}

Annual Rate Contract Work For The Maintenance Of Electrical Equipment Of All The Premises And Offices Of Municipal Corporation Bikaner ., Bikaner-Rajasthan

Department Of Local Bodies has published Annual Rate Contract Work For The Maintenance Of Electrical Equipment Of All The Premises And Offices Of Municipal Corporation Bikaner .. Submission Date for this Tender is 01-02-2021. Cutting Crimping and Punching Tools Tenders in Bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

26695505
Annual Rate Contract Work For The Maintenance Of Electrical Equipment Of All The Premises And Offices Of Municipal Corporation Bikaner .
Open Tender
Indian
Rajasthan
Bikaner
01-02-2021

Tender Details

Annual Rate Contract Work For The Maintenance Of Electrical Equipment Of All The Premises And Offices Of Municipal Corporation Bikaner .-1 P&F Bus Bar Chamber Made Out Of Aluminium Or Wrought Aluminium Alloy Suitable For 100 Amp. Capacity Housed In Sheet Metal Box Made Out From 1.6 Mm Ms Sheet Front Penable , Bus Bar Fixed On Epoxy Insulators At Approved Spacing Including Making Connections Etc. As Required. 2 300 Mm Long , 4 Strip 3 With Thermal Magnetic Release, Up To 100 Amp, 10 Ka, Fixed O / L & S / C Setting. 4 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating. Nwith Pipe In Pipe Technology With 80-100 Micron G.I. Coating 5 G.I. Pipe 2000 Mm Long , 50 / 25 Mm , Terminal 12 Mm G.I. Strip 6 P&F 240 / 415 V Mcb Of Breaking Capacity Not Less Than 10 Ka ( B / C / D Tripping Characteristic ) Isi Marked Is 8828 ( 1996 ) ] / Conforming To Iec 60898 In Existing Board / Sheets Including Making Connections With Lugs, Testing Etc. As Required 7 Single Pole Mcb 6 A To 32 A Rating 8 Single Pole & Neutral Mcb 6 A To 32 A Rating 9 Four Pole Mcb, 40 A To 63 A Rating 10 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Heavy Duty Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. N4x16.0Sq.Mm 11 Wiring Of Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1Kv Grade And 1.5 Sq.Mm Fr Pvc Insulated Unsheathed Flexible Earth Copper Conductor 1.1 Kv Grade ( Is:694 ) Of Approved Make In Surface / Recessed Isi Marked Steel Conduit & Its Accessories, Round Tiles, 18 Swg M.S. Box With Earth Terminal, Screwless Cage Connectors For Neutral Looping In Switch Board & False Ceiling Point, 6 A Switch, 3.0 Mm Thick Phenolic Laminated Sheet, Zinc Plated / Brass Screws, Cup Washers, Bushes Check Nuts, Making Connections, Testing Etc. As Required. 12 Short Point ( Up To 3 Mtr. ) 13 Medium Point ( Up To 6 Mtr. ) 14 Long Point ( Up To 10 Mtr.. ) 15 Wiring Of 3 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq.Mm Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) Of Approved Make In Surface / Recessed Isi Marked Steel Conduit & Its Accessories, 18 Swg M.S. Box With Earth Terminal, Screwless Cage Connectors For Neutral Looping In Switch Board & False Ceiling Point, 6 A Switch, 6 A Socket, 3.0 Mm Thick Phenolic Laminated Sheet, Zinc Plated / Brass Screws, Cup Washers, Bushes, Check Nuts, Making Connections, Testing Etc. As Required. 16 On Board 17 Short Point ( Up To 3 Mtr. ) 18 Medium Point ( Up To 6 Mtr. ) 19 Long Point ( Up To 10 Mtr.. ) 20 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi Marked ( Is:694 ) Of 1.1 Kv Grade And Approved Make In Existing Surface Or Recessed Conduit / Casing Capping Including Making Connections Etc. As Required 21 1 X 1.5 Sq.Mm 22 1 X 2.5 Sq.Mm 23 2 X 2.5 Sq.Mm 24 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 25 2 X 4.0 Sq.Mm 26 4 X 16.0 Sq.Mm 27 P&F Following Size Double Lock / Isi Marked Single Lock Pvc Casing Capping & Its Accessories Like Coupler, Inner, Outer, Elbow , Square Box, Tee Etc. With Screws, Pvc Expansion Fasteners As Required 28 20 Mm X 12 Mm ( Group-1 ) 29 32 Mm X 12 Mm ( Group-1 ) 30 Gi Pipe 32 Mm Dia B Class 31 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 32 35.0 Sq.Mm 4 Core 33 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Unarmoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 34 4.0 Sq.Mm 2 Core 35 6.0 Sq.Mm 2 Core 36 10.0 Sq.Mm 2 Core 37 P&F Of Thermoplastic / Pvc Cable Junction Boxes ( United / Hpl Make ) Of Following Sizes Including Clamps For Holding The Box, Cost Of Din Rail For Mcb Mounting, Connectors For Cables Terminals, Threaded Cable Glands Made Of Polyamide Material Etc. Complete In All Respect 38 175Mm X 150Mm X100mm 39 P&F Recessed / Surface Mounting Heavy Duty Horizontal Type Sheet Steel Distribution Board Phophatised / Powder Painted Complete With Copper Bus Bar, Shorting Link , Neutral Link, Earth Link And Din Bar Masking Sheet Conforming To Is13032 & Is8623 Including Making Internal Db Terminations With Copper Lugs , Testing Etc. As Required 40 Double Door ( Single Phase ) 8 Way 41 Double Door ( Three Phase ) 6 Way 42 P & F Isi Marked ( Is :3854 ) 6 Amp. Flush Type Switch Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. 43 P & F Isi Marked ( Is :3854 ) 16 Amp. Flush Type Switch Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. 44 P & F Isi Marked ( Is :1293 ) 3 Pin 6 Amp. Flush Type Socket Including Cutting Hole In Tile And Making Connection Testing Etc. As Required 45 P & F Isi Marked ( Is :1293 ) 3 / 6 Pin 16 Amp Flush Type Socket Including Cutting Hole In Tile And Making Connection Testing Etc. As Required 46 I T C Of Ceiling Fan And Regulator Including Wiring The Down Rod Up To 30 Cm With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. 47 With Regulator 48 Without Regulator 49 P & F Following Modular Accessories Made Out Of Unbreakable And Fire Retardant Poly Carbonate With Silver Contacts Including Making Connections Testing Etc. As Required 50 6 A One Way Switch 51 16 A One Way Switch 52 6 A 3 Pin Socket 53 16 A 6 Pin Socket 54 Rewinding Of Ceiling Fan Motor ( Starting And Running Winding ) Including All Necessary Material. The Motor Is To Be Wound Taking No. Of Coils, Turns And Pitch As It Was Originally Wound With Required Size Super Enamelled Wire With E Class Insulation Material And Making Connections Etc. As Required. ( New Model Ceiling Fan ) 55 1500 Mm Sweep ( New Model Ceiling Fan ) 56 Labour Charges For Removing And Refixing Of Ceiling Fan / Exaust Fan From Site 57 Charges For Oiling, Greasing, Overhauling Of Ceiling Fan, Table Fan, Pedestal Fan Irrespect To The Size Of Fan Including Removing, Refixing Of Fan From Site And Testing Etc. As Required. 58 P & Replacement Of Cover / Bearing Seat Of Ceiling / Exhaust Fan. 59 Desert Cooler 60 P & F Of Stud With Nuts And Washer For Desert Cooler / Exhaust Fan. 61 Replacement Of Cooler Pads ( Heavy ) Set Of 3 No. Of Size 25 X 27 62 P & F Vertical Pump Suitable For 20 Desert Cooler Including Making Connection Testing Etc. As Required. 63 Isi Marked Vertical Pump 64 P & F Fan Motor Suitable For 20 Desert Cooler Including Making Connection Testing Etc. As Required. 65 Isi Marked Fan Motor 66 Rewinding Of Heavy Duty Exhaust Fan Motor Including All Necessary Material, The Motor Is To Be Wound Taking No. Of Coils, Turns And Pitch As It Was Originally Wound With Required Size Super Enamelled Wire With E Class Insulation Material And Making Connections Etc. As Required. 67 600 Mm Sweep 68 Rewinding Of Motor Of Desert Cooler Fan With Super Enamelled Copper Wire, E Class Insulation Material Including Removing, Refixing, Testing Etc. As Required. 69 Replacement Of Defective Compressor By Company Repaired Compressor Of Following Gadgets Including Testing Etc. As Required. ( Carrier / Kirlosker / Techumshe / Shriram / Voltas ) 70 1.5 Tr A.C. 71 2.0 Tr A.C. 72 P & Replacement Of Condensing / Cooling Coil Of Copper Fins For Following Capacity A.C. / Water Cooler / Fridge As Required 73 Servicing Of 1.0 / 1.5 / 2.0 Tr Capacity Air Conditioner After Desmanteling 74 P & Replacement Of Overload Protection Of A.C. / Water Cooler As Nrequired. 75 P & Replacement Of Thermostat Of A.C. / Water Cooler / Fridge As Required 76 P & Replacement Of Selector Switch Of 1.0 / 1.5 / 2.0 Tr A.C Fan As Required. 77 P & Replacement Of Starting Relay Of A.C / Water Cooler / Fridge Compressor As Required 78 S & F Of Capacitor Of 230V / 275V, 50Hz Rating Of Usha / Punsumi / Priya / Capital / Jec / Amcap / Concap Make 79 Starting Capacitor 80 20-30 Micro Farad 81 40-60 Micro Farad 82 P & F Following Modular Accessories Made Out Of Unbreakable And Fire Retardant Poly Carbonate With Silver Contacts Including Making Connections Testing Etc. As Required 83 6 A One Way Switch 84 6 A Bell Push 85 16 A One Way Switch 86 6 A 3 Pin Shuttered Socket 87 16 A 6 Pin Shuttered Socket 88 5 Step Fan Regulator 89 Supply, Fixing And Testing Of Following Capacity Wall Mounted Stablisers Having Output Voltage Variation From 200V To 250V ( + / -5% ) With Input Voltage Variation From 170V To 260V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270V Complete In All Respect 90 3 Kva 91 Sitc Of Walll / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel Made Out Of Crca Sheet, Required Hardware, Duly Painted By Two Coats Of Zinc / Red Oxide Primer Followed By Powder Coated / Epoxy / Pu Painted With Phosphatisation In Grey Or Required Shade After Rinsing. The Panel Having Pu / Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness, Separate Detachable, Gland Plate M.S. Base Channel, Hinged Door With Locking Arrangement For Equipment / Switchgear. Thickness Of Sheet Shall Not Be Less Than 1.6Mm Up To 600Mm Length / Width Of Any Compartment And Be Of 2.0Mm Above 600Mm. Load Bearing Structure Shall Be Of 2.0Mm Thick Sheet Supported By Base M.S. Channel If Required. Side Walls And Cable Alley Compartments Having Bolted Type Doors With Detachable Extension Type Structure ( Only Outer Area On All Sides Shall Be Measured And Panel To Be Fabricated From Cpri Approved Fabricator ) . 92 Labour Charges For Dismantling Of Surface Pvc / Steel Conduit Including Wiring In Conduit, Conduit Fittings And Depositing The Same With Listing Of Material In Store 93 Labour Charges For Dismantling Of Surface / Recessed Switch Board Of Any Size And Depositing The Same With Listing Of Material In Store 94 Labour Charges For Dismantling Of Switch Accessories Like Switch, Socket, Ceiling Rose, Holder And Depositing The Same With Listing Of Material In Store. 95 Labour Charges For Dismantling Of Wiring In Existing Conduit Of Following Size And Depositing The Same With Listing Of Material In Store 96 Up To 2.5 Sq. Mm. Wire 97 4 / 6 Sq. Mm. Wire 98 10 Sq. Mm. Wire 99 S & F Of Star Delta Starter In The Existing Panel With Following Rating 100 7.5 Kw To 9.3Kw 101 P & F Of Ip 20 Led Tube Light 20 Watt With External Batten Made From Crca Sheet Steel Suitable To Replace T-B / T-12 Tube Light, Integral Driver, 2000 Luman + 5Olo Tolerarrce System Luman Efficiacy Of 100 Lm / Watt Minimum Expected Life Time Of 25000 Burning Hours, Cct 5700 I ( Ansi, Cri 80, Driver Efficiency >850 / O, Life Expectancy Of Driver Rnin 30000 Hrs. Pf 0, 95 At Full Load / 230 Volt Ac 102 P & F Energy Efficient / Energy Saving 9 Watt Ip 20 Led Bulb Cool White, In Existing Holder / Fixture As Required, Minimum 900 Lumen Output, 25000 Burning Hours, Cct 5700 I ( Or 6500 I ( [ As Per Direction Of Engineer Incharge ) , Ansi, Lamp Efficacy Minimum 100 Lumen / Watt, Cri 80, Driver Efficiency >850 / 0, Pf 0.95 At Full Load / 230 Volt Ac. 103 P & F 1200Mm Sweep Bee 5 Star Rated Double Ball Bearing Capacitor Start, Aluminium Bady And Blade Ceiling Fan Complying To Is 374: 1979, Ip 50 Watt At Max Speed & 230 Volt, Air Delivery > 210 Cmm, Speed > 330 Rpm With Down Rod Upto 30Cm With 3X1.5 Sqmm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc As Required. 104 Sitc Of 1 Kva Line Interactive, 160-260 V, 50 Hz On-Line Ups With Isolation Transformer Suitable For Single Phase Ac Input And Single Phase Ac Output Having Enclosure Degree Of Protection As Per Ls13947 Part-L / 1993 / 2004 Complete With All Protection With Smf Vrla [ 12V, 7Ah -2Nos ] Batteries, Charger, Switching Device Etc. 105 Supply. Installation, Testing And Commissioning Of 1.8 Kva Pure Sinewave Home Ups / Inverter With 2 Numbers 150 Ah Tubular Battery For Backup. With Following : Nspecifications :- Specificationrating- 1.8 Kva Technology-Dsp Pure Sinewave Ntechnology-Dsp Pure Sinewavel / P V- 120-280V Ac ( Lnverter Mode ) , 180V-250Vac N ( Ups Mode ) O / P Voltage-220Vac Voltage Regulation:- + / - 5% ( On Batt. Mode ) O / P Nfrequency:- 50 Hz + / - 1 Hz ( Battery Mode ) Over Load Capacity:- 110% For 5 Min. On Nmains Mode Efficiency:- Better Than 92% Charging Current :- N7 A / 10A / 12A / 15A / 20A / 25A ( Programmable ) D.C. Voltage:- 24V, Ah Capacity:- N3600vah Lndications:-Mains 0N, Inverter On, O / L, Low Battery, Battery Charging. Protections:- Rev Phase, S Ckt, Over Temp, O / L, Battery Loose. Relative Humidity:- 95%Rh. Non-Condensing Operating Temperature:- 0-50Deg.Cel. Safety Standards:-Lec / En 60950Emc Std:-Lec En62040-1, En62040-2, En62040-3, En61000-4, En60146. Certificates:- Is0 9001, 1S0 14001, 1S0 18001, Rohs & Ce 106 Supplying & Fixing Of 150Ah, 12V, Lead Acid Batteries On Buy Back Basis For Replacing The Existing Old Batteries. [ The Old Battery Shall Be Retained By Contractor ] 107 Supply & Fixing Of Following Ratings Smf Type Batteries For Replacing The Existing Oid Batteries, ( The Old Battery Shall Be Retained By Contractor ) . 108 12V 18Ah 109 12V 7Ah

Key Value

Document Fees
INR 1000 /-
EMD
INR 11930.0 /-
Tender Value
INR 11.93 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail