}

Supplying, Installation, Testing And Commissioning Of Medical Gas Pipeline System And Equipments For Upgradation From 100 To 150 Bedded Esic Hospital At Asansol, West Bengal, ESIC HOSPITAL,ASANSOL-West Bengal

Hindustan Prefab Limited has published Supplying, Installation, Testing And Commissioning Of Medical Gas Pipeline System And Equipments For Upgradation From 100 To 150 Bedded Esic Hospital At Asansol, West Bengal. Submission Date for this Tender is 02-02-2021. Medical Gas Tenders in ESIC HOSPITAL,ASANSOL West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26681809
Supplying, Installation, Testing And Commissioning Of Medical Gas Pipeline System And Equipments For Upgradation From 100 To 150 Bedded Esic Hospital At Asansol, West Bengal
Open Tender
Indian
West Bengal
ESIC HOSPITAL,ASANSOL
02-02-2021

Tender Details

Medical Gas Pipeline System , Asansol Supplying , Installation , Testing And Commissioning Of Medical Gas Pipeline System And Equipments For Upgradation From 100 To 150 Bedded Esic Hospital At Asansol , West Bengal . - 1 Part - A : Medical Gas System. Nsupply, Installation, Testing, Commissioning And Handing Over Of Medical Air Compressor Unit Of 4 Nos ( In Quadraplex System As Per Htm / Nfpa ) Non Lubricated Reciprocating Air Cooled Air Compressors ( Ingersoll Rand , Anestiwata, Hitachi, Kirloskar Make ) With 60 Cfm Refrigerant Type Air Drier With Prefilter, After Filter, 15 Hp Tefc Cage Motors, Drive Package, Suction Air Filters, Starter, Mounting Base Frame Complete With Air Colled After Cooler, Pressure Reducing Station. The Operation Of The Compressors Shall Be Having Auto Cutoff System According To The Preset Pressures For The Lower And Upper Limit. The System Shall Have All The Necessary Controls Like Pressure Switches, Relief Valves, Etc. Including Supply, Installation, Testing, Commissioning And Handing Over Of Air Receiver For The Above Compressors With A Storage Volume Of 3000 Ltrs At Ntp Conditions. 2 Duplex Three Stage Breathing Air Filtration System With By Pass Pipeline System & Isolation Valves. 3 Sitc Of Triplex Medical Vacuum System. The Package Shall Consist Of Reciprocating Vacuum Pumps ( Including Civil Foundation And Electrical Wiring Of Suitable Capacity From Pump To Electrical Panel And Non Return Valve Complete ) With Suitable Hp Motor. The Vacuum Pump, Motor And Associated Accessories As Required Shall Be Supplied As A Package By The Manufacturer, And Not As Discrete Items. Completee System Are As Per Specification 4 Duplex Bacterial Filter Vacuum With By Pass Pipeline System With Isolation Valves. As Per Specification 5 Supply, Installation, Testing, Commissioning And Handing Over Of Oxygen Manifold Comprising Of 2 X 10 Oxygen Cylinders In The Main Manifold And 2 X 4 Cylinders In The Emergency Manifold With Piston Type Heavy Duty, High Flow Oxygen Regulator. 6 S.I.T.C Of Imported Ce Marked Compliant With Htm Or Nfpa Oxygen Change-Over Reduction Box ( Automatic Control Panel ) Of Digital Fully Automatic Type, Capable Of Switching From “Bank In Use” To “Reserve Bank” Without Fluctuation In Delivery Line Pressure And Without The Need For External Electrical Power. The Changeover Panel Shall Be Rated For Min. 175 Qmh At 400 Kpa, And Shall Include The Following Accessories. Panel Shall Comply With Htm / Nfpa & As Per Specification. 7 Supply, Installation, Testing, Commissioning And Handing Over Of Nitrous Oxide Manifold Comprising Of 2 X 3 N2o Cylinder In The Main Manifold With A 2 Cylinders In The Emergency Manifold. 8 S.I.T.C Of Imported Ce Marked Nitrous Oxide Change-Over Reduction Box ( Automatic Control Panel Conforming To Htm / Nfpa ) Of Digital Fully Automatic Type, Capable Of Switching From “Bank In Use” To “Reserve Bank” Without Fluctuation In Delivery Line Pressure And Without The Need For External Electrical Power. Product Should Be As Per Specification. 9 Agss System Consisiting Of Duplex, Skid Mounted Agss Pumps With Remote Switches - Agss Simplex Start Switch. As Per Specification 10 Plant / Master Gas Alarm:- S.I.T.C. Of Imported Ce Marked ( With Ce Number ) Master Gas Alarm For 4-Gases Conforming To Htm / Nfpa. This Panel Shall Be Able To Test Short Circuit Fault, Open Circuit Fault, Source Equipment Fault And Include The A ) Duall Circuit Led Indicators. B ) Test Facility To Check Led C ) Test Facility To Check Led Integrity . Panel Shall Be Equipped With Micro-Procesor Based Alarm. Product Should Be As Per Specification. 11 Supply, Installation, Testing, Commissioning And Handing Over Of Solid Drawn Copper Pipes Manufactured As Per Bs 2871 - En 13348 / Astm B819 Duly Certified By Lloyds Or Third Party Inspection Agency With All Necessary Fittings, Pipe Supports, Etc Complete. As Per Specification 12 A ) . 12 Mm Od X 0.6 Mm Thk 13 B ) . 15 Mm Od X 0.9 Mm Thk 14 C ) . 22 Mm Od X 0.9 Mm Thk 15 D ) . 28 Mm Od X 0.9 Mm Thk 16 E ) . 42 Mm Od X 1.2 Mm Thk 17 F ) . 54 Mm Od X 1.2 Mm Thk 18 Sitc Of Gas Lockable Area Valve Service Units With Integrated Alarm System As Per Specifications, And As Required. Product Should Be As Per Specification. Must Have Gas Pressure Alarm Facility Led Digital Display, Audio Visual Feature. Must Have Emergency Feed Facility In Case Of Shutdown For Intrepted Supply. Ss Sheet Construction, Ce Certified / Ul Listed With Relevant Notified No. On It As Required, Entry / Exist Of Gases From Upward Direction As Per Specification ( Imported ) 19 A ) . 5 Gas Service 20 B ) . 4 Gas Service 21 C ) . 3 Gas Service 22 C ) . 2 Gas Service 23 Supply, Installation, Testing, Commissioning And Handing Over Of Isolation Ball Valves For The Pipelines Complete With Supports, Etc. These Quantities Do Not Include The Valves In The Equipment Room, Which Shall Be Quoted As Included In The Equipment As Specified Above. 24 A ) . 12 Mm 25 B ) . 15 Mm 26 C ) . 22 Mm 27 D ) . 28 Mm 28 E ) . 42 Mm 29 F ) . 54 Mm 30 Supply, Installation, Testing, Commissioning And Handing Over Of Gas Outlets Points As Per Latest Standard & Specification ( Imported ) 31 A ) . Oxygen Outlet 32 B ) . Nitrous Oxide Outlet 33 C ) . Compressed Air Outlet ( 4 Bar ) 34 D ) . Compressed Air Outlet ( 7 Bar ) 35 E ) . Vacuum Outlet 36 F ) . Agss Outlet 37 Electrical Control Panel Equipped Along With Duplex & Cascade System For Air Compressor & Vacuum Pump System 38 Medical Gas B System: 39 Supply, Installation, Testing And Commissioning Etc As Required For Medical Call System: 40 Part - B : Pipeline Accessories. N Back Pressure Compensated Oxygen Flowmeters With A Range Of 0 - 15 Lpm. The Body Shall Be Made Of Brass And Chromium Plated. The Flow Tube Shall Be Of Clear, Impact Resistant Polycarbonate. The Humidifiers Bottles Shall Be Made Of Breakable Polycarbonate And Are Autoclavable At 121 Deg C. The Meters And Humidifiers Shall Be Suitable For The Outlets Offered As Per Specification. 41 Ward Vacuum Units With Unbreakable Collection Jars And Regulators. The Unit Shall Be Supplied With Vacuum Guage To Indicate The Suction Supplied To The Unit. The Unit Shall Have A Bracket For Wall Mounting. The 600 Ml Jars Shall Be Made Of Unbreakable Polycarbonate And Are Autoclavable At 121 Deg C As Per Specification. 42 Theatre Vacuum Units On Mobile Trolleys With Twin 2000 Ml Unbreakable Bottles Made Of Polycarbonate, Autoclavable At 121 Deg C. The Unit Shall Be Supplied With A Regulator With Instant On / Off Switch And Three Way Selection To Use The Left, Right Or Both The Bottles. The Complete Unit Shall Be Mounted On A Trolley With Castor Wheels As Per Specification. 43 Antistatic Hp Tubing For Connection ( 5 Mtr. ) According To Specific Color Coding And Mgpl Standard As Required. 44 A ) Hp Tubing For Oxygen Conversion Kit 45 B ) Hp Tubing For Nitrous Oxide Conversion Kit 46 C ) Hp Tubing For Medical Air Conversion Kit 47 D ) Hp Tubing For Vacuum Conversion Kit 48 Part - C : Bed Head Wall Panels 1 Meter Length Supply, Installation And Providing Wiring And Piping Connections For Bed Head Wall Panels. The Panel Shall Be Fabricated Out Of High Strengths Extruded Alluminium Sections With Inbuilt Single Railing And Powder Coated To Color As Per The Owners Choice. The Panel Shall Have Facility To Accomodate : Max. 5 Nos Of Gas Outlets, 5 / 15 A Multi Pin Switched Socket Outlets - 4 Nos, 1 No Nurse Call Switch Panel With Wired Remote, 1 No Arm Lamp 60W With Adaptor, 1 No Infusion Pump Rail Mount Pole With Adaptor, 1 No Iv Tree Rail Mount With Adaptor And Holder For Vacuum Collection Jar To Be Included With Ot Equipments 49 Extra Item - 1 50 Providing And Fixing Adaptor Or Probe Of Bs Type Oxygen Gas Outlet / Terminal: 51 Providing And Fixing Adaptor Or Probe Of Bs Type Vacuum Gas Outlet / Terminal: 52 Providing And Fixing Adaptor Or Probe Of Bs Type Agss Gas Outlet / Terminal: 53 Providing And Fixing Agss Receiving System: Balancer / Receiver Unit Along-With Connecting Hose For Anaethesia Machine To Receiver And From Agss Outlet To Receiver Unit. 54 Low-Pressure Tube For Vacuum / Suction Unit / Accessories. 55 Providing And Fixing Of 5 Amp Switch With Modular Plate 56 Providing And Fixing Blanker Plate

Key Value

Document Fees
INR 5900 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail