Provision Of Manifold Room With Pipe Line And Suction Unit At Icu Acute Wards And Isolation Units At Mh In The Area Of Age B/R I At Ge ( N ) Ahmednagar, Ahmednagar-Maharashtra

Military Engineer Services-MES has published Provision Of Manifold Room With Pipe Line And Suction Unit At Icu Acute Wards And Isolation Units At Mh In The Area Of Age B/R I At Ge ( N ) Ahmednagar. Submission Date for this Tender is 09-02-2021. Sewer Cleaning machine Tenders in Ahmednagar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

26684728
Provision Of Manifold Room With Pipe Line And Suction Unit At Icu Acute Wards And Isolation Units At Mh In The Area Of Age B/R I At Ge ( N ) Ahmednagar
National Competitive Bid
Indian
Maharashtra
Ahmednagar
09-02-2021

Tender Details

Provision Of Manifold Room With Pipe Line And Suction Unit At Icu Acute Wards And Isolation Units At Mh In The Area Of Age B/R I At Ge ( N ) Ahmednagar

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 43 Lakhs /-

BOQ Items

Name of Work : Provision of manifold room with pipeline and suction unit at ICU acute wards and isolation units at MH in the area of AGE B/R I at GE (N) Ahmednagar
Sl. No. Item Description Item Code / Make Quantity Unit
1 1 Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortar etc complete all as specified and directed by Engineer-in-Charge 47 Ten Square Metre
2 2 Dismantling hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge 198.5 Square Metre
3 3 Dismantling of false ceiling boards (fibre, pulp, insulation, etc,) or any type ceiling board any thickness including cover fittets etc complete all as specified and directed by Engineer-in-Charge 190 Square Metre
4 4 Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets partly in roof coverings etc complete all as specified and directed by Engineer-in-Charge 295 Square Metre
5 5 M&L for joint free ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor shade etc complete all as specified and directed by Engineer-in-Charge 310 Square Metre
6 6 M&L for joint free ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm on vertical surfaces such as skirting over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade floor etc complete all as specified and directed by Engineer-in-Charge 31 Square Metre
7 7 M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in whte or coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge 24.6 Square Metre
8 8 M&L for glazed ceramic coloured tiles of size 350 x 250 x 7 mm thick on vertical surfaces such as dados over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in whtie or coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge 152 Square Metre
9 9 M&L machine cut cudappa stone slab 20-25 mm thick over cement screed base, laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), set and jointed with grey cement slurry and pointed in grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge 15.5 Square Metre
10 10 Material and labour for rough dressed shahabad stone, 25 mm to 40 mm thick laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), laid and jointed and pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge 160 Square Metre
11 11 Material and labour for 60 mm thick, PCC pavers interlocking tiles of glossy finish, with grey cement and no pigment ,any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5 mm graded mechanically crushed stone aggregates, factory made over and incl 30mm thick sand cushioning and joints filled with fine sand incl levelled with plate vibrator & sweeping etc complete all as specified and directed by Engineer-in-Charge 146 Square Metre
12 12 M&L for granite(of any type) work(table rubbed and polished) cooking platform and like set in cement and sand mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, thickness of granite 16 to 18mm etc complete all as specified and directed by Engineer-in-Charge 15.5 Square Metre
13 13 M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in sub base etc complete all as specified and directed by Engineer-in-Charge 595 Square Metre
14 14 Taking down cement plaster on brick or stone walls or roof slab etc. Incl pointing, raking out joints, hacking for key, scrubbing down with water, etc any description etc complete all as specified and directed by Engineer-in-Charge 1360 Square Metre
15 15 M&L for rendering, 10 mm thick on stone masonry surfaces, concrete surface in cement and sand mortar (1:4) on wall or roof, surface finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge 980 Square Metre
16 16 M&L for rendering, 15 mm thick on stone masonry surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge 320 Square Metre
17 17 M&L for rendering, 10 mm thick on concrete surfaces in cement mortar 1:4 on ceiling finished even and smooth without using extra cement with sagol finish etc complete all as specified and directed by Engineer-in-Charge 80 Square Metre
18 18 M&L for applying two coats of oil bound distemper on newly plastered surfaces of walls over and including 2mm thick wall care putty including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge 380 Square Metre
19 19 M&L for complete removal of existing treatment and applying two coats of OBD over 2 mm thick wall care putty on old plastered surfaces of walls including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge 200 Square Metre
20 20 M&L for applying two coats of cement paint on newly / old plastered surfaces including preparation of surface etc complete all as specified and directed by Engineer-in-Charge 950 Square Metre
21 21 M&L for applying 2 coats of white wash on newly plastered surface including preparation on wall etc complete all as specified and directed by Engineer-in-Charge 140 Square Metre
22 22 M&L for 2 coats of white wash on newly plastered surfaces incl preparation on ceiling etc complete all as specified and directed by Engineer-in-Charge 40 Square Metre
23 23 Material and labour for false ceiling with 4 mm thick plain non asbestos building 'E' board with decorative finish water proofed on one side fixed on and including powder coated GI fabricated grid of 60 cm X 60 cm made out of main runner of 'T' section of size 32 mm X 24 mm X 0.30 mm, cross runner made out of 'T' of section of size 24 mm X 24 mm X 0.30 mm and alround angular section of size 22 mm X 22 mm X 0.70 mm with GI clip and level adjuster duly suspended by 4 mm dia GI wire fixed to roof at 1200 mm centre to centre as per manufacturere's instructions and etc complete all as specified and directed by Engineer-in-Charge 190 Square Metre
24 24 S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge 295 Square Metre
25 25 Supply and fix 0.50 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc complete all as specified and directed by Engineer-in-Charge 120 Square Metre
26 26 M&L for screed bed or bedding layer of mortar 10mm thick in cement and sand mortar (1:3) by using 100% course sand on roof/chajja mixed with & including M&L for WPC @ 3% by weight of cement and finished the surfaces even and smooth without using extra cement to receive water proofing treatment etc complete all as specified and directed by Engineer-in-Charge 40 Square Metre
27 27 M&L for providing waterproofing treatment on roof / chajja / parapet etc. as per latest zonal specification, as per manufacturer's instructions and as specified after taking down / out as existing as site:- (a) M&L for cleaning the newly plastered surface with wire brushes and applying two coats of bituminous primer @ 0.25ltrs/sqm and allow to dry. (b) M&L for applying and laying torch APP polymer midified bituminous membrane 3mm thick with non woven polyster matt as reinforced weighing not less 3 kg / Sqm with white gravel/mineral finished by thermofusion process. 50 Square Metre
28 28 Material and labour for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment, then injection grouting the weak areas on the concrete surface with cementitious grout and applying 10mm thick cement plaster in CM 1:4. Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished rainforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC 1:5:10 type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC 1:4:8 type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, non-skid glazed tiles as per existing pattern/size/tint with and incl WC viterous china squatting pan 580x440mm with integral footrests/pedastal pan incl seat cover, white, area of WC exc 1.00 Sqm but nexc 5.00 sqm etc after dismantling the existing sunken floor etc complete all as specified and as directed. \nNote : Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE.\n 8 Each
29 29 S&F Mild steel TMT bars 6mm to 8mm dia in distribution, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips incld cutting & removal of old decayed reinforcement etc complete all as specified and directed by Engineer-in-Charge 124 Kilogram
30 30 Taking down steel windows / ventilators, of any description and size Each etc complete all as specified and directed by Engineer-in-Charge 24 Each
31 31 Taking down chowkhats or frames n exc 1.5 sq. m Each with shutters (without taking off shutters from the frame) etc complete all as specified and directed by Engineer-in-Charge 32 Each
32 32 Taking down shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm Each etc complete all as specified and directed by Engineer-in-Charge 16 Per Leaf
33 33 S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge\nNOTE: Wire cloth, glass, guard bars and painting shall be measured and paid separately. 5.2 Square Metre
34 34 S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.\nNOTE: Wire cloth, glass, guard bars and painting shall be measured and paid separately under appropriate item of this BOQ 4.8 Square Metre
35 35 S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed by Engineer-in-Charge 35 Square Metre
36 36 All as per item No 35 (here-in-before) but fixed in repairs. 35 Square Metre
37 37 S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter with lock rail and panel of 9 mm B.W.P. commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge 28.1 Square Metre
38 38 S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) etc complete all as specified and directed by Engineer-in-Charge 24.8 Square Metre
39 39 M&L for refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm Each etc complete all as specified and directed by Engineer-in-Charge\n(Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.) 12 Per Leaf
40 40 Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, etc complete all as specified and directed by Engineer-in-Charge \n 74.18 Running Metre
41 41 S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame etc complete all as specified and directed by Engineer-in-Charge 24.96 Square Metre
42 42 S&F 100 mm long butt hinge, medium weight, cold rolled mild steel etc complete all as specified and directed by Engineer-in-Charge 68 Each
43 43 S&F 100 mm long butt hinge, medium weight, stainless steel etc complete all as specified and directed by Engineer-in-Charge 24 Each
44 44 S&F 200 mm long mild steel barrel tower bolt, stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge 42 Each
45 45 S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black etc complete all as specified and directed by Engineer-in-Charge 68 Each
46 46 S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge 48 Each
47 47 S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections etc complete all as specified and directed by Engineer-in-Charge 32 Each
48 48 S&F 150 mm long aluminium anodised handle, cast type etc complete all as specified and directed by Engineer-in-Charge 32 Each
49 49 M&L for preparation of new wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge 115 Square Metre
50 50 S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge 110 Kilogram
51 51 Hacking out old broken glass (any thickness size,quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads n'exc 1.5 Sqm etc complete all as specified and directed by Engineer-in-Charge 24 Square Metre
52 52 M & L for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge 24 Square Metre
53 53 Supply and fix pressed steel frames of size 105 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge 24.6 Running Metre
54 54 Dismantling of water tanks of capacity exc 500 ltrs but n.exc 1000 ltrs and removing from site etc complete all as specified and directed by Engineer-in-Charge 8 Each
55 55 S&F rotational moulded polythene water storage tank 1000 ltr capacity vertical with closed top hoisted and fixed in position in SSR part-I. etc complete all as specified and directed by Engineer-in-Charge 9 Each
56 56 S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed all as specified and as approved by GE/Engineer-in-Charge. 10 Each
57 57 S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe etc complete all as specified and directed by Engineer-in-Charge 11 Each
58 58 Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe etc complete all as specified and directed by Engineer-in-Charge 80 Running Metre
59 59 All as per item No 58 above but 20mm dia pipe 35 Running Metre
60 60 S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed. 80 Running Metre
61 61 All as per item No 60 (here-in-before) but 20mm dia pipe. 50 Running Metre
62 62 Taking down rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overalll as fixed along the cente line over fittings and accessories) etc complete all as specified and directed by Engineer-in-Charge 80 Running Metre
63 63 S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge 80 Running Metre
64 64 S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge 60 Running Metre
65 65 S&F 75 mm dia PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge 8 Each
66 66 S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal alletc complete all as specified and directed by Engineer-in-Charge 8 Each
67 67 S&F 110 mm dia PVC (SWR) bend any radius etc complete all as specified and directed by Engineer-in-Charge 8 Each
68 68 S&F 75 mm dia PVC (SWR) bend with access door any radius etc complete all as specified and directed by Engineer-in-Charge 8 Each
69 69 S&F PVC (SWR) floor trap, 75 mm dia with grating including jointing with solvent cement etc complete all as specified and directed by Engineer-in-Charge 16 Each
70 70 S&F in repair chromium plated grating 100mm dia etc complete all as specified and directed by Engineer-in-Charge 16 Each
71 71 S&F in repair, Bib tap 15 mm dia, fancy type chromium plated, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge 48 Each
72 72 Supply and fix 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed.Make:- Cat part No MOR 1010(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C' 16 Each
73 73 Supply and fix in repair stop valve, 15 mm dia, cast copper alloy,screwed down high pressure screwed down high pressure with cruitch or butterfly handle screwed both ends for iron pipe or for unions all as directed. Make:- Cat part No MOR 1320 (Orintal series) of MARC or equivalent in in makes mentioned in list of makes in Appendix `C' 20 Each
74 74 Supply and fix in repairs, shower rose with shower arm from Make:- Cat part No MARC MSR1050 (Shower) and MOR 1260(Shower arm) from MARC or equivalent in makes mentioned in list of makes in Appendix `C' 16 Each
75 75 Supply and fix tubular towel rail, brass chromium plated 20 mm dia `D' type, 60 cm long between flanges including a pair of brackets all as directed. Make:- (Cat part No UO911 of PLUMBER or equivalent in MARC, ESS-ESS 16 Each
76 76 Supply and fix repairs PVC valveless, syphonic action type, flushing cistern,low level, all accesories all as directed. Make :- Sleek essence series of Hindware or Cat part No E8303 of Parryware of equivalent in Cera 8 Each
77 77 Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren complete all as specified and directed. Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent in Cera 8 Each
78 78 Supply and fix in repairs wash hand basin vitreous China, flat back of size 550 X 400 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap all as directed.\nMake : Cat Part No 10004 of Hindware or Cat Part No C0475 of Parryware. 8 Each
79 79 S&F in repair stainless steel kitchen sink 0.63 mm thick or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc complete all as specified and directed by Engineer-in-Charge 8 Each
80 80 Supply and fix in repairs looking mirror of size 600 mm X450 mm all as directed. Make:- Cat part No C 8606 Of Parryware or equivalent in Jaquar 8 Each
81 81 S&F in repair stainless steel plate rack 0.63mm thick sheet for kitchen ( Size 31"x 36' x 10') etc complete all as specified and directed by Engineer-in-Charge 8 Each
82 82 Excacation over areas upto 3.0 m depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge 3.6 Cubic Metre
83 83 Excavating in trenches, n exc 1.5 m wide and n exc 10Sqm on plan &getting out in hard/dense soil for foundation, etc complete all as specified and directed by Engineer-in-Charge 4.4 Cubic Metre
84 84 M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete etc complete all as specified and directed by Engineer-in-Charge 4.25 Cubic Metre
85 85 M&L for reinforced cement concrete design Mix M-25 using 20 mm graded stone aggregate as in foundations, including rafts, footings,foundation beams; plinth beams; bases for columns, etc complete all as specified and directed by Engineer-in-Charge Note : Reinforcement shall be measured and paid seperately. 3.7 Cubic Metre
86 86 M&L for reinforced cement concrete design Mix M-25 using 20 mm graded stone aggregate as in columns, pillers etc complete all as specified and directed by Engineer-in-Charge \nNote : Reinforcement shall be measured and paid seperately. 1.6 Cubic Metre
87 87 M&L for reinforced cement concrete design Mix M-25 using 20 mm graded stone aggregate as in beams, cantilevers,lintels over 1.5m span; etc complete all as specified and directed by Engineer-in-Charge \nNote : Reinforcement shall be measured and paid seperately. 1.6 Cubic Metre
88 88 M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish surface of concrete flat etc complete all as specified and directed by Engineer-in-Charge 12 Square Metre
89 89 M&L for Formwork to sides of pillars, columns etc rough finished surface of concrete square, rectangular or polygonal etc complete all as specified and directed by Engineer-in-Charge 8 Square Metre
90 90 M&L for formwork to sofits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) rough finished surface of concrete flat etc complete all as specified and directed by Engineer-in-Charge 16 Square Metre
91 91 S&F for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge 230 Kilogram
92 92 All as per item No 10 (here-in-before) but 6mm to 8mm dia 110 Kilogram
93 93 All as per item 10 (here-in before) but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge. 36 Kilogram
94 94 M&L for brickwork with fly ash bricks, old size bricks straight or curved on plan exc.6m mean radius built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge 12.6 Cubic Metre
95 95 M&L for brickwork with fly ash bricks, old size bricks straight or curved on plan to any radius in half brick, built in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge 16 Square Metre
96 96 M&L for damp proof course 20mm thick in cement and sand mortar (1:2) to horizintal or vertical surface including necessary formwork etc complete all as specified and directed by Engineer-in-Charge 6 Square Metre
97 97 Returning, filling in, including spreading levelling including watering & well ramming in layers n exc 25 cm in hard / dense soil etc complete all as specified and directed by Engineer-in-Charge 4 Cubic Metre
98 98 Removing excavated material exc 250 m but not exc 500 m and depositing where directed at a level not exc 1.5 m above starting point etc complete all as specified and directed by Engineer-in-Charge 8 Cubic Metre
99 99 M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete (100 mm compacted thickness) etc complete all as specified and directed by Engineer-in-Charge 5 Cubic Metre
100 100 M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface in broken stone or boulders (15 cm compacted thickness) etc complete all as specified and directed by Engineer-in-Charge 2 Cubic Metre
101 101 M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub-base etc complete all as specified and directed by Engineer-in-Charge 28 Square Metre
102 102 M&L for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed base in cement and sand mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge 31.1 Square Metre
103 103 M&L for rendering 10 mm thick on any type of face of brick work or concrete surfaces in cement and sand mortar (1:6) on wall finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge 50 Square Metre
104 104 M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 on wall finished even and fair with WPC etc complete all as specified and directed by Engineer-in-Charge. \nNote WPC shall be measured and paid separately as supply only 50 Square Metre
105 105 M&L for rendering 5 mm thick on brick work or concrete surfcase in cement and sand mortar (1:4) on ceiling finished even and smooth wthout using extra cement etc complete all as specified and directed by Engineer-in-Charge 25 Square Metre
106 106 M&L for 3 coats of white wash on newly plastered surface including prepration of surfaces on wall etc complete all as specified and directed by Engineer-in-Charge 25 Square Metre
107 107 M&L for 3 coats of white wash on newly/old plastered surfaces including prepration of surface on ceiling etc complete all as specified and directed by Engineer-in-Charge 25 Square Metre
108 108 M&L for 2 coats of cement base paint on newly plastered surfaces including prepration of surface on wall etc complete all as specified and directed by Engineer-in-Charge 25 Square Metre
109 109 Material and labour for rendering 10 mm thick in cement and sand mortar (1:3) on concrete surfaces using water proofing compound finishing the surfaces even smooth with using extrea cement on receive water proofing treatment etc complete all as specified and directed by Engineer-in-Charge \nNote : water proofing compound shall be measured and paid separately as supply only. 30 Square Metre
110 110 Supply only liquid water proofing compound etc complete all as specified and directed by Engineer-in-Charge 1.8 Litre
111 111 M&L for water proofing treatment over RCC slab by applying one coat of bituminous primer @ 0.25 kg/Sqm and providing 3mm thick APP modified water proofing membrane weighing not less 3.5 Kg/Sqm, reinforced with non woven polyster reinforcement mat weighting not less than 160 gm/Sqm, polyster core having softening point not less than 150 degree c, longitudinal tensile strength not less than 650 N/5 cm, tearing strength of 180 n/5 cm including a coat of solar reflective aluminium paint @ 0.15 Kg / Sqm including cleaning the newly plastered surfaces of concrete/ existing plastered vertical surfaces with wire brushes free from dust etc complete all as specified and directed by Engineer-in-Charge 32 Square Metre
112 112 M&L for 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge 0.55 Square Metre
113 113 Supply and fix pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge 7 Running Metre
114 114 M & L for two coats of synthetic enamel paint over red oxide primer on new steel surfaces including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge 2.1 Square Metre
115 115 Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 2000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting complete all as specified and directed. 2 Each
116 116 OXYGEN BASE UNIT\n(a) Oxygen Manifold 2+2 : The oxygen manifold will be of above size of bulk oxygen cylinders. It is suitable to with stand a pressure of 2400 PSI.The main frame are made out of 50 X 50 X 6 mm thick MS angle iron and bottom frame of 20 X 20 mm ms square are installed in such a way that the cylinders must be stage for use in upright position and are not fell down under any circumstances.The gases passed through inter-connecting tail pipes duly fitted with suitable bull nose and nut adopter for cylinder valve and tube size is 10 mm OD Copper tube duly annealed having wall thickness 1.5 mm in spiral shape and the other end of the tail pipe are fixed with non-return valve.The non return valve are fixed in brass block of size 25 mm square vertically which are fitted with high pressure copper tube of size 15mm OD having wall thickness 1.5 mm. Both the arms of manifold further fixed in automatic control panel. All the joints of copper tube, brass block, and inter connecting tubes are welded with silver brazing. Pressure release safety valve also provided. The manifold is fabricated in such a way to give distribution flow of 1500 ltrs per minute. The manifold will be degreased and purged with inert gas before commissioning. The manifold would be enamel painted as per colour code. All above work would be done strictly as per specification and entire satisfaction of engineer in-charge. 1 Set
117 117 (b) Oxygen Emergency Point Specification :- In case of emergency, the supply of medical oxygen is restored immediately with this system. The emergency system will consist of 1 No. Cylinder - configuration This will be suitable to with stand a pressure of 2400 psi. This will be inter connected with high pressure, high flow, double stage control regulator duly fitted with cylinder contents as well as line pressure gauges of 50mm dial size. Pressure release Safety valve are also be provided in this system, so that it will release the pressure beyond 70psi. The outlet point of pressure regulator would be connected with emergency point of oxygen pipe line with the help of inter-connecting adopters. \n 1 Set
118 118 (c) Oxygen Control Panel CE Marked - Semi Automatic Control Panel Specification :The control panel will be supplied as a pre-tested and pr-sated self-contained unit. The control panel is installed in the middle of both arms of manifold and fabricated in such a way that it will withstand of working pressure 2400 psi and test pressure will be 3500psi. It will also supply a flow of 1500 ltrs. Per minute at a pressure of 4 bar (60psi) constantly on either bank.\nFEATURES \n• Electric audio- visual indicators for each bank status.\n• Electrically audio-visual indicators at the time of manual changeover.\n• Impact and weather resistance coloured cover.\n• Independent gauges and indicators.\n• manual change over from on line bank to reserve bank and vise versa.\n• In built low-pressure audio visual alarm.\n 1 Set
119 119 The Duplex Medical Vacuum Base unit As per specifications. : The duplex vacuum system is installed by providing 02 No. vacuum pumps of reputed make of single stage, 2 cylinders.This pump is stationary, air-cooled, splash lubricated, base plate mounted reciprocating type.This pump would be fitted on base plate and belts will be guarded. The company will also provide 1 No. vaccum tank of suitable water capacity as per IS 225 and construction code as per IS 2825 with all its accessories like vacuum gauge, drain valve, inspection window etc.The company will provide interconnection copper piping of size 12mm 0.0 to 28mm OD with BSP vertical non return valve of required size with vacuum gauge of required size of bottom connection with silencer and vacuums filters and all other work to complete the vacuum system and as per the entire satisfaction of Hospitals authority. The capacity of the pump would be about 45 cfm per minute vacuum at 684mm (HB). 1 Set
120 120 TECHNICAL SPECIFICATION : VACCUM PUMP : ( 02 NO'S. )\n1. No. of Cylinders - 2\n2. Lubrication - Splash\n3. Vacuum/ Suction - 45 cfm\n4. Vacuum - 685 mm (HB)(MAX.)\n5. Driver - Electric Motor \n6. Performance test - International Standard \n7. Stages - 2\n8. Mounting - Skid mounted Vertical\n9. Cooling - Air-cooled\n10. Vacuum speed - 600 RPM
121 121 ELECTRIC MOTOR :\n1. Capacity 5 H.P\n2. Rounds per minute 1440\n3. Volts 415\n4. Phase 3\n5. Electric Supply 50 Hz.\n6. Performance test International Standard\n7. Starter Star Delta direct on line\n8. Insulation Class F\n
122 122 VACCUM RECEIVER :\n1. Construction IS 2825\n2. Capacity 200 ltr (appox.)\n3. Foundation Skid\n4. Blast Cap. 300psi\n5. Fittings Pressure Gauge ,Safety Valve , Drain trap Inspection Window\n
123 123 Copper Pipe : Copper tube of soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition.
124 124 12 mm dia 90 Running Metre
125 125 15 mm dia 80 Running Metre
126 126 22mm dia 120 Running Metre
127 127 GASTERMINAL UNIT : Terminal Units (Gas Outlets) with adaptors/probe for oxygen, compressed air and vacuum: Matching adaptors to the gas outlet mentioned above i.e. adaptor for oxygen, air and vacuum. The terminal units would have following features.\na. It would be front insertion type.\nb. Terminal unit would have mechanism with check valve.\nC. Allow single hand operation. \nD. On first insertion of probe the probe shall sit in a standby position. At the stage there shall be no gas flow. \nE. Only on pressing the probe second time, the gas supply would start.\nF. They would close automatically when connected apparatus is removed.\nG. For allowing on line maintenance the terminal unit will be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened.\n
128 128 H. The outlet will be non interchangeable for specific gas and it will accept only correct medical gas adopter/Probe.\nI. The colour code will be as per HTM 2022\nJ. The design of this outlet will be compatible to install vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants.\nK. It would only supply with correct probe/ adopter.\n
129 129 Oxygen 10 Each
130 130 Vaccum 10 Each
131 131 ISOLATION VALVES ASSEMBLY: CE MARKED ISO 9001-2008\nSPECIFICATION: \nTo control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves will be provided. These valves will be of nickel-plated brass body having PTFE seat and inner outer seals. These valves will have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets will be used in between nuts and valve to prevent leakage.\nAll the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies will be on approachable height for easily operation and enclosed in powder quoted visible box.
132 132 TECHNICAL SPECIFICATION\n1. Leakage Clause : 1\n2. Temperature range : Ambient\n3. Working Pressure : 7.5 bar maximum\n4. Test pressure : 50 bar maximum\n5. Standard : As per HTM 2022\n6. Size : 15mm to 28 mm\n
133 133 2 Gases 3 Each
134 134 MEDICAL GAS MONITORING ALARM : CE Marked\n (Area-Wise/Main) Specification :- A Gas failure Alarm will be provided which must be capable of monitoring all the Medical Gases. This alarm will be of Electomechancial Techology, to detect the fault, pressure sensors, which detect deviation from the normal operating limits, will be installed. Each pressure Gas would displayed by coloured LEGEND'S to show normal and ‘Low’ conditions. At the time of receiving the fault the normal window/ indicator stop indication and other window will blink and it also gives audio alarm. The alarm panel will have a test facility to check the internal circuits, mute facility for making silent the buzzer, acknowledgement facility for receiving the fault and reset facility for resetting the alarm after rectifying the fault.
135 135 TECHNICAL SPECIFICATIONS\n1. NO/NC type Selectable - DIP switches/ sensor.\n2. contacts - Volt free\n3. Input voltage - 240 volt AC\n4. Input circuit - Optocouped by using isolating Device\n5. Output Circuit - 12 volt DC.\n6. Contact rating - 1 Amp/240 volt AC.\n7. Window size - 26 mm/ indication lamps. \n8. Colour : Bright Red/ Yellow/ Green.\n9. Lead Life : More than 800 hrs.\n10.Flash rate : 50 / Min.\n11.Power consumption : 1.5 Wt. Maximum\n12.Mounting : wall mounted \n13.Temperature limit : 60 oC\n14.Humidity Limit : 95 % RH\n15.Power supply : AC/240 Volt + 10% \n
136 136 02 Gases \n\n 2 Each
137 137 Bed Head Panel CE MARKED AS PER HTM 2022 : The modular medical turn king system/bed head panel: will be fabricated of aluminous die pressed 1.6 mm thick imported laminated sheet in such a way to provide 100% safe and efficient means to deliver all the gases as well as electrical to the patient/staff in intensive care conditions. To enclosed all piping, electrical wires, monitor wire etc it will be fitted continuously running on wall The design of modular BHU will consist of aluminum section to meet the requirement of HTM 2002, NFPA and other international standard. It will have separate duct for medical gases as well as electrical. There will be no sharp edges having smooth finish and without any visible Reciprocatings etc.It will be have ability fix medical gas outlets, electrical sockets, multi channel music system, nurse’s call bell, IV fluid’s saline and space for placement of monitors.\n
138 138 It will also have colour code around the specific gas outlet and a slide rail for focus lamp. It will be polyester powder coating finish on all external surfaces and would be fitted with wall with the help of 8mm fastners at specific It will be fixed in such a manner that it could be removed easily for servicing and repair.\nIt will be long and continuous to fix for any distance\nFollowing fixed Accessories on Pendant:\n1. Four 5 Amp. Sockets ,2. Two 15 Amp sockets, 3. Two I.V Hooks , 4. Moveable trays for equipments/ Monitors, 5 Colour bin, 6. Telephone Port, 7. Data Transfer Port . Facility to fix Following Accessories Pendant: 1. Facility to hose One Oxygen Outlets, 2. Facility to hose One Vacuum Outlets, 3. Facility to hose One compressed air Outlets ,4. Facility to hose One Nitrous Oxide Outlets 100 Running feet
139 139 BPC Flowmeter with humidifier bottle CE MARKED- will be BPC single type Pipe line Flow Meter unit duly fitted with the fine adjustment valve. It will be back pressure compensated to bear and control the Oxygen Pressure approx. 60psi. Flow meter unit will be consisting of double wall rotta-meter has range of flow 0 to 13 ltrs. per minute with fine adjustment valve. The rotta meter and humidifier bottle will be made of clear, impact resistance polycarbonate (duly graduated). This unit will be have attachment to fit humidifier bottle of capacity 100 Ml. consist of clear, impact resistance polycarbonate jar. This will also have Reciprocating on top for flow meter/plastic cap having nozzles for outlet tubes and the inlet tube end will be multi function combination bubblier/ nebulizer to add the humidity and create an aerosol in Medical Gas min marks will be on jar. This unit will be supplied with PVC Clear green tube of 1.5mtrs. Long duly fitted with disposable Oxygen mask\n 10 Each
140 140 ward vacuum unit : The vacuum regulator will be fitted with vacuum gauge and it also shows flow rate.It will also have overflow safty trap.It will also have emergency on / off lever and fine adjustment valve for regulator. This system will be supplied with pre fitted colour coded gauge having dial size 50mm and vacuum 0 to 760 mm / hg and supplied with all the inter connectiong tube with patient tube 10 Each
Disclaimer :