucet including all fittings chromium plated complete all as specified and as directed. 6 EACH
43 43 S&F in repairs soap dish holder chromium plated complete all as specified and as directed. 6 EACH
44 44 S&F in repairs tubular towel rail, brass, chromium plated, 20mm dia, D type, 600 mm long between flanges, complete all as specified and as directed. 12 EACH
45 45 S&F in repairs drapery rods aluminum anodised 20mm dia fancy type including brackets, stops, rollers etc, complete all as specified and as directed. 50 RM
46 46 S&F in repairs 900 mm x 600 mm x 5.5 mm thick bevelled edges looking mirror of selected quality glass, mounted on wall and fixed with PVC/plastic plugs chromium plated brass screws and cup washers with decorative beading 1st class hardwood of size 70 x 70 mm complete all as specified and as directed. 6 EACH
47 47 S&F in repairs toilet paper holders of vitrous china fixed to wall with brass chromium plated screws, complete all as specified and as directed. 6 EACH
48 48 Taking down wooden frames with shutters (without taking of the shutters from the frame) area not exceeding 1.5 sqm including cutting holes for taking out hold fasts, dismantling brick work (cutting holes and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) complete all as specified and as directed. 6 EACH
49 49 Taking down wooden frames with shutters (without taking of the shutters from the frame) area exceeding 1.5 sqm not exceeding 4 sqm including cutting holes for taking out hold fasts, dismantling brick work (cutting holes and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) complete all as specified and as directed. 6 EACH
50 50 S&F 100mm dia PVC (SWR) bends complete all as specified and as directed. 4 EACH
51 51 M&L for 2nd class hard wood plain, solid, straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered, put together with glue with pinned at joints complete all as specified and as directed. 0.3 CUM
52 52 S&F 35mm thick factory made second class hard wood, framed, panelled shutters (two panels) with lock rail and panels of timber flat ob sides (feather edged), or veneered particle board medium density, wood particle board with commercial face venners, suplied and fitted to chowkats complete all as specified and as directed. 10 SQM
53 53 S&F 35mm thick second class hard wood, glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc, edges of framing moulded, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as in windows, ventilators etc are provided with stiles and rails as specified as specified in SSR part-I, section 8, clause 8.24(b), suplied and fitted to chowkats complete all as specified and as directed. 10 SQM
54 54 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty/ woodenfillets/rubber beading in squares not exceeding 0.50 sqm in each pane as directed and complete all as specified and as directed. 10 SQM
55 55 M&L for preparation of new/previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 60 SQM
56 56 M&L for preparation of new/previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 60 SQM
57 57 S&F solid PVC factory made door frame of size 50x47mm made out of 5mm thick plain colour PVC sheet, reinforced with MS square tube complete all as specified and directed. 17 RM
58 58 M&L for factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and as directed. 8 SQM
59 59 M&L for forming jambs in CM 1:4 etc to openings (to foregoing item), including cutting, toothing properly bonding into old work, also facing, jointing and pointing to match existing work complete all as specified and as directed. 15 SQM
60 60 S&F 100mm size, mild steel butt hinges medium weight complete all as specified and as directed. 54 EACH
61 61 S&F 150mm long aluminium anodised handle, cast type complete all as specified and as directed. 36 EACH
62 62 S&F 300 mm length aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. 6 EACH
63 63 S&F 200mm long aluminium anodised barrel tower bolt extruded section complete all as specified and as directed. 54 EACH
64 64 M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. 50 SQM
65 65 M&L for preparation of old treated wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 150 SQM
66 66 M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and as directed. 50 SQM
67 67 M&L for complete removal of existing treatment on wall by scrapping, washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of primer over wall care putty and two coats of antifungal paint weather coating complete all as specified and directed. \nNote:- 1. Putty shall be measured and paid separetally.\n2. Painting shall be carried by authorized applicater of manufacturer. 800 SQM
68 68 M&L for applying one coat of 3mm thick wall care putty on wall/ceiling surfaces complete all as specified and directed. 1400 SQM
69 69 M&L for complete removal of existing treatment on wall by scrapping, washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of primer over wall care putty and two coats of oil bound emulsion distemper complete all as specified and directed. \nNote:- 1. Putty shall be measured and paid separetally.\n2. Painting shall be carried by authorized applicater of manufacturer. 800 SQM
70 70 M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed. \n 60 SQM
71 71 M&L for chequered cement concrete tiles 20 cm X 20 cm X 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry over and including 20 mm thick screed bed in CM 1:4, as in floors, complete all as specified and as directed. 60 SQM
72 72 M&L for providing 50mm thick, plain cement concrete 1:3:6, type C-2, using 40mm graded stone aggregates as in plinth protection laid in alternate bays complete all as specified and directed. 70 SQM
73 73 Demolition of reinforced cement concrete in ground floor and in paving not exceeding 15 cm thickness complete all as specified and as directed. 0.5 CUM
74 74 M&L for TMT Bars, 6 to 8mm dia, cut to length bent to shape, required, including cranking bending spirally or hooping for columns, hooking ends and binding withand including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 50 KG
75 75 M&L for precast RCC cover slab in cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in slabs with plain faces setting in CM 1:4 including necessary form work moulds etc complete all as specified and as directed. 0.5 CUM
76 76 M&L for plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, sesmic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed. 0.5 CUM
77 77 S&F mild steel works for bands, straps, support or stays, holdfast for doors, wall ties, hooks for hanging fans etc., confirming to Fe-290 Gde E-165 complete all as specified and as directed. 2 KG
78 78 S&F sanding newly tarred or painted surfaces with clean sharp sand complete all as specified and as directed. 10 SQM
79 79 S&F in repairs galvanised steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and as directed. 5 SQM
80 80 M&L for preparing surfaces of small articles such as stop, covers, gully, gratings, hold fast, etc area not exceeding 0.1 sqm each of any description and girth not other wise described and treated with tar or coal tar black paint complete all as specified and as directed. 0.36 PER 100 NOS
81 81 Demolition and breaking up drain pipes 150 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed. 30 RM
82 82 Excavatin in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, laying of cables, pipes, errecting of poles etc., and getting out in hard/dense soil all as specified and directed. 10 CUM
83 83 M&L for salt glazed stone ware drain pipes of internal diameter 150mm grade 'A' laid in trenches and jointed in cement mortar 1:1 mixed with spun yarn and testing complete all as specified and as directed. 30 RM
84 84 M&L for PCC 1:3:6, type C2, using 40 mm graded granite stone aggregate in concrete bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested for complete all as specified and as directed. 28 RM
85 85 Returning and filling in, including spreding levelling, watering and well ramming in layers not exceeding 25cm thick with excavated soil all as specified and directed. 8 CUM
86 86 Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. 2 CUM
87 87 M&L for cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate as in surface channel complete all as specified and directed. 4 CUM
88 88 M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. \n(Note:- Inner girth only measured) 50 RM
89 89 Taking down old unserviceable point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc all as directed.\n 94 EACH POINT
90 90 M&L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & including provn of 1.0 mm thick MS terminal boxes of appropriate size suitable for modular switches sockets etc., fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed for one light point conrolled by one switch\nNOTE: \n1) Cutting chases and making good the disturbed surfaces shall be measured and paid separately 52 POINT
91 91 All as per item No. 90 here in above but for one switch socket outlet 2/3 pin 5Amps multipurpose on indipendent board 30 POINT
92 92 All as per item No. 90 here in above but one bell point controlled by one bell push 6 POINT
93 93 All as per item No. 90 here in above but one light point controlled by 02 two way switches 6 POINT
94 94 All as per Item 90 here-in-before above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor for 3 pin 5/15A socket multipurpose on independent board 12 POINT
95 95 S&F Modular type switch single pole 6 Amps one way, 230 V AC 50 Hz, one module all as specified and as directed. 82 EACH
96 96 S&F Modular type switch single pole 6 Amps teo way, 230 V AC 50 Hz SP, one module all as specified and as directed. 6 EACH
97 97 S&F Modular type Socket 2/3 pin combined, 6 Amps, 230 V AC 50Hz SP one module all as specified and as directed. 30 EACH
98 98 S&F Modular type switch single pole16 Amps, one way 230V AC 50 Hz one module all as specified and as directed. 12 EACH
99 99 S&F Modular type socket single pole 6/16 Amps. 2/3 pin combined 230V AC, 50 Hz two module all as specified and as directed. 12 EACH
100 100 S&F Modular bell bush flush type 6 Amps one module all as specified and as directed. 6 EACH
101 101 S&F Buzzer ding dong AC 230V single pole all as specified and as directed. 6 EACH
102 102 S&F modular frame plate with matching cover plate suitable for fixing switches/ sockets for one modules all as directed.\n 6 EACH
103 103 All as per item No 102 here-in before but for two module 7 EACH
104 104 All as per item No 102 here-in before but for three module 56 EACH
105 105 All as per item No 108 here-in before but for four module 12 EACH
106 106 All as per item No 102 here-in before but for six module\nNote for Item No 102 to 105 The make/model of Modular flush boxes & Modular cover plates shall be the same as that of switches/sockets etc. 10 EACH
107 107 S&F ceiling rose surface PVC/ Polycarbonate, Isolated body with face Bakelite 63.5 x 25mm, three terminal complete all as specified and directed. 52 EACH
108 108 S&F Wall mounted 4 feet LED 20W 6000K battern extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic electronic driver & polycarbonate difuser complete with all accessories, prewired and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Cat No:LDL-20-CDL of CG or techno-commercially equivalent. 24 EACH
109 109 S&F Wall mounted 2 feet LED 10W 6000K battern extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic electronic driver & polycarbonate difuser complete with all accessories, prewired and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Cat No:LDL-10-CDL of CG or techno-commercially equivalent. 12 EACH
110 110 S&F in replacement, Wall mounting, decorative, SS finish, fixtures with textured glass difusser suitable for LED lamp with B22 base with all accessories prewired and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Havells Cat No LHL06160099 or techno-commercially equivalent. 12 EACH
111 111 S&F iLED 10 Watts lamp with base B22 all as specified and directed by Engr-in-Charge. Make: Havells Cat NoLHLDEUEEML8R010 or techno-commercially equivalent. 12 EACH
112 112 S&F energy saving 13.5 W LED bulkhead luminaire with opal diffuser with all accessories prewired and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Havells Cat No LHEXCGP7PN5W013 or techno-commercially equivalent. 4 EACH
113 113 S&F in replacement square surface mounted LED flat panel 18 W 6000K liminaire PDC aluminum housing and PMMA diffuser with all accessories prewired and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Havells Cat No LHESSWP7IL1W018 or techno-commercially equivalent. 4 EACH
114 114 S&F LED security light fitting of 25W comprising of epoxy powder coated housing enclosed with glass cover in frame with protection IP 65 cover white including GI pipe bracket made out of 40mm dia light grade pipe of length 1.2 Mtrs, bend to shape 120-130 degree and MS clamps made out of 25x3mm flat iron 2 Nos including nut and bolts for fixing the bracket and making connections in flexible conduit all as directed. \nMake:- Cat no LSTS-25-CDL_M of CG or techno-commercially equivalent. 4 EACH
115 115 Taking down copper/aluminum sub main wiring of any size and runs complete and removing materials to store for keeping in safe custody or for taking credit making good to walls, floors etc. complete all as specified and as directed. 124 RM
116 116 M&L for sub-main wiring 2 runs of 2.5 sqmm and one run of 2.5 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked complete all as specified and as directed.\nNote:-\n(a) 03 runs of copper conductor & 01 run of PVC rigid conduit (Medium grade) will be considered as one run. 52 RM
117 117 M&L for sub-main wiring 2 runs of 4.0 sqmm and one run of 4.0 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked (for Geyser point) complete all as specified and as directed.\nNote:-\n(a) 03 runs of copper conductor & 01 run of PVC rigid conduit (Medium grade) will be considered as one run. 52 RM
118 118 M&L for sub-main wiring 2 runs of 6.0 sqmm and one run of 6.0 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked (for Main DB to Indl DB) complete all as specified and as directed.\nNote:-\n(a) 03 runs of copper conductor & 01 run of PVC rigid conduit (Medium grade) will be considered as one run. 20 RM
119 119 S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB 20A, SPN, C-Series with Breaking capacity 10KA all as directed. 6 EACH
120 120 Taking down cold unserviceable RCCB, MCB, MCB DB of any size/type/ways complete and removing materials to store for keeping in safe custody or for taking credit making good to walls, floors etc. complete all as specified and as directed. 20 EACH
121 121 S&F MCB DB TPN, 12 Way, IP43, IK09, Metal double door type 240 volts, with minimum capacity of 200 Amps, fitted with busbar and blanking plates, neutral link and making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed. \nNote:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates. 1 EACH
122 122 S&F MCB DB TPN, 8 Way, IP43, IK09, Metal double door type 240 volts, with minimum capacity of 200 Amps, fitted with busbar and blanking plates, neutral link and making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed. \nNote:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates. 1 EACH
123 123 S&F Miniature circuit Breakers, SP, C-Series, 240 Volts of capacity 32 Amps with breaking capacity 10 KA all as specified and dircted. 16 EACH
124 124 S&F Miniature Circuit Breakers, SPN,C-Series, 240 Volts of capacity 32 Amps with breaking capacity 10 KA all as specified and dircted 2 EACH
125 125 cutting chases not exceeding 10 cm girth in stone masonry wall/concrete floor/roof for laying PVC conduit and making good to faceing where required and pointing in cement mortar 1:3 and making good all as specified and as dircted 350 RM
126 126 S&F rigid non metalic PVC conduit of size 20mm dia exclusive of boxes but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe etc all as specified and as dircted 35 RM
127 127 Supply, install, testing & commissioning of Exhaust fan, PVC body with automatic back shutter louvers 250 mm sweep, 1280 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose and making of suitable sized hole in the wall/existing window/ventillator etc. for fixing of the exhaust fan & making good the disturbed surfaces (if any) including taking down of unservicable exhaust fan complete all as specified & as directed. \nNote :- (i) The cost of making hole in walls/other surfaces & making good the disturbed surfaces including any frame work/cement work/ wood work/ welding work etc. required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates.\n(ii) Old unserviceable Exhaust fans should be handed over to MES stores.\n 13 EACH
128 128 S&F in repars of Co-axial modular TV socket all as specified and dircted 6 EACH
129 129 Supply, Fix, Installing and Testing Vertical type Storage electric water heater (Geysers) of 25 Ltrs capacity, Tank made of ultra thick super cold rolled steel plates with high density PUF insulation, 2 KW, 230 V, Single Phase, 50 Hz, AC, BEE 5 Star rated including multifunction safety valve and suitable plug top and 2 Nos anchor fasteners of size as per manufacturer instructions grouting and fixing and making good the disturbed surface complete and connecting electrical and water supply connection using steel braided hose 2 Nos and stickering of Qtr No including taking down of unsurvicable geyser complete all as specified and directed \nNote:- \n(i) Old Geysers should be handed over to MES Stores.\n(ii) Installed Geyser's warrenty card should be submitted to the Engr-in-Charge.\n(iii)The cost of making good the disturbed surface and matching to the existing surface is deemed to be included in the unit quoted rate 4 EACH
130 130 M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of plate not less than 1.5mtrs below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point on completion with and including 15mm bore medium grade GI protection pipe (upto 7.5mtr long) for earth and 20mm GI medium grade for watering including PCC chamber pit & cover with suitable lifting hooks, with funnel, wire mesh, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified including taking out the existing unserviceable earthing accessories.\nNote: On testing after completion, if the desired earth resistance is not obtained the earthing shall be redone at no extra cost till the entire satisfaction of Engr-in-Charge. 4 EACH
Disclaimer :